User Manual DA16200 AT GUI Tool
DA16200 AT GUI Tool Contents Contents ............................................................................................................................................... 2 Figures .................................................................................................................................................. 3 Terms and Definitions ......................................................................................................................... 4 References .............
DA16200 AT GUI Tool Figures Figure 1: Terminal Configuration ........................................................................................................... 6 Figure 2: Development Kit connections ................................................................................................. 7 Figure 3: AT GUI ................................................................................................................................... 8 Figure 4: RS232 Setup - Disconnected ..............
DA16200 AT GUI Tool Terms and Definitions GUI UART SSID DHCP AP USB MFC Graphical User Interface Universal Asynchronous Receiver Transmitter Service Set IDentifier.
DA16200 AT GUI Tool 1 Introduction This section introduces the subject or problem described in this document. The DA16200 GUI tool (DA16200_GUI_yyyymmdd.exe) lets users control DA16200 EVK in GUI environment. It provides two modes of operation: Certification mode and Network mode 1.1 Certification mode This mode is for Wi-Fi RF test (Tx power, Rx sensitivity, etc.) aka “TEST Mode”. 1.
DA16200 AT GUI Tool 2.2 Setup Serial Terminal Utility Users can control DA16200 by using a serial terminal tool (e.g. Teraterm or SecureCRT) and the following configurations are required to connect to the console of DA16200. ● ● ● ● ● ● Port: Com port number on Windows system Baud rate: 115,200 bps Data bits: 8 bits Parity: None Stop bits: 1 bit Flow control: None Figure 1: Terminal Configuration When the DA16200 board is connected, two COM ports will be detected on the Window machine.
DA16200 AT GUI Tool 3 How to Run GUI for DA16200 Board 3.1 Board Setup DA16200 AT GUI program is a single executable file. Note: If an error message which tells “a DLL file (e.g. vcruntime140.dll or mfc1400u.dll) is missing” prompts when running this tool, You need to install Microsoft Visual Studio redistributable package (https://www.microsoft.com/en-us/download/details.aspx?id=48145) or copy the dll file into the Windows system folder (C:\Windows\System32 or C:\Windows\SysWOW64).
DA16200 AT GUI Tool Figure 3: AT GUI 3.2 Board Connection ● When AT GUI program runs, connection status is red (not connected). If any COM port is not detected by the program, press the R button to refresh COM Port Figure 4: RS232 Setup - Disconnected ● Select a COM port and click the RS232 OPEN button. (Wait for a few seconds). Connection status will be soon changed to green color and you can see “Connected” status with green color .
DA16200 AT GUI Tool 3.3 RF Certification Mode Setup To enable certification mode, check on the mode option on the Chip Setting tab Figure 7: Certification Mode Configuration Alternatively, on the Certification Mode tab. Figure 8: Certification Mote Tab 3.3.1 TX Test Mode ● Move to the Certification Mode tab Figure 9: Tx Test Mode Configuration User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool ● Check TX Setting parameters and click the Mode Select button. Confirm message will be shown as Figure 10. This is a normal state Figure 10: Debug Console - Tx mode ● Have to select Data Rate, Channel, and Power as you want to test. ○ Packet mode: Normal test mode with packet generation mode. We can adjust duty of RF Burst at time domain in this mode. ○ ○ ○ ○ ○ ○ ○ ○ Cont mode: Continuous TX out mode. This mode is for TX power test and etc.
DA16200 AT GUI Tool Start TX Stop TX Figure 11: Start & Stop Tx ● Tested setting is 802.11n MCS7, channel 1, 100 bytes packet and power grade 0. ○ When you click the Start TX button, you can see messages as blow. Figure 12: Debug Console - Start Tx ○ When you click the Stop TX button, you can see messages as blow. Figure 13: Debug Console - Stop Tx User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool 3.3.2 RX Test Mode ● RX Setting ○ Channel: Support CH1 ~ CH13 ○ Test Time: Maximum 3600s (Duration is 1 second fixed) Figure 14: Rx Configuration ● RX Packet Rate ○ FCS + PHY + Overflow packet / Total packet = Error rate 3.4 Network Mode Setup To enable network mode, check on the mode option on the Chip Setting tab. Figure 15: Network Mode Configuration User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool Alternatively, on the Certification Mode tab. Figure 16: Network Mode Tab 3.4.
DA16200 AT GUI Tool Figure 19: Station Mode - Choose AP and Connect Figure 20: Debug Console - Connect to AP 3.4.2 AP Mode ● Choose the AP Mode and click the Select button on the Mode Select option then network mode is changed, DA16200 reboots and the AP Mode setup window will be shown as Figure 22. Figure 21: Debug Console - AP Mode ● Set SSID, password, country, channel and security mode and click the Confirm button. Figure 22: AP Configuration User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool Figure 23: Debug Console - AP Configuration ● Configure DHCP server. Set IP addresses and click the Confirm button. When a client is connected, its MAC address will be shown as Figure 24 Figure 24: DHCP Configuration Figure 25: Debug Console - DHCP Configuration User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool 3.5 OTP Mode Setup To enable OTP mode, check on OTP Enable option on the OTP Mode tab then the current OTP data will be shown in Figure 26. Figure 26: OTP Mode ● Power calibration and temperature calibration has been completed for the chipset by FCI and it may not need to be done by the customer. ● Freq Offset cal The range of frequency offset calibration is 0x0 ~ 0x7F. ● MAC Address setup DA16200 provides 4 slots to store MAC addresses and the 1st slot is written by FCI.
DA16200 AT GUI Tool 4 Regulatory Approval 4.1 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
DA16200 AT GUI Tool 4.1.4 Manual Information to the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. 4.2 Canada Statement This device complies with Industry Canada’s licence-exempt RSSs.
DA16200 AT GUI Tool Revision History Revision Date Description 1.0 03-Jul-2019 Preliminary DRAFT Release User Manual CFR0012 Revision 1.
DA16200 AT GUI Tool Status Definitions Status Definition DRAFT The content of this document is under review and subject to formal approval, which may result in modifications or additions. APPROVED or unmarked The content of this document has been approved for publication.