Control unit 900 Series mounting + operating
1 Overview This control unit is designated to operate an electrically driven bed with optional comfort functions. • Power supply is provided via SMPS so the control box has protection class III. • The system is operated with an RF remote. The RF receiver is integrated into the control unit.
2 Mounting the control unit This mounting bracket is fixed on the flipside of the bed These two bolts fix the position of the control unit between the mounting bracket.
Control Unit 258-4 2.
Performance data control unit Duty cycle 2/18 min.
Integrated RF receiver 1 Key 1 Function Pairing enable Performance data RF receiver modulation GFSK Frequency Range 2.403~2.480GHz Battery 30V supply voltage Working Current <60mA Standby Current <20mA Ambient Temperature -40—85Ԩ PCB Material & Size October 31, 2012 FR4 1.
2.2 Power supply 3.00.209.033.00 Connecting cable73178 to control box Power supply cable 3.00.401.151.
Remote Control 258D Frontside Key 1 2 4 Function 1 Massage Head + 2 Massage timer ON/OFF 3 Massage Foot + 3 5 6 7 8 9 10 4 Massage Head - 11 12 13 5 Start all Massage 14 15 16 6 Massage Foot - 7 Relay 1 on 8 Relay 3 on 9 Relay 2 on 10 Relay 4 on 11 Relay 5 on 12 Position Zero G 13 Relay 7 on 14 Relay 6 on 15 Light ON/OFF 16 Relay 8 on 17 Position All flat 18 Position Lounge 19 Position TV/PC 20 Pairing 17 18 19 Pairing button & battery box (flip
Performance data remote (RF transmitter) Modulation GFSK Frequency Range 2.403~2.480GHz Battery AAA Working Current <40mA Standby Current <8uA Ambient Temperature -40—85Ԩ RC Dimension 145*50*14mm PCB Material & Size FR4 1.
3 Board Schematics (remote) 3.1 Remote 3.
4 Functional Description Take cable 3.00.401.151.30 and connect it to mains supply. The system is delivered paired! You can test the functions of the system with the RF remote. Pairing instruction (in case of trouble) Pairing the remote with the control box. The distance between remote and control box for pairing should be less than 2 meters! 1. Remove the battery cover on the flipside of the remote. 2. Insert/check existing 3x AAA batteries. 3.
FCC Warning: z This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: z (1) this device may not cause harmful interference, and z (2) this device must accept any interference received, including interference that may cause undesired operation. z Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.