Thermometer & Disinfector Instruction Manual DP-300 - Thank you for purchasing the Dipeng DP-300 Thermeometer & Disinfector. - For your safety and enjoyment, please read this manual thoroughly before use. - Please retain this manual for further reference. - For specific information about your own temperature, CONSULT YOUR DOCTOR. Notified The illustrations in the manual are merely design sketchs,for demonstration purposes only.
Important Safety Information These safety instructions must be strictly followed in use to avoid personal injuries and property damage are as follows: Warning - Do not disassemble, repair, or modify the unit. - Conducting self-diagnosis based on the measurement results and/or treatment can be dangerous. Please follow the instrustions of your doctor. - Do not use this unit other than for measuring the human body temperature.
1.Overview ON/OFF Power Supply Socket Display Indicator LED Nozzle Waste Tray 2. Before Using 2 . 1 Included Accessories Screws And Nuts Nozzles Rack For Wall Mounting AC Adaptor Funnel Key 2 .
2.3 Installation Lock Position Anti-Dismantle Screw Position Notified - If doubt in readings, please adjust measuring popsture and take few more readings for comparison. 3. How To Use 3.1 Plug the power supply into the power socket on the side of the unit, turn the switch to “|”. A ” ”will soon appeal on the screen, and the indicator LED with breathing light cirulates in green. Switcher On “|” Power Supply Socket LED 3.2 Use the key provided to unlock the top lid of the unit and remove the lid.
Notified Please only use the specified types of disinfection liquid. 3.3 To Take Temperature And Disinfect Hands 3.3.1 To begin the procedure, reach both hands beneath the nozzle, make sure the inner side of the wrist is uncovered and exposed under the breathing light. Hold the position for more than 2s until the temperature result is displayed on the screen, then the nozzle will spray disinfectant for 1-2s, the procedure completed. *Black Dotted Line Is Measure Area 3.3.
4. Replacing Nozzle 4.1 When uneven spray or blockage occur, please replace the nozzle. Simply rotate the nozzle cap to unlock. 5. About Human Body Temperature Knowing One’s Normal Temperature In order to make a correct judgement on whether an individual is having a fever, it is important to understand what is the normal temperature range. Body temperature varies from person to person, and will also vary according to the time of the day.
Please do not measure immediately after intense exercise, or immediately after exposure to strong sunlight or sweating. Please make sure the measuring area (inner wrist) is not covered by clothes, jewelry or watch etc., for an accurate reading. 6.
7. Troubleshooting Please refer to the table below for common issues/solutions. if the problem persists, please contact you local customer service for help. Issue Cannot be powered on to ready stage Spray not functioning properly Possible Causes -Not using the original adaptor(or not the correct voltage). -Adaptor or the power plug gone loose. The power plug is not plugged in properly, or the switch is not on. Hands are not reached into the sensing area. The nozzle is partially blocked.