Page 2-18 Installation Manual IP Video Door Station D1812 Series 1 D1812 VERSION 1.1, MIN. HW 1.
INSTALLATION MANUAL Read these instructions carefully before starting to use any components. Keep the manual so you can refer to it at a later date if required. If you hand over the device to other persons for use, please hand over the operating manual as well. You can always find the most up-to-date version of the installation manual on www.doorbird.com/support To make things easier we use the term “device” for the product “IP Video Door Station D1812 series” and “mobile device” for a smartphone or tablet.
shock could result. • High voltage may be present internally. Do not open the device. Electric shock could result. • The device is not of explosion-proof. Do not install or use near gases or flammable materials. Fire or explosion could result. • Do not install two power supplies in parallel to a single input. Fire or damage to the device could result. Be sure to connect a single power supply to the device. • Do not connect any terminal on the device to an AC power line. Fire or electric shock could result.
• Keep the device more than 1 m (3.3‘) away from microwave, radio, TV, wireless router and any other wireless devices. • On devices with intercom or built-in speaker or built-in microphone or signal transmission functions, keep the wires more than 30 cm (12‘‘) away from AC 100-240 V wiring. AC induced noise and/or device malfunction could result. • Install the device in an area that will be accessible for future inspections, repairs and maintenance.
ENGLISH COMPONENTS* 1x Main Electrical Unit with call button and front panel 1x Installation manual 1x Metal bar for DoorKing® 1812 Plus Flush Mount 1x Power supply unit (mains adaptor) with four country-specific adaptors 1x Screw connection terminal plugs with cables 1x Quickstart guide with Digital Passport Small parts 1x WIFI antenna with extension cable for external mounting * The sketches in this manual may differ from the purchased model.
DEVICE Front Back 11 12 4 1 13 5 14 2 6 3 7 8 9 10 1) Microphone 2) Light Sensor For night-vision mode 3) Keypad 4) Front panel 5) HDTV Video 6) Speaker 7) Illuminated call button 8) RFID reader 9) Bluetooth transceiver 10) 4D Motion sensor 11) Main Electrical Unit 12) Screw connection terminal 13) Diagnostic-LED Lights up a few seconds after connecting the device to power 14) Clips to mount optional DoorBird 2-Wire Ethernet PoE Converter A1071 or DoorBird AC/DC Converter A8004 VIDEOS Need help wi
ENGLISH 1 SWITCHING OFF POWER Switch off the power to all wires leading to the assembly location, i.e. the DoorKing® 1812, telephony line, door chime, electric gate or door opener, power supply unit for the Doorbird D1812 IP Video door station etc. 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DISMANTLING THE EXISTING FRONT PANEL Unlock and open the DoorKing® 1812 housing with the original key. Next remove the three nuts fixing the DoorKing® 1812 front panel to the DoorKing® 1812 housing.
4 NETWORK CONNECTION OPTIONS OPTION 1 Network cable (recommended, maintenance free) Install a network cable (which is plugged into a network switch / router with Internet access) from the inside of your building to the assembly location. The network cable between the assembly location and the network switch / router can have a maximum length of 80 m/262 ft (IEEE 802.3). If you must span a distance of more than 80 meters/262 feet you can put a network switch in between.
ENGLISH 5 PREPARE POWER SUPPLY The device does not have a battery as power supply, therefore, choose one of the following options. OPTION 1 OPTION 2 To power the device using the provided mains adapter, 2 insulated wires are required. The power supply unit has a 300 cm (9.8 ft) long cable with two insulated wires. The network connection is then established via a network cable or alternatively via WiFi. To power the device via a PoE-Switch (e.g. D-Link DGS-1008P) or PoE-Injector (e.g.
ND D1 D0 IEGAND OPTION 3 Power supply using an AC power supply unit The DoorBird D1812 supports DC power supply units only. The “DoorBird AC/DC Converter A8004” is sold separately if you want to use e.g. the DoorKing® AC transformer “1804‐059” to power the 6 DoorBird D1812. There is a holder with clips on the back of the DoorBird D1812 Main Electrical Unit to mount the DoorBird AC/DC Converter A8004 conveniently.
ENGLISH 6.2 PHONE LINE & RELAY MONITORING Connect the cable “Phone line cable (Part #D1812G)” and the cable “Relay monitoring cable (Part #D1812J)” from the DoorBird D1812 Main Electrical unit to the main terminal connector (18 pin jack) of the DoorKing® 1812 control board.
6.3 INTERFACE CABLE Interface cable For the next step you must determine the revision of the DoorKing® 1812 control board. You can find the revision written on a sticker or printed on the bottom right on the control board as marked in the drawing. It is either “1871-010” (for DoorKing® 1812 Classic) or “1970-010” (for DoorKing® 1812 Access Plus). If you find a different revision, please contact us before continuing with the installation.
ENGLISH 6.5 DOORBIRD D1812 CONNECTION TERMINAL PWR LED E1 E1 GND D1 D0 WIEGAND (DK) PHOUT (DK) Call Button, SPK, MIC R1 R1 R1 R2 R2 R2 N.O. C N.C. N.O. C N.C. (DK) REL MONITORING + 12-15 VDC Port Description E1, E1 Digital input (0 V, 0 A (NO)), for door opener button, max. 0 V DC/AC, 0 A. These ports can be used to connect e.g. a door opener button inside the home.
R2 N.O. Relay #2, max. 24 V AC/DC, 2 A Contact for “Normally open” state. Closes when triggering. Connect the contacts of your gate or door opener here, which you connected previously to the main terminal connector (pin #14 of 18 pin jack) of your DoorKing® 1812. R2 C Relay #2, max. 24 V AC/DC, 2 A Contact for “Common terminal”. Connect the contacts of your gate or door opener here, which you connected previously to the main terminal connector (pin #16 of 18 pin jack) of your DoorKing® 1812.
ASSEMBLE THE FRONT PANEL TO THE BACK HOUSING The DoorBird D1812 is designed in such a way that no nuts are needed to fix it in place. Just slide the front panel straight into the DoorKing® 1812 back housing and secure it with the lock in the front panel and key provided. Make sure no one is working beneath the DoorKing® 1812 / DoorBird D1812, as the DoorKing® 1812 housing and DoorBird D1812 front panel have sharp edges which may cause injuries.
CONFIGURE THE SPEAKER AND MICROPHONE You can configure the speaker and microphone volume using the potentiometer on the DoorKing® 1812 control board. Please see the manual of your DoorKing® 1812 how to do this (https://www.doorking. com/product-documents-and-downloads). Normally you can leave this at the DoorKing® 1812 default settings. DIAGNOSTIC-SOUNDS After around one minute, the device emits brief diagnostic sounds after it has been connected to power supply / network / internet.
Stainless steel PVD coated PVD coated, chrome-plated or gold-plated surfaces are recommended to be cleaned with a greasedissolving detergent and clear water or with a clean and dust-free microfibre cloth. For high-gloss surfaces, use a scratch-free cloth (e.g. cleaning cloth for glasses, furniture polishing cloth, etc.). Lacquered surfaces Clean painted surfaces and lettering with a soft, scratch-free cloth moistened with a mild soap solution (e.g. cleaning cloth for glasses, furniture polishing cloth, etc.
LEGAL NOTES General remarks 1. DoorBird is a registered trademark of Bird Home Automation GmbH. 2. Apple, the Apple logo, Mac, Mac OS, Macintosh, iPad, Multi-Touch, iOS, iPhone and iPod touch are trademarks of Apple Inc. 3. Google, Android and Google Play are trademarks of Google, Inc. 4. The Bluetooth® word mark and logos are registered trademarks of Bluetooth SIG, Inc. 5. DoorKing® is trademark of DoorKing, Inc. 6.
www.doorbird.