User's Manual

INSTALLATION SHEET
1127C PIR Motion Detector
Description
1127C is an 1100 Series Wireless Wall Mount Curtain PIR. The Detection area is a 50’ x 10’curtain using a fresnel lens.
The PIR includes a case tamper and functionality to allow sensor conguration from the control panel. DMP Exclusive
Features include Sensitivity Adjustment, Pulse Count, Walk Test, & Disarm Disable.
Features
• Remote conguration from panel
• Excellent R.F.I. and noise immunity
Adjustable sensitivity from panel programming
• Pulse count selection allows multiple triggers
before an alarm is initiated
• Walk Test mode initiated from panel
• Disarm Disable operation to save battery life
• Installs up to 8’ wall height
Compatibility
All DMP 1100 Series Wireless Receivers and panels
What is Included
The 1127C Series PIR Motion Detector includes the
following:
• One PIR detector with DMP wireless transmitter
• Two CR123 batteries
• Zone name and number label
• Serial number label
Installation
For your convenience, an additional pre‑printed serial number label is included. Prior to installing the device, record
the serial number or place the pre‑printed serial number label on the panel programming sheet. This number is
required during programming. As needed, use the zone name and number label to identify a specic transmitter.
Selecting the Best Location (LED Survey Operation)
The PIR transmitter provides a survey capability to allow one person to conrm transmitter communication with the
receiver while the cover is removed. The PIR transmitter PCB Red Survey LED turns on whenever the processor turns
on to send data to the receiver then immediately turns off when the receiver acknowledgement is received and the
processor shuts off. While in Walk Test mode, waving your hand in front of the PIR is a convenient way to send data
to the receiver to conrm operation. The PIR
circuit board LED lights to indicate motion
and the Survey LED briey lights to conrm
communication.
When the transmitter does not receive an
acknowledgement from the receiver, the
transmitter Survey LED remains on for about
8 seconds to let you know communication is
not established. Relocate the transmitter or
receiver until the Survey LED immediately
turns off indicating the transmitter and
receiver are communicating properly. If the
transmitter is not programmed into the panel,
the Survey LED does not operate properly.
Figure 1: Remove the Cover
Cover Lock Screw
Figure 2: Detection Pattern

Summary of content (4 pages)