Federal communications commission (FCC) Statement This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications.
IMPORTANT SAFETY INSTRUCTIONS |. SEE INSTALLATION INSTRUCTIONS BEFORE CONNECTING TO THE SUPPLY. it. THE APPLIANCE COUPLET iS CONSIDERED AS A DISCONNECT DEVICE. SHALL BE CONNECTED AS CLOSELY AS PRACTICABLE TO THE INCOMING SUPPLY. Il. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE. IV. REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. V.
TABLE OF CONTENTS (INTRODUCTION... [ROPERS O PPO INSTALLATION INSTRUCTIONS. CONTROLS AND OPERATION. caver 9210 SPECIFICATIONS... ins 11 14 INPUT PIN ASSIGNMENT coon TIMING CHART.
INTRODUCTION Our monitors is high resolution color monitors for use with BM PC/XT/AT and PS/2 computers or compatibles with analog RGB output. The monitors support timings of graphics adapters including: VGA, super VGA, XGA, 1024 x 768 and 1280 x 1024. FEATURES Automatically scan horizontal and vertical frequencies. Analog input sigma! provides the capability of unlimited display colors. Auto sizing and auto centering between modes of graphics standards.
INSTALLATION INSTRUCTIONS CAUTION: Be sure to turn off the AC Power to the monitor before making connections 1. Assembie the tilt/swivel base as shown below. 2 Connect the power cord as shown on page 8. 3.
USING THE RIGHT POWER CORD FOR 230VAC For units used at 120V:Use a UL Listed cord set consisting of a minimum NO.18 AWG, Type SVT or SJT, rated 6A minimum 125V, three-conductor cord a maximum of 15 fin length and a parallel blade, grounding type attachment plug. For units used at 230V (domestic use): Use a UL Listed cord set consisting of a minimum No. 18 AWG, Type SVT or SJT, rated 3A minimum 250V, three conductor cord a maximum length and a tandem blade, grounding type attachment plug.
CONT RATION 1. TILT/SWIVEL BASE Tum the monitor for comfortable viewing angle within 180 degrees horizontally and 20 degrees vertically. (Please refer to instructions on bottom of rear cover for installation ) 2. SIGNAL INPUT CONNECTOR (15-pin mini D-SUB) Connect to the display adapter output of a computer having analog video output. (Please see installation instructions.) 3. AC INPUT CONNECTOR {Appliance couplet) Connect to AC outlet with supplied power cord. 4.
OSD MANUAL VOLUME (AUDIO MODEL ONLY) BASIC + HORIZONTAL SIZE + HORIZONTAL POSITION « VERTICAL SIZE + VERTICAL POSITION « DEGASSED « V.MOIRE GEOMETRY + PINCUSHION + TRAPEZOID + PARALLEL + ROTATION COLOR + 9300K / 6500K + R.G.B STATUS RECALL + BASIC & GEOMETRY COLOR EXIT NOTE: 1. To enter OSD : Push “ MENU ” bottom. 2. To exit OSD: 1. Push * MENU“ +" J * two keys simultaneously or 2. Select “ exit“ and push an adjusting button 3.
POWER MANAGEMENT THIS MONITOR CAN SUPPORT VASE POWER MANAGEMENT SYSTEM, INDICATED BY THE LED ON THE FRONT PANEL: STATE LED POWER COLOR CONSUMPTION ON GREEN 75W STANDBY/ AMBER <15W SUSPEND ACTIVE OFF AMBER < 8W The monitor remains in the power-saving state until you press a key on the keyboard or move the mouse (if available). DISPLAY DATA CHANNEL (DDC) COMMUNICATION CHANNEL TYPE: VASE DDC1/2B. ESTABLISHED TIMINGS: AS PRESET TIMING CHARTS.