50-870 PART NO. 410-10-651-0001 - 03-31-02 Copyright © 2002 Delta Machinery To learn more about DELTA MACHINERY visit our website at: www.deltamachinery.com. For Parts, Service, Warranty or other Assistance, please call ESPAÑOL: PÁGINA 11 1-800-223-7278 (In Canada call 1-800-463-3582).
GENERAL SAFETY RULES Woodworking can be dangerous if safe and proper operating procedures are not followed. As with all machinery, there are certain hazards involved with the operation of the product. Using the machine with respect and caution will considerably lessen the possibility of personal injury. However, if normal safety precautions are overlooked or ignored, personal injury to the operator may result.
SAFETY RULES FOR AIR CLEANERS 1. DANGER: DO NOT USE THIS UNIT TO FILTER METAL DUST. Combining wood and metal dust can create an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only. 2. WARNING: DUST GENERATED BY CERTAIN WOODS AND WOOD PRODUCTS CAN BE HAZARDOUS TO YOUR HEALTH. 3. WARNING: DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE. This air cleaner is intended for use where only dry airborne dust is present.
INTRODUCTION Model 50-870 Delta Air Cleaner is specifically designed to quietly circulate and filter non-metallic dust which is generated throughout the work area. The Air Cleaner is furnished with two filters: a disposable outer filter which filters out larger particles five microns in size; and the secondary filter will capture 91% of dust particles of one micron in size (one micron = one millionth of a meter).
ASSEMBLY INSTRUCTIONS Determine whether the Air Cleaner will be used on the floor, on a bench, or hanging from overhead. If the Air Cleaner will be used as a mobile unit, proceed to “USING THE AIR CLEANER ON A BENCH OR FLOOR SURFACE” section. If ceiling mounting is desired, proceed to section “MOUNTING THE AIR CLEANER TO A CEILING OR OVERHEAD SUPPORT.” IMPORTANT: When determining where to mount the air cleaner, always select a location where the air flow is unrestricted.
MOUNTING THE AIR CLEANER TO THE CEILING OR OVERHEAD SUPPORT WARNING:This unit weighs 85 pounds. When mounting overhead, make certain that the unit is securely fastened and supported. D 1. Locate the four 1” eye-bolts, and the four 1/4-20 flange nuts supplied with the unit. 2. Use a 5/32” Allen wrench to remove the four screws (C) Fig. 5 from the top of the air cleaner (D). C 3. Thread one flange nut on the eyebolt until approximately 3/4 of the bolt is exposed. 4.
GROUNDING INSTRUCTIONS WARNING: THIS TOOL MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELECTRIC SHOCK. 2. Grounded, cord-connected tools intended for use on a supply circuit having a nominal rating less than 150 volts: 1. All grounded, cord-connected tools: In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock.
EXTENSION CORDS MINIMUM GAUGE EXTENSION CORD RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC TOOLS Ampere Rating 0-6 0-6 0-6 0-6 6-10 6-10 6-10 6-10 10-12 10-12 10-12 10-12 12-16 12-16 12-16 Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3-prong grounding type plug and a 3-hole receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the saw.
OPERATIONS NOTE: The air cleaner may produce a slight odor for the first few hours of operation due to the protective coating that is applied to internal components. This odor will dissipate and should be disregarded. IMPORTANT: Never operate the air cleaner without air filters in place. The Delta 50-870 air cleaner can be used in • • • • • • bench-top sanding applications. circular sawing applications. dry wall applications. shop cleaning applications. floor sanding applications.
ACCESSORIES A complete line of accessories is available from your Delta Supplier, Porter-Cable • Delta Factory Service Centers, and Delta Authorized Service Stations. Please visit our Web Site www.deltamachinery.com for a catalog or for the name of your nearest supplier. WARNING: Since accessories, other than those offered by Delta, have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Delta recommended accessories should be used with this product.
PORTER-CABLE • DELTA SERVICE CENTERS (CENTROS DE SERVICIO DE PORTER-CABLE • DELTA) Parts and Repair Service for Porter-Cable/Delta Power Tools are Available at These Locations (Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable•Delta) ARIZONA Tempe 85282 (Phoenix) 2400 West Southern Avenue Suite 105 Phone: (602) 437-1200 Fax: (602) 437-2200 CALIFORNIA Ontario 91761 (Los Angeles) 3949A East Guasti Road Phone: (909) 390-5555 Fax: (909) 390-5554 San Leandro 9