LL_ATC-3 Controller Startup Manual and Specifications 1
Content General Use & Safety Information .................................................................................................... 3 Limited Electronics Warranty & Repair Policy .............................................................................. 4 LavaLock® ATC-3 Features ................................................................................................................ 5 Probe Placement ......................................................................................
General Use & Safety Information ALL BBQ RELATED PRODUCTS MAY CAUSE A POTENTIAL RISK FOR BODILY HARM OR PROPERTY DAMAGE. PLEASE READ AND UNDERSTAND THIS USER’S GUIDE COMPLETELY BEFORE INSTALLING OR USING THIS PRODUCT! WARNING: NOT INTENDED FOR USE BY CHILDREN! This product is intended for use for adults only. Not intended for use by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge. Never let children operate or play around active barbecues.
CAUTION: USE OF TRADITIONAL FIRE EXTINGUISHING METHOD IS ENCOURAGE. Keep pit clean and free of fat and grease build up to reduce accidental pit fires. CAUTION: The control unit has no user-serviceable components. Opening or making unauthorized alterations to equipment can cause it to fail, posing a danger. Limited Electronics Warranty & Repair Policy LavaLock® ATC-3 controllers are covered by 1 year replacement warranty for manufacturer material or workmanship defect.
LavaLock® ATC-3 Features - Smart PID full-cycle control algorithm for accurate and stable Pit temperature control. Conntects to your WIFI enabled phone for direct access to temperatures and all the control settings. Quick and easy operation on the controller itself. Advanced setup and cook data shown on phone application. Controls your pit temperature and monitors all four probes’ statues. Pit and meat probes are made of armored, dishwasher-safe materials. Real-time pit, meat and fan statuses.
2.3.2 Tuya Smart searches the ATC-3 controller nearby and enter the pairing mode. 2.3.3 Make sure both the phone and ATC-3 controller are covered by strong WIFI signal. 2.3.4 Enter the WIFI network password and the ATC-3 controller will start connecting to the WIFI network. 2.3.5 Once ATC-3 controller is connected to WIFI, the device will be shown in the home menu. 2.3.6 Press the device icon to enter control menu. 2.4 If users want to change device WIFI network, please follow the instruction below. 2.4.
3.2 Open lid detection: If the Pit temperature has already reached the target temperature, and drop more than 25% below the preset temperature, this may be caused by the lid opened. The controller will beep and phone will receive the alert. 3.3 Fire detection: If the Pit temperature increases more than 25% hgiher the preset temperature, this may be caused by the fire or other conditions. The controller will beep and phone will receive the high temperature alert. 3.4 Meat Alarms 3.4.
Note: The 35 cfm is standard fan for the ATC-3 controller. The controller could run a much larger fan with XX cfm to support large sized pits. For large sized pits solutions, please contact info@islandoutdoorll.com or visit xxx for product recommendation. FAN Adaptor Kit 1 Main threaded adapter can fit almost any cooker. Drill a hole near the original intake damper on the cooker and secure with the supplied nut.
Care and Maintenance Probes. The pit and meat probes are the most fragile components of the controller kit. Improper care, inspection and maintenance can cause failure or improper readings. Remove probes from BBQ after each use to clean and inspect. Clean regularly with a damp cloth or scotch brite pad. DO NOT submerge in water or dishwasher. Heat to disinfect at startup. Avoid excessive heat. Controller. Always store in a dry area, free of corrosive air and avoid dropping. Wipe clean, do not submerge.
Troubleshooting Guide ⚫ Probes do not read properly. Inspect probe for heat or wire damage. Ensure that the correct probes are being used and installed fully into the probe port. Probes are not interchangeable with other brands. Note: water boils at 212°F, but that may vary based on elevation. If you suspect a bad probe, it may be helpful to test by swapping the probe with one that is working. ⚫ Unit turns on but fan does not. Verify Pit temperature set points. Inspect fan and wiring for damage.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.