DELTA 10 F 03.LDF004.T12 03.LDF004.T25 03.LDF004.T45 03.LDF004.T12.WS 03.LDF004.T25.WS 03.LDF004.T45.WS User’s Manual rel 1.3 GB D.T.S. Illuminazione srl - ITALY http://www.dts-lighting.
DELTA 10 F Le informazioni contenute in questo documento sono state attentamente redatte e controllate. Tuttavia non è assunta alcuna responsabilità per eventuali inesattezze. Tutti i diritti sono riservati e questo documento non può essere copiato, fotocopiato, riprodotto per intero o in parte senza previo consenso scritto della D.T.S . DTS si riserva il diritto di apportare senza preavviso cambiamenti e modifiche estetiche , funzionali o di design a ciascun proprio prodotto. D.T.
DELTA 10 F 3 INDEX: 1- SYMBOLS 2- GENERAL WARNING 3- GENERAL WARRANTY CONDITION 4- TECHNICAL FEATURES 5- ACCESSORIES 6- IMPORTANT SAFETY INFORMATION 4 4 4 5 5 7 6.1 Fire prevention 6.2 Prevention of electric shock 6.3 Protection against direct light radiation 6.4 Safety 6.5 Level of protection against the penetration of solid and liquid matter 7- VOLTAGE AND FREQUENCY 8- INSTALLATION 8 8 8.1 Safety cable 8.2 Protection against liquid 8.3 Movement 8.4 Risk of fire 8.5 Forced ventilation 8.
DELTA 10 F 1- SYMBOLS Graphic symbols used on this manual THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBOL INDICATES ELECTRIC SHOCK RISK ! F 1M THIS SYMBOL INDICATES GENERAL RISK THIS SYMBOL MEANS “DO NOT PLACE THE UNIT ON INFLAMMABLE SURFACES” THIS SYMBOL INDICATES THE MINIMUM DISTANCE TO BE KEPT BETWEEN THE DEVICE AND THE LIT OBJECT 2- GENERAL WARNING Read the instruction contained in this user manual carefully, as they give important information regarding safety during installation , use and m
DELTA 10 F 4- TECHNICAL FEATURES DELTA 10 F RGBW is a new colour changer with LED technology, with a high protection rating (IP65), ideal for use both indoors and outdoors. DELTA 10 F RGBW is the brightest LED colour changer in its category: 8.300 Lux at 5 m. In fact its light source is composed of 240 LEDs (60 x Red, 60 x Green, 60 x Blue, 60 x White) with 19.500 total lumens.
DELTA 10 F 6 4- TECHNICAL FEATURES Power supply / consumption Full range AC 90-260V, 50-60Hz Power consumption: * 90 V – 5,3 A – 480 W * 120 V – 4 A – 480 W * 230 V – 2,1 A – 480 W * 260 V – 1,85 A – 480 W Thermal Operating ambient temperature: -10° / +40° Weight 18Kg Finishes Black, white Certifications and safety CE certification; LED class: Class 2 LED product Dimensions Unit Dimensions (LxWxH) 454x205x443mm Weight: 18 Kg Packaging Dimensions (LxWxH) 630 x 500 x 660 mm Weight: 20 Kg 454 mm 413 mm 44
DELTA 10 F 6- IMPORTANT SAFETY INFORMATION 6.1 Fire prevention: F -Never locate the fixture on any flammable surface. -Minimum distance from flammable materials: 1 m. 1M -Minimum distance from the closest illuminable surface: 1 m. -Replace any blown or damaged fuses only with those of identical value. Refer to the wiring diagram if there is any doubt. -Connect the projector to mains power via a thermal magnetic circuit breaker. 6.2 Prevention of electric shock: -High voltage is present inside the unit.
DELTA 10 F 8 .7- VOLTAGE AND FREQUENCY: Delta 10 F can operate at 90-260VAC, 50 or 60 Hz. 8- INSTALLATION: Delta 10 F may be either floor or ceiling mounted. For floor mounting installations, the unit is supplied with four rubber mounting feet on the base. For ceiling mounted installations, we reccommend the use of appropriate clamps to fix the unit to the mounting surface.
DELTA 10 F 9 8.4- Risk of fire Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended distance from flammable material is 1 MT. F Minimum distance from the object being illuminated is 1 MT. 1M 8.5- Forced ventilation You will note, on inspection, that the unit features various air inlets and cooling fans located on the head of the fixture. These should, under no circumstances, be blocked or obstructed whilst the projector is in operation.
DELTA 10 F 10 10- DMX SIGNAL CONNECTION The unit operates using the digital DMX 512 (1990) signal. Connection between the mixer and the projector or between projectors must be carried out using a two pair screened ø 0.5 mm cable and a XLR 5 or 3 pins connector. Ensure that the conductors do not touch each other. Do not connect the cable ground to the XLR chassy The plug housing must be isolated.
DELTA 10 F 10.1 DMX Addresses: DELTA 10 F can be used in 3 different DMX modes: 10 DMX control channels, 6 DMX control channels or CUSTOM mode channels. Here below is described the DMX channels addressing for the controller when Delta 10 f is set to 10 DMX control channels : Projector Projector Projector ….. projector 1 2 3 6 A001 A011 If you want to select the next projector, just add “10” A021 A…. A051 10.
DELTA 10 F 12 12- DISPLAY FUNCTIONS MENU ENTER DOWN UP DISPLAY FUNCTIONS The DELTA 10 F display panel shows all the available functions . Using these functions, it is possible to change some of the parameters and add some functions. Changing the D.T.S. setting can vary the functions of the unit so that it does not respond to the DMX 512 signal used to control it. Carefully follow the instructions below before carrying out any variations or selections.
DELTA 10 F 13 Default = 0 MENU Up-Down ENTER LED RGBA Min/Max, Smooth, Compression level values settings and Boost mode Up-Down ENTER Up-Down Default = 100 ENTER ENTER Up-Down Default = 0 RGBA MINIMUM VALUES This menu allow to select the minimum levels for Red, Green, Blue and Amber ENTER Up-Down ENTER Default = 100 ENTER Up-Down RGBA MAXIMUM VALUES This menu allow to select the maximum levels for Red, Green, Blue and Amber Default = 0 ENTER Up-Down ENTER Default = 100 These settings
DELTA 10 F 14 MENU Up-Down ENTER ENTER Up-Down ENTER Up-Down ENTER Up-Down ENTER AUTOMATIC MODE Automatic demo game without DMX controller WHITE MACROS 16 macros for White color from 2000 to 7200 ° K DIMMER Dimmer level selectable by user as on DMX channel 2 (Dimmer) Dimmer level is active for all the programs and macros SHUTTER Shutter level selectable by user as on DMX channel 1 (Shutter) Shutter level is active only for CU01/CU16 and Wh01/Wh16 macros ESC Esc from Automatic Mode Menu ENTER M
DELTA 10 F 15 MENU Up-Down ENTER ENTER ENTER Up-Down SLAVE MODE Slave mode for ChPr program. All slave units will be synchronised with master unit, running their own Chpr program. MENU Up-Down ENTER Up-Down ENTER INFRARED MODE Infrared remote control. By activating Ir MODE, it will be possible to navigate trought the unit functions by using the D.T.S. infrared remote control. D.T.S. Code :0514L008 (Not implemented on DELTA 10 F) MENU Up-Down NOTE: External infrared remote sensor needed. D.
DELTA 10 F 16 MENU Up-Down ENTER Up-Down ENTER EMERGENCY Emergency operating mode. By setting Emergency mode, it will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or not available. Usefull for Emergency EXIT ilumination on public areas. MENU Default = White 1 ENTER Default = 255 ENTER ENTER Up-Down Up-Down ENTER ENTER .
DELTA 10 F 17 13-AUTOMATIC OPERATION (AUTO) DELTA 10 F can work in automatic mode without a DMX controller. First of all connect the projectors with a DMX cable (picture below). A maximum quantity of 32 slave units can be connected to the same Master unit. MASTER SLAVE 1 DMX OUT DMX IN SLAVE 32 SLAVE 2 DMX OUT DMX IN DMX OUT DMX IN To activate Auto mode on the first unit, use the menu to run through the different modes until AUTO appears on the display, and press enter.
DELTA 10 F 13.3 Rec mode It is possible to program your own game on DELTA 10 F that will then run it in AUTO mode (ChPr). Each unit can have its own programmed game. In REC mode the unit must be set to 10 channels mode. To program the ChPr by using a DMX controller, you need 3 more channels in addition to the 10 channels necessary to control the unit. So that in RECORDER mode (via DMX) the unit will need 13 DMX channels to be correctly programmed.
DELTA 10 F 19 14- PERIODIC CLEANING Front lenses Glass: The dust can reduce the luminous output substantially. Regularly clean the front lenses glass using a soft cotton cloth, dampened with a specialist glasses cleaning solution. 15- PERIODIC CONTROLS Mechanical parts: Periodically check all mechanical parts and the gaskets, replacing them if necessary. Electrical components: Check all electrical components for correct earthing and proper attachment of all connectors, refastening if necessary.
DELTA 10 F 20 16- REPLACING THE LENSES Spot (12°) as standard not to be removed, Medium flood (25°), Wide flood (45°), Elliptical (15° x 45°) • Lenses set Medium flood (25°) (cod. 03.LK.064) • Lenses set Wide flood (45°) (cod. 03.LK.065) • Lenses set Elliptical (15° x 45°) (cod. 03.LK.
DELTA 10 F 21 17-DMX PROTOCOL 10 CHANNELS MODE (Default) 1 2 3 4 5 6 7 8 9 10 SHUTTER DIMMER RED GREEN BLUE AMBER WHITE (Pre-programmed whites at different colour temperatures) CTC COLOURS MACRO FUNCTIONS DMX CHANNEL 1 DMX range Value Mid point DMX value 0-9 10-19 20-29 30-119 120-149 150-179 180-204 205-229 230-255 5 14 24 Parameter: SHUTTER Move range (degrees) Mode Option Black-out Open Black-out Strobe at variable speed from slow to fast (3400ms-20ms) Pulse open at variable speed from slow
DELTA 10 F 22 DMX CHANNEL DMX range Value 4 Parameter: GREEN Mid point DMX value Move range (degrees) Mode Option 0-255 DMX CHANNEL DMX range Value Proportional colour 5 Parameter: BLUE Mid point DMX value Move range (degrees) Mode Option 0-255 DMX CHANNEL DMX range Value Function Proportional colour 6 Parameter: AMBER Mid point DMX value Move range (degrees) Mode Option 0-255 DMX CHANNEL Function Function Proportional colour 7 Parameter: WHITE (Pre-programmed White at diff.
DELTA DELTA R 10 F 23 DMX CHANNEL DMX range Value 8 Parameter: CTC (Color temperature correction) Mid point DMX value Move range (degrees) Mode Option Function IF CHANNEL 7 (White) = WHITE CTC (Dmx range value 206 - 255) 0-255 43 color temp.
DELTA 10 F 24 DMX CHANNEL IF: MENU Up-Down DMX range Value Parameter: COLOUR MACROS 9 ENTER Up-Down Mid point DMX value Move range (degrees) Mode ENTER Option PLEASE CHECK PAGE 12 Function No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Macro 10 Macro 11 Macro 12 Macro 13 Macro 14 Macro 15 Macro 16 Rainbow Speed 1 (1 Sec.) Rainbow Speed 2 (5 Sec.) Rainbow Speed 3 (10 Sec.) Rainbow Speed 4 (20 Sec.) Rainbow Speed 5 (30 Sec.) Rainbow Speed 6 (60 Sec.
DELTA 10 F 25 6 CHANNELS MODE 1 2 3 4 5 6 SHUTTER DIMMER RED GREEN BLUE AMBER DMX CHANNEL 1 DMX range Value Mid point DMX value 0-9 10-19 20-29 30-119 120-149 150-179 180-204 205-229 230-255 5 14 24 Parameter: SHUTTER Move range (degrees) Mode Option Black-out Open Black-out Strobe at variable speed from slow to fast (3400ms-20ms) Pulse open at variable speed from slow to fast (43s-100ms) Pulse close at variable speed from slow to fast (43s-100ms) Random Strobe (Master and RGBA active) Random
DELTA 10 F 26 DMX CHANNEL DMX range Value 4 Parameter: GREEN Mid point DMX value Move range (degrees) Mode Option 0-255 DMX CHANNEL DMX range Value Proportional colour 5 Parameter: BLUE Mid point DMX value Move range (degrees) Mode Option 0-255 DMX CHANNEL DMX range Value 0-255 Function Function Proportional colour 6 Parameter: AMBER Mid point DMX value Move range (degrees) Mode Option Function Proportional colour
NOTE DELTA 10 F
The information contained in this publication has been carefully prepared and checked. However, no responsibility will be taken for any errors. All rights are reserved and this document cannot be copied, photocopied or reproduced, in part or completely, without prior written consent from D.T.S.. D.T.S. reserves the right to make any aesthetic, functional or design modifications to any of its products without prior notice. D.T.S.