M18 / M30 Cylindrical type transceiver for 1732 series User’s Manual
Federal Communication Commission Interference Statement NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Declaration of Conformity (For European Union) For European Union [EN] Hereby, DENSO WAVE INCORPORATED declares that this equipment (M18/M30 Type Transceiver) is in English compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. [BG] С настоящето, DENSO WAVE INCORPORATED, декларира, че M18/M30 Type Transceiver е в съответствие Bulgarian със съществените изисквания и другитеприложими разпоредби на Директива 1999/5/EC.
NOTICE: This M18/M30 Type Transceiver may be operated in below country: AT CZ FR HR LT PL SI IS HR BE DK BG EE DE IE LU PT ES LI MK GR IT MT RO SE NO TR CY FI HU LV NL SK GB CH LI Properly shielded cables must be used for connection to host computers and / or peripherals in order to meet CE emission limits.
Table of contents Preface Applicable Standards and Regulations About this Manual SAFETY PRECAUTIONS Chapter 1 Outline 1.1 Hardware Configuration 1.2 System Configuration Chapter 2 Hardware Specifications 2.1 M18 Type Transceiver 2.1.1 Components and Functions 2.1.2 External Dimensions 2.1.3 Environmental Specifications 2.2 M30 Type Transceiver 2.2.1 Components and Functions 2.2.2 External Dimensions 2.2.3 Environmental Specifications Chapter 3 Power Supply Specifications 3.
Preface Read this manual thoroughly before using the product to ensure the proper use of the product and its functions. Keep the manual in a convenient location for quick reference. Liability Limitations • DENSO WAVE INCORPORATED does not assume any product liability (including damages for lost profits, interruption of operations, or the loss of business-related information) arising out of, or in connection with, the use of, or inability to use the product.
Applicable Standards and Regulations Standards and Regulations in Other countries Radio Regulations Standards FCC (USA) R&TTE (Europe) EMC Regulations Safety Regulations ✔: Applicable RSS-Gen RSS-210(Canada) EC/R&TTE Directive (Europe) Applicability ✔ *1 ✔ *1 Remarks FCC Part 15 Subpart C M18 FCC ID : PZWAN22R01 M30 FCC ID : PZWAN23R01 EN 302 291-1, -2 n/a ✔ *1 EN 301 489-1, -3 ICES-003 (Canada) EMC Framework (Australia) n/a C-Tick UL (USA) ✔ c-UL (Canada) ✔ UL508(Type4X Indoor Use Only) P
About this Manual • The content of this manual may be subject to change for specification improvement without prior notice. • The reproduction or duplication of the whole or part of this manual is strictly prohibited without prior consent. • Every attempt has been made to ensure that the content of this manual is thorough and up to date, however, we kindly ask that any questionable content, mistakes, or omissions be reported to DENSO WAVE.
SAFETY PRECAUTIONS Be sure to observe the safety precautions. Read through this manual carefully. It will enable you to use the product correctly. Always keep this manual in a handy place for easy reference. Strict observance of these warnings and cautions is a MUST for preventing accidents that could result in bodily injury and property damage. Make sure you fully understand all definitions of these terms and symbols given below before you proceed to the text itself.
Implantable Medical Devices • Avoid using the product near persons with implantable medical device, such as a cardiac pacemaker. A survey conducted on wireless card systems has reported the possibility of affecting or giving unfavorable impact on implantable medical devices. This is a general characteristic of those systems using radio waves, and not a unique feature of DENSO WAVE’s products or this product itself.
Precautions when Handling • Connect the cable to the connector firmly with a clamp. A loose cable could cause a fire or electrical shock. • Replace the damaged cable to a new one, when a connection cable or a device cable are damaged (e.g., exposed or broken lead wires). Failure to comply could cause a fire or electrical shock. • Wiring to the power supply and the upper device must be done correctly in accordance with this manual.
Operating Environments • Never leave the product in places where there are excessively high temperatures, radiant heat, or in places exposed to direct sunlight. Failure to comply could affect the parts, and cause a fire. • Do not use the product in places where there are drastic temperature changes. Failure to comply could cause a malfunction, a fire or electrical shock. • Do not install the product near a motor, an inverter, or a switching power supply.
Chapter 1 Outline 1.1 Hardware Configuration This product line (hereinafter referred to as the Transceiver) is developed for the Rockwell Automation “1732 series” products to read and write the HF (High Frequency) RFID tag. As listed below, two versions of the transceivers are added. type 1.2 model M18 type transceiver 56RF-TR-M18 M30 type transceiver 56RF-TR-M30 Nut, Washer (Attachment) - appearance T.B.
Chapter 2 Hardware Specifications 2.1 M18 Type Transceiver 2.1.1 Components and Functions Power LED Connector Antenna surface Operation LED ・Connector Pin No.
2.1.
2.1.3 Environmental specifications Item 4 Specification Maximum surrounding air temperature rating 70℃ Minimum surrounding air temperature rating -25℃ (With no icing or condensation) Operating Humidity 35 to 95%RH (With no icing or condensation) Storage Temperature -40℃ to +85℃ (With no icing or condensation) Storage Humidity 25 to 85%RH (With no icing or condensation) Insulation Resistance 20MΩ Min. (DC500V Mega) Between connector terminals and case Vibration Resistance 10 to 500Hz, 1.
2.2 M30 Type Transceiver 2.2.1 Components and Functions Power LED Connector Antenna surface Operation LED ・Connector Pin No.
2.2.2 External Dimensions Unit: mm M30×1.
2.2.3 Environmental specifications Item Specification Maximum surrounding air temperature rating 70℃ Minimum surrounding air temperature rating -25℃ (With no icing or condensation) Operating Humidity 35 to 95%RH (With no icing or condensation) Storage Temperature -40℃ to +85℃ (With no icing or condensation) Storage Humidity 25 to 85%RH (With no icing or condensation) Insulation Resistance 20MΩ Min. (DC500V Mega) Between connector terminals and case Vibration Resistance 10 to 500Hz, 1.
Chapter 3 Power Supply Specifications 3.1 Supply Voltage and Current Consumption Item Specification Supply Voltage DC24V (DC10 to 30V, Ripple is less than 1%) Carrier off Current Consumption 10mA at.DC24V (Excluding inrush) M18 type 40mA (Max. 0.1A) at DC24V M30 type 40mA (Max. 0.1A) at DC24V Carrirer on * Power Suplly : UL1310 Class2, IEC61010-1 Limited energy circuit 3.
3.3 Power OFF Duration OFF duration (referred to as “TvccOFF” in the figure) is required to re-power ON. “TvccOFF” must be (1 second) or more. ON duration (referred to as “TvccON” in the figure) is required before sending any command to the transceiver. “TvccON” must be (0.5 second) or more.
Chapter 4 Upper Communication Specifications 4.1 Specifications to communicate with the host device Item Specification Connector M12, 4-pin male connector Communication System Half Duplex (RS-485) Baud Rates 9600/19200/38400/115200bps selectable (Default: 38400bps) Data Length 8bit Stop Bit Length 1bit Error Detection Parity bit even Cable Length Max. 100m (It varies in the cable) Note: ・RS485 Protocol: Switch the command-response mechanism to avoid signal conflict.
4.2 I/F Circuit IF EN S+ CPU Tx D 120ohm S- 4.
Chapter 5 Tag Communication Specifications 5.1 Specifications to communicate with the RF tag The following is the communication specifications between the transceiver and the RFID tag. Item Specification Tag Type ISO/IEC 15693 Communication System Half Duplex Synchronization scheme Bit Synchronization Transceiver ↓ Tag Baud Rate 26.48kbit/s (Carrier:13.56MHz) Modulation Scheme ASK 10 to 30% Modulation code Tag ↓ Transceiver Baud Rate 1 out of 4 OOK 26.
5.3 Communication Area (reference) M18 Type * φ50 tag distance 40mm 60 60 [mm] 50 50 40 40 T.B.D 30 30 20 20 10 10 0 -60 -50 -40 -30 -20 -10 0 -10 0 10 20 30 40 50 60 [mm] -10 -20 -20 -30 -30 -40 -40 -50 -50 -60 -60 0 10 20 30 40 50 60 70 80 90 100 110 M30 Type * φ50 tag 100 distance 60mm 100 [mm] 80 80 60 T.B.
Chapter 6 Installation 6.1 Tightening Torque The tightening torque must be 19.8N・m for M18 nut, and 33.9N・m for M30 nut. Nut Washer 6.2 Surrounding Metal M18 Type: Communication distance will drop significantly when the distance between the transceiver and any surrounding metal is less than 25mm. M30 Type: Communication distance will drop significantly when the distance between the transceiver and any surrounding metal is less than 30mm.
6.3 Interference between the transceivers Installing more than one transceiver causes radio frequency interference and may result in the difficulty of the tag communication. Keep a sufficient distance between the transceivers as shown in the figure below.
Chapter 7 Troubleshooting Examine the cause of the problem by using the flowchart below and take appropriate countermeasures when any problems occur. Check flow Do the operating and environmental conditions comply with the specifications? NO Read “Chapter 2 Hardware Specifications” , and confirm that the transceiver is used in the proper operating and environmental conditions.
M18 type transceiver (56RF-TR-M18) M30 type transceiver (56RF-TR-M30) for 1732 series User’s Manual Ver : 0.92 Jul. 2012 1, Yoshiike, Kusagi, Agui-cho, Chita-gun, Aichi 470-2297, Japan 105-0001 http://www.denso-wave.