LRNV9324-4I Test Report Product Model: LRNV9324-4I Number: LR19031402 Date: 2019-03-14 PS: The first 6 number of No. Format LR19092401 is the date number, the last 2 one is the sequence number.
Test Sample Sample status or version: (See photo below)
Catalog 1 TEST ENVIRONMENT ............................................................... 2 1.1 Environment&Topology ...................................................... 2 1.2 Software&Introduction ........................................................ 2 1.3 DUT storage server setting ................................................ 3 2 LRNV9324-4I BASIC FEATURES ............................................. 3 2.1 LRNV9324-4I Feature Functionality ................................... 3 2.
Aim: The test figures out the relevant validations of the Product LRNV9324-4I according to its characteristic and performance and provide the tech foundation for further equipment selection. 1 Test Environment 1.1 Environment&Topology Temperature 10-35℃ Humidity 40%-80%RH Voltage 220V±10% Topology Topology Server 1.2 Software&Introduction No. Name Model Version 1 SANergy sanergyconfig FS_3.2.7.0 2 ATTO ATTO Disk Benchmark V2.47 3 CrystalDiskMark CrystalDiskMark 6.1.
random read/write to judge the disks. 1.3 DUT storage server setting CPU: Intel(R)Xeon(R) CPU E5-2603 v3 @ 1.60GHz Motherboard: Supermicro X10DRL-I Memory: 8 GB ( Hynix DDR4 2133MHz ) Operating System: Windows 7 Ultimate 64bit System Disk: SANDISK SSD ( 60 GB / Solid Disk ) DUT(tested): LRNV9324-4I SSD Disk: Samsung SSD 970 EVO M.2 500GB*4 Adapter Card: LRNV45N1-V2 Cable: SFF-8643 to SFF-8639 NVMe Cable 2 LRNV9324-4I Basic features 2.1 LRNV9324-4I HBA Feature Functionality Pros: suitable for M.
High-profile☐ Fail Low-profile☐ Fail Reason: Test Item chassis Requirement No gaps and interference-free with components Method 1、 Install DUT onto PCIe slot. 2、 Fix the screws. 3、 DUT should be parallel with motherboard. 4、 The height of Heat sink doesn’t interfere the installment of other cards next to it. High-profile Pass Low-profile Pass Result High-profile☐ Fail Low-profile☐ Fail Reason: 2.3 Dimension Connector ☐ X16 X8 ☐ X4 ☐ X2 ☐ X1 8643 4GB/s Dimension(mm) 147(L)*68(W)*1.
Windows 10 X86_64 Pass ☐Fail Windows Server 2012 R2 X86_64 Pass ☐Fail Windows Server 2008 R2 X86_64 Pass ☐Fail RHEL/CentOS X86_64 Pass ☐Fail VMware ESXi 6.5 X86_64 Pass ☐Fail Ubuntu 16.04 X86_64 Pass ☐Fail 6.5/7.1 3.3 Drive Windows (Built-in driver)No driver display, device can be seen. Linux (Built-in driver)No driver display 3.
4 Read/Write performance 4.1 ATTO Test Item: ATTO software Read/Write test Requirement: Connect SSD with card according to Topology1 and test four M.2 SSD 500GB disks, Read ≥ 3000MB/s under complete load; Write ≥2400MB/s under complete load. Method: Connect SSD with card according to Topology1 and test four M.2 SSD 500GB disks, Read ≥ 3000MB/s under complete load; Write ≥2400MB/s under complete load.
4.2 CrystalDiskMark Test Item: CrystalDiskMark test Requirement: Connect SSD with card according to Topology1, test four M.2 SSD 500GB disks, Read ≥3100MB/s under complete load; Write ≥2400MB/s under complete load. Method: Connect SSD with card according to Topology1, test four M.2 SSD 500GB disks, Read ≥3100MB/s under complete load; Write ≥2400MB/s under complete load.
5 Aging Test 5.1 SANergy test Item: SANergy test on Read/Write Speed Requirement: 1、 Connect SSD with card according to Topology1 and test four M.2 SSD 500GB disks 2、 Test four SSD disks at the same time with SANergy software 3、 Check if they could be recognized or data exception Method: Connect SSD with card according to Topology1 and test four M.2 SSD 500GB disks. Test four SSD disks at the same time with SANergy software for 8 hours.
6 Striped volume performance Test 6.1 SANergy Test Item: SANergy test for Read/Write speed Requirement&Method: 1、 Connect SSD with card according to Topology1 and create striped volumes in the system.
6.2 CrystalDiskMark Test Item: CrystalDiskMark test Requirement&Method: 1、 Connect SSD with card according to Topology1 and create striped volumes in the system. 2、 Test the Read/Write Speed with CrystalDiskMark software 3、 Write Speed≥6000MB/s, Read Speed≥6200MB/s Result Pass ☐Fail Reason: 7 Test Summary 1. 2. 3. 4. 10 Slot the card LRNV9324-4I into the server according to Topology1, the read/write performance have reached the SSD’s upper limit, HBA functions are normal.