ECG/EKG Recorder
CONTENTS Package Content and Know Your Unit Package Content Main Unit Battery Replacement Getting Started The LCM Display Introduction Operating Instructions Power on/off Measurement Historical Record .Review Measurement Record .Delete Record Setting .Date and Time .Alarm .Bluetooth Bluetooth: (Upload record to PC/server) USB: (Upload record to PC/server) Important Safety Note Maintenance and Storage Troubleshooting Warranty Information Manufature Date Specifications 02 03 04 07 09 10 11 13 15 17 18
Package Content and Know Your Unit Getting Started Package Content The LCM Display Bluetooth Low Battery Indicator Alarm Instruction Manual AAA Batteries Cardio Care Unit Protective Pouch Main Unit Power Up\Increase Down\decrease Enter Left Electrode Chest (back) Electrode Exit USB Port Battery Replacement 1. Remove the battery cover. 2. Put 2 new 1.5V AAA alkaline batteries. 3. Put the battery cover back.
Operating Instructions Power on / off Press to turn on / off Cardio Care. After the welcome message, You will enter main menu automatically, where you can proceed on taking measurement, checking historical record or adjusting setting. C. Press and it will start measuring with a beep sound after 5 seconds.
Important Notes on Taking Measurement In order to obtain an accurate ECG/EKG reading, it is important that measurement is taken correctly. Before taking measurement for the first time, read these instructions carefully and make sure you observe the following points each time you take measurement. Historical Record Historical record page can be accessed directly after measurement or through Menu selection. .Make sure that the electrodes are directly touching your skin.
.Delete Record (A) Delete All Record Please go to the historical record page, then press and hold key for 2 seconds to delete all record stored in this unit. (B) Delete Single Record Press and hold key record. for 2 seconds to delete while playing the Setting Setting page can be accessed directly through Menu selection. & .Date and Time: Press to set date and time and to the previous step. Press Press to confirm. Press to return to decrease the number. to increase the number.
Bluetooth: (Upload record to PC/server) .Bluetooth (A) Turn ON/OFF 1. Download “My Cardio Care” Please download and install ”My Cardio Care“ from our website http://www.digio2.com before uploading record to PC/server. Go to http://www.digio2.com -> Press “Download” -> Press “Healthcare Device” -> Press ”My Cardio Care” (Download and install “My Cardio Care” to your PC) Press and to select ON/OFF to confirm.
4-2. Press to enter the desired record for upload. The screen will show “ Upload to Server?” 1. Download “My Cardio Care” Please download and install ”My Cardio Care“ from our website http://www.digio2.com before uploading record to PC/server. Go to http://www.digiO2.com -> Press “Download” -> Press “Healthcare Device” 4-3. Press to upload the record to PC/ server. 4-4. If the upload is complete, the PC/ server monitor will show ECG/EKG waveform.
3. Connect Mini USB cable .Prepare one Mini USB cable If user connect the ECG with PC by USB cable, the ECG will not has measurement function, and user can only transfer the data to PC. .Please connect Mini USB/USB cable to Cardio Care. Important Safety Note Safety Labels Used in this Manual " Warning" indicates a potentially hazardous situation which, if not avoided, could result in serious injury. 4-1.
.Do not take measurements when there are drops of water on your skin, such as from sweat or after bathing. Maintenance and Storage .Do not take measurements where the unit will be exposed to strong electromagnetic forces. .Clean the unit with a cloth dampened with water or mild detergent, then wipe it dry with a dry cloth. .ln order to achieve accurate measurements, please replace new batteries when low battery indicator is on. .Wipe the electrodes using a cloth dampened with ethyl alcohol (75% v/v).
Troubleshooting Warranty Information Problem Cause Solution Nothing happens when you press the power button The batteries are worn out. The batteries are inserted incorrectly. Replace both batteries with new ones. Insert the batteries with their polarities correctly aligned. Measurement finishes but result is abnormal. The electrodes are not making good contact with your finger or chest. Check the instructions and repeat the measurement. Your body is too tense. Relax and repeat the measurement.
Specifications ECG/EKG Specifications Power Supply Standard Sensitivity Input Impedance Input Dynamic Range Bandwidth ECG-10X 1.5V AAA Battery*2 _ 5% 10mm/mV + >10M ohms + / - 2mV 0.005 ~ 40 Hz CMRR > 95 dB AD Conversion 12 bits Sampling Frequency Measurement Time Dimensions (WxDxH) unit: mm Weight(with batteries) 256 samples/sec 30 sec. 125x64x27 144g Environmental Conditions .Storage Temp. -20 C ~ 50 C .Operating Temp.
Federal Communications Commission (FCC) Statement 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.