Manual Page 1 of 32 AL-512-00-902 IP-EnOcean-Bridge PoE V1 Ethernet to EnOcean Interface – EnoDisc® EnOcean 902 MHz Part no. 12395 Version 1.12, valid since FW/HW 2.0 / 1.0 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.2021 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change info@deuta-controls.de; www.deuta-controls.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 2 of 32 © 2021 DEUTA Controls GmbH All rights reserved This Manual, including all figures and illustrations, is copyright-protected. Any further use of this Manual by third parties that violate pertinent copyright provisions is prohibited. Reproduction, translation, electronic and phototechnical filing/archiving (e.g., photocopying) as well as any amendments require the written consent of DEUTA Controls GmbH, Bergisch Gladbach, Germany.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 3 of 32 Table of Contents 1 Validity of this documentation ......................................................................................... 5 2 Intended use .................................................................................................................. 5 3 Disposal ......................................................................................................................... 5 4 Device description .....
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual 7.3.5 7.4 Page 4 of 32 Add or remove rules for the repeater .................................................................15 “Setup” / Ethernet and EnOcean interface properties ............................................16 7.4.1 Password ..........................................................................................................16 7.4.2 Device properties ............................................................................
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 5 of 32 1 Validity of this documentation This documentation is only applicable to the product AL-512-00-902 IP-EnOcean-Bridge PoE V1 / EnoDisc® and is only applicable starting from products with FW/HW Version 2.0/1.0. The device must only be installed and operated according to the instructions in this document.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 6 of 32 The standardized protocol used by the communication layer is the ESP3 format (EnOcean Serial Protocol Version 3). The EnoDisc does not interpret data. The EnoDisc is supplied via PoE (Power Over Ethernet). 4.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 7 of 32 5 Technical data 5.1 Communication / EnOcean wireless interface Type EnOcean Number 1 Transmit / receive center frequency 902.875 MHz Maximum transmission power +94 dBµV/m Table 1: Technical data / Wireless communication EnOcean 5.2 Communication / Ethernet interface Type Ethernet, 10/100 Mbit Number 1 Galvanically isolation Ethernet / PoE Ethernet: Yes / PoE: No Table 2: Technical data / communication 5.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual 5.6 Page 8 of 32 Environmental conditions Operating temp. 0° .. +45 °C Storage temp. -20° ..+70 °C Rel. humidity 10..95 % rel. humidity, non condensing Protection class IP20 Table 6: Technical data / environmental conditions 5.7 Dimensions and weight Weight 95 g Dimensions Diameter: 110 mm, Height: 58 mm Table 7: Technical data / dimensions and weight 5.8 Approvals FCC Rule parts 15.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 9 of 32 6 Functional description in detail 6.1 Receiving and transmitting of EnOcean data, and transfer in ESP3 format EnOcean data will be received and transmitted by the EnOcean transceiver and an integrated PCB antenna. Once connected to the EnoDisc via Ethernet TCP on port 8424, data will be sent by / can be received by the EnoDisc®. Note: The Ethernet connection will be closed after 10 seconds without any data transfer.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 10 of 32 7 The EnoDisc® webserver To support system installation and maintenance, the EnoDisc provides an integrated Webserver. The available functions are described below. 7.1 “Home” / EnoDisc device info page On this page, the main properties of the EnoDisc are shown (Read only, can not be changed): • • • • • • • • • • • 7.2 Free text / device name Serial number / part nr.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual • • • • • • • • • • • 7.3 Page 11 of 32 Consecutive number of messages in the list Direction (receive / transmit) EnOcean-ID RORG Data Optional data Repeater level RSSI [dbm] Target address Time elapsed since last message Time stamp “Repeater” / EnOcean repeater configuration The EnoDisc allows to activate an EnOcean repeater (selective) if needed. By default, the repeater is disabled.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 12 of 32 Figure 1: Repeater mode selection 7.3.2 Repeater / Action If an “OR” or an “AND” filter mode is selected (Level 1 or Level 2), you can define if the rule will force (“Repeat”) or explicitly avoid (“Do not repeat”) to repeat the selected telegram type. Figure 2: Repeater mode selection / Action force or block © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 13 of 32 7.3.3 Repeater / Criterium Any repeater rule can be defined based on the properties of a received EnOcean message. The possible options are as follows: Source address Only messages from this source address (EURID) will be repeated. Telegram type Only messages of the selected message type will be repeated. Minimum signal strength (dBm) Messages must have at least the selected signal strength to be repeated.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 14 of 32 Criterium Value Destination address EURID in HEX (0xnnnnnnnn) Telegram type -90 .. -50 dBm, selected by the slider Minimum signal strength (dBm) Source address EURID in HEX (0xnnnnnnnn) Table 10: Repeater criterium Figure 4: Repeater / Value dropdown for telegram type © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 15 of 32 Figure 5: Repeater criterium value signal strength Figure 6: Repeater criterium value source / destination address 7.3.5 Add or remove rules for the repeater Using the “+” and “-“ buttons, you can add or remove rules from the list. © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual 7.4 Page 16 of 32 “Setup” / Ethernet and EnOcean interface properties 7.4.1 Password The page is password protected, to avoid any unwanted change of the device parameters. The password is dynamic, and is based on the system time The password is defined as follows: System time of the PC = hh:mm Password to enter = mm:hh Note: The colon is part of the password and must be entered. Figure 7: Password protection © DEUTA Controls GmbH Paffrather Str.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 17 of 32 7.4.2 Device properties On this page, user can edit the following wireless and wired interface parameters: • • • • • • Free text / device name DHCP or Static IP address IP address Subnet mask Gateway Sensitivity of EnOcean receiver: -90 .. -102 dbm (default: -96 dbm) 7.4.2.1 Freetext To identify the device, a free text can be entered (up to 19 characters). © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 18 of 32 7.4.2.2 DHCP The EnoDisc® supports DHCP or a static assigned address. Depending on the Drop down list selection, DHCP mode is activated or not. Figure 8: Select DHCP or static IP address 7.4.2.3 IP / Netmask / Gateway When “Static” is selected in the drop down list, the static IP address, netmask and gateway address can be changed. To store, the according button has to be pressed once.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 19 of 32 7.4.2.4 EnOcean receiver sensitivity By default, a sensitivity of -96 dBm has been configured for the EnOcean receiver as the factory default. This provides the best performance in most of the applications.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 20 of 32 Figure 11: Start firmware update dialog / enter bootloader After the button has been pushed, EnoDisc will enter into bootloader mode. Progress will be shown (0..100%). Figure 12: EnoDisc entering bootloader mode When bootloader mode has been started, the page will show the actual properties, and also the actual firmware version. © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 21 of 32 Figure 13: EnoDisc in bootloader mode If a new firmware should be loaded, select the new bin-file from your PC, and push the button “Update”. To exit from the bootloader, you can push “Cancel” at any time. Figure 14: Start firmware update © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 22 of 32 Figure 15: Firmware update in progress When the firmware update has been processed correctly, the EnoDisc will start in normal mode automatically. You can check for the new SW version in the table shown on the page “Home”. Figure 16: Firmware updated with success © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 23 of 32 7.4.2.6 Mailbox for EnOcean SmartAck devices The EnoDisc supports the SmartAck mechanism as defined by the EnOcean specification. 7.5 Supported EEP’s (EnOcean Equipment Profiles) 7.5.1 Transmit / TX and Receive / RX The EnOcean wireless standard defines so called EnOcean Equipment Profiles (EEP). Each EnOcean based product sends and receives data according to at least one standardized data format.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 24 of 32 8 Installation and maintenance / service Caution: When opening the device, you have to take care of electrostatic discharge. Otherwise, electronics will be damaged. The following picture shows the parts of an EnoDisc: • • • Socket Connector board / lower part of housing Controller board / upper part of housing To mount the EnoDisc to the ceiling, you have to mount the socket first.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 25 of 32 Dismantle the Ethernet cable as required. Start to mount the interface with the LSA connector board. Connect / mount the two housings with a rotation of approx. 10°. Use an LSA tool to setup the electrical connection. Take care to connect cable according to the colours as marked on the connector. © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 26 of 32 Connect the controller board of the EnoDisc® with the Connector board. Close the housing. © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.2021 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change info@deuta-controls.de; www.deuta-controls.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 27 of 32 9 Device labels The following labels are placed on the housing of the AL-512-00-902 IP-EnOcean-Bridge PoE V1: FCC ID: 2AZTH-AL-512-00-902 HVIN: 1.0 PMN: AL-512-00-902 IC: 27242-51200902 FVIN: 2.0 48 V DC / PoE RoHS AL-512-00-902 IP-ENOCEAN-BRIDGE POE / LSA / EnoDisc / PN: 12395 Made in Germany MAC-Address: 00:00:00:00:00:00 SN: 0000026177 © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 28 of 32 10 FCC (United States) Regulatory Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 29 of 32 L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1. L’appareil ne doit pas produire de brouillage; 2.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 30 of 32 12 Dimensions / drawings Diameter: 110 mm; Height: approx. 38 mm when mounted © DEUTA Controls GmbH Paffrather Str. 140, 51465 Bergisch Gladbach Tel.:+49 2202 285 57- 61 14.07.2021 Hauptstraße 76, 32479 Hille Tel: +49 5734 51466 - 0 Technical data might change info@deuta-controls.de; www.deuta-controls.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 31 of 32 13 Ordering information Part name AL-512-00-902 IP-EnOcean-Bridge PoE V1 © DEUTA Controls GmbH Part nr. 12395 Description Bidirectional bridge between EnOcean and Ethernet TCP; power supply by PoE; communication via ESP3 (EnOcean Serial Protocol 3); EnOcean 902 MHz; on-wall housing, three part; colour: white; weight: 95 g, operating temp.: 0°C - 45°C storage temp.
AL-512-00-902 IP-EnOcean-Bridge PoE V1 Product manual Page 32 of 32 List of tables Table 1: Technical data / Wireless communication EnOcean ................................................ 7 Table 2: Technical data / communication .............................................................................. 7 Table 3: Technical data / user interfaces ............................................................................... 7 Table 4: Technical data / housing ........................................