Table Of Contents
Display Introduction:
Fully functional mode:
Simple mode:
The module has two kinds of usage: one is simple mode, another is
fully functional mode. The default is simple mode, if you need fully
functional mode, you can open it by yourself
This module has three special functions, the default is closed, if
necessary, you can open them by yourself
Voltage format: 00.00/000.0 (no unit)
Current format: 0.00R/00.0R (unit: R)
Setting required voltage and current method: After powered on,
default displays set voltage value. Press "SET" can switch to
display current value. Press UP can increase value, press DOWN
can decrease. The decimal point will move with the set value.
Short press for precise setting, long press for quick setting. After
voltage/current is changed, press "SET", it will display "----",
indicating currently set value is saved. The default store bit is
M0. If the voltage/current value is not changed, press "SET", it
will switch to current or voltage value.
Digital Display Content Description
0.00/000.0 Voltage value, 00.00~120.0V
P.000P0.00
P00.0P000.
Power value, unit W, the decimal point po-
sitionwith the power of change and change
position. For example: P.123 represents
0.123W, P1.23 represents 1.23W, P12.3
represents 12.3W, P102 represents 102W
C.000C0.00
C00.0C000.
Capacity values, units AH, the decimal
point is changed with the change of the
capacity position. For example: C.123
represent 0.123AH, C1.23 represents
1.23AH, C12.3represents 12.3AH, C123
represents 123AH
--0- Special features 0
--1- Special function 1
--2- Special function 2
--y- Open Special Function
Close Special features
--n-
SA.-*(* represents 0~9)
Save parameters to the storage location
of a storage location 0-9
Lo.-*(* represents 0~9)
Adjust the position of a given set of
parameters stored in the 0 to 9
Save parameters ---
u00.0
Set the input voltage protection threshold
Connect the input and output, to ensure that the range of input
voltage requirements, the non-reverse. Input voltage must be higher
than the minimuminput voltage
Input Voltage Range: 8V ~ 60V
Input Current Range: 0A ~ 15A
Output Voltage Range: 10V ~ 120V
Output Current Range: 0A ~ 15A
Actual output current is mainly decided by the load. The
current regulation is to set a limit on output current. For example,
if you set 3A output, it means load cant draw over 3A current.
When output is off, output voltage is not zero. It is equal
to input voltage.
After setting press the “OK” button you can export
lower output state when the voltage value is displayed pressing the
key to increase the output voltage, the output voltage can be reduced
by pressing the button, you can press the button to increase the
current
set value when displaying the current value, you can press the button
Save small current setpoint, a short press accurately set,press can
The next output state, press “SET” button to turn off the output
Function 0: After electricity, it will output automatically
Function 1: Save and bring up the parameters, display the power and
capacity
Function 2: Take turns to show the parameters after output
automatically
Open/close method:
Press the “OK button for a while, then electricity, the LED will take
turns to show among “--0- , “--1- and “--2- . When displaying “--0- ,
release the “OK button, it will open or close the function 0. When
displaying “--1- , release the “OK button, it will open or close function
1. When displaying “--2- , release the"OK" button, it will open or close
function 2. After releasing the “OK button, the “--y- displays in the
digital tube indicates that you have already open the current function,
the “-- means that you have closed the current function
The output enable function 0 automatically after power-up
Enable the function after 1, in the non-output state, press the “SET
button in voltage “00.00 the current “0.00R , call up the parameter
Lo.-0 , save the parameters “SA.-0 and set the input voltage
switching between 00.0 threshold cycle
Set parameters are stored Recall function:
Such as the need to 10V, 1.5A stored in the memory location 1 and
bring up the storage location 1 parameters
Press “SET” button to switch to the voltage value, the set voltage
value 10.00V, press the “SET” button to save the current set
voltage value
Press the “SET” button to switch to the current value, the
current value is set the tone for 1.500A, press the “SET” button
to save the current current value
Press theSET” button to switch to “SA.-0 press the button to
select the storage location, where the need to adjust to “SA.-1
press the “OK” button you can set “10V, 1.5A” stored in the
storage location 1
Press the “SET” button to adjust to the “Lo.-0 press the button
to call up the parameters to select the desired storage location,
where the need to adjust to “Lo.-1 press the “OK” button brings
up the storage location 1 parameters
,
Native 0 to 9 groups of 10 storage locations, each storage
location can be arbitrarily set voltage and current values, each
storage location are independent of each other
Set the input voltage protection
Input voltage protection function is mainly used in solar panels
as a power supply circuit, which is set as follows: Start special
function 1, press “SET” button to switch to 00.0, press the arrow
keys to set the voltage value, press the “SET” button Save the
current set voltage value
For example, your solar panels working voltage is 34V current
8A, you want to use this power supply the voltage to 48V, 4.5A,
to recharge the battery, in bright light panels can certainly meet
the power needs (assuming this is the maximum power point).
But when the sunlight becomes weak, the solar panel voltage
drops, assuming 00.0 at this time is set to 30V, when the input
voltage drops to 30V, the power supply will automatically adjust
the output voltage to ensure that will not be pulled down to 30V
or less (ie, to obtain themaximum power)
Enable the function after 2 output will auto rotate voltage, current,
power, capacity, and other parameters
Restore factory settings: the power supply is powered on, press the
SET button, power is automatically restored to factory settings
quickly set. Output state short press “OK” button you can switch the
display of voltage, current, long press 3 seconds can automatically
round display, press again to cancel long wheel significant. In the
next round of significant state, press the button invalid
SKU:200150