Whitepaper SFP Optical Transceiver Inventory and Monitoring using NC-SI Abstract iDRAC monitor SFP optical transceivers that are plugged into the SFP port of a network device. All SFP optical transceivers are hot pluggable and provide fiber connectivity to the network hardware. SFPs support high-speed connectivity and extended cable lengths.
Revisions Revisions Date Description January 20, 2020 Initial release Acknowledgements This paper was produced by the following: Author: Srinivasa Rao Mareedu Support: Deepa Ganesh, Rama Bisa Other: Mondeep Dutt The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose.
Table of contents Table of contents Revisions............................................................................................................................................................................. 2 Acknowledgements ............................................................................................................................................................. 2 Table of contents ...............................................................................................
Executive summary Executive summary iDRAC inventories and monitors SFP optical transceivers and delivers diagnostic information on the device to the user across iDRAC interfaces. A transceiver plugs into the SFP (Small Form-factor Pluggable) port of a network device on one end and connects to Fiber Channel/Gigabit Ethernet (GbE) optical fiber cables on the other end.
1 SFP optical transceiver inventory and monitoring using NC-SI This document provides information on iDRAC inventory and monitoring of supported SFP optical transceivers that are already plugged into network device SFP ports. SFP transceiver data is shared across all iDRAC user interfaces. SFF-8472 specification defines SFP transceiver diagnostic information which contains manufacture and sensor information.
Types of SFP transceivers Types of media 6 SFP Optical Transceiver inventory and monitoring using NC-SI | ID348
Configuration and deployment The following section provides validated configuration and deployment platform information. 1.2.1 Validated configurations: • • iDRAC release version 4.00.00.
H914R J471J MW6JV CK9H1 G620Y X1TD1 2J3X7 NV5DW 47W4V R6D8Y YGW92 0MF05 KN139 7RC9T 4G6WF 91XY2 6CWM6 31KFT W0RM9 K6V3V 6W1HY R887V 71C1T HHX1W R76FD • • 1.2.
1.2.3 GUI behavior SFP inventory and sensor information 1.2.4 9 Use cases Identify manufacture and sensor information of the SFP transceiver.
2 Glossary Acronym AOC CNA DAC DMTF FC HBA iDRAC NCSI NDC NIC QSFP QSFP+ QSFP28 QSFP-DD RJ-45 SFP SFP+ SFP28 SFP-DD Definition Active Optical Cable Converged Network Adapter Direct Attach Copper Distributed Management Task Force Fiber Channel Host Bus Adapter Integrated Dell Remote Access Controller. Network Controller Sideband Interface Network Daughter Controller Network Interface Card Quad (4-channel) Small Form-factor Pluggable. Quad (4-channel) Small Form-factor Pluggable Plus.