Setup Guide

Fibre Channel and iSCSI Cabling
To maintain continuous connectivity to stored data from the host server, implement a strategy for redundant I/O paths.
Fibre Channel 2 Port 16 Gb Configuration
iSCSI 2 Port 10 GbE Configuration
1. Connect each host server to both switches.
– Connections shown in orange belong to fault domain 1.
– Connections shown in blue belong to fault domain 2.
2. Connect fault domain 1 (in orange) to switch 1.
– Top storage controller: port 1 to switch 1
– Bottom storage controller: port 1 to switch 1
3. Connect fault domain 2 (in blue) to switch 2.
– Top storage controller: port 2 to switch 2
– Bottom storage controller: port 2 to switch 2
Fibre Channel 4 Port 8 Gb Configuration
iSCSI 4 Port 1 GbE Configuration
1. Connect each host server to both switches.
– Connections shown in orange belong to fault domain 1.
– Connections shown in blue belong to fault domain 2.
2. Connect fault domain 1 (in orange) to switch 1.
– Top storage controller: port 1 to switch 1
– Top storage controller: port 3 to switch 1
– Bottom storage controller: port 1 to switch 1
– Bottom storage controller: port 3 to switch 1
3. Connect fault domain 2 (in blue) to switch 2.
– Top storage controller: port 2 to switch 2
– Top storage controller: port 4 to switch 2
– Bottom storage controller: port 2 to switch 2
– Bottom storage controller: port 4 to switch 2
Setting Up Your Dell SCv2000 and SCv2020 Storage System
Warning! Before you set up and operate your Dell system, review the safety
instructions that came with your system.
Warning! The storage system chassis is heavy. Do not attempt to
lift the chassis without assistance.
Use the racking instructions included with your package to rack the chassis.
Mount the storage system chassis and expansion enclosures in a manner that allows
for expansion in the rack and prevents the rack from becoming top-heavy. Secure the
storage system chassis to the rack using the mounting screws that are located behind
the latches on each chassis ear.
1 2Before You Begin Rack Chassis and Optional Enclosures
Unpack Storage Center Equipment
A Dell SCv2000 and SCv2020 includes:
Storage system chassis
Drives (shipped inside chassis)
Mounting rails (2)
Bezel
Getting Started Guide
Develop a Configuration Plan
Before installing the storage hardware, develop a configuration plan where you can record host
server information, switch information, and VLAN information.
Record system information on the worksheet in the Getting Started Guide
System management IPv4 address for Storage Center
MGMT port IPv4 address for each storage controller
Domain name
DNS server address
Consider Plans for Multipath/Failover
Redundancy is provided by fault domains, which allow alternate paths if a path fails. Fault domains
are determined by the number of independent Fibre Channel (FC) fabrics or iSCSI networks. Each
switch carries a separate fault domain. If a port fails, any port within the same fault domain takes
over for the failed port. Dell recommends using multipathing, so that volumes are mapped to ports
in more than one fault domain.
More Information
For operating system, host bus adapter (HBA) and switch requirements, see the Dell Storage
Compatibility Matrix on the Dell Tech Center at http://en.community.dell.com/techcenter/storage.
For additional deployment instructions, see the Dell Storage Center SCv2000 and SCv2020
Storage System Deployment Guide on dell.com/support.
SCv2000 and SCv2020 storage systems support Fibre Channel, iSCSI, and SAS protocols to connect the Storage Center to host servers. Fault domains provide fault tolerance at the controller level. If you are using Fibre
Channel, incorporate your switch zoning strategy with the fault domains. Dell recommends using redundant cabling to avoid a single point of failure.
To connect the storage system:
1. Identify the protocol being used to connect the host servers to the storage system.
2. Refer to the diagram below that corresponds to the proper protocol. These cabling guidelines ensure the configuration has redundancy and failover capability.
For more information about cabling, see the Dell Storage Center SCv2000 and SCv2020 Storage System Deployment Guide.
Fault domain 1
Fault domain 2
4
Prepare the Host Servers
5
Cable the Host Servers
Refer to the Dell Storage Compatibility Matrix for a list of supported HBAs or iSCSI network adapters.
Windows and Linux Hosts
Install the HBAs or network adapters, install the drivers, and make sure that the latest supported BIOS is
installed.
Fibre Channel
1. Install Fibre Channel HBAs in the host servers.
2. Install supported HBA drivers and make sure that HBAs have the latest supported firmware.
3. Use the Fibre Channel cabling diagrams to cable host servers to switches. Connecting host servers
directly to the storage system without using Fibre Channel switches is not supported.
iSCSI
1. Install iSCSI HBAs or network adapters dedicated for iSCSI traffic in the host servers.
2. Install supported HBA drivers and make sure that HBAs have the latest supported firmware.
3. Use the iSCSI cabling diagrams to cable the host servers to switches. Connecting host servers directly
to the storage system without using Ethernet switches is not supported.
4. Assign IP addresses to each iSCSI port to match the subnets for each fault domain.
CAUTION: Make sure to assign the correct IP addresses to the HBAs or network adapters. Assigning IPs
to the wrong ports can cause connectivity issues.
NOTE: If using jumbo frames, enable and configure jumbo frames on all devices in the data path: adapter
ports, switches, and storage system.
SAS
1. Install SAS HBAs in the host servers.
2. Install supported HBA drivers and make sure that HBAs have the latest supported firmware.
3. Use the SAS cabling diagram to cable the host servers directly to the storage controllers.
VMware ESXi Hosts
Install the HBAs or network adapters and make sure that the latest supported BIOS is installed.
Fibre Channel
1. Install Fibre Channel HBAs in the ESXi hosts.
2. Use the Fibre Channel cabling diagrams to cable ESXi hosts to switches. Connecting ESXi hosts directly
to the storage system without using Fibre Channel switches is not supported.
iSCSI
1. Install iSCSI HBAs or network adapters dedicated for iSCSI traffic in the ESXi hosts.
2. If using network adapters, create a VMkernel port for each adapter. (One VMkernel per vSwitch)
3. Assign IP addresses for each adapter port to match the subnets for each fault domain.
CAUTION: Make sure to assign the correct IP addresses to the HBAs or network adapters. Assigning IPs
to the wrong ports can cause connectivity issues.
NOTE: If using jumbo frames, enable and configure jumbo frames on all devices in the data path: adapter
ports, switches, and storage system.
4. If using network adapters, add the VMkernel ports to the iSCSI software initiator.
5. Use the iSCSI cabling diagrams to cable the ESXi hosts to switches. Connecting ESXi hosts directly to
the storage system without using Ethernet switches is not supported.
SAS
1. Install SAS HBAs in the ESXi hosts. For more information about configuring VMware ESXi hosts with
SAS HBAs, see the Dell Storage Center SCv2000 and SCv2020 Storage System Deployment Guide.
2. Use the SAS cabling diagram to cable the ESXi hosts directly to the storage controllers.
NOTE: Configure only one ESXi host at a time.
1. Hold the bezel with the Dell logo upright.
2. Hook the right end of the bezel into the right side of the storage
system chassis.
3. Swing the left end of the bezel toward the left side of the storage
system chassis.
4. Press the bezel into place until the release latch closes.
5. Use the key to lock the front bezel.
3 Install the Bezel
SAS Cabling
Directly connect host servers to a storage system.
SAS 4 Port 12 Gb Configuration
1. Connect fault domain 1 (in orange) to server 1.
– Top storage controller: port 1 to port on server 1
– Bottom storage controller: port 1 to port on server 1
2. Connect fault domain 2 (in blue) to server 2.
– Top storage controller: port 2 to port on server 2
– Bottom storage controller: port 2 to port on server 2
3. Connect fault domain 3 (in gray) to server 3.
– Top storage controller: port 3 to port on server 3
– Bottom storage controller: port 3 to port on server 3
4. Connect fault domain 4 (in red) to server 4.
– Top storage controller: port 4 to port on server 4
– Bottom storage controller: port 4 to port on server 4

Summary of content (2 pages)