ãŠãŒã¶ãŒãºã¬ã€ã ã€ãŒãµããã iSCSI ã¢ããã¿ããã³ ã€ãŒãµããã FCoE ã¢ããã¿ QLogic BCM57xx ããã³ BCM57xxx BC0054508-04 J ãµãŒ ã ããŒã 㣠æ
å ±ã¯ Dell ã® ãåæã«ã 㣠ãŠæäŸ ã ãã ãã®ã§ãã
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx ææžæ¹èšå±¥æŽ 2015 幎 2 æ 18 æ¥ã 㪠ã 㞠㧠㳠A 2015 幎 7 æ 29 æ¥ã 㪠ã 㞠㧠㳠B 2016 幎 3 æ 24 æ¥ã 㪠ã 㞠㧠㳠C 2016 幎 4 æ 8 æ¥ã 㪠ã 㞠㧠㳠D 2017 幎 2 æ 2 æ¥ã 㪠ã 㞠㧠㳠E 2017 幎 8 æ 25 æ¥ã 㪠ã 㞠㧠㳠F 2017 幎 12 æ 19 æ¥ã 㪠ã 㞠㧠㳠G 2018 幎 3 æ 15 æ¥ã 㪠ã 㞠㧠㳠H 2018 幎 4 æ 13 æ¥ã 㪠ã 㞠㧠㳠J å€æŽ 察象ç®æ æé 1 ãå€æŽã xxi ããŒãžã® ã ã ã 㥠㡠㳠ã ã®ããŠã³ ã㌠ã ã Linux ããã³ Windows äžã® NPIV ã®ãµã㌠ã ïŒã ã¡ ã€ããŒã 㣠ãã«çµç± - 㪠㳠ã¯ãµãŒã ã¹ä»æ§ïŒ ãè¿œå ã 4 ããŒãžã® ãFCoEã æåã®ãã© ã° ã© ã
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx enable_live_grcdump ã㩠㡠㌠㿠ãè¿œå ã 64 ããŒãžã® ãenable_live_grcdumpã Windows 2016 ã®ãµã㌠ã ãè¿œå ã 72 ããŒãžã® ã ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã«ã ïŒ2 çªç®ã® ã¡ ã¢ïŒã 73 ããŒãžã® ã〠㳠㹠ã ㌠ã©ã®äœ¿çšã ïŒè¡š 9-1ïŒã 99 ããŒãžã® ãWindows Server 2012ã 2012 R2ã ããã³ 2016 iSCSI ã㌠ã ã» ã ã 㢠ã ããã 209 ããŒãžã® ãæŠèŠãã 223 ããŒãžã® ãWindows Server 2012ã 2012 R2ã ããã³ 2016 FCoE ã㌠ã 〠㳠㹠ã ãŒã«ãã 254 ããŒãžã® ãWindows Server 2012 以éã®ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã°ãã 295 ã㌠ãžã® ãHyper-V ãäœ¿çš ã
ç®æ¬¡ ã¯ããã« .. .. .. .. .. .. . . . . . . .. .. .. .. .. .. .. .. .. .. .. .. . . . . . . .. .. .. .. .. .. .. .. .. .. .. .. . . . . . . .. .. .. .. .. .. . . . . . . .. .. .. .. .. .. . . . . . . xix xix xx xx xxi xxii æ©èœã®èª¬æ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . æ©èœ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iSCSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 4 ããŒããŠã§ã¢ã®åãä»ã . . . . . . . . . . . . . . . 17 17 18 18 18 18 18 19 19 19 20 20 21 21 22 管çæ©èœ CIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ãã¹ ã ãã¹ ã¢ã ã 㿠㌠API . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 24 ã· ã¹ ãã èŠä»¶ . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx Linux ã ã© ã€ãã®ã¢ ã³ ã㌠ã ãŸãã¯åé€ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPM 〠㳠㹠ã ãŒã«ã ãã® ã ã© ã€ãã®ã¢ ã³ ã㌠ã ãŸãã¯åé€ . . . . . . . . . . . . TAR 〠㳠㹠ã ãŒã«ãã ã® ã ã© ã€ãã®åé€. . . . . . . . . . . . . . . . . . . . . . . . . . . . . RPM ã ã ã±ãŒãž ãäœ¿çš ã ã QCS ã®ã¢ 㳠〠㳠㹠ã ãŒã« . . . . . . . . . . . . . . . . PCI ã ã¡ ã€ã«ãã ã ããã ( ãªã 㷠㧠㳠) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx ã ã ã ã¯ãŒ ã¯ã«ãŒ ã ã¯ã㊠㳠ã ãŠãã ã ã ã ã¯ãŒ 㯠〠㳠㿠ã 㧠ãŒã¹ã«å² ã åœãŠ ã ããŠããŸã. . . . . . . . . . . . . . . . . . . . . . . . . . . . SCSI-ML ãéå§ ã ããã¹ ã 㮠㪠㻠ã ã ïŒã» ã 㷠㧠㳠㪠ã«ã ãª ïŒ . . . C-NIC ã iSCSI ã ã ã ã³ ã«éåãæ€åº ã 㟠ã ã - èŽåœç㚠㩠㌠. . C-NIC ã iSCSI ã ã ã ã³ ã«éåãæ€åº ã 㟠ã ã â èŽåœçã§ã¯ 㪠ã ã èŠåã§ã . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ã ã© ã€ãã¯ã ã» ã 㷠㧠㳠ã 㪠ã«ã 㪠ã ããŸã . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 8 VMware ãã©ã€ããœãããŠã§ã¢ .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 10 iSCSI ãããã³ã« . . . . . . . . . . . . . 82 82 83 83 84 88 88 93 94 94 96 97 97 109 109 109 109 109 110 111 113 113 113 114 114 114 .... .... .... 114 122 122 . . . . . . . . . . . . . 127 128 129 130 131 131 136 137 137 138 138 138 138 iSCSI ã㌠ã . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iSCSI ã㌠ã åãã«ãµã㌠ã ã ããŠã ã ãªã ã¬ãŒã 㣠㳠㰠㷠㹠ãã . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx ãµã㌠ã ã ããæ©èœ ïŒããŒã 㿠〠ãå¥ïŒ . . . . . . . . . . . . . . . . . . . . . ããŒã 㿠〠ãã®éžæ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ããŒã åã®ä»çµã¿ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ã¢ãŒãã 㯠ã 㣠. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ã ã㌠. . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx . . . . . . . . . 174 175 176 177 180 180 181 185 189 æŠèŠ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIC ããŒã 㣠㷠㧠ã³ååãã«ãµã㌠ã ã ããŠãã ãªã 㬠ãŒã 㣠㳠㰠㷠㹠ãã . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIC ããŒã 㣠㷠㧠ã³åãæ§æãã . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 14 ãã¡ã€ããŒãã£ãã«ãªãŒããŒã€ãŒãµããã æŠèŠ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SAN ã ã ã® FCoE ã㌠ã . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCoE ã®æ§ç¯ ãš ã㌠ã çšã«ã· ã¹ ãã BIOS ãæºåãã . . . . . . . . . . . . . . . . . ã· ã¹ ãã ã®ã㌠ã é åºã®å€æŽ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 17 ä»æ§ 10/100/1000BASE-T ããã³ 10GBASE-T ã±ãŒãã«ã®ä»æ§ . . . . . . . . . . . . . . . . . NIC ãã ã ã®ãµã㌠ã 察象 SFP+ 㢠㞠㥠ãŒã« . . . . . . . . . . . . . . . . . . . . . . . . 〠㳠㿠ã 㧠ãŒã¹ä»æ§ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIC ã®ç©çç¹æ§ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NIC ã®é»åèŠä»¶ . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 19 ãã©ãã«ã·ã¥ãŒãã£ã³ã° ã㌠ã ㊠㧠ã¢ã®èšºæ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QCS 蚺æã ã¹ ã ã®å€±æ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QCS ã ã ã ã¯ãŒ 㯠ã ã¹ ã ã®å€±æ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ã㌠ã ã® LED ã®ç¢ºèª . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx å³ã®ãªã¹ã å³ 3-1 6-1 6-2 6-3 6-4 6-5 8-1 8-2 9-1 9-2 10-1 10-2 10-3 10-4 10-5 10-6 10-7 10-8 10-9 10-10 10-11 10-12 10-13 10-14 11-1 11-2 11-3 11-4 11-5 11-6 11-7 11-8 11-9 11-10 14-1 14-2 14-3 14-4 14-5 14-6 14-7 14-8 ããŒãž ã¿ ã°ä»ã ã ããè€æ°ã® VLAN ããµã㌠ã ãããµãŒããŒã®äŸ . . . . . . . . . . . . . . . . . . . . . . . . . CCM MBA èšå® ã¡ ã 㥠ãŒ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 14-9 FCoE Boot Configuration ïŒFCoE ã㌠ã èšå®ïŒ ã¡ ã 㥠ãŒã FCoE General Parameters ïŒFCoE äžè¬ã ã© ã¡ ãŒ ã¿ ïŒ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-10 FCoE ã㌠ã . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-11 EVBD ã ã© ã€ãã®ã€ ã³ ã¹ ã ãŒã« . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx è¡šã®ãªã¹ã è¡š 1-1 1-2 2-1 3-1 4-1 4-2 7-1 8-1 9-1 10-1 10-2 10-3 10-4 10-5 11-1 11-2 11-3 11-4 11-5 11-6 11-7 11-8 11-9 11-10 12-1 12-2 13-1 13-2 13-3 14-1 17-1 17-3 17-2 17-4 17-5 17-6 17-7 17-8 17-9 17-10 17-11 17-12 17-13 17-14 17-15 17-16 ããŒãž RJ45 ã㌠ã LED ã瀺ãã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠ã®ç¶æ
. . . . . . . . . . . . . . . ã㌠ã LED ã瀺ãã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠. . . . . . . . . . . . . . . . . . . . . . . . .
ãŠãŒã¶ãŒãºã¬ 〠ã â 〠ãŒãµã ã ã iSCSI ã¢ãã ã¿ ãã㳠〠ãŒãµã ã ã FCoE ã¢ãã ã¿ QLogic BCM57xx ããã³ BCM57xxx 18-1 QLogic 57800S 1GB ããã³ 10GBASE-T ã© ã 㯠ã ã ã ã¯ãŒ 㯠ã ㌠㿠㌠㫠㌠ã ã® 18-2 QLogic 57800S 㯠㢠ã ã RJ-45ã SFP+ã 㟠ãã¯çŽæ¥æ¥ç¶ ã© ã 㯠ã ã ã ã¯ãŒ 㯠18-3 18-4 18-5 18-6 18-7 QLogic 57810S ã 㥠ã¢ã« 10GBASE-T PCI-e 㫠㌠ã ã®ç©ççç¹æ§ . . . . . . . . . . . . . . . . . QLogic 57810S ã 㥠ã¢ã« SFP+ ãŸãã¯çŽæ¥æ¥ç¶ PCIe ã®ç©ççç¹æ§. . . . . . . . . . . . . . . . QLogic 57810S-K ã 㥠ã¢ã« KR ã 㬠㌠ã ã¡ ã¶ã ã³ ã¢ã ã ã¿ ãŒã®ç©ççç¹æ§ . . . . . . . . . .
ã¯ããã« æ¬é
ã§ã¯ã æ¬æžã®å¯Ÿè±¡èªè
ã å
容ã ã ã 㥠㡠㳠ã ã®è¡šç€ºèŠåã ã ãã³ã¬ ãŒã¶ãŒã®å®å
šæ§ ã«ã€ããŠã®æ
å ±ã瀺 ã ãŸãã ã¡ã¢ QLogic® ã¯ã ãã¹ãŠã® QLogic ã¢ã ã ã¿ ãŒã«å¯Ÿããå¯äžã® GUI 管çããŒã« ãš ã ãŠã QConvergeConsole® ïŒQCCïŒ GUI ããµã㌠ã ãã ã ã ã«ãª ã 㟠ã ãã QLogic Control Suite ïŒQCSïŒ GUI ã¯ã 57xx/57xxx ã³ ã³ ã ã㌠㩠ã«åºã¥ãã QLogic ã¢ã ã ã¿ ãŒã§ã¯ãµã㌠ã ã ã㪠ã 㪠ã ã QCC GUI 管çããŒã«ã«çœ®ãæã ã 㟠ã ãã QCC GUI ã§ã¯ã ãã¹ãŠã® QLogic ã¢ã ã ã¿ ãŒã«ã åäžç»é¢ã® GUI 管 çãæäŸ ã ãŸãã Windows® ç°å¢ã§ã¯ã QCS CLI ãš Management Agents Installer ãå®è¡ãã ãš ã QCS GUI ïŒã· ã¹ ãã 㫠〠㳠㹠ã ãŒã« ã ããŠããå ŽåïŒ ãš ãã¹ãŠã®é¢é£ ã³ ã³ ããŒã ã³ ã ãã· ã¹ ãã ã ã 㢠㳠〠ã³
㯠ã ãã« é¢é£è³æ é¢é£è³æ 詳现ã«ã€ããŠã¯ã ãMigration Guide: QLogic/Broadcom NetXtreme I/II Adaptersã ïŒã 〠㰠ã¬ãŒã· 㧠㳠㬠〠ã ïŒ QLogic/Broadcom NetXtreme I/II ã¢ã ã ã¿ ãŒïŒã ææžçªå· BC0054606-00 ãåç
§ ã ㊠ã ã ã ãã ã 〠㰠㬠ãŒã· 㧠㳠㬠〠ã ã«ã¯ã QLogic ã« ã ãç¹ å®ã® Broadcom® 〠ãŒãµã ã ã è³ç£ã®è²·åã«é¢ããæŠèŠã ã ãã³ãã®ãš ã³ ã ãŠãŒã¶ãŒãž ã®åœ±é¿ã説æ ã ããŠã ã ã Broadcom ãš QLogic å
±åã§äœæ ã ã㟠ã ãã ããã¥ã¡ã³ãã®è¡šç€ºèŠå æ¬ã¬ 〠ã ã§ã¯æ¬¡ã®è¡šèšäžã®èŠåãäœ¿çš ã ãŸãã ï® ã¡ã¢ ï® æ³šæ ï® ï® è¿œå æ
å ±ãæäŸ ã ãŸãã èŠåèšå·ãä»ããŠããªãå Žåã è£
眮ãžã®æå·ã ãŸãã¯ã㌠㿠㮠åªå€±ã®åå 㚠㪠ãå¯èœæ§ãã ãå±éºã®ååšã瀺 ã ãŸãã ! 泚æ ! èŠå èŠåèšå·ãä»ããŠã ãå Žåã 軜床ãŸãã¯äžåºŠã®æªæã®åå
㯠ã ãã« ã ã 㥠㡠㳠ã ã®ããŠã³ ã㌠ã ï® ï® ï® ããŒå ãš ããŒã¹ ã ã㌠ã¯ã¯å€§æåã§è¡šèš ã ããŸãã ï± CTRL+P ããŒãæŒ ã ãŸãã ï± äžç¢å° ããŒãæŒ ã ãŸãã æäœã®ããã¹ ã ã¯ã çšèªã 匷調ã å€æ°ã ãŸãã¯ææžã® 㿠〠ã ã«ã瀺 ã ãŸãã äŸ ïŒ ï± äœ¿çšèš±è«Ÿå¥çŽæžã®å®å
šãª 㪠㹠ã ã«ã€ããŠã¯ã QLogic 㜠ã ã ㊠㧠㢠㚠㳠ã ãŠãŒã¶ãŒäœ¿çšèš±è«Ÿå¥çŽæžãåç
§ ã ㊠ã ã ã ãã ï± ã· ã§ ãŒ ã ã« ã ã ã㌠㚠㯠? ï± æ¥ä»ãå
¥åãã ã«ã¯ã mm/dd/yyyy ãå
¥å ã ãŸã ïŒ ã ã ã§ã mm ã¯æã dd ã¯æ¥ã yyyy ã¯å¹Žã§ãïŒã åŒçšç¬Šã§å²ãŸãã ã ã ã 㯠㿠〠ã ã«ã¯ã æ¬ãã 㥠ã¢ã«ãŸãã¯ãª 㳠㩠〠㳠ãã«ã ïŒæ¬æžã§ã¯ ãã«ã ã· ã¹ ãã ãš ã åŒã°ããŠããŸãïŒ ã®ããããã«ã ãé¢é£ ã ã ã 㯠ãæ ã ãŠããŸãã ããã¥ã¡ã³ãã®ããŠã³ããŒã æ¬æžã§åç
§ããã QLogic ããã¥ã¡ã³ããããŠã³ããŒãããã«ã¯ã次ã®æé ãå®è¡ã
㯠ã ãã« ã¬ãŒã¶ãŒã®å®å
šæ§ã«ã€ããŠã®æ
å ± ã¬ãŒã¶ãŒã®å®å
šæ§ã«ã€ããŠã®æ
å ± ã ã®è£œåã¯ã å
ã ã¡ ã€ãç·ã« ã ãéä¿¡ã®ããã«ã 㯠㩠㹠1 ã®ã¬ ãŒã¶ãŒå
ã ã© ã³ ã·ãŒãã 䜿çšãã ã ãš ãã ã ãŸãã DHHS ïŒç±³åœä¿éºç€ŸäŒçŠç¥çïŒ ã§ã¯ã 㯠㩠㹠1 ã®ã¬ãŒã¶ãŒã¯ æ害 ãš ã¯èŠãª ã ããŠããŸããã IEC ïŒInternational Electrotechnical Commission ïŒ åœ éé»æ°æšæºäŒè°ïŒ 825 㬠ãŒã¶ãŒå®å
šåºæºã§ã¯ã 補åã 㯠㩠㹠1 ã®ã¬ãŒã¶ãŒãäœ¿çš ã ãŠã ã ã ãš ãè±èªã ã 〠ãèªã ã 㣠㳠㩠㳠ã èªã ããã³ ã ã© ã³ ã¹èªã§èšèŒ ã ã ã© ãã«ãä»ã ã ã ãš ã矩åä»ã ãããŠããŸãã ã ã© ã³ ã·ãŒãã« ã© ãã«ãä»ãã ã ãš ã¯ã§ ã ãªãã®ã§ã 次ã®ã© ãã«ãæ¬ãã 㥠ã¢ã«ã«ãŠæäŸ ã ããŠããŸãã xxii BC0054508-04 J
1 æ©èœãšç¹åŸŽ æ¬ç« ã§ã¯ã ã¢ã ã ã¿ ãŒã«é¢ãã次ã®æ
å ±ã«ã€ããŠèª¬æ ã ãŸãã ï® æ©èœã®èª¬æ ï® 2 ããŒãžã® ãæ©èœã ï® 6 ããŒãžã® ããµã㌠ã ã ãã ãªã 㬠ãŒã 㣠㳠ã°ç°å¢ã ï® 6 ããŒãžã® ãã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠ã®ç¶æ
ã®éç¥ã æ©èœã®èª¬æ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã¯ã æ° ã ã 㯠㩠ã¹ã®ã®ã¬ ã ã ã 〠㌠ãµã ã ã ïŒGbEïŒ ããã³ 10GbE çµ±åã ã ã ã¯ãŒ 㯠〠㳠㿠ã 㧠ãŒã¹ ã³ ã³ ã ã㌠㩠ïŒC-NICïŒ ã§ã ã ã æšæºç㪠〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ã§ã é«éå ã ããã㌠㿠ã ã ã ã¯ãŒ 㯠ã ã¹ ã 㬠ãŒãžã ã ã ã¯ãŒ 㯠ãåæã«å®è¡ã§ ã ãŸãã C-NIC ã¯ã 以äžã®ã ã ãªã㌠㿠㻠㳠㿠ãŒã§äœ¿çš ã ããäžè¬ç㪠ã ã ã ã³ ã«ã§é«éåãå®çŸ ã ãŸãã ï® 1GbEã 10GbE ã察象 ãš ã ㊠TCP ãé«éåãã TCP Offload En
1â æ©èœ ãš ç¹åŸŽ æ©èœ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã«ã¯ã åäºéæ¹åŒæ©èœ ãš å
šäºéæ¹åŒ æ©èœã®äž¡æ¹ãåãã 10Mbpsã 100Mbpsã 1000Mbpsã 10Gbps 〠ãŒãµã ã ã MAC ã®ã»ãã 10Mbpsã 100Mbpsã 1000Mbpsã 10Gbps ç©ç㬠ã€ã€ ïŒPHYïŒ ãå«ãŸã㟠ãã ã ã© ã³ ã·ãŒãã¯ã é床ã®èªåã㎠㷠ãšãŒã· 㧠㳠ã«é¢ ã ㊠IEEE 802.
1â æ©èœ ãš ç¹åŸŽ æ©èœ ï® ãã®ä»ã®ã ã ã© ãŒã ã³ ã¹æ©èœ ïŒ ï± ï± ï± ï± ï® ï® TCPã IPã UDP ã 㧠ã 㯠ãµã TCP ã»ã° ã¡ ã³ ããŒã· 㧠㳠é©å¿å² ã 蟌㿠ïŒ5 ããŒãžã® ãé©å¿å²èŸŒã¿é »åºŠã ãåç
§ïŒ åä¿¡åŽã¹ã±ãŒ 㪠㳠㰠ïŒRSSïŒ ç®¡çæ©èœ ïŒ ï± QLogic Control Suite ïŒQCSïŒ èšºæã ãã³èšå®ãœ ã ã ㊠㧠㢠㹠〠㌠ã ïŒ5 ããŒãžã® ãQLogic Control Suite CLIã ãåç
§ïŒ ï± PXE 2.0 ä»æ§ããµã㌠ã ï± Wake on LAN ïŒWoLïŒ ã®ãµã㌠ã ï± Universal Management Port ïŒUMPïŒ ã®ãµã㌠ã ï± SMBus ã³ ã³ ã ããŒ ã© ï± Advanced Configuration and Power Interface ïŒACPIïŒ 1.
1â æ©èœ ãš ç¹åŸŽ æ©èœ ï® 128 ã ã ã ã ã ã· ã³ã°ã㌠ã ㊠㧠ã¢æ©èœã« ã ã ãã«ãã 㣠㹠ã 㢠ã 㬠ã¹ã®ãµã㌠ã ï® ã· ãª ã¢ã« ã ã© ã 㷠㥠NVRAM ã¡ ã¢ ãª ï® JTAG ã®ãµã㌠ã ï® PCI é»æºç®¡ç〠㳠㿠ã 㧠ãŒã¹ ïŒv1.
1â æ©èœ ãš ç¹åŸŽ æ©èœ ï® ã¬ ã·ãŒã CRC 㪠ã ã㌠ã ï® ã ã© ã³ ã¹ ã ã ã¿ CRC 㪠ã ã㌠ã ï® ã ã¡ ã€ã ã 㣠ãã« ã ã© ã 㣠ã ã¯çšã«èšå® ã ããå°çšã®ã ã¥ ãŒ ï® åªå
床 ã ããŒå¶åŸ¡ ïŒPFCïŒ ãš ãš ã ã« ã 㹠㬠ã¹åäœãæäŸããã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ ã° ïŒDCBïŒ ï® æ¡åŒµäŒééžæ ïŒETSïŒ ãš ãš ã ã« FCoE ã ã© ã 㣠ã 㯠㫠㪠㳠㯠垯åå¹
ãå² ã åœãŠ ã DCB ï® æè¡å§å¡äŒ T11 Fiber Channel - Link Service ã¹ ïŒFC-LSïŒ ä»æ§ã Linux ããã³ Windows äžã® N_Port ID Virtualization ïŒNPIVïŒ ããµã㌠ã ã ãŸãã é»æºã®ç®¡ç ã· ã¹ ãã ã®é»æºãåããŠãã ãš ãã¯ã WoL ã«å¯Ÿ ã ãŠèšå® ã ããé床ã§ã ã¢ã ã ã¿ ãŒã®é 床èšå®ã® 㪠㳠㯠ãè¡ãããŸãã ã¡ã¢ Dell⢠ã§ã¯ã äžåºŠã« 1 çš®é¡ã®ã¢ã ã ã¿ ãŒäžã§ ã ã WoL ããµã㌠ã ã ãŸã
1â æ©èœ ãš ç¹åŸŽ ãµã㌠ã ã ãã ãªã ã¬ãŒã 㣠ã³ã°ç°å¢ ãµããŒãããããªãã¬ãŒãã£ã³ã°ç°å¢ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã¯ã 次ã®ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã«å¯Ÿãã 㜠ã ã ㊠㧠ã¢ãµã㌠ã ãåã ãŠããŸãã ï® Microsoft Windows ïŒ32 ã ã ã ã ãã³ 64 ã ã ã æ¡åŒµïŒ ï® Linux ïŒ64 ã ã ã æ¡åŒµïŒ ï® ESXi⢠Server ïŒVMwareïŒ ï® Citrix® XenServer ãããã¯ãŒã¯ãªã³ã¯ãšã¢ã¯ãã£ããã£ã®ç¶æ
ã®éç¥ é
ç·ã€ ãŒãµã ã ã æ¥ç¶ã®å Žåã ã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠ã®ç¶æ
ã¯ã è¡š 1-1 ã«ç€ºãã ã ã«ã RJ45 ã³ ã 㯠㿠ã«ã ã LED ã®ç¶æ
ã§ç€º ã ããŸãã è¡š 1-1.
2 Windows Server ã§ã® ããŒã åã®èšå® Microsoft Windows Server® ã· ã¹ ãã ã®ããŒã åèšå®ã«ã¯ã QLogic Advanced Server Program ïŒQLASPïŒ ã®æŠèŠã è² è·åæ£ã ã ã© ãŒã« ã ã 㬠㩠㳠ã¹ãå«ãŸããŸãã Windows Server 2016 以éã¯ã QLogic ã® QLASP ããŒã å ã ã© ã€ãããµã㌠ã ã ãŠããŸããã ï® QLASP ã®æŠèŠ ï® 8 ããŒãžã® ãè² è·ã ã© ã³ ã· ã³ ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠ã¹ã ã¡ã¢ ã ã®ç« ã§ã¯ã Windows Server ã· ã¹ ãã ã§ã®è€æ°ã®ã¢ã ã ã¿ ã®ããŒã åã«ã€ã㊠説æ ã ãŸãã Linux ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã§ã®é¡äŒŒã®æè¡ ïŒãã 㣠ãã«çµåã ãš åŒã³ãŸãïŒ ã®è©³çŽ°ã¯ã 該åœãã ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã ã®ãã 㥠ã¢ã«ãåç
§ ã ㊠ã ã ã ãã QLASP ã®æŠèŠ QLASP ã¯ã Windows 㷠㪠ãŒãºã®ãªã ã¬ãŒã 㣠ã³ã°ã· ã¹ ãã åãã® QLogic ããŒã
2âWindows Server ã§ã®ããŒã åã®èšå® è² è·ãã© ã³ ã· ã³ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠ã¡ã¢ Windows Server 2012 ã«ã¯ NIC ã㌠ã ã³ ã° ãš ã ã ãã« ã 〠㳠ã㌠ã ã³ ã°ãµã㌠ã ãã ã ãŸãã å ã ã¢ã ã ã¿ ãŒã«å¯Ÿ ã ãŠã ãŠãŒã¶ãŒã NIC ã㌠ã ã³ ã° ãš QLASP ãåæã«äœ¿çš ã ãŠããŒã åãæå¹ã«ãã ã ãš ã¯ãå§ã㧠ã ãŸããã Windows Server 2016 ã¯ã QLogic ã® QLASP ããŒã å ã ã© ã€ãããµã㌠ã ã ãŠããŸããã è² è·ãã©ã³ã·ã³ã°ãšãã©ãŒã«ããã¬ã©ã³ã¹ ããŒã åãè¡ ã ã ãš ã§ã ã ã© ã 㣠ã ã¯ã®è² è·ã ã© ã³ ã· ã³ ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠ïŒã ã ã ã¯ãŒ ã¯æ¥ç¶ã«å€±æ ã ãå Žåã«ã ã¢ã ã ã¿ ãŒã®åäœãåé·åãã ã ãš ïŒ ãå®çŸã§ ã ãŸãã 1 å°ã®ã· ã¹ ãã ã«è€æ°ã®ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒãå ã ä»ã ã ããŠãã ãš ãã¯ã ä»®æ³ã¢ã ã
2âWindows Server ã§ã®ããŒã åã®èšå® è² è·ãã© ã³ ã· ã³ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠Smart Load Balancing ããã³ãã§ã€ã«ãªãŒã㌠Smart Load Balancing ããã³ ã 㧠ã€ã«ãªãŒããŒã¯ã IP ã ããŒã«åºã¥ ã è² è·ã ã© ã³ ã· ã³ ã° ã Broadcom® ã§å®çŸ ã ãŸãã ã ã®æ©èœã¯ã åæ¹åã§è€æ°ã®ã¢ã ã ã¿ ( ããŒã ã¡ ã³ ã㌠) ã« ã ã IP ã ã© ã 㣠ã 㯠ã®ã ã© ã³ ã· ã³ ã° ããµã㌠ã ã ãŸãã ã ã®ããŒã 㿠〠ã 㧠ã¯ã ããŒã å
ã®ãã¹ãŠã®ã¢ã ã ã¿ ã¯ã åå¥ã® MAC 㢠ã 㬠㹠ãæ 㣠ãŠããŸãã ã ã®ã㌠ã 㿠〠ã ã§ã¯ã èªåæ
éæ€åº ãš ã å¥ã®ããŒã ã¡ ã³ããŒãŸãã¯ã ã ã ã¹ ã¿ ã³ã〠㡠ã³ã㌠ãžã®åç ã 㧠ã€ã«ãªãŒããŒãè¡ãããŸãã ã 㧠ã€ã«ãªãŒããŒã¯ã 㬠ã€ã€ 3 ã ã ã ã³ ã« ïŒIPã IPXã ã ãã³ NetBIOS Extended User Interface [NetBEUI]ïŒ ã ã ç¬ç« ã
2âWindows Server ã§ã®ããŒã åã®èšå® è² è·ãã© ã³ ã· ã³ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠éæäžç¶ïŒFEC/GECïŒ/802.3ad-Draft Static éæäžç¶ (FEC/GEC)/802.3ad-Draft Static ããŒã 㿠〠ãã¯ã å ã MAC 㢠ã 㬠ã¹ã«å¯Ÿ ãããã± ã ã ãåä¿¡ãã ã ã ã«èšå®ããç¹ã§ã 㪠㳠ã¯éçŽ (802.3ad) ããŒã 㿠〠ã ãš é åžžã«äŒŒãŠããŸãã ãã ã ã éæäžç¶ (FEC/GEC)/802.
2âWindows Server ã§ã®ããŒã åã®èšå® è² è·ãã© ã³ ã· ã³ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠Smart Load Balancing ããã³ãã¡ã€ã«ãªãŒã㌠/SLBïŒèªå ãã©ãŒã«ããã¯ã¯ç¡å¹ïŒããŒã ã¿ã€ãã®å¶éäºé
Smart Load Balancing ïŒSLBïŒ ã¯ã ã ã ã ã³ ã«åºæã®ã¹ããŒã ã§ãã IP ã®ãµã㌠ã 㬠ãã«ã è¡š 2-1 㫠㪠㹠ã ã ãŸãã è¡š 2-1.
2âWindows Server ã§ã®ããŒã åã®èšå® è² è·ãã© ã³ ã· ã³ã° ãš ã ã© ãŒã« ã ã 㬠㩠㳠㹠ããŒã åããã³å€§ééä¿¡ãªãããŒããšãã§ãã¯ãµã ãªãããŒãã® ãµããŒã Large Send Offload ïŒLSOã 倧éé信㪠ã ã㌠ã ïŒ ãš Checksum Offload ïŒã 㧠ã 㯠ãµã 㪠ã ã㌠ã ïŒ ã¯ã ãã¹ãŠã® ã¡ ã³ããŒãæ©èœããµã㌠ã ã ã ãã®æ©èœçšã«èšå® ã ã㊠ã ãå Žåã«ã®ã¿ã ããŒã ã«å¯Ÿ ã ãŠæå¹ã« ã ããŸãã 12 BC0054508-04 J
3 Windows ã§ã®ä»®æ³ LAN æ¬ç« ã§ã¯ã ããŒã åãè¡ ã ããã® Windows ã§ã® VLAN ã«ä»ããŠã®æ
å ±ãæäŸ ã ãŸãã ï® VLAN ã®æŠèŠ ï® 16 ããŒãžã® ãããŒã ãžã® VLAN ã®è¿œå ã VLAN ã®æŠèŠ VLAN ïŒä»®æ³ LANïŒ ãå©çšãã ãš ã ç©ç LAN ãçè«çãªããŒã ã«åå² ã ã ã¯ãŒ 㯠㰠ã«ãŒãã®è«ççãªã»ã° ã¡ ã³ ã ãäœæ㧠ã ãŸãã ã ãã« ã ã åè«çã»ã° ã¡ ã³ ã ã ãš ã«ã» ã 㥠㪠ã 㣠ã 㪠ã·ãŒãèšå®ãã ã ãš ãå¯èœã«ãª ã ãŸãã å®çŸ©æžã¿ã® VLAN ã¯ã ãã® ã ã© ã 㣠ã 㯠ãåå ±éä¿¡ããã®ä»ã® VLAN ã ã åé¢ ã ãã ããã ãããããç¬èªã®åé¢ ã ã ãã ã ã ã¯ãŒ 㯠㚠ã ãŠæ©èœ ã ãŸãã ã ãã« ã ã åè«çã°ã«ãŒãå
ã®åž¯åå¹
ã®å¹çãåäž ã ãŸãã ãµãŒããŒäžã® 1 ã€ã® QLogic ã¢ã ã ã¿ ãŒã«ã¯æ倧 64 å ïŒ ã¿ ã°ä»ã ã ãã ã ã® 63 件ã ã¿ ã°ä»ã ã ããŠããªã ãã® 1 ä»¶ïŒ ãŸ ã§ã® VLAN ãå®çŸ©ã§ ã ãŸãã å®
3âWindows ã§ã®ä»®æ³ LAN VLAN ã®æŠèŠ å³ 3-1. ã¿ã°ä»ããããè€æ°ã® VLAN ããµããŒããããµãŒããŒã®äŸ å³ 3-1 ã¯ã VLAN ã䜿çšãã ã ã ã ã¯ãŒ 㯠ã®äŸã瀺 ã ãŠããŸãã ã ã®ã ã ã ã¯ãŒ ã¯äŸã§ ã¯ã ç©ç LAN 㯠1 ã€ã®ã¹ 〠ã ãã 2 ã€ã®ãµãŒããŒã 5 件㮠㯠㩠〠㢠㳠ã ã§æ§æ ã ã㊠ããŸãã LAN ã¯è«ççã« 3 ã€ã®ç°ãª ã VLAN ã«çµç¹å ã ããŸãã VLAN ã¯ããããç° ãª ã IP ãµãã ã ã ã代衚 ã ãŸãã è¡š 3-1 ã¯ã ã ã®ã ã ã ã¯ãŒ 㯠ã®æ©èœã瀺 ã ãŠããŸãã è¡š 3-1.
3âWindows ã§ã®ä»®æ³ LAN VLAN ã®æŠèŠ è¡š 3-1.
3âWindows ã§ã®ä»®æ³ LAN ããŒã ãžã® VLAN ã®è¿œå ããŒã ãžã® VLAN ã®è¿œå 1 ã€ã®ããŒã ãã ã ã 64 åã® VLAN ããµã㌠ã 㧠ã ãŸã ïŒ ã¿ ã°ä»ã ã ãã ã ã® 63 件ã ã¿ ã°ä»ã ã ããŠããªã ãã® 1 件ïŒã VLAN ã®ããŒã ãæ§æ㧠ã ãã®ã¯ã QLogic ã¢ã ã 㿠㌠㚠Alteon® AceNIC ã¢ã ã ã¿ ãŒã®ã¿ã§ãã 1 ã€ã®ã¢ã ã ã¿ äžã«è€æ°ã® VLAN ãã ãå Žåã ã¢ã ã ã¿ ã 1 〠ã ããªããµãŒããŒã§ã¯ã è€æ°ã® IP ãµãã ã ã äžã« 1 ã€ã®è«ç ã ã¬ãŒã³ ã¹ ã ãäžã ã ããŸããã 1 ã€ã®ããŒã ã«è€æ°ã® VLAN ãã ãå Žåã¯ã è€æ°ã® IP ãµãã ã ã ã« 1 ã€ã®è«çã ã¬ãŒã³ ã¹ ãäžãã ã㌠ã ã ã© ã³ ã· ã³ ã° ãš ã 㧠ã€ã«ãªãŒã㌠㫠ã ãå©ç¹ãçãã ã ãš ã㧠ã ãŸãã ã¡ã¢ ã 㧠ã€ã«ãªãŒããŒããŒã ã® ã¡ ã³ããŒã§ã ã ã¢ã ã ã¿ ãŒãã VLAN ããµã㌠ã ãã ã ã ã«èšå®ã§ ã ãŸãã Intel LOM ã ã 㧠ã€ã«ãª
4 ããŒããŠã§ã¢ã®åãä»ã æ¬ç« ã¯ã QLogic BCM57xx ããã³ BCM57xxx 㢠ã 〠㳠ã ã ã ã¯ãŒ 㯠〠㳠㿠ã 㧠ãŒã¹ 㫠㌠ã ã«é©çš ã ããŸãã ã㌠ã ㊠㧠ã¢ã®å ã ä»ãã«ã¯ä»¥äžãå«ãŸããŸãã ï® ã· ã¹ ãã èŠä»¶ ï® 19 ããŒãžã® ãå®å
šäžã®æ³šæã ï® 19 ããŒãžã® ãå ã ä»ãäºåã 㧠ã 㯠㪠㹠ã ã ï® 20 ããŒãžã® ã㢠ã 〠㳠NIC ã®å ã ä»ãã ã¡ã¢ ãµãŒãã¹æ
åœè
ïŒ ã ã®è£œåã¯ã 㢠㯠ã»ã¹å¶éé å (RAL ïŒ Restricted Access Location) ã§ã®ã€ ã³ ã¹ ã ãŒã«ã«ã®ã¿å¯Ÿå¿ ã ãŠããŸãã ã·ã¹ãã èŠä»¶ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã®å ã ä»ã ãéå§ããåã«ã æ¬é
㧠説æ ã ããŠããã㌠ã ㊠㧠ã¢ã ãã³ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã®èŠä»¶ãã· ã¹ ãã ã§æºã ã ããŠã ã ã ãš ãç¢ºèª ã ㊠ã ã ã ãã ããŒããŠã§ã¢èŠä»¶ ï® ãªã ã¬ãŒã 㣠㳠㰠㷠㹠ãã èŠä»¶ãæºãã
4â ã㌠ã ㊠㧠ã¢ã®å ã ä»ã ã·ã¹ ãã èŠä»¶ ãªãã¬ãŒãã£ã³ã°ã·ã¹ãã èŠä»¶ ã¡ã¢ ãDell Update Packages Version xx.xx.xxx Userâs Guideã ã¯ã 〠ãŒãµã ã ã 㢠ã ã ã¿ ãŒã®ãŠãŒã¶ãŒãºã¬ 〠ã ãš å ã ãµã€ 㯠ã«ã§æŽæ° ã ããŠããªãããã æ¬é
ã«èš èŒ ã ãããªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ãææ°ã® ãã® ãš ã¿ãª ã ㊠ã ã ã ãã æ¬é
ã¯ãµã㌠ã ã ããå OS ã®èŠä»¶ã説æ ã ãŸãã äžè¬ 以äžã®ãã¹ ã 〠㳠㿠ã 㧠ãŒã¹ãå¿
èŠã§ãã ï® PCI Express v1.
4â ã㌠ã ㊠㧠ã¢ã®å ã ä»ã å®å
šäžã®æ³šæ VMware ESXi 6.0 U3 VMware ESXi 6.0 U2 ï® ï® Citrix XenServer XenServer ã®ä»¥äžã®ããŒãž ã§ ã³ ïŒ Citrix XenServer 6.
4â ã㌠ã ㊠㧠ã¢ã®å ã ä»ã 㢠ã 〠㳠NIC ã®å ã ä»ã ã¢ãã€ã³ NIC ã®åãä»ã ã» ãš ãã©ã®ã· ã¹ ãã ã§ã¯ã QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã 㿠㌠ïŒã¢ ã 〠㳠NICïŒ ãå ã ä»ãã ãš ã ã«ã 以äžã®æé ã«åŸ 㣠㊠ã ã ã ãã ã䜿ãã®åå¥ã®ã· ã¹ ãã 㧠ã ã ã 㮠㿠㹠㯠ãå®è¡ãã ãš ãã®è©³çŽ°ã«ã€ããŠã¯ã ã· ã¹ ãã å梱ã®ãã 㥠ã¢ã«ãåç
§ ã ㊠ã ã ã ãã ã¢ãã€ã³ NIC ãã€ã³ã¹ããŒã«ãã 1. å®å
šäžã®æ³šæããã³å ã ä»ãäºåã 㧠ã 㯠㪠㹠ã ãèŠçŽ ã ãŸãã ã¢ã ã ã¿ ãŒãå ã ä»ããåã«ã ã· ã¹ ãã ã®é»æºãåããŠãã ã ãš ã é»æº 㳠㌠ã ã ã³ ã³ ã» ã³ ã ã ã æãããŠã ã ã ãš ã ããã³é©åãªé»æ°æ¥å°æé ã«åŸ 㣠ãŠã ã ã ãš ãç¢ºèª ã ãŸãã 2. ã· ã¹ ãã ã®ã±ãŒã¹ ãéãã PCIe® 1.0a x1ã PCIe 1.
4â ã㌠ã ㊠㧠ã¢ã®å ã ä»ã 㢠ã 〠㳠NIC ã®å ã ä»ã ãããã¯ãŒã¯ã±ãŒãã«ã®æ¥ç¶ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã«ã¯ã 〠ãŒãµã ã ã ã®é
ç·ã»ã° ã¡ ã³ ã ã«ã· ã¹ ãã ãæ¥ç¶ãã ããã® RJ45 ã³ ã 㯠㿠ãã ã ã ã ã 㫠〠ãŒãµã ã ã ã®å
ã 㡠〠ããŒã»ã° ã¡ ã³ ã ã«ã· ã¹ ãã ãæ¥ç¶ãã ããã®å
ã ã¡ ã€ã㌠㳠ã 㯠㿠ãã ã ãŸãã ã¡ã¢ ã ã®ã» 㯠㷠㧠ã³ã¯ã ã 㬠㌠ã ãµãŒããŒã«ã¯é©çš ã ããŸããã é
ç· å°ç·ãæ¥ç¶ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. é©åãªã±ãŒãã«ãéžæ ã ãŸãã è¡š 4-1 ã«ã¯ã 100 ã ãã³ 1000BASE-T ã㌠ã ã 10GBASE-T ã㌠ã ã«æ¥ç¶ããé
ç·ã±ãŒãã«ã®èŠä»¶ã 㟠㚠ããŠããŸãã è¡š 4-1.
4â ã㌠ã ㊠㧠ã¢ã®å ã ä»ã 㢠ã 〠㳠NIC ã®å ã ä»ã å
ãã¡ã€ã㌠å
ãã¡ã€ããŒã±ãŒãã«ãæ¥ç¶ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. é©åãªã±ãŒãã«ãéžæ ã ãŸãã è¡š 4-2 ã«ã 1000 ã ãã³ 2500BASE-X ã㌠ã ã« æ¥ç¶ããå
ã ã¡ ã€ããŒã±ãŒãã«ã®èŠä»¶ã 㟠㚠ããŸãã 263 ããŒãžã® ãNIC ãã ã ã®ãµã㌠ã 察象 SFP+ 㢠㞠㥠ãŒã«ã ã®è¡š ã åç
§ ã ㊠ã ã ã ãã è¡š 4-2. 1000/2500BASE-X å
ãã¡ã€ããŒä»æ§ ããŒãã¿ã€ã ã³ãã¯ã¿ 1000BASE-X 2500BASE-X a ã¡ãã£ã¢ LC⢠æ¥ç¶ã· ã¹ ãã ä»ã ã¹ã¢ãŒã«ã ã© ãŒã ã 㡠㯠㿠ïŒSFFïŒ ã ã© ã³ ã·ãŒã ãã«ãã¢ãŒ ã ã ã¡ ã€ã㌠ïŒMMFïŒ ïŒInfineon® éšåçªå· V23818-K305-L57ïŒ 62.
5 管çæ©èœ 管çæ©èœã«é¢ããæ
å ±ã«ã¯ã 以äžãå«ãŸããŸãã ï® CIM ï® 24 ããŒãžã® ããã¹ ã ãã¹ ã¢ã ã 㿠㌠APIã CIM CIM ïŒCommon Information ModelïŒ ã¯ã DMTF ïŒDistributed Management Task ForceïŒ ã« ã ã å®çŸ© ã ããŠããæ¥çæšæºã§ãã Microsoft ã¯ã Windows Sever ã ã© ã ã ã ã© ãŒã äžã« CIM ãå®è£
ã ãŠããŸãã QLogic ã§ã¯ã Windows Server ããã³ Linux ã ã© ã ã ã ã© ãŒã äžã§ CIM ããµã㌠ã ã ãŸãã ã¡ã¢ Linux ããŒã¹ ã· ã¹ ãã ã§ã® CIM ã ãã〠ãã®ã€ ã³ ã¹ ã ãŒã«ã®è©³çŽ°ã¯ã 第 13 ç« Linux QCS ã®ã€ ã³ ã¹ ã ãŒã«ãåç
§ ã ㊠ã ã ã ãã QLogic ã§ã¯ã CIM ãå®è£
ãã ã ãš ã« ã ã ã CIM 㯠㩠〠㢠㳠ã 㢠ã 㪠ã±ãŒã· 㧠㳠ãé ã ãŠãŠãŒã¶ãŒã«æ
å ±ã ã ã ã ã ã 㟠ã 㟠㪠㯠㩠㹠ãå®çŸ ã ãŠã
5â 管çæ©èœ ãã¹ ã ãã¹ ã¢ãã 㿠㌠API QLASP ã¯ã 〠ã ã³ ã ã ã° ãé ã ㊠〠ãã³ ã ãæäŸ ã ãŸãã ã ã ãã®ã€ ãã³ ã ãæ€æ»ãŸ ãã¯ç£èŠãã ã«ã¯ã Windows Server ã ã© ã ã ã ã© ãŒã ã§æäŸã®ã€ ã ã³ ã ã 㥠ãŒã¢ãŒãŸ ã㯠CIM ãäœ¿çš ã ãŸãã QLogic CIM ã®ã ãã〠ãã ã㯠CIM ã®æ±çšã€ ãã³ ã ã¢ãã« ãé ã ㊠〠ãã³ ã ã®æ
å ±ãæäŸ ã ããŸãã ã ã ã ã®ã€ ãã³ ã ã¯ã __InstanceCreationEventã __InstanceDeletionEventã ã ãã³ __InstanceModificationEvent ã§ã ã ã CIM ã« ã ã å®çŸ© ã ããŸãã CIM ã§ã¯ã 〠ã ã³ ã ãæ£ ã ã åä¿¡ãã ããã«ä»¥äžã®äŸã®ã ã 㪠㯠㚠㪠ãäœ¿çš ã ã 㯠㩠〠㢠㳠ã 㢠ã 㪠ã±ãŒã· 㧠ã³ã ã 〠ãã³ ã ã 㬠㞠㹠㿠ãã ãã㮠㯠㩠〠㢠㳠ã 㢠ã 㪠ã±ãŒã· 㧠ã³ãå¿
èŠ ã§ãã SE
6 Boot Agent ãã©ã€ããœãã ãŠã§ã¢ æ¬ç« ã§ã¯ã 㯠㩠〠㢠㳠ã ç°å¢ ãš ãµãŒããŒç°å¢ã®äž¡æ¹ã§ MBA ãèšå®ããæ¹æ³ã«ã€ããŠèª¬ æ ã ãŸãã ï® æŠèŠ ï® 26 ããŒãžã® ã 㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå®ã ï® 32 ããŒãžã® ãLinux ãµãŒããŒç°å¢ã§ã® MBA ã®èšå®ã æŠèŠ QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã¯ã Pre-eXecution Environment ïŒPXEïŒã Remote Program Load ïŒRPLïŒã iSCSIã ããã³ Bootstrap Protocol ïŒBOOTPïŒ ããµã㌠ã ã ãŠããŸãã QLogic ã® Multi-Boot Agent ïŒMBAïŒ ã¯ ãœ ã ã ㊠㧠㢠㢠㞠㥠ãŒã«ã§ã ã ããå©çšãã 㚠㪠ã¢ãŒ ã ãµãŒããŒã ã ã®ã€ ã¡ ãŒãž ã§ã ã ã ã¯ãŒ 㯠㳠㳠ã 㥠㌠㿠ãèµ·åãã ã ãš ã㧠ã ãŸãã QLogic MBA ã ã© ã€ã㯠PXE 2.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® ï® Windows Deployment Services ïŒWDSïŒ ïŒ Microsoft WDS ã§ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã ã㌠ã ãã ãš ã ã«ã åºæ¬çãªã ã ã ã¯ãŒ 㯠æ¥ç¶ä»¥äžã«æ©èœãæ¡åŒµã ã ã«ã¯ã EVBD ãŸãã¯ã ã ã ã¯ãŒ 㯠ã ã© ã€ã〠㳠㿠ã 㧠ãŒã¹ä»æ§ ïŒNDISïŒ ã 㩠〠ããäœ¿çš ã ㊠WinPE ïŒ3.0 以éïŒ ãçæ ã ãŸãã ã¯ã©ã€ã¢ã³ãç°å¢ã§ã® MBA ã®èšå® 㯠㩠〠㢠㳠ã ç°å¢ã§ MBA ã ã» ã ã 㢠ã ããã ã«ã¯ã 以äžã®æé ã«åŸããŸãã 1. MBA ã ã© ã€ãã®èšå®ãè¡ããŸãã 2.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® å³ 6-1. CCM MBA èšå®ã¡ãã¥ãŒ 3.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® UEFI ã®äœ¿çš UEFI ã䜿çšã㊠MBA ãã©ã€ããèšå®ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. ã· ã¹ ãã ãåèµ·å ã ãŸãã 2. Enter the ã· ã¹ ãã BIOS System Setup ïŒã» ã ã 㢠ã ããŠãŒã 㣠㪠ã ã£ ïŒ ã® Device Settings ïŒãã〠ã¹èšå®ïŒ èšå® ã¡ ã 㥠ãŒã«ç§»å ã ãŸã ïŒå³ 6-2 ãåç
§ïŒã å³ 6-2. System SetupïŒã»ããã¢ãããŠãŒãã£ãªãã£ïŒ ãDevice SettingsïŒããã€ã¹èšå®ïŒ 3.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® å³ 6-3. ããã€ã¹ã®èšå® 4.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® å³ 6-4. ã¡ã€ã³èšå®ããŒãž 5.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠㯠㩠〠㢠㳠ã ç°å¢ã§ã® MBA ã®èšå® å³ 6-5. NIC èšå® ã¡ã¢ iSCSI ã ãã³ FCoE ã㌠ã å¯Ÿå¿ LOM ã®å Žåã ã㌠ã ã ã ã ã³ ã«ã¯ BIOS ã ã èšå® ã ãŸãã 詳现ã«ã€ããŠã¯ã ã· ã¹ ãã ã®ææžé¡ãåç
§ ã ㊠ã ã ã ãã 6. äžåãç¢å°ã äžåãç¢å°ã å·Šåãç¢å°ã ããã³å³åãç¢å°ãäœ¿çš ã ãŠã å¿
èŠã«å¿ ã ãŠä»ã® ã¡ ã 㥠ãŒé
ç®ã«ç§»å ã ã ãã®å€ãå€æŽ ã ãŸãã 7. Back ïŒæ»ãïŒ ãéžæ ã ㊠Main ïŒ ã¡ ã€ ã³ïŒ ã¡ ã 㥠ãŒã«æ» ã ãŸãã 8.
6âBoot Agent ã ã© ã€ã 㜠ã ã ㊠㧠㢠Linux ãµãŒããŒç°å¢ã§ã® MBA ã®èšå® Linux ãµãŒããŒç°å¢ã§ã® MBA ã®èšå® Red Hat Enterprise Linux ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠ã³çã§ã¯ PXE ãµãŒããŒããµã㌠ã ã ããŠããŸãã ã ããå©çšãã ãš ã ã ã ã ã¯ãŒ ã¯äžã§ Linux ã®å®å
šã€ ã³ ã¹ ã ãŒã«ã 㪠ã¢ãŒ ã ãã å®è¡ã§ ã ãŸãã ã ã®ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠㳠ã«ã¯ã ã㌠ã ã« ãŒãã« (vmlinuz) ãš åæ RAM ã 㣠㹠㯠(initrd) ã®ã㌠ã 〠㡠ãŒãž ãæ·»ä» ã ããŠããŸãã ã ã ãã¯ã Red Hat disk#1 ã«ä¿å ã ããŠããŸãã /images/pxeboot/vmlinuz /images/pxeboot/initrd.
7 Linux ãã©ã€ããœãããŠã§ã¢ Linux ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã«é¢ããæ
å ±ã«ã¯ã 以äžãå«ãŸããŸãã ï® ã¯ ã ãã« ï® 34 ããŒãžã® ãå¶éã ï® 35 ããŒãžã® ãã ã ã±ãŒãž ã³ ã°ã ï® 36 ããŒãžã® ãLinux ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã«ã ï® 42 ããŒãžã® ãLinux ã ã© ã€ãã®ã¢ ã³ ã㌠ã ãŸãã¯åé€ã ï® 43 ããŒãžã® ãPCI ã ã¡ ã€ã«ãã ã ããã ( ãªã 㷠㧠㳠)ã ï® 44 ããŒãžã® ãã ã ã ã¯ãŒ 㯠〠㳠㹠ã ãŒã«ã ï® 44 ããŒãžã® ããªã 㷠㧠㳠ã ããã 㣠ã®ããã®å€ã®èšå®ã ï® 48 ããŒãžã® ã ã ã© ã€ãã®ã ã ã© ã« ã ã ï® 50 ããŒãžã® ã ã ã© ã€ã ã¡ ã ã»ãŒãžã ï® 56 ããŒãžã® ãã 㣠ãã«çµåã« ã ã ããŒã åã ï® 56 ããŒãžã® ãçµ±èšã ï® 56 ããŒãžã® ãLinux iSCSI 㪠ã ã㌠ã ã ã¯ããã« æ¬é
ã§ã¯ã è¡š 7-1 ã«ç€º ã ãã QLogic
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠å¶é è¡š 7-1.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã ã±ãŒãž ã³ã° bnx2fc ãã©ã€ãã®å¶é ã ã© ã€ãã®çŸè¡ããŒãž 㧠ã³ã¯ã RHEL 6.1 ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠㳠ã«å«ãŸããŠã ã 2.6.32 以éã® 2.6.x ã« ãŒãã«ã§ ã ã¹ ã ãå®æœ ã ã㟠ã ãã bnx2fc ã ã© ã€ãã¯ã 以åã® ã« ãŒãã«ã§ã¯ ã³ ã³ãã€ã«ã§ ã ãªã ã ãš ãã ã ãŸãã ã ã¹ ã ã¯ã i386 ãš x86_64 ã¢ãŒãã 㯠ã 㣠ã RHEL 6.1ã RHEL 7.0ã ã ãã³ SUSE 11 SP1 以éã®ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠㳠ã«å¶é ã ããŠã㟠ã ãã ããã±ãŒãžã³ã° Linux ã ã© ã€ãã¯ä»¥äžã® 2 çš®é¡ã®ã ã ã±ãŒãžåœ¢åŒã§é
åž ã ããŠããŸãã ãã€ãããã¯ã«ãŒãã«ã¢ãžã¥ãŒã«ãµããŒãïŒDKMSïŒããã±ãŒãž ï® netxtreme2-version.dkms.noarch.rpm ï® netxtreme2-version.dkms.src.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« Linux ã ã© ã€ãã«ã¯ã FCoE 〠㳠㿠㌠ã 㧠〠㹠ãå¶åŸ¡ãã ã ã ã³ ã ãš ã³ ã ãš ã ãŠã Open-FCoE userspace 管çããŒã«ã«å¯ŸããäŸåæ§ãã ã ãŸãã Open-FCoE ããŒã«ã® ã ã ã±ãŒãžåã¯ã RHEL 6.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« 3. æ°ãã« ã³ ã³ãã€ã« ã ã RPM ã 〠㳠㹠ã ãŒã« ã ãŸãã rpm -ivh RPMS//netxtreme2-..rpm 競åãå ±å ã ããŠããå Žåã äžéšã® Linux ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠㳠ã§ã¯ã --force ãªã 㷠㧠ã³ãå¿
èŠã«ãª ã ã ãš ãã ãã®ã§æ³šæ ã ㊠ã ã ã ãã 4. FCoE 㪠ã ã㌠ã ã«ã€ããŠã¯ã Open-FCoE ãŠãŒã 㣠㪠ã 㣠ã 〠㳠㹠ã ãŒã« ã 㟠ãã RHEL 6.4 ã ãã³ã¬ ã¬ã·ãŒããŒãž 㧠㳠ã«ã€ããŠã¯ã 次ã®ããããã® ã³ ã ã³ ã ã«ãª ã ãŸãã yum install fcoe-utils-.rhel.64.brcm...rpm rpm -ivh fcoe-utils-.rhel.64.brcm...
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« 9. ãã¹ãŠã® ethX 〠㳠㿠ã 㧠ãŒã¹ ã 㪠㳠㫠ã ãŸãã ifconfig up 10. SLES ã®å Žåã éç IP 㢠ã 㬠㹠ãèšå® ã ã ã ã 〠㳠㿠ã 㧠ãŒã¹ã§ DHCP ãæå¹ ã«ãã ã ãš ã« ã 㣠ãŠã ã㌠ã æã«èªåçã«èµ·å ã ãã ã ã ã«ã YaST ïŒopenSUSE ããã³ SUSE Linux Enterprise ã 㣠㹠ã 㪠ã 㥠ãŒã· 㧠ã³çšã®ã€ ã³ ã¹ ã ãŒã«ã ãã³èšå®ããŒã«ïŒ ãäœ¿çš ã ㊠〠ãŒãµã ã ã 〠㳠㿠ã 㧠ãŒã¹ ãèšå® ã 㟠ãã 11.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« KMP ããã±ãŒãžãã€ã³ã¹ããŒã«ãã ã¡ã¢ ã ã®æé ã®äŸã§ã¯ bnx2x ã ã© ã€ããå ã äžããŠããŸããã bxn2fc ããã³ bnx2i ã ã© ã€ãã« ãé©çš ã ããŸãã KMP ããã±ãŒãžãã€ã³ã¹ããŒã«ããã«ã¯ã次ã®äœæ¥ãè¡ããŸãã 1. KMP ã ã ã±ãŒãž ã 〠㳠㹠ã ãŒã« ã ãŸãã rpm -ivh rmmod bnx2x 2. 次ã®ã ã ã« ã ã© ã€ãã ã㌠ã ã ãŸãã modprobe bnx2x ãœãŒã¹ TAR ãã¡ã€ã«ããã®ãã©ã€ãã®æ§ç¯ ã¡ã¢ ã ã®æé ã§äœ¿çš ã ããäŸã¯ bnx2x ã ã© ã€ããæ± ã£ ãŠããŸããã bnx2i ã ãã³ bnx2fc ã ã© ã€ãã« ãé©çš ã ããŸãã TAR ãã¡ã€ã«ãããã©ã€ããæ§ç¯ããã«ã¯ã次ã®äœæ¥ãè¡ããŸãã 1.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« 5. ã ã© ã€ãã ãã³ man ããŒãž ã 〠㳠㹠ã ãŒã« ã ãŸãã make install ã¡ã¢ 〠㳠㹠ã ãŒã« ã ããŠãã ã ã© ã€ãã®ä¿åå Žæã¯ã åè¿°ã® RPM ã®èª¬æãåç
§ ã ㊠ã ã ã ãã 6.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠å¿
èŠãª iSCSI 㜠ã ã ㊠㧠㢠㳠ã³ããŒã ã³ ã ã ã㌠ã ã ãŠå®è¡ãã 4. iSCSI ã䜿çšãã ã«ã¯ã 41 ããŒãžã® ãå¿
èŠãª iSCSI 㜠ã ã ㊠㧠㢠㳠ã³ããŒã ã³ ã ã ã㌠ã ã ãŠå®è¡ããã ãåç
§ ã ãŠã å¿
èŠãª 㜠ã ã ㊠㧠㢠㳠ã³ããŒã ã³ ã ã ã㌠ã ã ãŸãã 詳现ã¯æ¬¡ãžã¢ 㯠ã»ã¹ ã ㊠ã ã ã ãã http://linux.dell.com ãã€ã㪠KMOD ããã³ KMP ãã©ã€ãããã±ãŒãžã®ã€ã³ã¹ããŒã« ãã€ããªã«ãŒãã«ã¢ãžã¥ãŒã«ïŒKMODïŒããã³ KMP ãã©ã€ãããã±ãŒãžãã€ã³ã¹ã㌠ã«ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. KMOD ããã³ KMP RPM ã ã© ã€ãã ã ã±ãŒãž ã 〠㳠㹠ã ãŒã« ã ãŸãã ï± SUSE ïŒ netxtreme2-kmp-default-_-...
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux ã ã© ã€ãã®ã¢ ã³ ã㌠ã ãŸãã¯åé€ 2. iSCSI ã ã© ã€ãã ã㌠ã ã ãŸãã ã ããæåã§è¡ ã ã«ã¯ã 以äžã®ããããã® ã³ ã ã³ ã ãçºè¡ ã ãŸãã insmod bnx2i.ko modprobe bnx2i Linux ãã©ã€ãã®ã¢ã³ããŒããŸãã¯åé€ ï® RPM 〠㳠㹠ã ãŒã«ã ãã® ã ã© ã€ãã®ã¢ ã³ ã㌠ã ãŸãã¯åé€ ï® TAR 〠㳠㹠ã ãŒã«ãã ã® ã ã© ã€ãã®åé€ RPM ã€ã³ã¹ããŒã«ããã®ãã©ã€ãã®ã¢ã³ããŒããŸãã¯åé€ ã¡ã¢ ï® ã ã®æé ã§äœ¿çš ã ããäŸã¯ bnx2x ã ã© ã€ããæ± ã£ ãŠããŸããã bnx2fc ããã³ bnx2i ã ã© ã€ãã« ã é©çš ã ããŸãã ï® 2.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠PCI ã ã¡ ã€ã«ãã ã ããã ( ãªã 㷠㧠㳠) TAR ã€ã³ã¹ããŒã«ããã®ãã©ã€ãã®åé€ ã¡ã¢ ã ã®æé ã§äœ¿çš ã ããäŸã¯ bnx2x ã ã© ã€ããæ± ã£ ãŠããŸããã bnx2fc ã ãã³ bnx2i ã ã© ã€ãã« ãé©çš ã ããŸãã TAR ã ã¡ ã€ã«ã ã make install ã䜿 㣠㊠ã ã© ã€ãã 〠㳠㹠ã ãŒã« ã ãå Žåã bnx2x.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ 㯠〠㳠㹠ã ãŒã« 次ã«ã å€ã ã ã¡ ã€ã«ãã ã 㯠㢠ã ã ã ãŠã 䜿çšããæ° ã ã ã ã¡ ã€ã«ã®ååãå€æŽ ã ãŸãã cp /usr/share/hwdata/pci.ids /usr/share/hwdata/old.pci.ids cp /usr/share/hwdata/pci.ids.new /usr/share/hwdata/pci.ids cp /usr/share/hwdata/pcitable /usr/share/hwdata/old.pcitable cp /usr/share/hwdata/pcitable.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ãªã 㷠㧠㳠ã ããã 㣠ã®ããã®å€ã®èšå® int_mode int_mode ã㩠㡠㌠㿠ã¯ã å² ã 蟌ã¿ã¢ãŒ ã ã匷å¶äœ¿çšããå Žåã«äœ¿çš ã ãŸãã int_mode ã㩠㡠㌠㿠ã 1 ã«èšå®ãã ãš ã ã· ã¹ ãã ã®ãã¹ãŠã® BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã§åŸæ¥ã® INTx ã¢ãŒ ã ã匷å¶çã«äœ¿çš ã ããŸãã insmod bnx2x.ko int_mode=1 ãŸã㯠modprobe bnx2x int_mode=1 int_mode ã㩠㡠㌠㿠ã 2 ã«èšå®ãã ãš ã ã· ã¹ ãã ã®ãã¹ãŠã® BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã§ MSI ã¢ãŒ ã ã匷å¶çã«äœ¿çš ã ããŸãã insmod bnx2x.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ãªã 㷠㧠㳠ã ããã 㣠ã®ããã®å€ã®èšå® num_queues ãªã 㷠㧠ã³ã 㩠㡠㌠㿠num_queues ãäœ¿çš ã ãŠã multi_mode ã 1 ã«èšå® ã ãã å² ã 蟌ã¿ã¢ãŒ ã ã MSI-X ã«èšå® ã ããŠã ãå Žåã«ã ã 㥠ãŒã®æ°ãèšå®ã§ ã ãŸãã å² ã 蟌ã¿ã¢ãŒ ã ã MSI-X ãš ç°ãª ãå Žå ïŒ45 ããŒãžã® ãint_modeã ãåç
§ïŒã ã 㥠ãŒã®æ°ã¯ 1 ã«èšå® ã ãã ã ã®ã 㩠㡠㌠㿠ã®å€ã¯ç Žæ£ ã ããŸãã pri_map ãªã 㷠㧠ã³ã 㩠㡠㌠㿠pri_map ã䜿çšãã ãš ã VLAN PRI å€ãŸã㯠IP DSCP å€ã ã㌠ã ㊠㧠ã¢å
ã®ç°ãª ã CoS ãŸãã¯å ã CoS ã«ã ã ã ã ããŸãã ã ã® 32 ã ã ã ãã© ã¡ ã¿ ã¯ã ã ã© ã€ãã« ã 㣠㊠8 ã€ã® 4 ã ã ã ã®å€ ãš ã ãŠè©äŸ¡ ã ããŸãã ã ã®å€ã« ã 㣠ãŠã ãã®åªå
床ã«å¿
èŠãªã㌠ã ㊠㧠ã¢ã 㥠ãŒæ°ãèšå® ã ããŸãã
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ãªã 㷠㧠㳠ã ããã 㣠ã®ããã®å€ã®èšå® time_stamps Enable TCP TimeStamps ïŒTCP 㿠〠ã ã¹ ã¿ ã³ ãã®æå¹åïŒ ã¯ã 㪠ã ã㌠ã iSCSI æ¥ç¶ã§ TCP 㿠〠ã ã¹ ã¿ ã³ ãæ©èœãæå¹ããã³ç¡å¹ã« ã ãŸãã ã ã ã© ã« ã ïŒ TCP 㿠〠ã ã¹ ã¿ ã³ ã ãªã 㷠㧠ã³ã¯ã 㣠㹠ãšãŒãã« ã ããŸãã äŸ ïŒ insmod bnx2i.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ãã®ã ã ã©ã« ã æå¹å€ ïŒ è©²åœãª ã ã¡ ã¢ ïŒ ã ã®ã 㩠㡠㌠㿠ã¯èªã¿å ã å°çšã§ãã ooo_enable Enable TCP out-of-order ïŒTCP out-of-order æ©èœãæå¹ã«ããïŒ æ©èœã¯ã 㪠ã ã㌠ã iSCSI æ¥ç¶ã§ TCP out-of-order RX åŠçæ©èœãæå¹ããã³ç¡å¹ã« ã ãŸãã ã ã ã© ã« ã ïŒ TCP out-of-order æ©èœã¯æå¹ã§ãã äŸ ïŒ insmod bnx2i.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ãã®ã ã ã©ã« ã bnx2 ãã©ã€ãã®ããã©ã«ã é床 ïŒ éç¥ ã ããŠãããã¹ãŠã®é床ã§èªåã㎠㷠ãšãŒã· 㧠㳠Flow Control/ ã ã㌠㳠㳠ã ããŒã« ïŒ éç¥ ã ããŠã ã RX ãš TX ã§èªåã㎠㷠ãšãŒã· 㧠㳠MTU ïŒ 1500 ( ç¯å² 46â9000) RX Ring Size (RX 㪠㳠㰠ãµã€ 㺠) ïŒ 255 ( ç¯å² 0â4080) RX Jumbo Ring Size (RX 㞠㣠㳠ã 㪠㳠㰠ãµã€ 㺠) ïŒ 0 ( ç¯å²ã¯ 0â16320) MTU ã ã ã³ RX Ring Size (RX 㪠㳠㰠ãµã€ 㺠) ã«åºã¥ã㊠ã ã© ã€ããèª¿æŽ TX Ring Size (TX 㪠㳠㰠ãµã€ 㺠) ïŒ 255 ( ç¯å² (MAX_SKB_FRAGS+1)â255)ã MAX_SKB_FRAGS ã¯ã ã« ãŒãã«ãã¢ãŒãã 㯠ã 㣠㫠ã 㣠ãŠç°ãª ã ãŸãã x86 ã® 2.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž TX Ring Size ïŒTX 㪠㳠ã°ãµã€ ãºïŒ ïŒ 4078 ïŒç¯å² ïŒMAX_SKB_FRAGS+4ïŒ -4078ïŒã MAX_SKB_FRAGS ã¯ã ã« ãŒãã«ãã¢ãŒãã 㯠ã 㣠㫠ã 㣠ãŠç°ãª ã ãŸãã x86 ã® 2.6 ã« ãŒãã«ã§ã¯ã MAX_SKB_FRAGS 㯠18 ã§ãã Coalesce RX Microseconds ïŒé£çµ RX ã 〠㯠ãç§ïŒ ïŒ 25 ïŒç¯å² 0â3000ïŒ Coalesce TX Microseconds ïŒé£çµ TX ã 〠㯠ãç§ïŒ ïŒ 50 ïŒç¯å² 0-12288ïŒ Coalesce Statistics Microseconds ïŒé£çµçµ±èšã 〠㯠ãç§ïŒ ïŒ 999936 ïŒçŽ 1 ç§ïŒ ïŒç¯ å² 0â16776960ã å¢å åäœ 256ïŒ MSI-X ïŒ ã€ ããŒãã« (2.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž ãªã³ã¯ã¢ãããšé床ã®è¡šç€º bnx2x: eth# NIC Link is Up, 10000 Mbps full duplex ãªã³ã¯ããŠã³ã®è¡šç€º bnx2x: eth# NIC Link is Down MSI-X Enabled Successfully bnx2x: eth0: using MSI-X bnx2i ãã©ã€ãã¡ãã»ãŒãž bnx2i ã ã© ã€ã ã¡ ã ã»ãŒãžã«ã¯ã 以äžãå«ãŸããŸãã BNX2I ãã©ã€ãã®ãµã€ã³ãªã³ QLogic BCM57xx and BCM57xxx iSCSI Driver bnx2i v2.1.1D (May 12, 2015) iSCSI ãã©ã³ã¹ããŒãååçµåãžã®ãããã¯ãŒã¯ããŒã bnx2i: netif=eth2, iscsi=bcm570x-050000 bnx2i: netif=eth1, iscsi=bcm570x-030c00 ãã©ã€ãã¯ãiSCSI ãªãããŒããæå¹ã«ãã C-NIC ããã€ã¹ãšã®ãã³ãã·ã§ã€ã¯ãå®äºã㟠ã bnx2i [05:00.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž ã¿ãŒã²ããããŒããšãã©ã³ã¹ããŒãååçµåãžã®ãããã¯ãŒã¯ã«ãŒãã¯ã2 ã€ã®ç°ãªããã〠ã¹ã§ã bnx2i: conn bind, ep=0x...
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž C-NIC ã iSCSI ãããã³ã«éåãæ€åºããŸãã - èŽåœçãšã©ãŒ bnx2i: iscsi_error - wrong StatSN rcvd bnx2i: iscsi_error - hdr digest err bnx2i: iscsi_error - data digest err bnx2i: iscsi_error - wrong opcode rcvd bnx2i: iscsi_error - AHS len > 0 rcvd bnx2i: iscsi_error - invalid ITT rcvd bnx2i: iscsi_error - wrong StatSN rcvd bnx2i: iscsi_error - wrong DataSN rcvd bnx2i: iscsi_error - pend R2T violation bnx2i: iscsi_error - ERL0, UO bnx2i: iscsi_error - ERL0, U1 bnx2i: iscsi_error - ERL0,
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž C-NIC ã iSCSI ãããã³ã«éåãæ€åºããŸãã â èŽåœçã§ã¯ãªããèŠåã§ã bnx2i: iscsi_warning - invalid TTT bnx2i: iscsi_warning - invalid DataSN bnx2i: iscsi_warning - invalid LUN field ã¡ã¢ ã ã© ã€ãã¯ã ç¹å®ã®éåãé倧㪠㚠㩠ãŒã§ã¯ãª ã èŠå ãš ã ãŠåŠçãã ã ã ã«èšå® ããå¿
èŠãã ã ãŸãã ãã©ã€ãã¯ãã»ãã·ã§ã³ããªã«ããªãããŸã conn_err - hostno 3 conn 03fbcd00, iscsi_cid 2 cid a1800 ã¿ãŒã²ããããåä¿¡ãã iSCSI PDU ãæåŠããŸã bnx2i - printing rejected PDU contents [0]: 1 ffffffa1 0 0 0 0 20 0 [8]: 0 7 0 0 0 0 0 0 [10]: 0 0 40 24 0 0 ffffff80 0 [18]: 0 0 3 fff
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã ã© ã€ã ã¡ ã ã»ãŒãž ãã©ã€ãã¯ãFCoE ãªãããŒããæå¹ã«ãã C-NIC ããã€ã¹ãšã®ãã³ãã·ã§ã€ã¯ã«å€±æããŸã bnx2fc: init_failure due to invalid opcode bnx2fc: init_failure due to context allocation failure bnx2fc: init_failure due to NIC error bnx2fc: init_failure due to completion status error bnx2fc: init_failure due to HSI mismatch FCoE ãèµ·åããã®ã«æå¹ãªã©ã€ã»ã³ã¹ããããŸãã bnx2fc: FCoE function not enabled bnx2fC: FCoE not supported on èš±å¯ãããæ倧㮠FCoE ãªãããŒãæ¥ç¶å¶éãŸãã¯ã¡ã¢ãªå¶éãè¶
éãããããã»ãã·ã§ã³ã 倱æããŸãã bnx2fc: Failed to allocate conn
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠ã 㣠ãã«çµåã«ã ã ããŒã å æ£ãããªã L2 åä¿¡ãã¬ãŒã ãå»æ£ããŸãã bnx2fc: FPMA mismatch...
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux iSCSI 㪠ã ã㌠ã ãŠãŒã¶ãŒã¢ããªã±ãŒã·ã§ã³ iscsiuio iSCSI æ¥ç¶ãè©Šè¡ããåã«ã iscsiuio ããŒã¢ ã³ ã 〠㳠㹠ã ãŒã« ã ãŠå®è¡ ã ãŸãã ããŒã¢ ã³ã®æ¯æŽããªããã°ã ã ã© ã€ã㯠iSCSI ã¿ ãŒã² ã ã ãžã®æ¥ç¶ã確ç«ã§ ã ãŸããã iscsiuio ããŒã¢ã³ãã€ã³ã¹ããŒã«ããŠå®è¡ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. 次ã®ã ã ã« iscsiuio 㜠ãŒã¹ã ã ã±ãŒãž ã 〠㳠㹠ã ãŒã« ã ãŸãã # tar -xvzf iscsiuio-.tar.gz 2. 次ã®ã ã ã« iscsiuio ãæœåº ã ããã 㣠㬠㯠ã 㪠ã«ç§»å ã ãŸãã # cd iscsiuio- 3. 次ã®ã ã ã« ã³ ã³ãã€ã« ã ㊠〠㳠㹠ã ãŒã« ã ãŸãã # ./configure # make # make install 4.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux iSCSI 㪠ã ã㌠ã 㜠ã ã ㊠㧠㢠〠ã ã· ãšãŒ ã¿ ã䜿 ã ã ã ã«å ã æ¿ã ã ã«ã¯ã 次ãå
¥å ã ãŸãã iscsiadm -m iface -I -n iface.transport_name -v tcp -o update ã ã ã§ã¯ iface ã ã¡ ã€ã«ã«ã¯æ¬¡ã®æ
å ±ãå«ãŸããŸãã iface.net_ifacename = ethX iface.iscsi_ifacename = iface.
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux iSCSI 㪠ã ã㌠ã iSCSI ã¿ãŒã²ãããžã®æ¥ç¶ãäœæãã iscsiadm ã³ ã ã³ ã ã®ç·å 㪠㹠ã ã¯ã Open-iSCSI ã®ãã 㥠ã¢ã«ãåç
§ ã ㊠ã ã ã ãã 以äžã¯ã ã¿ ãŒã² ã ã ãæ€åº ã ãŠã ã¿ ãŒã² ã ã ãžã® iSCSI æ¥ç¶ãäœæãããµã³ ã㫠㪠㹠ã ã§ãã éçãšã³ããªãè¿œå ãã iscsiadm -m node -p -T iqn.2007-05.com.qlogic:target1 -o new -I sendtargets ã䜿çšããŠãiSCSI ã¿ãŒã²ãããæ€åºãã iscsiadm -m discovery --type sendtargets -p -I iscsiadm ã³ãã³ãã䜿çšããŠãã¿ãŒã²ããã«ãã°ã€ã³ãã iscsiadm --mode node --targetname
7âLinux ã ã© ã€ã㜠ã ã ㊠㧠㢠Linux iSCSI 㪠ã ã㌠ã Linux iSCSI ãªãããŒãã® FAQ ï® ãã¹ãŠã® QLogic BCM57xx ããã³ BCM57xxx ã¢ã ã ã¿ ãŒã iSCSI 㪠ã ã㌠ã ããµã㌠ã ããããã§ã¯ã ã ãŸããã ï® iSCSI ã» ã 㷠㧠ã³ã¯ã åçåé€ ãš ã ã ã ã ã© ã°ã®åŸã§ 㪠ã«ã 㪠ã ãŸããã ï® Microsoft Multipath I/O ïŒMPIOïŒ ãé©åã«æ©èœãã ã«ã¯ã å iSCSI ã» ã 㷠㧠㳠㧠iSCSI noopout ãæå¹ã«ããå¿
èŠãã ã ãŸãã noop_out_interval å€ ãš noop_out_timeout å€ãèšå®ããæé ã«ã€ããŠã¯ã Open-iSCSI ã®ãã 㥠ã¢ã«ãåç
§ ã ㊠ã ã ã ãã ï® ã· ã¹ ãã ã«è€æ°ã® C-NIC ãã〠ã¹ãã ã ã ã· ã¹ ãã ã QLogic ã® iSCSI ã㌠ã 㜠㪠㥠ãŒã· 㧠㳠㫠ã ã ã㌠ã ã ããå Žåã ã㌠ã ã¿ ãŒã² ã ã ã® /e
8 VMware ãã©ã€ããœãããŠã§ã¢ æ¬ç« ã§ã¯ã VMware ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã«é¢ãã以äžã®é
ç®ã説æ ã ãŸãã ï® ã ã ã±ãŒãž ã³ ã° ï® ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã ï® 67 ããŒãžã® ãFCoE ãµã㌠ã ã ï® 69 ããŒãžã® ãiSCSI ãµã㌠ã ã ã¡ã¢ æ¬ç« ã®æ
å ±ã¯ã äž»ã«çŸåšãµã㌠ã ã ãã VMware ã®ããŒãž 㧠ã³ã ESXi 6.0 U2ã ESXi 6.5 ããã³ ESXi 6.7 ã«é©çš ã ããŸãã ESXi 6.7 ã¯ãã¹ãŠã®ã ã ã ã³ ã«ã«ã 〠ã 㣠ã ã» ã ã© ã€ããäœ¿çš ã ãŸãã ããã±ãŒãžã³ã° VMware ã ã© ã€ãã¯ã è¡š 8-1 ã«ç€º ã ããŠã ãã ã ã±ãŒãž ã§é
åž ã ããŠããŸãã è¡š 8-1. VMware ãã©ã€ãã®ããã±ãŒãž åœ¢åŒ ãã©ã€ã å§çž®æžã¿ ZIP QLG-NetXtremeIIversion.zip ïŒESXi 6.0, ESXi 6.5ïŒ å§çž®æžã¿ ZIP QLG-qcnic-offline_bundle.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã ãã©ã€ãã®ããŠã³ããŒããã€ã³ã¹ããŒã«ãæŽæ° BCM57xx ããã³ BCM57xxx 10GbE ã ã ã ã¯ãŒ 㯠ã¢ãã ã¿ ãŒçšã® VMware ESXi ã ã© ã€ãã ã㊠㳠ã㌠ã ã 〠㳠㹠ã ãŒã«ã ãŸãã¯ã¢ ã ãã㌠ã ãã ã«ã¯ã http://www.vmware.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã pri_map VLAN PRI å€ãŸã㯠IP DSCP å€ãã ã㌠ã ㊠㧠ã¢å
ã®ç°ãª ã CoS ãŸãã¯å ã CoS ã« ã ã ããã ã«ã¯ã ãªã 㷠㧠ã³ã㩠㡠㌠㿠pri_map ãäœ¿çš ã ãŸãã ã ã® 32 ã ã ã ã ã© ã¡ ã¿ ã¯ã ã ã© ã€ãã« ã 㣠㊠8 ã€ã® 4 ã ã ã ã®å€ ãš ã ãŠè©äŸ¡ ã ããŸãã ã ã®å€ã« ã 㣠ãŠã ãã®åªå
床ã«å¿ ã ãå¿
èŠãªã㌠ã ㊠㧠ã¢ã 㥠ãŒæ°ãèšå® ã ããŸãã ã ãš ãã°ã pri_map ã㩠㡠㌠㿠ã 0x22221100 ã«èšå®ãã ãš ã åªå
床 0 ãš 1 㯠CoS 0 ã«ã ã ã ã ãã åªå
床 2 ãš 3 㯠CoS 1 ã«ã ã ã ã ãã åªå
床 4 ïœ 7 㯠CoS 2 ã«ã ã ã ã ããŸãã å¥ã®äŸ ãš ã ãŠã¯ã pri_map ã㩠㡠㌠㿠ã 0x11110000 ã«èšå® ãã ãš ã åªå
床 0 ïœ 3 㯠CoS 0 ã«ã ã ã
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã enable_default_queue_filters ãªã 㷠㧠ã³ã®ã 㩠㡠㌠㿠㮠enable_default_queue_filters ãäœ¿çš ã ãŠã ã ã ã© ã« ã ã 㥠ãŒã§ã®åé¡ ã 㣠㫠㿠ãæå¹ã« ã ãŸãã ã㌠ã ㊠㧠ã¢ã¯ã ã¢ã ã ã¿ ã®ã㌠ã å
šäœã§ç ã ã åå² ã ããåèš 512 ã®åé¡ ã 㣠㫠㿠ããµã㌠ã ã ãŸãã äŸãã°ã 㯠㢠ã ã ã㌠ã ã¢ã ã ã¿ ã«ã¯ã åã㌠ã ã« 128 ã® ã 㣠㫠㿠ãã ã ãŸãã NPAR ã®æ§æã§ã¯ã ã 㣠㫠㿠ã¯ã ã ã©ã« ã ã®ã 㥠ãŒã«é©çš ã ãã å ã ç©çã㌠ã ã«å±ããããŒã 㣠㷠㧠ã³é ã§ã® ã ã© ã 㣠ã ã¯å ã æ¿ã ããµã㌠ã ã ãŸãã ã 㣠㫠㿠ã®æ°ãã㌠ã ㊠㧠ã¢ã« ã ãå¶éæ°ãè¶
ã ã ãš ããRx filters on NetQ Rx Queue 0 exhausted ã ïŒNetQ R
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã MSI-X ïŒ æå¹ ïŒ2.6 ã« ãŒãã«ã§ãµã㌠ã ã ããå ŽåïŒ TSO ïŒ Enabled WoL ïŒ Disabled ãã©ã€ãã®ã¢ã³ããŒããšåé€ bnx2x VMware ESXi ã ã© ã€ãã 㢠㳠ã㌠ã ãã ã«ã¯ã 次㮠㳠ã ã³ ã ãçºè¡ ã ãŸãã vmkload_mod -u bnx2x ãã©ã€ãã¡ãã»ãŒãž 次㮠bnx2x VMware ESXi ã ã© ã€ã㌠㡠ã ã»ãŒãžã¯ã /var/log/vmkernel.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã ã ã¯ãŒ ã¯æ§ç¯ãµã㌠ã ã ã ã© ã€ã ã¡ã¢ãªã®å¶é ã ã° ã ã¡ ã€ã«å
ã®ä»¥äžã®ã ã 㪠㡠ã ã»ãŒãžã¯ã ESXi ãã¹ ã ãå³éã«å¶é ã ããŠãã ã ãš ã瀺 ã ãŠããŸãã å¶éãç·©åãã ã«ã¯ã NetQueue ãç¡å¹ã« ã ãŸãã Dec 2 18:24:20 ESX4 vmkernel: 0:00:00:32.342 cpu2:4142)WARNING: Heap: 1435: Heap bnx2x already at its maximumSize. Cannot expand. Dec 2 18:24:20 ESX4 vmkernel: 0:00:00:32.342 cpu2:4142)WARNING: Heap: 1645: Heap_Align(bnx2x, 4096/4096 bytes, 4096 align) failed. caller: 0x41800187d654 Dec 2 18:24:20 ESX4 vmkernel: 0:00:00:32.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠FCoE ãµã㌠ã FCoE ãµããŒã æ¬é
ã§ã¯ã QLogic FCoE C-NIC ããµã㌠ã ãã ããã® VMware 㜠ã ã ㊠㧠ã¢ã ã ã±ãŒãžã®ã€ ã³ ã¹ ã ãŒã«ã«é¢é£ ã ãå
容 ãš æé ã«ã€ããŠèª¬æ ã ãŸãã ãã©ã€ã QLogic BCM57xx ã ãã³ BCM57xxx FCoE ã ã© ã€ãã«ã¯ bnx2x ã ãã³ bnx2fc ãã ã ãŸãã ï® bnx2x ã ã© ã€ãã¯ãã¹ãŠã® PCI ãã〠㹠㪠㜠ãŒã¹ ïŒã¬ ãž ã¹ ã¿ ã ãã¹ ã 〠㳠㿠ã 㧠ãŒã¹ã 㥠ãŒãª ã©ïŒ ã管ç ã ã QLogic ã® BCM57xx ããã³ BCM57xxx 10G ãã〠ã¹ã®ã¬ ã€ã€ 2 VMware äœã¬ ãã«ã ã ã ã¯ãŒ 㯠ã ã© ã€ã ãš ã ㊠ãæ©èœ ã 㟠ãã ã ã® ã ã© ã€ãã¯ã㌠ã ㊠㧠㢠ãçŽæ¥å¶åŸ¡ ã ã VMware ãã¹ ã ã ã ã ã¯ãŒãã³ ã° ã¹ ã¿ ã 㯠ã«ä»£ã㣠㊠〠ãŒãµã ã ã ãã± ã ã ã®éåä¿¡ãè¡ããŸãã bnx2x ã
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠FCoE ãµã㌠ã 2. 次ã®ã ã ã«ã FCoE 〠㳠㿠ã 㧠ãŒã¹ ãæå¹ã« ã ãŸãã # esxcli fcoe nic discover -n vmnicX ã ã 㧠X ã¯ã æé 1 ã§å€å¥ ã ãã 〠㳠㿠ã 㧠ãŒã¹çªå·ã§ãã 3.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠iSCSI ãµã㌠ã ã€ã³ã¹ããŒã«ãã§ã㯠ã ã© ã€ããæ£ ã ã 〠㳠㹠ã ãŒã« ã ãã 㹠〠ã ãããã¹ ã ã㌠ã ãèªèãã ã ãš ã確èªã ã ã«ã¯ã 次ã®æé ãå®è¡ ã ãŸãã ãã©ã€ããæ£ããã€ã³ã¹ããŒã«ãããããšã確èªããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. 次ã®ããããã® ã³ ã ã³ ã ãçºè¡ ã ãŠã 㹠〠ã ã ã ã¡ ã 㪠ã 㯠ã 㰠〠㳠ïŒFLOGIïŒ ã㌠㿠ããŒã¹ã«ãã¹ ã ã㌠ã ã衚瀺 ã ãã ã ãš ãç¢ºèª ã ãŸãã show flogi database ïŒCisco FCF ã®å ŽåïŒ fcoe -loginshow ïŒBrocade FCF ã®å ŽåïŒ 2.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠iSCSI ãµã㌠ã 4. éžæ ã ãã vSwitch Properties ïŒvSwitch ã ããã ã£ ïŒ ã® Ports ïŒã㌠ã ïŒ ã㌠㞠ã§ã ä»®æ³ã¹ 〠ã ã ãŸãã¯ã㌠ã ã°ã«ãŒã ã 㯠㪠ã 㯠ã ãŠã Edit ïŒç·šéïŒ ã 㯠㪠ã 㯠ã ãŸãã 5. ïŒãªã 㷠㧠ã³ïŒ VM Network Properties ïŒVM ã ã ã ã¯ãŒ 㯠ã ããã ã£ ïŒ ã® General ïŒäžè¬ïŒ ããŒãž ã§ã VLAN ID ã ã 㯠ã¹ã« VLAN çªå·ãå² ã åœãŠ ãŸãã å³ 8-1 ãš å³ 8-2 ã«äŸã瀺 ã ãŸãã å³ 8-1.
8âVMware ã ã© ã€ã 㜠ã ã ㊠㧠㢠iSCSI ãµã㌠ã å³ 8-2. VM ãããã¯ãŒã¯ããããã£ïŒäŸ 2 6.
9 Windows ãã©ã€ããœãã ãŠã§ã¢ Windows ã ã© ã€ã㜠ã ã ㊠㧠ã¢ã«ã¯æ¬¡ã®æ
å ±ãå«ãŸããŠããŸãã ï® ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« ï® 77 ããŒãžã® ã ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®å€æŽã ï® 78 ããŒãžã® ã ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ä¿®åŸ©ãŸãã¯å〠㳠㹠ã ãŒã«ã ï® 79 ããŒãžã® ããã〠㹠ã ã© ã€ãã®åé€ã ï® 79 ããŒãžã® ãã¢ã ã ã¿ ãŒã®ã ããã 㣠ã®è¡šç€ºãŸãã¯å€æŽã ï® 79 ããŒãžã® ãé»æºã®ç®¡çãªã 㷠㧠ã³ã®èšå®ã ï® 81 ããŒãžã® ãQCC GUIã QCC PowerKitã ããã³ QCS CLI ãš ã®äœ¿çšã®ããã® éä¿¡ã ã ã ã³ ã«ã®èšå®ã ãã©ã€ããœãããŠã§ã¢ã®ã€ã³ã¹ããŒã« ã¡ã¢ ã ã ãã®æé ã¯ã ã䜿ãã® QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã å·¥å Žåºè·æã«å ã ä»ã ãããŠããªã ã ãš ãåæ ãš ã ãŠããŸãã ã䜿ãã® ã³ ã³ ã ã㌠㩠ãå·¥å Žåºè·æã«å ã ä»ã ãããå Žåã
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« ã¡ã¢ ï® ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã 〠㳠㹠ã ãŒã«ããåã«ã Windows ãªã 㬠ãŒã 㣠㳠㰠㷠㹠ãã ãææ°ããŒãž 㧠㳠ã«ã¢ ã ãã° ã¬ãŒ ã ã ãã ææ°ã®ãµãŒã ã¹ã ã ã¯ãé© çš ã ããŠã ã ã ãš ãç¢ºèª ã ㊠ã ã ã ãã ï® QLogic BCM57xx ã ãã³ BCM57xxx ã³ ã³ ã ã㌠㩠ã ã䜿ãã® Windows 㪠ã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã§äœ¿çšã§ ã ã ã ã ã«ãã ã«ã¯ã ã ã ã ã¯ãŒ 㯠ãã〠㹠ã ã© ã€ããç©çç㫠〠㳠㹠ã ãŒã« ã ããŠãã ã ãš ãç¢ºèª ã ㊠ã ã ã ãã ã 㩠〠ãã¯ã€ ã³ ã¹ ã ãŒã« CD ã«å«ãŸããŠããŸãã ï® TCP/IP 㪠ã ã㌠ã ãš ã³ ãž ã³ ïŒTOEïŒ ã䜿çšãã ã«ã¯ã Windows Server 2008ã Windows Server 2008 R2ã ãŸã㯠Windows Serv
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« QLogic BCM57xx ã ãã³ BCM57xxx ãã©ã€ããšç®¡çã¢ããªã±ãŒã·ã§ã³ã®ã€ã³ã¹ã㌠ã«æ¹æ³ïŒ 1. æ°ããããŒããŠã§ã¢ã®æ€çŽ¢ãŠã£ã¶ãŒã ã衚瀺 ã ãã ãã ãã£ã³ã»ã« ã 㯠㪠ã 㯠ã ãŸãã 2. ã ã© ã€ã 㜠ãŒã¹ ã¡ ã 㣠ã¢ã ãŸã㯠㜠ã ã ㊠㧠㢠ã ã© ã€ãã ã ã±ãŒãž ã ã㊠㳠ã㌠ã ã ãå Žæã®ããããã ãã 次ã®äœæ¥ãè¡ããŸãã a. ã䜿ãã®ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã® ã ã© ã«ã ãéã ãŸãã b. MUPS ã ã© ã«ã ãéããŠã ã䜿ãã®ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã ã®èšå®ã« 沿 㣠㊠ã ã©ã«ã ãæœåº ã ãŸãã c. Setup.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« 6. 䜿çšèš±è«Ÿå¥çŽæžãç¢ºèª ã ãåŸã I accept terms in license agreement ïŒã© 〠㻠㳠ã¹å¥çŽã®æ¡ä»¶ã«åæ ã ãŸãïŒ ã 㯠㪠ã 㯠ã ã Next ïŒæ¬¡ãžïŒ ã 㯠㪠ã 㯠ã ãŠç¶è¡ ã ãŸãã 7. 〠㳠㹠ã ãŒã«ããæ©èœãéžæ ã ãŸãã 8. Install ïŒã€ ã³ ã¹ ã ãŒã«ïŒ ã 㯠㪠ã 㯠ã ãŸãã 9. Finish ïŒå®äºïŒ ã 㯠㪠ã 㯠ã ãŠãŠ 㣠ã¶ãŒ ã ãçµäº ã ãŸãã 10.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ã€ ã³ ã¹ ã ãŒã« è¡š 9-1.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®å€æŽ ã¡ã¢ REINSTALL 㹠〠ã ãã¯ã å ã 〠㳠㹠ã ㌠㩠ãã· ã¹ ãã ã«æ¢ã« 〠㳠㹠ã ãŒã« ã ã ãŠã ãå Žåã«ã®ã¿äœ¿çšãã ã ã ã« ã ㊠ã ã ã ãã 以åã®ããŒãž 㧠ã³ã®ã€ ã³ ã¹ ã ㌠㩠ã 㢠ã ã㰠㬠㌠ã ã ãŠããå Žåã¯ã åè¿° ã ããŠã ã ãš ã ã ã setup /s /v/qn ãäœ¿çš ã ㊠ã ã ã ãã ãµã€ã¬ã³ãã€ã³ã¹ããŒã«ãæ©èœå¥ã«å®è¡ããïŒ ADDSOURCE ãäœ¿çš ã ãŠæ¬¡ã®ä»»æã®æ©èœãå«ããŸãã ã ã© ã ã ã ã© ãŒã ã«åºããŠæ¬¡ã® ã³ ã ã³ ã ãçºè¡ ã ãŸãã IA32 ã ã© ã ã ã ã© ãŒã ïŒ setup /s /v"/qn ADDSOURCE=Driversi32,BACSi32,BASPi32,SNMPi32,CIMi32" AMD/EM64T ã ã© ã ã ã ã© ãŒã ïŒ setup /s /v"/qn ADDSOURCE=Driversa64,BACSa64,BASPa
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ä¿®åŸ©ãŸãã¯å〠㳠㹠ã ãŒã« 3. 次㞠ã 㯠㪠ã 㯠ã ãŠç¶è¡ ã ãŸãã 4. å€æŽã è¿œå ã ãŸãã¯åé€ ã 㯠㪠ã 㯠ã ãŠã ã ã ã° ã© ã æ©èœãå€æŽ ã ãŸãã ã¡ã¢ ã ã®ãªã 㷠㧠㳠ã§ã¯æ°èŠã¢ãã ã¿ ãŒçšã® ã ã© ã€ãã¯ã€ ã³ ã¹ ã ãŒã« ã ããŸã ãã æ°èŠã¢ã ã ã¿ ãŒçšã® ã ã© ã€ãã®ã€ ã³ ã¹ ã ãŒã«ã«ã€ããŠã¯ã 78 ããŒãžã® ã ã ã© ã€ã 㜠ã ã ㊠㧠ã¢ã®ä¿®åŸ©ãŸãã¯å〠㳠㹠ã ãŒã«ã ãåç
§ ã ㊠ã ã ã ãã 5. 次㞠ã 㯠㪠ã 㯠ã ãŠç¶è¡ ã ãŸãã 6. 㢠〠㳠㳠ã 㯠㪠ã 㯠ã ãŠã æ©èœã®ã€ ã³ ã¹ ã ãŒã«æ¹æ³ãå€æŽ ã ãŸãã 7. Next ïŒæ¬¡ãžïŒ ã 㯠㪠ã 㯠ã ãŸãã 8. Install ïŒã€ ã³ ã¹ ã ãŒã«ïŒ ã 㯠㪠ã 㯠ã ãŸãã 9.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠ãã〠㹠ã ã© ã€ãã®åé€ ããã€ã¹ãã©ã€ãã®åé€ ãã〠㹠ã ã© ã€ãã®åé€æã¯ã 〠㳠㹠ã ãŒã« ã ããŠãã管ç㢠ã 㪠ã±ãŒã· 㧠㳠ãåé€ ã ããŸãã ã¡ã¢ Windows Server 2008 ã ãã³ Windows Server 2008 R2 ã¯ã ãã〠㹠ã ã© ã€ã ã以å㫠〠㳠㹠ã ãŒã« ã ãã ã㮠㚠眮ãæã ããã〠㹠ã ã© ã€ãã®ããŒã«ã ã 㯠æ©èœãæäŸ ã ãŸãã ãã ã ã BCM57xx ã ãã³ BCM57xxx ãã〠ã¹ã® 㜠ã ã ㊠㧠㢠ã¢ãŒãã 㯠ã ã£ã¯è€éã«ãª 㣠ãŠãã ããã åã
ã® ã³ ã³ ããŒã ã³ ã ã®ã² ãš ã€ã« ããŒã«ã ã ã¯æ©èœã䜿çšãã ãš åé¡ãç ã ãå Žåãã ã ãŸãã ãã®ããã QLogic ã§ã¯ã ã ã© ã€ãããŒãž 㧠ã³ãžã®å€æŽã ã ã© ã€ãã³ ã¹ ã ㌠ã©çµç±ã®ã¿ã§è¡ ã ã ãš ã æšå¥š ã ãŠããŸãã ããã€ã¹ãã©ã€ããåé€ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠é»æºã®ç®¡çãªã 㷠㧠ã³ã®èšå® ã³ã³ãããŒã©ãåžžã«ãªã³ã«ããŠããã«ã¯ã次ã®æé ãå®è¡ããŸãã å³ 9-2 ã«ç€ºãã ã ã«ã ã¢ã ã ã¿ ãŒã ããã 㣠㮠Power Management ïŒé»å管çïŒ ã㌠㞠ã§ã Allow the computer to turn off device to save power ïŒé»åç¯çŽã®ããã« ãã〠㹠ã 㪠ã ã«ãã ã ãš ã ã³ ã³ ã 㥠㌠㿠ã«èš±å¯ããïŒ ã 㧠ã 㯠ã ã 㯠ã¹ã®ã 㧠ã 㯠ã å€ ã ãŸãã ã¡ã¢ é»å管çãªã 㷠㧠ã³ã¯ã ã 㬠㌠ã ãµãŒããŒã§ã¯äœ¿çšã§ ã ãŸããã å³ 9-2.
9âWindows ã ã© ã€ã 㜠ã ã ㊠㧠㢠QCC GUIã QCC PowerKitã ã ãã³ QCS CLI ãš ã®äœ¿çšã®ããã®éä¿¡ã ã ã ã³ã«ã®èšå® 泚æ ããŒã ã® ã¡ ã³ããŒã«ãª 㣠ãŠãã ã¢ãã ã¿ ãŒã«ã¯ã ããã ã Allow the computer to turn off the device to save power ïŒé»åã®ç¯çŽã®ããã«ã ã³ ã³ ã 㥠㌠㿠㧠ã ã®ãã〠ã¹ã®é»æºã 㪠ã ã«ã§ ã ã ã ã ã«ããïŒ ãéžæ ã ãªã㧠ã ã ã ãã QCC GUIãQCC PowerKitãããã³ QCS CLI ãšã® 䜿çšã®ããã®éä¿¡ãããã³ã«ã®èšå® QCC GUIã QCC PowerKitã ããã³ QCS CLI ã®ç®¡ç㢠ã 㪠ã±ãŒã· 㧠㳠ã«ã¯ã RPC ãšãŒãž 㧠㳠ã 㚠㯠㩠〠㢠㳠ã 㜠ã ã ㊠㧠ã¢ã® 2 ã€ã®äž»èŠ ã³ ã³ããŒã ã³ ã ãã ã ãŸãã RPC ãšãŒãž 㧠㳠ã ã¯ã 1 ã€ãŸãã¯è€æ°ã®çµ±åã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒãæèŒ ã ããŠãã ãµãŒã㌠ïŒã管ç察象ãã¹
10 iSCSI ãããã³ã« æ¬ç« ã§ã¯ã iSCSI ã ã ã ã³ ã«ã«é¢ãã次ã®æ
å ±ã«ã€ããŠèª¬æ ã ãŸãã ï® iSCSI ã㌠ã ï® 113 ããŒãžã® ãiSCSI 㯠㩠ã 㷠㥠ã ã³ ãã ï® 113 ããŒãžã® ãWindows Server ã§ã® iSCSI 㪠ã ã㌠ã ã iSCSI ããŒã QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ïŒGbEïŒ ã¢ã ã ã¿ ãŒã¯ã ã 㣠㹠㯠㬠㹠㷠㹠ãã ã§ã®ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã ã®ã ã ã ã¯ãŒ 㯠ã㌠ã ãå¯èœã«ã ã ããã«ã iSCSI ã㌠ã ããµã㌠ã ã ãŸãã iSCSI ã㌠ã ã« ã ã ã 㪠ã¢ãŒ ã ã® iSCSI ã¿ ãŒã² ã ã ã ã· ã³ã ã æšæº IP ã ã ã ã¯ãŒ 㯠ãä» ã ㊠Windowsã Linuxã ãŸã㯠VMware ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã ã㌠ã 㧠ã ãŸãã Windows ãš Linux ã®äž¡æ¹ã®ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã§ã¯ã iSCSI
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã ï® Linux RHEL 6 以éã ã ãã³ SLES 11.1 以é ïŒãª ã ã㌠ã ã ãã³é㪠ã ã㌠ã ã ã¹ ããµã㌠ã ïŒ ï® SLES 10.x ããã³ SLES 11 ïŒé㪠ã ã㌠ã ãã¹ã®ã¿ããµã㌠ã ïŒ ï® IPv4 åãã« VMware ESXi 5.0 以é ïŒé㪠ã ã㌠ã ãã¹ã®ã¿ããµã㌠ã ïŒã IPv6 åãã« ESXi 6.0 以éã ï® ã¬ ã€ ã€ 2 ãã¹å
ã® VMware ESX ã ã ã«ã ã¢ã ã ã¿ ãŒã¯ SLES 11SP3 ã ãã³ SLES12.0 以éã RHEL 6.5ã 6.6ã 7, 7.1 以éã Windows 2012 ã ãã³ Windows 2012 R2 以éã ESXi 6.0 U2 ã ãã³ 6.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã iSCSI ããŒããã©ã¡ãŒã¿ã®èšå® iSCSI ããŒããã©ã¡ãŒã¿ãèšå®ããã«ã¯æ¬¡ã®æé ãè¡ããŸãã 1. NIC èšå®ããŒãžã® Legacy Boot Protocol ïŒã¬ ã¬ã·ãŒã㌠ã ã ã ã ã³ ã«ïŒ ã ã ã ã ããŠã³ ã¡ ã 㥠ãŒã§ã iSCSI ãéžæ ã ãŸã ïŒå³ 10-1 ãåç
§ïŒã å³ 10-1.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 2. QLogic iSCSI ã㌠ã 㜠ã ã ㊠㧠㢠ãã CCMã UEFI ïŒå³ 10-2 ãåç
§ïŒã QCC GUIã ãŸã㯠QCS CLI ã§éçèšå®ãŸãã¯åçèšå®çšã«èšå® ã ãŸãã å³ 10-2.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã General Parameters ïŒäžè¬ã ã© ã¡ ãŒ ã¿ ïŒ ãŠ ã£ ã³ ã ㊠ïŒå³ 10-3 ãåç
§ïŒ ã§äœ¿çšã§ ã ãèšå®ãªã 㷠㧠㳠ãè¡š 10-1 ã«ç€º ã ãŸãã å³ 10-3. UEFIãiSCSI èšå®ãiSCSI äžè¬ãã©ã¡ãŒã¿ è¡š 10-1 ã«ã¯ã IPv4 ãš IPv6 ã®äž¡æ¹ã®ãã© ã¡ ã¿ ã 㪠㹠ã ã ããŸãã IPv4 ãŸã㯠IPv6 ã«åºæãªã 㩠㡠㌠㿠ã«ã¯æ³šèšãä»ããŠããŸãã ã¡ã¢ IPv6 iSCSI ã㌠ã ã䜿çšã§ ã ããã© ã ãã¯ã ã ã© ã ã ã ã© ãŒã ãš ãã〠㹠ã«äŸå ã ãŸãã è¡š 10-1.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã è¡š 10-1.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã è¡š 10-1.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã ï± Boot from Target ïŒ ã¿ ãŒã² ã ã ã ãèµ·åïŒ ïŒ ã¡ ã¢ ãåç
§ ï± DHCP Vendor ID ïŒDHCP ã ã³ ã㌠IDïŒ ïŒ QLGC ISAN ï± Link Up Delay Time ïŒ 0 ï± Use TCP Timestamp ïŒTCP 㿠〠ã ã¹ ã¿ ã³ ã ã䜿çšïŒ ïŒ Enabled ïŒDell ã EMC AX100i 㪠ã©ã®äžéšã® ã¿ ãŒã² ã ã ã§ã¯ã Use TCP Timestamp ïŒTCP 㿠〠ã ã¹ ã¿ ã³ ã ã䜿çšïŒ ãæå¹ã«ããå¿
èŠãã ã ãŸãïŒ ï± Target as First HDD ïŒ Disabled ï± LUN Busy Retry Count ïŒ 0 ï± IP Version ïŒIP ããŒãž 㧠ã³ïŒ ïŒ IPv6 ïŒIPv6ã é㪠ã ã㌠ã ã®å ŽåïŒ ï± HBA Boot Mode ïŒ Disabled ( 泚 ïŒ ã¢ã ã ã¿ ããã«ã ã 㡠㳠㯠㷠㧠㳠ã¢ãŒ ã ã®å Žåã ã ã®ãã© ã¡ ã¿ ã¯å€æŽ
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã å³ 10-4. iSCSI èšå®ãiSCSI ã€ãã·ãšãŒã¿ãã©ã¡ãŒã¿ 4. iSCSI Initiator Parameters ïŒiSCSI 〠ã ã· ãšãŒ ã¿ ã ã© ã¡ ãŒ ã¿ ïŒ ãŠ ã£ ã³ ã ㊠ïŒå³ 10-4ïŒ ã§ã 次ã®é
ç®ã®å€ãå
¥å ã ãŸãã ï± IP 㢠ã 㬠㹠ïŒæªæå®ã® IPv4 ããã³ IPv6 㢠ã 㬠ã¹ã¯ã ãããã ã0.0.0.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã iSCSI First Target Parameters ïŒiSCSI 1 çªç®ã® ã¿ ãŒã² ã ã ãã© ã¡ ãŒ ã¿ ïŒ ãŠ ã£ ã³ ã ãŠã衚瀺 ã ããŸã ïŒå³ 10-5 ãåç
§ïŒã å³ 10-5. iSCSI èšå®ãiSCSI 1 çªç®ã®ã¿ãŒã²ãããã©ã¡ãŒã¿ 7. iSCSI First Target Parameters ïŒiSCSI 1 çªç®ã® ã¿ ãŒã² ã ã ãã© ã¡ ãŒ ã¿ ïŒ ãŠ ã£ ã³ ã ㊠ïŒå³ 10-5ïŒ ã§ã 次ã®æé ãå®è¡ ã ãŸãã a. Connect ïŒæ¥ç¶ïŒ ãæå¹ã« ã ãŠã iSCSI ã¿ ãŒã² ã ã ã«æ¥ç¶ ã ãŸãã b.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã åç iSCSI ããŒãèšå® åç ã³ ã³ ã 㣠㮠㥠ã¬ãŒã· 㧠㳠ã§ã¯ã ã· ã¹ ãã ã® IP 㢠ã 㬠㹠㚠㿠ãŒã² ã ã / 〠ã ã· ãšãŒ ã¿ æ
å ±ã DHCP ãµãŒããŒã« ã 㣠ãŠæäŸ ã ãã ã ãš ãæå®ãã ã ãš ã®ã¿ãå¿
èŠã§ã (94 ããŒãžã® ãiSCSI ã㌠ã ããµã㌠ã ãã ããã® DHCP ãµãŒããŒã®èšå®ã ã«èšèŒ ã ã ãŠã ã IPv4 ããã³ IPv6 èšå®ã®èª¬æãåç
§ ã ㊠ã ã ã ã )ã IPv4 ã®å Žåã 〠ã ã· ãšãŒ ã¿ iSCSI åãé€ãã Initiator Parameters ïŒã€ ãã· ãšãŒ ã¿ ã㩠㡠㌠㿠ïŒã 1st Target Parameters ïŒ1 çªç®ã® ã¿ ãŒã² ã ã ã 㩠㡠㌠㿠ïŒã 㟠ã㯠2nd Target Parameters ïŒ2 çª ç®ã® ã¿ ãŒã² ã ã ãã© ã¡ ãŒ ã¿ ïŒ ã®å㊠㣠㳠ã ãŠã®èšå®ã¯ç¡èŠ ã ãã ããã 㯠㪠ã¢ããå¿
èŠ ã¯ã ã ãŸããã IPv6 ã®å Žåã CHAP I
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 2.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 4. iSCSI First Target Parameters ïŒiSCSI 1 çªç®ã® ã¿ ãŒã² ã ã ãã© ã¡ ãŒ ã¿ ïŒ ãŠ ã£ ã³ ã ãŠã§ã iSCSI ã¿ ãŒã² ã ã ã®èšå®æã«äœ¿çš ã ãå€ãäœ¿çš ã ãŠã 次ã®é
ç®ã®å€ãå
¥ å ã ãŸãã ï± ï± CHAP ID ( åæ¹å CHAP ã®å Žåã¯ä»»æ ) CHAP Secret ïŒCHAP ç§å¯æ
å ±ïŒ ( åæ¹å CHAP ã®å Žåã¯ä»»æãé· ã 㯠12 æå以äžã«ããå¿
èŠãã ã ãŸã ) 5. ESC ããŒãæŒ ã ㊠Main ïŒ ã¡ ã€ ã³ïŒ ã¡ ã 㥠ãŒã«æ» ã ãŸãã 6. ïŒãªã 㷠㧠ã³ïŒ iSCSI Second Target Parameters ïŒiSCSI 2 çªç®ã® ã¿ ãŒã² ã ã ã ã© ã¡ ãŒ ã¿ ïŒ ã¡ ã 㥠ãŒã« CHAP ãè¿œå ã ãŸãã 7.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã è¡š 10-2 ã¯ã 㩠㡠㌠㿠㚠å®çŸ©ã®äžèŠ§ã§ãã è¡š 10-2.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã DHCP ãªã 㷠㧠㳠43 ã䜿çšãã ã«ã¯ã DHCP ãªã 㷠㧠㳠17 ã ã ãå€ ã ã®èšå®ãå¿
èŠ ã§ããã ã ã è±å¯ãªæ©èœãåããç°å¢ãæäŸ ã ãã ã ã å€ ã ã®èšå®ãªã 㷠㧠ã³ãæäŸ ã ããŸãã QLogic ã§ã¯ã åç iSCSI ã㌠ã èšå®ãå®è¡ããå Žåã«ã¯ DHCP ãªã 㷠㧠㳠43 ã䜿çšãã ã ãš ã ãå§ã ã ãŸãã DHCP ãµãŒããŒãèšå®ãã ãªã 㷠㧠㳠17 ãŸãã¯ãªã 㷠㧠㳠43 ããµã㌠ã ãã ã ã ã« DHCP ãµãŒããŒãèšå® ã 㟠ãã ã¡ã¢ ãªã 㷠㧠㳠43 ã䜿çšããå Žåã¯ã ãªã 㷠㧠㳠60 ãèšå®ããå¿
èŠãã ã ãŸãã 㪠ã 㷠㧠㳠60 ã®å€ã¯ã DHCP Vendor ID ïŒDHCP ã ã³ ã㌠IDïŒ å€ ãš äžèŽ ã ãŠã ãå¿
èŠãã ã ãŸãã iSCSI Boot Configuration ïŒiSCSI ã㌠ã èšå®ïŒ ã¡ ã 㥠㌠㮠General Parameters ïŒäžè¬ãã© ã¡ ãŒ
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã DHCPv6 ãªãã·ã§ã³ 17ããã³ãåºææ
å ± DHCPv6 ãªã 㷠㧠㳠17 ( ãã³ ãåºææ
å ± ) ã¯ã ã ã å€ ã ã®èšå®ãªã 㷠㧠㳠ã iSCSI 㯠㩠〠㢠㳠ã ã«æäŸ ã ãŸãã ã ã®èšå®ã§ã¯ã ã㌠ã ã«äœ¿çšã§ ã ã 2 ã€ã® iSCSI ã¿ ãŒã² ã ã IQN ãš å
±ã«ã 〠ã ã· ãšãŒ ã¿ IQN ã iSCSI ã㌠ã 㯠㩠〠㢠㳠ã ã«å² ã åœãŠ ã 3 ã€ã®è¿œå ãµããªã 㷠㧠ã³ãæäŸ ã ããŸãã è¡š 10-4 ã«ãµããªã 㷠㧠㳠ã瀺 ã ãŸãã è¡š 10-4.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã Windows Server 2008 R2 ããã³ SP2 ã® iSCSI ããŒã ã»ããã¢ãã Windows Server 2008 R2 ãš Windows Server 2008 SP2 ã¯ã ã㌠ã ã ã㧠㪠ã ã 㪠ã ã㌠ã / é㪠ã ã㌠ã ãã¹ãžã®ã€ ã³ ã¹ ã ãŒã«ããµã㌠ã ã ãŸãã 次ã®æé ã§ã¯ã 〠㡠ãŒãž ã 㪠ã ã㌠ã 㟠ãã¯é㪠ã ã㌠ã ã㹠㧠〠㳠㹠ã ãŒã«ã ãã³ ã㌠ã ãã ã ã ã«æºå ã ãŸãã æé ã§ã¯ Windows Server 2008 R2 ãå ã äžããŠã㟠ããã Windows Server SP2 ãš å
±éã§ãã å¿
é ã® CD ãŸã㯠ISO 〠㡠ãŒãž ïŒ ï® QLogic ã ã© ã€ãã〠㳠㞠㧠㯠ã ã ãã Windows Server 2008 R2 x64 ïŒ107 ããŒãžã® ãWindows 〠㡠ãŒãž ã ã¡ ã€ã«ãžã® QLogic ã ã© ã€ãã®ã€ 㳠㞠㧠㯠ã ïŒã¹ 㪠ã ã ã¹ ã 㪠ãŒã ïŒ
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 7. iSCSI ã¿ ãŒã² ã ã ã ã© ã¡ ã¿ ãå
¥å ã ãŸãã 8. [HBA Boot Mode] ã [Enabled] ãŸã㯠[Disabled] ã«èšå® ã ãŸãã ( 泚 ïŒ ã¢ã ã ã¿ ããã«ã ã 㡠㳠㯠㷠㧠㳠ã¢ãŒ ã ã®å Žåã ã ã®ãã© ã¡ ã¿ ã¯å€æŽã§ ã ãŸããã ) 9. èšå®ãä¿å ã ãŠã ã· ã¹ ãã ãåèµ·å ã ãŸãã 㪠ã¢ãŒ ã ã· ã¹ ãã 㯠iSCSI ã¿ ãŒã² ã ã ã«æ¥ç¶ ã ã DVDROM ãã〠ã¹ã ã ã㌠ã ã ãŸãã 10. DVD ãžã®ã㌠ã ãå®è¡ ã ãŠã 〠㳠㹠ã ãŒã«ãéå§ ã ãŸãã 11.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã ã¡ã¢ Microsoft ã®æé ã§ã¯ã EVBD ã ãã³ NDIS ã® ã ã© ã€ãã®ã¿ã 〠㳠㞠㧠㯠ã ã 㟠ãã ãã¹ãŠã® ã ã© ã€ã ïŒEVBDã VBDã BXNDã OISã FCoEã ããã³ NDISïŒ ã 〠㳠㞠㧠㯠ã ãã ã ãš ã ãå§ã ã ãŸãã ã€ã¡ãŒãžããªãããŒããŸãã¯éãªãããŒããã¹ã§ã€ã³ã¹ããŒã«ããã³ããŒãããããã« æºåããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. ã㌠ã ã ã ã ãš ãã ã· ã¹ ãã ( ã 㪠ã¢ãŒ ã ã· ã¹ ãã ã ) ã ã ãã¹ãŠã®ã㌠ã«ã« ã㌠ã ã 㩠〠ã ãå ã å€ ã ãŸãã 2. ææ°ã® QLogic MBA ãš iSCSI ã㌠ã 〠㡠ãŒãž ã ã¢ã ã ã¿ ãŒã® NVRAM ã« ã㌠ã ã ãŸãã 3. QLogic MBA ãæåã®ã㌠ã å¯èœãã〠ã¹ã CDROM ã 2 çªç®ã®ãã〠ã¹ã«ãª ã ã ã ã«ã 㪠ã¢ãŒ ã ã· ã¹ ãã ã® BIOS ãèšå® ã ãŸãã 4.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 12. Next ïŒæ¬¡ãžïŒ ãéžæ ã ã Windows Server 2012 ãŸã㯠2016 ã®ã€ ã³ ã¹ ã ãŒã«ã« é²ã¿ãŸãã Windows Server 2012 ãŸã㯠2016 DVD ã« ã ã 〠㳠㹠ã ãŒã«ã ã ã»ã¹ãéå§ ã ã ãŠã ãæ°ååŸã«ã ã· ã¹ ãã ãåèµ·å ã ããŸãã åèµ·ååŸã« Windows Server 2012 ãŸã㯠2016 〠㳠㹠ã ãŒã« ã«ãŒã ã³ãåé ã ãã 〠㳠㹠ã ãŒã«ãå®äº ã ãŸãã 13. ã ã äžåºŠã· ã¹ ãã ãåèµ·å ã ãåŸã 㪠ã¢ãŒ ã ã· ã¹ ãã ãèµ·å ã ãã㹠㯠ã ã ãã æ£åžžã«è¡šç€º ã ãã ã ãš ãç¢ºèª ã ãŸãã 14.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 7. networking device æ瀺 ã¡ ã ã»ãŒãž ã§ã å¿
èŠãªã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒã㌠ã ãéžæ ã ã OK ã 㯠㪠ã 㯠ã ãŸãã 8. configure TCP/IP æ瀺 ã¡ ã ã»ãŒãž ã§ã ã· ã¹ ãã ã IP 㢠ã 㬠㹠ãååŸããæ¹ æ³ãèšå® ã ã OK ã 㯠㪠ã 㯠ã ãŸãã 9. static IP ïŒéç IPïŒ ãéžæ ã ãå Žåã iSCSI 〠ã ã· ãšãŒ ã¿ ã® IP æ
å ±ãå
¥åããå¿
èŠãã ã ãŸãã 10. (RHEL) ã¡ ã 㣠㢠ã ã¹ ã ã® [ çç¥ ] ãéžæ ã ãŸãã 11. å¿
èŠã«å¿ ã ㊠〠㳠㹠ã ãŒã«ãç¶è¡ ã ãŸãã ã ã®æç¹ã§ã ã 㩠〠ããå©çšå¯èœã«ãª ã ãŸãã ã ã¡ ã€ã«ã® ã³ ããŒãå®äº ã ã ãã CD ãŸã㯠DVD ãå ã åº ã ãŠã ã· ã¹ ã ã ãåèµ·å ã ãŸãã 12.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 12. initrd 〠㡠ãŒãž ïŒãª ã ã㌠ã 㟠ãã¯é㪠ã ã㌠ã ïŒ ã /boot ã ã© ã«ãã« ã³ ã㌠ã ãŸãã 13. grub ã¡ ã 㥠ãŒãå€æŽ ã ãŠæ° ã ã initrd 〠㡠ãŒãž ãã 〠㳠ã ãã ã ã ã« ã ãŸãã 14. CHAP ã 〠ããŒãã«ã«ãã ã«ã¯ã iscsid.conf ãå€æŽããå¿
èŠãã ã ãŸã (Red Hat ã®ã¿ )ã 15. åèµ·å ã ãŸãã 16. ïŒãªã 㷠㧠ã³ïŒ CAHP ã㩠㡠㌠㿠ãå€æŽ ã ãŸãã 17.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã # Default-Start: B # Default-Stop: # Short-Description: iSCSI initiator daemon root-fs support # Description: Starts the iSCSI initiator daemon if the # root-filesystem is on an iSCSI device # ### END INIT INFO ISCSIADM=/sbin/iscsiadm ISCSIUIO=/sbin/iscsiuio CONFIG_FILE=/etc/iscsid.conf DAEMON=/sbin/iscsid ARGS="-c $CONFIG_FILE" # Source LSB init functions ./etc/rc.status # # This service is run right after booting.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã done } # Reset status of this service rc_reset # We only need to start this for root on iSCSI if ! grep -q iscsi_tcp /proc/modules ; then if ! grep -q bnx2i /proc/modules ; then rc_failed 6 rc_exit fi fi case "$1" in start) echo -n "Starting iSCSI initiator for the root device: " iscsi_load_iscsiuio startproc $DAEMON $ARGS rc_status -v iscsi_mark_root_nodes ;; stop|restart|reload) rc_failed 0 ;; status) echo -n "Checking for iSCSI initiator service: " if checkproc $DAEMON ; th
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã Windows OS ã€ã¡ãŒãžããã€ã³ããã¯ã¹ãã©ã€ããåé€ãã 1. D:\temp 㪠ã©ã®äžæã 㣠㬠㯠ã 㪠ãäœæ ã ãŸãã 2. äžæ ã ã© ã«ãå
ã«æ¬¡ã® 2 ã€ã®ãµã ã ã©ã«ã ãäœæ ã ãŸãã ï± ï± 3. Win2008R2Copy Win2008R2Mod DVD 〠㳠㹠ã ãŒã« ã¡ ã 㣠ã¢ã®ãã¹ãŠã®å
容ã Win2008R2Copy ã ã© ã«ãã« ã³ ã㌠ã ãŸãã 4. All program ïŒãã¹ãŠã®ã ã ã° ã© ã ïŒ ã ã Windows èªå〠㳠㹠ã ãŒã«ã ã ã ïŒAIKïŒ ã® ã³ ã ã³ ã ã ã ã³ ã ã ã管çè
æš©éã¢ãŒ ã ã§éãã 次㮠㳠ã ã³ ã ãçºè¡ ã ãŸãã attrib -r D:\Temp\Win2008R2Copy\sources\boot.wim 5. 次㮠㳠ã ã³ ã ãçºè¡ ã ãŠã boot.wim 〠㡠ãŒãž ã ã㊠㳠ã ã ãŸãã dism /Mount-WIM /WimFile:D:\Temp\W
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã Windows ã€ã¡ãŒãž ãã¡ã€ã«ãžã® QLogic ãã©ã€ãã®ã€ã³ãžã§ã¯ãïŒã¹ãªãã ã¹ããªãŒã ïŒ æé ã«ã€ããŠã¯ã FCoE ã® ã ã ã 㯠ãåç
§ ã ㊠ã ã ã ãã Windows 〠㡠ãŒãž ã ã¡ ã€ã«ã« QLogic ã ã© ã€ãã 〠㳠㞠㧠㯠ã ãã ã«ã¯ã 該åœãã Windows Server ã®ããŒãž 㧠㳠(2008 R2ã 2008 SP2ã 2012ã ãŸã㯠2012 R2) ã® ã ã© ã€ã〠㳠㹠ã ãŒã«ã ã ã±ãŒãž ãååŸããå¿
èŠãã ã ãŸãã ã ãã ã® ã ã© ã€ãã ã ã±ãŒãž ãäœæ¥ã 㣠㬠㯠ã 㪠ã«é
眮 ã ãŸãã ã ãš ãã°ã äœ¿çš ã ãŠã ã Windows Server ããŒãž 㧠㳠ã«é© ã ããã¹ãŠã® ã ã© ã€ãã ã ã±ãŒãžã ãã³ ã ã¡ ã€ã«ã æé 3 ã®äŸã® ã ã© ã«ãäœçœ®ã« ã³ ã㌠ã ãŸãã ï® C:\Temp\drivers æåŸã«ã ã ã ãã® ã ã© ã€ãã Windows 〠㡠ãŒãž (WIM) ã ã¡ ã€ã«
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 6. 次㮠㳠ã ã³ ã ãçºè¡ ã ãŸãã attrib -r .\src\sources\boot.wim attrib -r .\src\sources\install.wim 7. 次㮠㳠ã ã³ ã ãçºè¡ ã ã boot.wim 〠㡠ãŒãž ã ã㊠㳠ã ã ãŸãã dism /mount-wim /wimfile:.\src\sources\boot.wim /index:2 /mountdir:.\mnt ã¡ ã¢ ïŒ ã€ ã³ã ã 㯠ã¹ã®å€ ãš ã ãŠåžžã« ã2ã ã䜿çšããå¿
èŠãã ã ãŸãã 8. 次㮠㳠ã ã³ ã ãçºè¡ ã ã çŸåšã㊠㳠ã ã ããŠãã 〠㡠ãŒãžã«æ¬¡ã® ã ã© ã€ããè¿œå ã ãŸãã dism /image:.\mnt /add-driver /driver:C:\Temp\drivers /Recurse /ForceUnsigned 9. 次㮠㳠ã ã³ ã ãçºè¡ ã ã boot.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 16. DVD æžã蟌ã¿ã¢ ã 㪠ã±ãŒã· 㧠㳠ãäœ¿çš ã ã äœæ ã ã .iso ã ã¡ ã€ã«ã DVD ã«æž ã蟌ã¿ãŸãã 17. åã®æé ã§äœæ ã ã DVD ãäœ¿çš ã ã 該åœãã Windows Server ã®ããŒãž 㧠㳠ã 〠㳠㹠ã ãŒã« ã ãŸãã ããŒã ãã®åŸã ã· ã¹ ãã ã§ã¯ iSCSI ã㌠ã ã®æºåãå®äº ã ã ãªã ã¬ãŒã 㣠㳠㰠㷠㹠ãã ã iSCSI ã¿ ãŒã² ã ã ã«ååš ã ãŸãã æåŸã®ã¹ ã ã ã ã§ã¯ã å®éã®ã㌠ã ãå®è¡ ã ãŸãã ã· ã¹ ãã ã¯ã ã ã ã ã¯ãŒ 㯠ãä» ã ㊠Windows ãŸã㯠Linux ãèµ·å ã ã Windows ãã㌠ã«ã« ã 㣠㹠㯠ã 㩠〠ãäžã«ã ããã®ã ã ã«åäœ ã ãŸãã 1. ãµãŒããŒãåèµ·å ã ãŸãã 2. CTRL+S ããŒãæŒ ã ãŸãã 3.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã iSCSI ããŒãã€ã¡ãŒãžãäœæãããDDãæ¹æ³ 㪠ã¢ãŒ ã iSCSI ã¿ ãŒã² ã ã ãžã®çŽæ¥ã®ã€ ã³ ã¹ ã ãŒã«ããªã 㷠㧠㳠㧠ãªãå Žåã¯ã 代ã ã ã« ãDDã æ¹æ³ãäœ¿çš ã ãŠã ã ã®ã ã 㪠〠㡠ãŒãž ãäœæ ã ãŸãã ã ã®æ¹æ³ã§ã¯ã 〠㡠ãŒãž ã ã㌠ã«ã«ã㌠ã ã 㩠〠ãã«çŽæ¥ã€ ã³ ã¹ ã ãŒã« ã ãŠã ã ã 以éã®ã㌠ã çšã« iSCSI ã㌠ã 〠㡠ãŒãž ãäœæ㧠ã ãŸãã ãDDã㧠iSCSI ããŒãã€ã¡ãŒãžãäœæããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. Linux OS ã ã㌠ã«ã« ã㌠ã ã 㩠〠ã㫠〠㳠㹠ã ãŒã« ã ã Open-iSCSI 〠ã ã· ãšãŒ ã¿ ãææ°ã§ã ã ã ãš ãç¢ºèª ã ãŸãã 2. ã ã ã ã¯ãŒ ã¯ãµãŒã ã¹ã®ãã¹ãŠã®å®è¡ã¬ ãã«ã㪠㳠ã«ãª 㣠ãŠãã ã ãš ãç¢ºèª ã 㟠ãã 3.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã 16. æé 14 ã§ããŠã³ ã ã ãããŒã 㣠㷠㧠㳠ã§ã grub ã¡ ã 㥠ãŒãç·šé ã ãŠæ° ã ã initrd 〠㡠ãŒãž ã ã 〠㳠ã ãã ã ã ã« ã ãŸãã 17. /boot ããŒã 㣠㷠㧠㳠ã iSCSI ã¿ ãŒã² ã ã ã ã 㢠㳠ã㊠㳠ã ã ãŸãã 18. ïŒRed Hat ã®ã¿ïŒ CHAP ãæå¹ã«ãã ã«ã¯ã iSCSI ã¿ ãŒã² ã ã äžã® iscsid.conf ã ã¡ ã€ã«ã® CHAP 㻠㯠㷠㧠㳠ãå€æŽããå¿
èŠãã ã ãŸãã å¿
èŠ ã«å¿ ã ãŠã iscsid.conf ã ã¡ ã€ã«ãäžæ¹å㟠ãã¯åæ¹åã® CHAP æ
å ±ã§ç·šé ã ãŸãã 19. ã· ã¹ ãã ã 㷠㣠ã ã ã㊠㳠ã ã ã㌠ã«ã« ã㌠ã ã 㩠〠ã ãåæ ã ãŸãã ã ãã§ã iSCSI ã¿ ãŒã² ã ã ã® iSCSI ã㌠ã ã®æºåãå®äº ã 㟠ã ãã 20.
10âiSCSI ã ã ã ã³ ã« iSCSI ã㌠ã ãã©ãã« ïŒ iSCSI ã㌠ã ã Microsoft æšæºãã¹ãã QLogic iSCSI 㪠ã ã㌠ã ã«å ã æ¿ ã ã ãš ã ã㌠ã ãéäžã§å€±æããã è§£æ±ºæ³ ïŒ iSCSI ã㌠ã ãã¹ ãå ã æ¿ã ãåã«ã QLogic Virtual Bus Device ïŒVBDïŒ ã ã© ã€ã ãš OIS ã ã© ã€ãã 〠㳠㹠ã ãŒã«ãããã ææ°ããŒãž 㧠㳠ã«ã¢ ã ã㰠㬠㌠ã ã ㊠ã ã ã ãã ãã©ãã« ïŒ iSCSI èšå®ãŠãŒã 㣠㪠ã 㣠ãåäœ ã ãªãã è§£æ±ºæ³ ïŒ iSCSI ã㌠ã ã ã¡ ãŒã ㊠㧠ã¢ã NVRAM 㫠〠㳠㹠ã ãŒã« ã ããŠã ã ã ãš ãç¢ºèª ã ㊠ã ã ã ãã ãã©ãã« ïŒ Windows ã ã© ã°ã¢ ã³ ã ã 㬠〠ïŒPnPïŒ ã§ QLogic ã ã© ã€ãã 〠㳠㹠ã ãŒã« ãã ãš ã ã· ã¹ ãã 㧠ãã«ãŒã¹ 㯠㪠ãŒã³ã衚瀺 ã ããã è§£æ±ºæ³ ïŒ ã» ã ã 㢠ã ã 〠㳠㹠ã ㌠㩠ã ã ã ã©
10âiSCSI ã ã ã ã³ ã« iSCSI 㯠㩠ã 㷠㥠ã ã³ ã ã ã© ãã« ïŒ Windows Server 2008 以äžãäœ¿çš ã ㊠EqualLogic ã¿ ãŒã² ã ã ã«æ¥ç¶ã§ ã ãªãã è§£æ±ºæ³ ïŒ ã 㡠〠ã¢ãŠ ã© ãŒã«ã«äŸå€ãè¿œå ã ãŠã ICMP 㚠㳠㌠㪠㯠㚠㹠ã ãèš±å¯ ã ㊠ã ã ã ãã ã ã© ãã« ïŒ 1Gbps ã®ã¹ 〠ã ãã㌠ã ã«æ¥ç¶ ã ãŠã ãå Žåã iSCSI ã㌠ã ã« ã ã iSCSI ã¿ ãŒã² ã ã ãžã® Windows ã®ã€ ã³ ã¹ ã ãŒã«ã倱æããã è§£æ±ºæ³ ïŒ ã ã®å€±æã¯ã ç©çæ¥ç¶ ãš ã ㊠SFP+ ã䜿çšãã ã¢ã ã ã¿ ãŒã«é¢é£ããå¶é㧠ãã SFP+ ã®ã ã ã© ã« ã 㯠10Gbps ã®åäœã§ã ã ã èªåã㎠㷠ãšãŒã· 㧠㳠ããµã㌠ã ã ãŠããŸããã iSCSI ã¯ã©ãã·ã¥ãã³ã QLogic iSCSI Crash Dump ãŠãŒã 㣠㪠ã 㣠ã䜿çšããå Žåã iSCSI Crash Dump ã ã© ã€ãã 〠㳠㹠ã ãŒã«ããå¿
èŠãã ã ãŸ
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã QLogic ãã©ã€ãããã³ç®¡çã¢ããªã±ãŒã·ã§ã³ã®ã€ã³ã¹ããŒã« Windows ã ã© ã€ã 㚠管ç㢠ã 㪠ã±ãŒã· 㧠㳠ã 〠㳠㹠ã ãŒã« ã ãŸãã Microsoft iSCSI Initiator ã®ã€ã³ã¹ããŒã« Windows Server 2008 以éã§ã¯ã iSCSI 〠ã ã· ãšãŒ ã¿ ã¯æšæºã§å«ãŸããŠããŸãã Microsoft ã ã iSCSI 〠ã ã· ãšãŒ ã¿ ã ã㊠㳠ã㌠ã ãã ã«ã¯ã 次ã®å Žæã«ã¢ 㯠ã»ã¹ ã ãŠã ã䜿ãã®ã· ã¹ ãã çšã®ã 〠㬠㯠ã 㪠㳠㯠ãæ¢ ã ãŸãã http://www.microsoft.com/en-us/download/details.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã å³ 10-6.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã 3. Initiator Node Name Change ïŒã€ ã ã· ãšãŒ ã¿ ã ㌠ã åå€æŽïŒ ã 〠㢠ã ã°ã ã 㯠㹠ïŒå³ 10-7 ãåç
§ïŒ ã§ã æ° ã ã 〠ã ã· ãšãŒ ã¿ ã® IQN åãå
¥å ã ãŠã OK ã 㯠㪠ã 㯠ã ãŸãã å³ 10-7. ã€ãã·ãšãŒã¿ããŒãåã®å€æŽ 4.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã å³ 10-8. iSCSI Initiator PropertiesïŒiSCSI ã€ãã·ãšãŒã¿ããããã£ïŒïŒDiscoveryïŒæ€åºïŒ ããŒãž 5. Add Target Portal ïŒ ã¿ ãŒã² ã ã ã㌠㿠ã«ã®è¿œå ïŒ ã 〠㢠ã ã°ã ã 㯠㹠ïŒå³ 10-9 ãåç
§ïŒ ã§ã ã¿ ãŒã² ã ã ã® IP 㢠ã 㬠㹠ãå
¥å ã ãŠã Advanced ïŒè©³çŽ°èšå®ïŒ ã 㯠㪠ã 㯠ã ãŸãã å³ 10-9.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã 6. Advanced Settings ïŒè©³çŽ°èšå®ïŒ ã 〠㢠ã ã°ã ã 㯠㹠ã§ã 次ã®ã ã ã« General ïŒäžè¬ïŒ ããŒãžã«æ
å ±ãå
¥å ã ãŸãã a. Local adapter ïŒã㌠ã«ã«ã¢ã ã ã¿ ãŒïŒ ã§ã QLogic BCM57xx ã ãã³ BCM57xxx C-NIC iSCSI ã¢ãã ã¿ ãŒãéžæ ã ãŸãã b. Source IP ïŒ ãœ ãŒã¹ IPïŒ ã§ã ã¢ã ã ã¿ ãŒã® IP 㢠ã 㬠㹠ãéžæ ã ãŸãã c. Advanced Settings ïŒè©³çŽ°èšå®ïŒ ã 〠㢠ã ã°ã ã 㯠㹠ãé ã ã ã«ã¯ã å€æŽã ä¿å ã ãŠã OK ã 㯠㪠ã 㯠ã ãŸãã å³ 10-10 ã¯ãã®äžäŸã§ãã å³ 10-10.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã 7. iSCSI Initiator Properties ïŒiSCSI 〠ã ã· ãšãŒ ã¿ ã ããã ã£ ïŒ ã§ Discovery ïŒæ€ åºïŒ ã¿ ã ã 㯠㪠ã 㯠ã ã Discovery ïŒæ€åºïŒ ããŒãž 㧠OK ã 㯠㪠ã 㯠ã ㊠㿠㌠㲠ã ã ã㌠㿠ã«ãè¿œå ã ãŸãã å³ 10-11 ã¯ãã®äžäŸã§ãã å³ 10-11. iSCSI Initiator PropertiesïŒiSCSI ã€ãã·ãšãŒã¿ããããã£ïŒïŒDiscovery ïŒæ€åºïŒããŒãž 8.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã 9. Targets ïŒ ã¿ ãŒã² ã ã ïŒ ããŒãž 㧠㿠ãŒã² ã ã ãéžæ ã ã Log On ïŒã ã°ãª ã³ïŒ ã 㯠㪠ã 㯠ã ãŠã QLogic iSCSI ã¢ã ã ã¿ ãŒãäœ¿çš ã ãŠã ã iSCSI ã¿ ãŒã² ã ã ã« ã 㰠㪠㳠ã ãŸãã å³ 10-12 ã¯ãã®äžäŸã§ãã å³ 10-12. iSCSI Initiator PropertiesïŒiSCSI ã€ãã·ãšãŒã¿ããããã£ïŒïŒ TargetsïŒã¿ãŒã²ããïŒããŒãž 10. Log On To Target ïŒ ã¿ ãŒã² ã ã ã« ã ã°ãª ã³ïŒ ã 〠㢠ã ã°ã ã 㯠㹠ïŒå³ 10-13ïŒ ã§ã Advanced ïŒè©³çŽ°èšå®ïŒ ã 㯠㪠ã 㯠ã ãŸãã å³ 10-13.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã 11. Advanced Settings ïŒè©³çŽ°èšå®ïŒ ã 〠㢠ã ã°ã ã 㯠ã¹ã® General ïŒäžè¬ïŒ ããŒãž ã§ã Local adapter ïŒã㌠ã«ã«ã¢ã ã ã¿ ãŒïŒ ãš ã ㊠QLogic BCM57xx ã ãã³ BCM57xxx C-NIC iSCSI ã¢ãã ã¿ ãŒãéžæ ã ã OK ã 㯠㪠ã 㯠ã ãŸãã å³ 10-14 ã¯ãã®äžäŸã§ãã å³ 10-14. Advanced SettingsïŒè©³çŽ°èšå®ïŒ ïŒGeneralïŒäžè¬ïŒããŒãžãLocal Adapter ïŒããŒã«ã«ã¢ããã¿ãŒïŒ 12. [OK] ã 㯠㪠ã 㯠ã ㊠Microsoft Initiator ãé ã ãŸãã 13.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã ã¡ã¢ ï® ããŒã å㯠iSCSI ã¢ã ã ã¿ ãŒããµã㌠ã ã ãŠããŸããã ï® ããŒã åã¯ã㌠ã ãã¹å
ã® NDIS ã¢ã ã ã¿ ãŒããµã㌠ã ã ãŠããŸããã ï® ããŒã åã¯ã SLB ããŒã 㿠〠ãã®å Žåã«é ã ã iSCSI ã㌠ã ãã¹ã®å€ã«ã ã NDIS ã¢ã ã ã¿ ãŒããµã㌠ã ã ãŸãã iSCSI ãªãããŒãã® FAQ 質å ïŒ iSCSI 㪠ã ã㌠ã ã« IP 㢠ã 㬠㹠ãå² ã åœãŠ ã ã«ã¯ã©ã®ã ã ã«ããã°ããã§ã ãïŒ åç ïŒ QLogic Control Suite ïŒQCSïŒ ã® Configurations ïŒèšå®ïŒ ããŒãž ãäœ¿çš ã ㊠ã ã ã ãã 質å ïŒ ã¿ ãŒã² ã ã ãžã®æ¥ç¶ãäœæããã®ã«ã©ã®ããŒã«ã䜿çšãã¹ã ã§ããïŒ åç ïŒ Microsoft iSCSI Software Initiator ïŒããŒãž 㧠㳠2.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã è¡š 10-5.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã è¡š 10-5.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã è¡š 10-5.
10âiSCSI ã ã ã ã³ ã« Windows Server ã§ã® iSCSI 㪠ã ã㌠ã è¡š 10-5.
11 QLogic ããŒã åãµãŒãã¹ æ¬ç« 㯠Windows Server ã· ã¹ ãã ïŒWindows Server 2016 以éã¯é€ ã ïŒ ã§ã®ã¢ã ã ã¿ ã®ã㌠ã ã³ ã°ã«ã€ããŠèª¬æ ã ãŸãã ä»ã®ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã ã§ã®é¡äŒŒã®æè¡ ( ã ãš ãã°ã Linux ã® ãã 㣠ãã«çµåã ) ã®è©³çŽ°ã¯ã 該åœãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã®ãã 㥠ã¢ã«é¡ãåç
§ ã ㊠ã ã ã ãã ï® èŠæš ï® 143 ããŒãžã® ãããŒã åã®ä»çµã¿ã ï® 153 ããŒãžã® ãããŒã å ãš ãã®ä»ã®è©³çŽ°ãªã ã ã ã¯ãŒ 㯠ã ããã 㣠ã ï® 157 ããŒãžã® ãå
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
ã ï® 166 ããŒãžã® ã㢠ã 㪠ã±ãŒã· 㧠㳠ã«é¢ããèæ
®äºé
ã ï® 174 ããŒãžã® ãããŒã åã«é¢ããåé¡ã® ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã ï® 177 ããŒãžã® ãã ã ã ã質åã ï® 180 ããŒãžã® ã〠ãã³ ã ã ã°ã® ã¡ ã ã»ãŒãžã èŠæš QLogic ããŒã åãµãŒã ã¹ã®èª¬æã¯ä»¥äžã®é
ã«ãŸ
11âQLogic ããŒã åãµãŒã ã¹ èŠæš æ¬é
ã§ã¯ã ã ã ã ã¯ãŒ 㯠ããŒã åãµãŒã ã¹ ã䜿çšããéã®æè¡ã ãã³å®è£
ã®èæ
®äºé
ã« ã€ããŠèª¬æ ã ãŸãã ã ã®ãµãŒã ã¹ã¯ã Dell 補ãµãŒããŒããã³ã¹ ã ã¬ãŒãžè£œåã«å梱 ã ã ãŠã ã QLogic 㜠ã ã ㊠㧠ã¢ã« ã 㣠ãŠæäŸ ã ããŸãã QLogic ã®ããŒã åãµãŒã ã¹ã®ç® çã¯ã è€æ°ã®ã¢ã ã ã¿ ãŒã ã 㪠ã ããŒã å
šäœã« ã ã© ãŒã« ã ã 㬠㩠㳠㹠㚠㪠㳠ã¯éçŽãæ äŸãã ã ãš ã§ãã æ¬æžã®å
容ã¯ã IT ã ã ã 㧠ã 㷠㧠ãã«ãã ã ã ã ã¯ãŒ 㯠ã ã© ãŒã« ã ã ã¬ ã© ã³ ã¹ ãš è² è·ãã© ã³ ã· ã³ ã° ãå¿
èŠ ãš ãã ã· ã¹ ãã 㢠ã 㪠ã±ãŒã· 㧠㳠ãå°å
¥ ã ã ã© ã㫠㷠㥠ãŒã 㣠㳠ã°ããéã«åœ¹ç«ã¡ ãŸãã çšèªé è¡š 11-1 ã¯ã ããŒã åã§äœ¿çš ã ããçšèªãå®çŸ© ã ãŠããŸãã è¡š 11-1.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš è¡š 11-1. çšèªé ( ç¶ã ) çšèª å®çŸ© 㪠㳠ã¯éçŽ ïŒ802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ãããã¯ãŒã¯ã¢ãã¬ã¹æå® ããŒã åã®åäœæ¹æ³ãç解ãã ã«ã¯ã 〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ã«ãã ã ã ㌠ã éä¿¡ã® åäœæ¹æ³ãç解ãã ã ãš ãéèŠã§ãã æ¬æžã§ã¯ã èªè
ã« IP ã ã㳠〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠éä¿¡ã®åºç€ç¥èãã ã ã ãš ãåæ ãš ã ãŠããŸãã 以äžã§ã¯ã 〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ã§äœ¿çš ã ãã ã ã ã ã¯ãŒ 㯠㢠ã 㬠ã¹æå®ã®æŠå¿µã« ã€ããŠã é«åºŠãªæŠèŠã説æ ã ãŸãã ã³ ã³ ã 㥠㌠㿠㷠㹠ãã ã®ã ã ãªãã¹ ã ã ã© ã ã ã ã© ãŒã ã®ã€ ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠〠㳠㿠㌠ã 㧠〠ã¹ã¯ã ã©ã ã ã° ããŒãã«ã«äžæ㪠㬠〠〠2 㢠ã 㬠㹠ã 1 〠㚠ã ã° ããŒãã«ã«äžæ㪠㬠〠〠3 㢠ã 㬠㹠ãå°ãª ã ãš ã 1 〠å¿
èŠ ãš ã ãŸãã OSI ã¢ãã«ã§å®çŸ© ã ããŠãã ã ã ã«ã 㬠〠〠2 ã¯ã㌠㿠㪠㳠㯠㬠ã€ã€ ã§ã 㬠ã€ã€ 3 ã¯ã ã ã ã¯ãŒ ã¯
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ããŒã åãšãããã¯ãŒã¯ã¢ãã¬ã¹ ã¢ã ã ã¿ ã®ããŒã ã¯åäžã®ä»®æ³ã ã ã ã¯ãŒ 㯠〠㳠㿠㌠ã 㧠〠㹠㚠ã ãŠæ©èœ ã ã ããŒã å ã ããŠããªãã¢ã ã ã¿ ã®ã ã ã ã¯ãŒ 㯠ãã〠㹠㚠å ã ã ã ã«èŠã ãŸãã ä»®æ³ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ã¯ã åäžã®ã¬ 〠〠2 㢠ã 㬠㹠㚠1 ã€ãŸãã¯è€æ°ã®ã¬ 〠〠3 㢠ã 㬠㹠ãéç¥ ã ãŸãã ããŒã å ã ã© ã€ãã¯ã åæåã®éã«ã ããŒã ãæ§æããç©çã¢ã ã ã¿ ã®ããã ããã ã ããŒã MAC 㢠ã 㬠㹠㚠㪠ã MAC 㢠ã 㬠㹠ã 1 ã€éžæ ã ãŸãã äžè¬çã« ã 㮠㢠ã 㬠ã¹ã¯ã ã ã© ã€ããæåã«åæåãã ã¢ã ã ã¿ ã ã ååŸ ã ããŸãã ããŒã ã管ç ã ãŠã ã ã· ã¹ ãã ã¯ã ARP èŠæ±ãåä¿¡ãã ãš ã ããŒã å
ã®ç©çã¢ã ã ã¿ ã®äžã ã MAC 㢠ã 㬠㹠ã 1 ã€éžæ ã ãŠã ARP å¿ç㮠㜠ãŒã¹ MAC 㢠ã 㬠㹠㚠ã ãŠäœ¿çš ã ãŸãã Windo
11âQLogic ããŒã åãµãŒã ã¹ èŠæš è¡š 11-2 ã¯ããŒã 㿠〠ã ãš ãã ãã®åé¡ã®èŠçŽã瀺 ã ãŠããŸãã è¡š 11-2. å©çšå¯èœãªããŒã åã¿ã€ã ããŒãã³ã°ã®ã¿ã€ã ã¹ã€ãã äŸå a ã¹ã€ããã§å¿
èŠãš ããã LACP ãµ ããŒã è² è·åæ£ ãã§ã€ã«ãªãŒã㌠â â â â â â â â Smart Load Balancing ããã³ ã 㧠ã€ã«ãªãŒ ã㌠( ã㌠ã ãã© ã³ ã¹ ã®ããŒã ã¡ ã³ããŒã¯ 2 ïœ 8) SLB ïŒèªå ã ã© ãŒã« ã ã ã¯ã¯ç¡å¹ïŒ 㪠㳠ã¯éçŽ (802.3ad) â éæäžç¶ ïŒFEC/GECïŒ â â /802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš äŒéã®è² è·ã ã© ã³ ã· ã³ ã°ã¯ã çºä¿¡å
ã ãã³å®å
ã® IP 㢠ã 㬠㹠㚠TCP/UDP ã㌠ã çªå· ãäœ¿çš ã ãŠã ã 㷠㥠ããŒãã«ãäœæãã ã ãš ã« ã ã å®çŸ ã ããŸãã çºä¿¡å
ããã³å®å
ã® IP 㢠ã 㬠㹠㚠TCP/UDP ã㌠ã çªå·ã®çµã¿åãããå ã å Žåã«ã¯ã éåžžå ã ã ã 㷠㥠〠ã³ã ã 㯠ã¹ãäœæ ã ãã ããã ããŒã å
ã®å ã ã㌠ã ãæ ã 瀺ã ã ãš ã«ãª ã ãŸãã ç¹ å®ã®ãœ ã± ã ã ã®ãã¹ãŠã® ã 㬠ãŒã ãæ¬éãã ã ã ã«ã㌠ã ãéžæ ã ããŠã ãå Žåã ã㌠ã MAC 㢠ã 㬠㹠ã§ã¯ãª ã ã ç©çã¢ã ã ã¿ ãŒã®äžæã® MAC 㢠ã 㬠ã¹ã ã ã¬ãŒã ã«å«ã ã ããŸãã ã ããå«ããå¿
èŠãã ãã®ã¯ã IEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš 㯠㩠〠㢠㳠ã ãš ã· ã¹ ãã ãå¥ã®ãµãã ã ã ã«ã ã ã åä¿¡ ã ã© ã 㣠ã 㯠ãã«ãŒ ã¿ ãŒãè¶ã ãªããã°ãª ã ãªãå Žåã ã· ã¹ ãã ã«åã ã åä¿¡ ã ã© ã 㣠ã ã¯ã¯ã㌠ã ãã© ã³ ã¹ ã ããŸã ãã äžé ã ã© ã€ã㧠IP ã ããŒãæ¬éãã ã ã éžæ ã ããç©çã¢ã ã ã¿ ã¯ã ãã¹ãŠã® ã ã© ã 㣠ã 㯠ãæ¬é ã ãŸãã ã«ãŒ ã¿ ãŒã¯ããŒã IP 㢠ã 㬠ã¹ã« ã 㬠ãŒã ãéä¿¡ãã ãš ã ã«ã ARP èŠæ±ã ã ã㌠ã ã 㣠㹠ã ã ãŸã (ARP ã 㣠ã 㷠㥠ã«ãªãå Žå )ã ãµãŒã㌠㜠ã ã ㊠㧠㢠㹠㿠ã 㯠ã¯ããŒã MAC 㢠ã 㬠㹠ãäœ¿çš ã ㊠ARP å¿çãçæ ã ãŸããã äžé ã ã© ã€ãããã® ARP å¿çãä¿®æ£ ã ãŠç¹å®ã®ç©çã¢ã ã ã¿ ãŒã«éä¿¡ ã ã ãã®ã» ã 㷠㧠ã³ã® ã ããŒãç¢ºç« ã ãŸãã ã ãã¯ã ARP ãã«ãŒ ã¿ ãã« ã ã ã ã³ ã«ã§ã¯ãªãããã§ãã ARP ã«ã¯ IP ã ã ã
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ã ã®ããŒã åã¢ãŒ ã ã§ã¯ã äžé ã ã© ã€ãã¯çºä¿¡ ã ã© ã 㣠ã ã¯ã®ã㌠ã ãã© ã³ ã· ã³ã° ãš ã 㧠ã€ã«ãªãŒããŒã®ã¿ãå¶åŸ¡ ã ã åä¿¡ ã ã© ã 㣠ã ã¯ã¯ã¹ 〠ã ãã® ã ã¡ ãŒã ㊠㧠㢠㚠ã㌠ã ㊠㧠㢠ã§å¶åŸ¡ ã ããŸãã Smart Load Balancing ã®å Žåã®ã ã ã«ã QLASP äžé ã ã© ã€ã㯠IP/TCP ã ãã³ UDP ã®çºä¿¡å
ããã³å®å
㢠ã 㬠㹠ãäœ¿çš ã ãŠã ãµãŒããŒã®äŒé ã ã© ã 㣠ã ã¯ã®è² è·ã ã© ã³ ã¹ ãè¡ããŸãã 倧éšåã®ã¹ 〠ã ãã¯ã çºä¿¡å
ã ãã³å®å
MAC 㢠ã 㬠ã¹ã® XOR ã ã 㷠㥠ãå®è£
ã ãŠããŸãã ã¡ã¢ éæäžç¶ã¯ã iSCSI 㪠ã ã㌠ã ã¢ã ã ã¿ ãŒã§ã¯ãµã㌠ã ã ããŠããŸããã ãªã³ã¯éçŽïŒIEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ããŒã ã«å² ã åœãŠ ããã ã 㩠〠ã 㪠ã¢ã ã ã¿ ãã 㣠㹠ãšãŒãã« ã ããå Žåã ããŒã ã¯èª å ã ã© ãŒã«ã ã ã¯ãçºçãã Smart Load Balancing ( ã¹ã㌠ã ã㌠ã ã ã© ã³ ã¹ ) ãã ã³ ã 㧠ã€ã«ãªãŒã㌠ããŒã 㿠〠ã ãš ã ãŠæ©èœ ã ãŸãã ãœãããŠã§ã¢ã³ã³ããŒãã³ã Windows ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ç°å¢ã§ã¯ã ã㌠ã ã³ ã°ã¯ NDIS äžé ã ã© ã€ãã« ã 㣠ãŠå®è£
ã ããŸãã ã 㮠㜠ã ã ㊠㧠㢠㳠ã³ããŒã ã³ ã ã ã ãã㌠ã ã ã© ã€ãã NDIS 㬠〠ã€ã ã ãã³ã ã ã ã³ ã«ã¹ ã¿ ã 㯠ã§åäœ ã ãŠã ã㌠ã ã³ ã°ã¢ãŒãã 㯠ã 㣠ãå¯èœã« ã ãŸã (144 ããŒãžã®å³ 11-2 ãåç
§ )ã ã ãã㌠ã ã ã© ã€ãã¯ãã¹ ã LAN ã³ ã³ ã ã㌠㩠ãçŽæ¥å¶åŸ¡ ã ãŠã éåä¿¡ããã³å² ã 蟌ã¿ã®åŠç㪠ã©ã®æ©èœãæå¹ã« ã ãŸãã äžé ã 㩠〠ã㯠ã ãã㌠ã ã
11âQLogic ããŒã åãµãŒã ã¹ èŠæš è¡š 11-3. QLogic ããŒã åãœãããŠã§ã¢ã³ã³ããŒãã³ã ( ç¶ã ) ãœãããŠã§ã¢ ã³ã³ã㌠ãã³ã äžé ã ã© ã€ã èšå®ãŠãŒã¶ãŒ ã€ã³ã¿ ã ã§ãŒ ã¹ QLogic å QLASP QLogic Control Suite ïŒQCSïŒ ãããã¯ãŒã¯ã¢ããã¿ãŒãŸã㯠ãªãã¬ãŒãã£ã³ã°ã·ã¹ãã ã·ã¹ãã ã¢ãŒ ããã¯ã㣠Windows ãã¡ã€ã«å Windows Server 2008 32 ã ã ã ã 64 ã ã ã qlasp.sys Windows Server 2008 R2 64 ã ã ã qlasp.sys Windows Server 2012ã 2012 R2 64 ã ã ã qlasp.sys Windows Server 2008 â qcs.exe Windows Server 2008 R2 â qcs.exe Windows Server 2012ã 2012 R2 â qcs.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ã¹ã€ããã³ã°ãã 㪠ã㌠㿠ãã ãš ã¯ç°ãª ã ã 㹠〠ã ã ã³ ã° ãã ( ã ã ã«ç°¡åã«èšãã°ã 㹠〠ã ã ) ãäœ¿çš ãã ãš ã 〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ãè€æ°ã®è¡çª ã 㡠〠㳠ã«åã ã ã ãš ã㧠ã ãŸãã 㹠〠ã ãã¯ã 〠ãŒãµã ã ã MAC 㢠ã 㬠ã¹ã ãã«åºã¥ããŠã ãã¹ ã é㧠〠ãŒãµã ã ã ã ã± ã ã ã転éãã圹å²ãæã ã ãŸãã 㹠〠ã ãã«æ¥ç¶ ã ããŠããç©çã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ã¯ã åäºéãŸãã¯å
šäºéã¢ãŒ ã ã§åäœããå Žåãã ã ãŸãã éæäžç¶ ãš 802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ãµããŒããããæ©èœïŒããŒã ã¿ã€ãå¥ïŒ è¡š 11-4 ã¯ã Dell ã§ãµã㌠ã ã ããŠãã ããŒã 㿠〠ãã®æ©èœã®æ¯èŒã瀺 ã ãŠããŸãã ã ã®è¡šãäœ¿çš ã ãŠã 㢠ã 㪠ã±ãŒã· 㧠㳠ã«æé©ãªããŒã 㿠〠ã ãç¢ºèª ã ㊠ã ã ã ãã ããŒã å 㜠ã ã ㊠㧠ã¢ã¯ã 1 ã€ã®ããŒã ã§æ倧 8 ã㌠ã ã 㟠ã 1 ã€ã®ã· ã¹ ãã ã§æ倧 16 ã㌠ã ããµã㌠ã ã ãŸãã ã ã ã ã®ããŒã ã¯ã ãµã㌠ã 察象ã®ããŒã å 㿠〠ã ãä»»æã«çµã¿ åããã ã ãš ã㧠ã ãŸããã åããŒã ã¯å¥ã
ã®ã ã ã ã¯ãŒ 㯠ãŸãã¯ãµãã ã ã äžã«ã ã å¿
èŠãã ã ãŸãã è¡š 11-4. ããŒã ã¿ã€ãã®æ¯èŒ ããŒã ã¿ã€ã ãã©ã«ã ãã¬ã©ã³ã¹ è² è·åæ£ ã¹ã€ããäŸåå éçäžç¶ ã¹ã€ããéäŸåååç ãªã³ã¯éçŽ ïŒIEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš è¡š 11-4. ããŒã ã¿ã€ãã®æ¯èŒ ( ç¶ã ) ããŒã ã¿ã€ã ãã©ã«ã ãã¬ã©ã³ã¹ è² è·åæ£ ã¹ã€ããäŸåå éçäžç¶ ã¹ã€ããéäŸåååç ãªã³ã¯éçŽ ïŒIEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ èŠæš ããŒã ã¿ã€ãã®éžæ 次ã®ã ã㌠ã 㣠㌠ã ã§ã¯ã 㬠〠〠2 ã®ããŒã åãèšç»ãã ãš ãã®æææ±ºå® ã ããŒã瀺 ã ãŸãã ããŒã åãè¡ ã 第 1 ã®çç±ã¯ã ã ã ã ã¯ãŒ ã¯åž¯åå¹
ã®å¢å ãš ã ã©ã« ã ã 㬠㩠㳠㹠ã®åäžãå¿
èŠã§ã ã ã ãš ã§ãã ããŒã åã« ã ã ã ã ã®äž¡æ¹ã®èŠä»¶ãæºãããã㮠㪠㳠㯠éçŽ ãš ã ã© ã« ã ã 㬠㩠㳠ã¹ãæäŸ ã ããŸãã åªå
ãã ããŒã åã¯ã 以äžã®é åºã§éžæã ãå¿
èŠãã ã ãŸãã ï® ç¬¬ 1 ã®éžæ ïŒ ãª ã³ ã¯ éçŽ ï® ç¬¬ 2 ã®éžæ ïŒ éæäžç¶ ï® ç¬¬ 3 ã®éžæ ïŒ SLBã é管ç察象㹠〠ã ã ãŸãã¯æåã® 2 ã€ã®éžæè¢ããµã㌠ã ã ãŠããªã㹠〠ã ã ã䜿çšããå Žåã 㹠〠ã ãã® ã ã© ãŒã« ã ã 㬠㩠㳠ã¹ãå¿
èŠãªå Ž åã¯ã SLB ãå¯äžã®éžæè¢ã§ãã 141 BC0054508-04 J
11âQLogic ããŒã åãµãŒã ã¹ èŠæš å³ 11-1 ã«ã ããŒã 㿠〠ã ã決å®ãã ããã® ã ããŒã 㣠㌠ã ã瀺 ã ãŸãã å³ 11-1.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ ããŒã åã®ä»çµã¿ æ¬é
ã§ã¯ã ããŒã åã®ä»çµã¿ã«é¢ãã次ã®æ
å ±ã«ã€ããŠèª¬æ ã ãŸãã ï® ã¢ãŒãã 㯠ã ã£ ï® ããŒã 㿠〠ã ï® åããŒã 㿠〠ã ãš é¢é£ããåçš®æ©èœã®å±æ§ ï® åããŒã 㿠〠ã ã§ãµã㌠ã ã ããŠããé床 143 BC0054508-04 J
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ ã¢ãŒããã¯ã㣠QLASP ã¯ã NDIS äžé ã ã© ã€ã ãš ã ãŠå®è£
ã ããŸã ïŒå³ 11-2 ãåç
§ïŒã TCP/IP ã IPX 㪠ã©ã®ã ã ã ã³ ã« ã¹ ã¿ ã ã¯ã®äžã§åäœ ã ã ä»®æ³ã¢ã ã ã¿ ãš ã ãŠè¡šç€º ã ããŸãã ã ã® ä»®æ³ã¢ã ã ã¿ ã¯ã ããŒã ã§æåã«åæå ã ããã㌠ã ã® MAC 㢠ã 㬠㹠ãç¶æ¿ ã ãŸãã 㬠〠〠3 㢠ã 㬠㹠ã ã ä»®æ³ã¢ã ã ã¿ ã«å¯Ÿ ã ãŠèšå®ããå¿
èŠãã ã ãŸãã QLASP ã®äž»èŠ æ©èœã¯ã ããŒã åãã ã ãš ãéžæ ã ããã· ã¹ ãã ã«å ã ä»ã ã ããŠããç©çã¢ã ã 㿠㌠éã§ã 〠ã³ã㊠㳠ã ã ã© ã 㣠ã 㯠ïŒSLB ã®å ŽåïŒ ãš ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ïŒãã¹ ãŠã®ããŒã åã¢ãŒ ã ã®å ŽåïŒ ã®ã ã© ã³ ã¹ ã ãš ã ã ãš ã§ãã 〠ã³ã㊠㳠ã ã¢ã«ãŽ 㪠ãºã ãš ã¢ãŠ ã ã㊠㳠ã ã¢ã«ãŽ 㪠ãºã ã¯çžäºã«ç¬ç« ã ã çŽäº€ ã ãŠããŸãã ç¹å®ã®ã» ã ã· ã§
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ ã¢ãŠãããŠã³ããã©ãã£ãã¯ãã㌠QLogic äžé ã ã© ã€ãã¯ã ãã¹ãŠã®ããŒã åã¢ãŒ ã ã®ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ã ããŒã管ç ã ãŸãã ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ã®å Žåã ãã¹ãŠã®ãã± ã ã ã¯æåã« ã ããŒã«åé¡ ã ãã éžæ ã ããç©çã¢ã ã ã¿ ã«é
å ã ããŠäŒé ã ããŸãã ã ããŒåé¡ã§ã¯ã æ¢ç¥ã®ã ã ã ã³ ã« ã 㣠ãŒã« ã ã«å¯Ÿ ã ãŠå¹ççãªã ã ã· ã¥èšç®ãè¡ãããŸãã çµæã®ã ã ã· ã¥å€ãäœ¿çš ã ãŠã ã¢ãŠ ã ã㊠㳠ã ã ããŒã ã 㷠㥠ããŒãã«ã« 〠ã³ã ã 㯠ã¹ãäœæ ã ã ãŸãã éžæ ã ãã¢ãŠ ã ã㊠㳠ã ã ããŒã ã 㷠㥠㚠㳠ã 㪠ã«ã¯ã ã ã® ã ããŒã®äŒéãè¡ ã éžææžã¿ã®ç©çã¢ã ã ã¿ ãŒã®ã€ ã³ã ã 㯠ã¹ãå«ãŸããŠããŸãã ãã± ã ã 㮠㜠ãŒã¹ MAC 㢠ã 㬠ã¹ã¯ã éžæ ã ãç©çã¢ã ã ã¿ ã® MAC 㢠ã 㬠ã¹ã«å€æŽ ã ããŸãã å€æŽ ã ããã ã±
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ 〠ã³ã㊠㳠ã IP ã㌠㿠㰠㩠ã ãå°çãã ãš ã IP ã㌠㿠㰠㩠ã ã®ãœ ãŒã¹ IP 㢠ã 㬠㹠ã ã ã 㷠㥠ãã ã ãš ã« ã 㣠ãŠé©å㪠〠ã³ã㊠㳠ã ã ã㌠ã ã ã ãš ã³ ã 㪠ãæ€çŽ¢ ã ããŸãã éžæ ã ããš ã³ ã 㪠ã«æ ŒçŽ ã ããŠãã 2 ã€ã®çµ±èšã« ㊠㳠㿠ãæŽæ° ã ããŸãã ã ã ãã®ã« ㊠㳠㿠ã¯ã ã㌠ã ãã© ã³ ã· ã³ã° ãš ã³ ãž ã³ ã« ã 㣠㊠ã¢ãŠ ã ã㊠㳠ã 㫠㊠㳠㿠㚠å ã æ¹æ³ã§ å®æçã«äœ¿çš ã ãã ã ããŒãç©çã¢ã ã ã¿ ã«åå² ã åœãŠ ã ããŸãã 〠ã³ã㊠㳠ã 㳠㌠ã ãã¹ã§ã¯ã 〠ã³ã㊠㳠ã ã ã㌠ã ã ã ã ã 㷠㥠ããŒãã«ãåæ 㢠㯠ã»ã¹ ãèš±å¯ãã ã ã ã« ã èšèš ã ããŠããŸãã 〠ã³ã㊠㳠ã ã ã㌠㚠㳠ã 㪠㮠㪠㳠㯠㪠㹠ã ã¯ã ARP ãã± ã ã ã®åŠçæ ãš å®æç㪠ã㌠ã ã ã© ã³ ã· ã³ ã°æã«ã®ã¿åç
§ ã ã
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ ãŸãã¯ã ã¹ ã 㪠ãŒã ã¯æ¬¡ã®ã ã ã«ãª ã ãŸãã IGMP ------> PhysAdapter1 ------> 10.0.0.1 ICMP ------> PhysAdapter1 ------> 10.0.0.1 TCP ------> PhysAdapter2 ------> 10.0.0.1 UDP ------> PhysAdatper3 ------> 10.0.0.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ QLASP äžé ã ã© ã€ãã¯ã ããŒã å
ã®ç©çã㌠ã 㧠㪠㳠㯠ã ã¹ ãç¶ç¶çã«ç£èŠ ã ãŸãã ããããã®ã㌠ã 㧠㪠㳠㯠ã ã¹ãçºç ã ãå Žåã ã ã© ã 㣠ã 㯠ã¯ããŒã å
ã®ä»ã®ã㌠ã ã«èªåçã«è»¢é ã ããŸãã SLB ããŒã åã¢ãŒ ã ã¯ã ç°ãª ã 㹠〠ã ããå ã ç©çã ã ã ã¯ãŒ 㯠ãŸãã¯ã ã㌠ã ã 㣠㹠ã ã 㡠〠ã³äžã«ããã°ã ãã ãã®ã¹ 〠ã ãéã®ããŒã åã èš±å¯ãã ã ãš ã« ã ã 㹠〠ã ãã® ã ã© ã« ã ã 㬠㩠㳠㹠ããµã㌠ã ã ãŸãã ãããã¯ãŒã¯éä¿¡ SLB ã®ããŒå±æ§ã«ã¯ã 以äžãå«ãŸããŸãã ï® ã 㧠ã€ã«ãªãŒã㌠㡠㫠ããºã - 㪠㳠㯠ã ã¹æ€åºã ï® è² è·ã ã© ã³ ã· ã³ ã°ã¢ã«ãŽ 㪠ãºã - 〠ã³ã㊠㳠ã ããã³ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ã¯ã 㬠〠〠4 ã ããŒã«åºã¥ããŠã QLogic ç¬èªã® ã¡ ã« ããºã ã§ãã© ã³ ã¹ ã ãš ã ãŸãã ï® MAC
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ ã ã®ã¢ãŒ ã ã§ã¯ã ããŒã å
ã®ãã¹ãŠã®ã¢ãã ã¿ ãå ã MAC 㢠ã 㬠ã¹ã®åä¿¡ãã± ã ã ã« èšå® ã ããŸãã ã ã© ã³ãã³ ã°ã¯ã¬ ã€ã€ 2 㢠ã 㬠㹠ã§åäœ ã ã 〠ã³ã㊠㳠ã / ã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã ã¯ã®ã㌠ã ãã© ã³ ã· ã³ ã° ãš ã 㧠ã€ã«ãªãŒããŒããµã㌠ã ã ãŠããŸãã QLASP ã ã© ã€ãã¯åè¿°ã®ã¬ 〠〠4 ã ã ã ã³ ã«ãäœ¿çš ã ㊠ã¢ãŠ ã ã㊠㳠ã ãã± ã ã ã®è² è·ãã© ã³ ã· ã³ ã°ã¹ããŒã ã決å®ããã®ã«å¯Ÿ ã ã ããŒã 㮠㪠㳠㯠ã㌠ã ããŒã¯ã€ ã³ã㊠㳠ã ãã± ã ã ã®è² è·ã ã© ã³ ã· ã³ ã°ã¹ããŒã ãæ±ºå® ã ãŸãã æ¥ç¶ ã ããŠãã 㹠〠ã ãã¯ã ã ã®åäœã¢ãŒ ã ã«é© ã ã ã ã© ã³ãã³ ã° ã¹ããŒã ããµã㌠ã ããå¿
èŠãã ã ãŸãã QLASP 㚠㹠〠ã ãã¯ã© ã¡ ã ã ããããã®ã㌠ã 㧠㪠㳠㯠ã ã¹ ã ç¶ç¶çã«ç£èŠ ã ãŸãã ããããã®ã㌠ã 㧠㪠㳠ã¯
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ åçäžç¶ïŒIEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ LiveLink LiveLink 㯠QLASP ã®æ©èœã§ã ã ã ããŒã 㿠〠ãã Smart Load Balancing ïŒSLBïŒ ã ãã³ SLB ïŒèªå ã ã© ãŒã«ã ã 㯠ã¯ç¡å¹ïŒ ã®å Žåã«äœ¿çšã§ ã ãŸãã LiveLink ã¯ã 㹠〠ã ãã§çºç ã ã 㪠㳠㯠ã ã¹ ãæ€åº ã ã 㪠㳠ã¯ãæå¹ã«ãª 㣠ãŠã ã ããŒã ã¡ ã³ããŒã®ã¿ ã® ã ã© ã 㣠ã 㯠ãã«ãŒã 㣠㳠㰠ã ãŸãã ã ã®æ©èœã¯ã ããŒã å 㜠ã ã ㊠㧠㢠㧠ã䜿çšã ã ã ãš ã㧠ã ãŸãã ããŒã å 㜠ã ã ㊠㧠ã¢ã¯ã åããŒã ã¡ ã³ããŒã ã 㪠㳠㯠ãã± ã ã ã çºè¡ ã ãŠã 1 ã€ãŸãã¯è€æ°ã®ç¹å®ã ã ã ã¯ãŒ 㯠ãã〠ã¹ã®ã ããŒã ïŒæ€æ»ïŒ ãè¡ããŸãã ã ããŒã察象ã¯ã 㪠㳠㯠ãã± ã ã ãåä¿¡ãã ãš å¿çãè¿ ã ãŸãã ããŒã ã¡ ã³ããŒãäžå® æéå
ã«å¿çãæ€åº ã ãªãå Žåã 㪠㳠ã¯ã¯æ倱 ã ãŠã ã ã ããŒã å 㜠ã ã ㊠㧠ã¢ã¯ã
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã®ä»çµã¿ è¡š 11-5. ããŒã åå±æ§ ( ç¶ã ) æ©èœ å±æ§ ã 㧠ã€ã«ãªãŒããŒæé 500 ã 㪠ç§æªæº ã ã© ãŒã«ã ã ã¯æé 1.5 ç§ ïŒæŠç®ïŒ a MAC 㢠ã 㬠㹠ç°ãª ã Broadcom 以å€ã®è£œåãäœ¿çš ã ãããŒã å ã¯ã éæäžç¶ ãŠãŒã¶ãŒ 〠㳠㿠ã 㧠ãŒã¹ QLogic Control Suite ïŒQCSïŒ ããŒã æ° æå€§æ° 16 ããŒã ã ãš ã®ã¢ãã ã¿ ãŒæ° æå€§æ° 16 åç眮æ ã¯ã åçè¿œå ã¯ã åçåé€ ã¯ã 㪠㳠ã¯é床ãµã㌠ã ã 㟠ã 㟠ãªé床 b ã ã¬ãŒã ã ã ã ã³ ã« ãã¹ãŠ 〠ã³ããŠã³ ã ãã± ã ã 管ç ã¹ã€ ãã ã¢ãŠ ã ããŠã³ ã ãã± ã ã 管ç QLASP ã 㧠ã€ã«ãªãŒã㌠〠ãã³ ã 㪠㳠㯠ã ã¹ã®ã¿ ã 㧠ã€ã«ãªãŒããŒæé 500 ã 㪠ç§æªæº ã ã© ãŒã«ã ã ã¯æé 1.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã å ãš ãã®ä»ã®è©³çŽ°ãªã ã ã ã¯ãŒ 㯠ã ããã 㣠衚 11-5. ããŒã åå±æ§ ( ç¶ã ) æ©èœ å±æ§ 㪠㳠ã¯é床ãµã㌠ã ã 㟠ã 㟠ãªé床 ã ã¬ãŒã ã ã ã ã³ ã« ãã¹ãŠ 〠ã³ããŠã³ ã ãã± ã ã 管ç ã¹ã€ ãã ã¢ãŠ ã ããŠã³ ã ãã± ã ã 管ç QLASP ã 㧠ã€ã«ãªãŒã㌠〠ãã³ ã 㪠㳠㯠ã ã¹ã®ã¿ ã 㧠ã€ã«ãªãŒããŒæé 500 ã 㪠ç§æªæº ã ã© ãŒã«ã ã ã¯æé 1.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã å ãš ãã®ä»ã®è©³çŽ°ãªã ã ã ã¯ãŒ 㯠ã ããã ã£ ï® ãž ã£ ã³ã ã ã¬ãŒã ï® IEEE 802.1Q VLAN ï® Wake on LAN ï® ã 㪠ã㌠ã å®è¡ç°å¢ ããŒã ã®äœæã ããŒã ã¡ ã³ããŒã®è¿œå ãåé€ã ãŸãã¯ããŒã ã¡ ã³ããŒã®è©³çŽ°èšå®ã®å€æŽ ãè¡ ã åã«ã åããŒã ã¡ ã³ããŒãå ã ã ã ã«æ§æ ã ããŠã ã ã ãš ãç¢ºèª ã ㊠ã ã ã ãã 確èªããèšå® ãš ã ãŠã VLAN ã ãã³ QoS ãã± ã ã ã¿ ã®ã³ ã°ã 㞠㣠ã³ã ã ã¬ãŒã ã ãã ã³å皮㪠ã ã㌠ã ãã ã ãŸãã 詳现㪠ã¢ãã ã¿ ã ããã 㣠㚠ããŒã åãµã㌠ã ã è¡š 11-7 ã«ç€º ã ãŸãã è¡š 11-7. 詳现ãªã¢ããã¿ãŒããããã£ãšããŒã åãµããŒã ããŒã åä»®æ³ã¢ããã¿ã« ãããµããŒã ã¢ããã¿ãŒãããã㣠Checksum Offload ïŒã 㧠ã 㯠ãµã 㪠ã ã¯ã ã㌠ã ïŒ IEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã å ãš ãã®ä»ã®è©³çŽ°ãªã ã ã ã¯ãŒ 㯠ã ããã 㣠ã¡ã¢ ããŒã ãã ããã 㣠ããµã㌠ã ãã ããã«ã ããŒã ã®ãã¹ãŠã®ã¢ã ã ã¿ ã¯ã è¡š 11-7 㫠㪠㹠ã ã ããŠã ã ã ããã 㣠ããµã㌠ã ããå¿
èŠãã ã ãŸãã ãã§ãã¯ãµã ãªãããŒã ã 㧠ã 㯠ãµã 㪠ã ã㌠ã 㯠QLogic ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒã®ã ããã 㣠ã§ã ã ã éå ä¿¡ ã ã© ã 㣠ã 㯠㮠TCP/IP/UDP ã 㧠ã 㯠ãµã ã ãã¹ ã CPU ã§ã¯ãª ã ã¢ã ã ã¿ ãŒã㌠ã ㊠㧠㢠ã§èšç®ã§ ã ã ã ã ã« ã ãŸãã ã ã© ã 㣠ã 㯠éãå€ãç¶æ³ã§ã¯ã ã ãã« ã ã ã ã· ã¹ ãã ã¯ãã¹ ã CPU ãã 㧠ã 㯠ãµã ã®èšç®ãåŒ·å¶ ã ããå Žåã ã ãå¹ççã«æ¥ç¶ãåŠç 㧠ã ãŸãã ã ã®ã ããã 㣠ã¯æ¬è³ªçã«ã㌠ã ㊠㧠㢠ã ããã 㣠ã§ã ã ã 㜠ã ã ㊠㧠ã¢ã® ã¿ã®å®è£
ã§ã¯å©ç¹ãçãããŸããã Checksum Offload (
11âQLogic ããŒã åãµãŒã ã¹ ããŒã å ãš ãã®ä»ã®è©³çŽ°ãªã ã ã ã¯ãŒ 㯠ã ããã 㣠IEEE 802.1Q VLAN 1998 幎ã«ã IEEE 㯠802.3ac æšæºãæ¿èª ã 㟠ã ãã ã ã®æšæºã¯ã IEEE 802.1Q ä»æ§ ã§æå® ã ããŠããã Ethernet ã ã ã ã¯ãŒ ã¯äžã§ã® Virtual Bridged Local Area Network (VLAN) ã¿ ã®ã³ ã° ããµã㌠ã ãã ã ã¬ãŒã 圢åŒæ¡åŒµãå®çŸ© ã ãŠããŸãã VLAN ã ã ã ã³ ã«ã§ã¯ã 〠ãŒãµã ã ã ã 㬠ãŒã ã«ãã® ã 㬠ãŒã ãå±ãã VAN ãèå¥ãã ã¿ ã° ãæ¿å
¥ã§ ã ãŸãã çŸåšã¯ã 4 ã〠ã ã® VLAN ã¿ ã°ã Ethernet ã 㬠ãŒã 㮠㜠ãŒã¹ MAC 㢠ã ã¬ ã¹ ãš é· ã / 㿠〠ã ã 㣠ãŒã« ã ã®éã«æ¿å
¥ ã ããŸãã VLAN ã¿ ã°ã®æåã® 2 ã〠ã 㯠IEEE 802.
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
ããªããŒãå®è¡ç°å¢ ã 㪠ã㌠ã å®è¡ç°å¢ ïŒPXEïŒ ã§ã¯ã ã ã ã ã¯ãŒ 㯠ãäœ¿çš ã ãŠã ã· ã¹ ãã ã ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã 〠㡠ãŒãžã ãèµ·å㧠ã ãŸãã å®çŸ©äžã PXE ã¯ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã ã㌠ã ããåã«åŒã³åº ã ãã ããã QLASP äžé ã ã© ã€ããããŒã ã ã㌠ã ã ãŠæå¹ã« ããæ©äŒã¯ã ã ãŸããã ã ãã 㣠ãŠã ãªã 㬠ãŒã 㣠㳠㰠㷠㹠ãã ã®ã㌠ã æã«ããŒã ã« å
¥ãã ããç©çã¢ã ã ã¿ ã¯ã PXE 㯠㩠〠㢠㳠ã ãš ã ãŠäœ¿çšã§ ã ãŸããã ããŒã åæ©èœã® ã¢ã ã 㿠㯠PXE 㯠㩠〠㢠㳠ã ãš ã ãŠãµã㌠ã ã ããŸããã ããŒã å ã ããã¢ã ã 㿠㌠㯠PXE 㯠㩠〠㢠㳠ã ãš ã ãŠäœ¿çšã§ ã ãŸãããã åçãã¹ ã å¶åŸ¡ã ã ã ã³ ã« ïŒDHCPïŒ ãš ã 㪠ã ã¢ã« ã ã¡ ã€ã«è»¢éã ã ã ã³ ã« ïŒTFTPïŒ ãäœ¿çš ã ãŠ
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
è€æ°ã®ã¹ã€ããã«ãŸãããããŒã å SLB ã®ããŒã åã¯ã è€æ°ã®ã¹ 〠ã ãã«ãŸãã 㣠ãŠèšå®ã§ ã ãŸãã ãã ã ã 㹠〠ã ãå士 ãæ¥ç¶ããå¿
èŠãã ã ãŸãã éæäžç¶ 㚠㪠㳠ã¯éçŽã¯ã è€æ°ã®ã¹ 〠ã ãã«ãŸãã 㣠ãŠå äœã§ ã ãŸããã ãã®çç±ã¯ã ã ã ã ã®å®è£
ã§ã¯ã ããŒã ã«å«ãŸãããã¹ãŠã®ç©çã¢ã ã ã¿ ã§å ã 〠ãŒãµã ã ã MAC 㢠ã 㬠㹠ã䜿çšããå¿
èŠãã ã ããã§ãã SLB ã 㪠㳠㯠ã ã¹ ãæ€åºã§ ã ãã®ã¯ã ããŒã ã«å«ãŸãã ã㌠ã éã®æ¥ç¶ãã çŽæ¥ã® 㪠㳠㯠ã㌠ã ã㌠㚠ã®æ¥ç¶ã«é ã ãã ãš ã ã ç¹ã«æ³šæãã ã ãš ãéèŠã§ãã SLB ã«ã¯ã 㹠〠ã ãã§ç ã ã ä»ã®ã㌠ã ㊠㧠ã¢é害ã«å¯Ÿå¿ããæ©èœã㪠ã ã ä»ã®ã㌠ã 㮠㪠㳠㯠ã ã¹ ãæ€åºã§ ã ãŸã ãã ã¹ã€ãããªã³ã¯ã®ãã©ãŒã«ããã¬ã©ã³ã¹ æ¬é
ã®å³ã§ã¯ã ã ã© ãŒã« ã ã 㬠㩠㳠ã¹å¯Ÿå¿ã®ã¹ 〠ã ãæ§æ
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
å³ 11-3.
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
å³ 11-4.
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
å³ 11-5 ã¯ã Top Switch ã®ã㌠ã 4 ã§ã±ãŒãã«ãå€ããå Žåã® ã 㧠ã€ã«ãªãŒã㌠〠ã ã³ ã ãè¡š ã ãŠããŸãã æ¥ç¶ãåæ ã ããã«ã ãã¹ãŠã®ã¹ ããŒã· 㧠ã³ãçžäºã« ping ãé å信㧠ã ãã®ã§ã ã ã®ã€ ãã³ ã ã¯é©å㪠ã 㧠ã€ã«ãªãŒããŒã§ãã å³ 11-5.
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
ã¹ããã³ã°ããªãŒã¢ã«ãŽãªãºã 〠ãŒãµã ã ã ã ã ã ã¯ãŒ 㯠ã®å Žåã 2 ã€ã®ã 㪠ã ãžéãŸãã¯ã¹ 〠ã ãéã§ã¯ã 㢠㯠ã 㣠ã ãªãã¹ã 1 ã€ã ãååš ã ãŸãã 㹠〠ã ãéã«ã¢ 㯠ã 㣠ã ãªãã¹ãè€æ°ååš ã ãŠãã ãš ã ã ã ã ã¯ãŒ ã¯å
ã«ã«ãŒããç ã ãå¯èœæ§ãã ã ãŸãã ã«ãŒããçºçãã ãš ã äžéšã® 㹠〠ã ãã¯ã 㹠〠ã ãã®äž¡åŽã§ã¹ ããŒã· 㧠㳠ãèªèãã ã ã ã«ãª ã ãŸãã ã ã®ç¶æ³ã§ã¯ã 転éã¢ã«ãŽ 㪠ãºã ãæ£åžžã«æ©èœã§ ããã éè€ ã 㬠ãŒã ã転é ã ããå¯èœæ§ãã ã ãŸãã ã¹ãã ã³ ã° ã 㪠ãŒã¢ã«ãŽ 㪠ãºã ã§ã¯ã æ¡åŒµã ã ã ã¯ãŒ 㯠å
ã®å
šã¹ 〠ã ãã«ãŸããã ã 㪠ãŒãå®çŸ© ã ãŠã ç¹å®ã®åé·ã㌠㿠ãã¹ ã匷å¶çã«ã¹ ã¿ ã³ã〠ïŒã ã ã ã¯ïŒ ç¶æ
ã«å ã æ¿ã ã ã ãš ã§ã ãã¹ã®åé·æ§ãå®çŸ ã ãŸãã ã ã ã ã¯ãŒ ã¯å
ã®ã¹ 〠ã ãã¯ã ãã¹ã®èå¥ ã«äœ¿çšãã
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
æ¬é
ã¯ä»¥äžã®é
ç®ã®è©³çŽ°ã説æ ã ãŸãã ï® ã ã ã ãžãŒå€æŽéç¥ (TCN) ï® Port Fast ã ãã³ Edge Port ããããžãŒå€æŽéç¥ (TCN) ã 㪠ã ãž ãŸãã¯ã¹ 〠ã ãã¯ã ç¹å®ã®ã㌠ã ã§åä¿¡ ã ã 㜠ãŒã¹ MAC 㢠ã 㬠ã¹ã ãã MAC 㢠ã 㬠㹠㚠ã㌠ã çªå·ã®è»¢éããŒãã«ãäœæ ã ãŸãã ã ã®ããŒãã«ã¯ã ãã¹ãŠã®ã㌠ã ã« ã ã¬ãŒã ãé
ä¿¡ããã®ã§ã¯ãª ã ã ç¹å®ã®ã㌠ã ã« ã 㬠ãŒã ã転éãã ããã«å©çš ã 㟠ãã ããŒãã« ãš ã³ ã 㪠ã®æ倧ã®æ ŒçŽæéã¯ã äžè¬çã« 5 åã§ãã ãã¹ ã 㧠㢠㯠ã 㣠ã ã 㣠ã 5 åéãªã ãš ã ãš ã³ ã 㪠ã¯ããŒãã«ã ãåé€ ã ããŸãã ãš ã³ ã 㪠ã®æ ŒçŽæéãç ã ãã ãš ã å¹æãã ãå Žå ã ã ã ãŸãã ã ãš ãã°ã 転é 㪠㳠㯠ãã ã ã ã¯ç¶æ
ã«ãª 㣠ã ãš ã ã«ã ç°ãª ã 㪠㳠㯠ã ã ã ã ã¯ç¶æ
ã ã
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
ï® ã¹ ã€ ã ãã¯ã ã㌠ã ã®ã¢ ã ã ãŸãã¯ã㊠ã³ã® 㿠〠ã ã³ ã°ã§ã¯ TCN ãçæ ã ãŸã ãã ã¬ã€ã€ 3 ã«ãŒãã£ã³ã°ããã³ã¹ã€ããã³ã° ããŒã å ã ãã㌠ã ãæ¥ç¶ãã 㹠〠ã ãã¯ã 㬠ã€ã€ 3 㹠〠ã ã ãŸãã¯ã«ãŒ ã¿ ãŒã§ã ãå¿
èŠãã ã ãŸãã ããŒã å
ã®ã㌠ã ã¯ã å ã ã ã ã ã¯ãŒ 㯠ã«å±ãå¿
èŠãã ã ãŸãã ããã«ããããŒã åïŒãã©ãã«ã·ã¥ãŒãã£ã³ã°ã®ç®çã®ã¿ïŒ 10 ããã³ 100 ãã ã§ã¯ã SLB ã®ããŒã åæ©èœã䜿çšã§ ã ãŸããã 㹠〠ã ãã㌠ã ã® ã 㩠㌠㪠㳠ã°ã䜿çšã§ ã ãªã ãš ã ã«ã ã ã ã ã¯ãŒ 㯠ã¢ã ã© ã€ã¶ã«æ¥ç¶ããå Žå㪠ã©ã ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã®ç®çã®ã¿ã«éå®ãã ã ãš ã ãå§ã ã ãŸãã ããã®ããŒã åã«é¢ããæ
å ±ã«ã¯ä»¥äžãå«ãŸããŸãã ï® ããŒã åã ã ã ã¯ãŒ 㯠æ§æã§ã®ããã®å©çš ï® SLB ããŒã ï® åäžããã«æ¥ç¶ ã ãã SL
11âQLogic ããŒã åãµãŒã ã¹ å
šè¬çãªã ã ã ã¯ãŒ 㯠ã«é¢ããèæ
®äºé
åäžããã«æ¥ç¶ããã SLB ããŒã å³ 11-6 ã®ã ã ã«æ§æ ã ãã SLB ããŒã ã§ã¯ã ã ã©ã« ã ã 㬠㩠㳠ã¹ã®å±æ§ãç¶æ ã ã㟠ãã ã© ã¡ ããã®ãµãŒããŒæ¥ç¶ãåæ ã ããå Žå㧠ãã ã ã ã ã¯ãŒ ã¯æ©èœã¯ãã®ãŸ ãŸç¶æ ã ããŸãã 㯠㩠〠㢠㳠ã ãããã«çŽæ¥æ¥ç¶ãã ã ãš ã¯ã§ ã ãŸãããã ã ã© ãŒã« ã ã 㬠㩠㳠ã¹ã¯ç¶æ ã ããŸãã ãã ã ã ã ã®å Žåã ãµãŒããŒã®ã ã ã© ãŒã ã³ ã¹ã¯äœäž ã ãŸãã å³ 11-6. åäžããã«æ¥ç¶ãããããŒã éæäžç¶ãšåçäžç¶ïŒFEC/GEC/IEEE 802.3adïŒ FECã GEC ãš IEEE 802.
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
ã¢ããªã±ãŒã·ã§ã³ã«é¢ããèæ
®äºé
㢠ã 㪠ã±ãŒã· 㧠㳠ã«é¢ããèæ
®äºé
ã§ã¯ä»¥äžã説æ ã ãŸãã ï® ããŒã å ãš ã¯ ã© ã¹ ã¿ ãª ã³ ã° ï® ããŒã å ãš ã ã ã ã¯ãŒ ã¯ã ã 㯠㢠ã ã ããŒã åãšã¯ã©ã¹ã¿ãªã³ã° ããŒã å 㚠㯠㩠㹠㿠㪠㳠ã°ã®æ
å ±ã«ã¯ä»¥äžãå«ãŸããŸãã ï® Microsoft 㯠㩠㹠㿠㜠ã ã ãŠ ã§ ã¢ ï® é«æ§èœ ã³ ã³ ã 㥠ãŒã ã£ ã³ ã° ã¯ ã© ã¹ ã¿ ï® Oracle Microsoft ã¯ã©ã¹ã¿ãœãããŠã§ã¢ Dell ãµãŒã㌠㯠㩠㹠㿠㜠㪠㥠ãŒã· 㧠ã³ã¯ã Microsoft Cluster Services ïŒMSCSïŒ ãš PowerVault⢠SCSIã ãŸã㯠Dell ã ãã³ EMC ã®ã ã¡ ã€ããŒã 㣠ãã«ããŒã¹ã®ã¹ ã 㬠ãŒãžã Dell ãµãŒããŒã ã¹ ã ã¬ãŒãž ã¢ã ã ã¿ ãŒã ã¹ ã 㬠ãŒãž 㹠〠ã ãã ã ã ã ã¯ãŒ 㯠㢠ã ã ã¿ ãŒãçµ±å ã ãŠã é«å¯
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
å³ 11-7 ã¯ã 2 ã ㌠ã ã® ã ã¡ ã€ããŒã 㣠ã㫠㯠㩠㹠㿠ã§ã ã ã 㯠㩠㹠㿠ã ㌠ã ãã ã 3 ã€ã®ã ã ã ã¯ãŒ 㯠〠㳠㿠ã 㧠ãŒã¹ãã ã ãŸãã 㯠㩠㹠㿠ã ㌠ã ã®æ§æã¯ã 1 ã€ã®ã 㩠〠ã㌠ã ãš ã 2 ã€ã®ãã 㪠ã 㯠㚠㪠㣠ãŠããŸãã å ã ㌠ã ã§ã¯ã 2 ã€ã®ãã 㪠ã 㯠ã¢ã ã ã¿ ãããŒã å ã ãã ã 㩠〠ã㌠ã ã¢ã ã ã¿ ã¯ããŒã ã«å«ãŸããŠããŸããã å ã 㹠〠ã ã å
ã ãŸã㯠2 ã€ã®ã¹ 〠ã ãéã§ã ããŒã åããµã㌠ã ã ããŸãã 169 ããŒãžã®å³ 11-8 ã¯ã ã ã®æ§æã§èšå® ã ãå ã 2 ã ㌠ã ã ã¡ ã€ããŒã 㣠ã㫠㯠㩠㹠㿠ã§ãã å³ 11-7.
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
é«æ§èœã³ã³ãã¥ãŒãã£ã³ã°ã¯ã©ã¹ã¿ ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã¯ã äžè¬çã«ã é«æ§èœ ã³ ã³ ã 㥠ãŒã 㣠㳠㰠㯠㩠㹠㿠ïŒHPCCïŒ ã¢ ã 㪠ã±ãŒã· 㧠㳠ã§ä»¥äžã® 3 ã€ã®ç®çã§äœ¿çš ã ããŸãã ï® ããã»ã¹ééä¿¡ ïŒIPCïŒ ïŒ åŸ
ã¡æéã®å°ãªãã åºåž¯åå¹
ã®çžäºæ¥ç¶ãå¿
èŠã§ã¯ãªã 㢠ã 㪠ã±ãŒã· 㧠ã³ã®å Žå ïŒMyrinetâ¢ã InfiniBand® 㪠ã©ïŒïŒã ã³ ã³ ã 㥠ãŒã 㣠㳠㰠ã ㌠ã éã®éä¿¡ã«ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã䜿çšã§ ã ãŸãã ï® I/O ïŒ ã€ ãŒãµã ã ã ã¯ã NFS ãµãŒããŒãäœ¿çš ã ãã ãŸã㯠PVFS 㪠ã©ã®ã ã© ã¬ã« ã ã¡ ã€ã«ã· ã¹ ãã ãäœ¿çš ã ãã ã ã¡ ã€ã«å
±æããã³ ã³ ã³ ã 㥠ãŒã 㣠㳠㰠ã ㌠ã ãž ã®ã㌠㿠ã®æäŸã«äœ¿çšã§ ã ãŸãã ï® ç®¡ç ïŒ ã€ ãŒãµã ã ã ã¯ã 㯠㩠㹠㿠ã ㌠ã ã®åž¯åå€ç®¡ç ïŒDell Embedded Remot
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
Oracle QLogic Oracle® 㜠㪠㥠ãŒã· 㧠㳠㹠㿠ã 㯠ã§ã¯ã å³ 11-8 ã«ç€ºãã ã ã«ã 㯠㩠〠㢠㳠ã 㟠ãã¯ã㌠㿠ããŒã¹ 㬠ã€ã€ã®äžäœã«ã ã 㢠ã 㪠ã±ãŒã· 㧠㳠㬠〠ã€ã察象 ãš ã ãŠã ã 㩠〠ã㌠ã ã ã ã ã¯ãŒ 㯠ïŒã¢ ã 㪠ã±ãŒã· 㧠㳠㯠㩠㹠㿠[RAC] ã ㌠ã éã®çžäºæ¥ç¶ïŒ ãš ãã 㪠ã 㯠ã ã ã ã¯ãŒ ã¯ã®äž¡æ¹ã§ ã¢ã ã ã¿ ãŒã®ããŒã åããµã㌠ã ã ãŸãã å³ 11-8.
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
ããŒã åãšãããã¯ãŒã¯ããã¯ã¢ãã ããŒã å ã ãŠããªãç°å¢ã§ã ã ã ã ã¯ãŒ 㯠ã ã 㯠㢠ã ã ãå®è¡ãã ãš ã ã ã 㯠㢠ã ã ãµãŒã㌠ã¢ã ã ã¿ ã®å
šäœçãªè»¢éé床ã¯ã éå°ãª ã ã© ã 㣠ã 㯠㚠ã¢ã ã ã¿ ã®å€§ã ãªè² è· ã« ã 㣠ãŠã ã ã«åœ±é¿ãåããŸãã ã ã 㯠㢠ã ããµãŒããŒã®æ°ã ã㌠㿠㹠ã 㪠ãŒã ã ã㌠ã ã 㩠〠ãã®é床㫠ã 㣠ãŠã¯ã ã ã 㯠㢠ã ã ã ã© ã 㣠ã ã¯ã¯ã ã ã ã ã¯ãŒ 㯠㪠㳠㯠ã®åž¯ åå¹
ã®å€§éšåãç°¡åã«æ¶è²»ããã®ã§ã å®çšŒåç°å¢ã®ã㌠㿠åŠçé床ãããŒãã ã 㯠㢠ã ãã®ã ã ã© ãŒã ã³ ã¹ã«åœ±é¿ãåºãŸãã ã ã ã ã¯ãŒ ã¯ã ã 㯠㢠ã ãã¯ã éåžžã NetBackup⢠ã Exec⢠㪠ã©ã®ããŒãã ã 㯠㢠ã ã 㜠ã ã ㊠㧠㢠ãå®è¡ããå°çšã® ã ã 㯠㢠ã ããµãŒããŒã§æ§æ ã ããŸãã ã ã 㯠㢠ã ã ãµãŒããŒã«æ¥ç¶ããããã€
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
4 ã€ã® 㯠㩠〠㢠㳠ã ãµãŒããŒãã ãã®ã§ã ã ã 㯠㢠ã ã ãµãŒããŒã¯ã ãã«ã ã 㩠〠ã ãªãŒ ã ããŒãã«å¯Ÿ ã ãŠã åæã« 4 ã€ã®ã ã 㯠㢠ã ã 㞠㧠ã ( 㯠㩠〠㢠㳠ã ã ãš ã« 1 㞠㧠ã ) ãå®è¡ã§ ã ãŸãã ãã ã ã 㹠〠ã ã ãš ã ã 㯠㢠ã ããµãŒããŒã®é㮠㪠㳠ã¯ã¯ 1 ã€ã ããªã®ã§ã 4 ã¹ ã 㪠ãŒã ã®ã ã 㯠㢠ã ã ã§ã¯ã ã¢ã ã 㿠㌠㚠㪠㳠ã¯ãç°¡å㫠㪠㜠ãŒã¹äž 足ã®ç¶æ
ã«ãª ãå¯èœæ§ãã ã ãŸãã ã ã 㯠㢠ã ããµãŒããŒã®ã¢ã ã ã¿ ãŒã 1Gbps ïŒ125MB/ ç§ïŒ ã§åäœ ã ãŠã ã ã å 㯠㩠〠㢠㳠ã ãããŒãã ã 㯠㢠ã ãæã« 20MB/ ç§ã§ ã㌠㿠ã転é㧠ã ãå Žåã ã ã 㯠㢠ã ããµãŒã㌠㚠㹠〠ã ãã®éã®ã¹ã«ãŒã ã ã ã¯ã 80MB/ ç§ ïŒ20MB/ ç§ x 4ïŒ ã«ãª ã ãŸãã ã ãã¯ã ã ã
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
æå® ã ãããã¹ã¯ã 以äžã® 2 ã€ã®èŠçŽ ã« ã 㣠ãŠæ±ºãŸ ã ãŸãã ï® ã¯ ã© ã€ ã¢ ã³ ã ãµãŒã㌠ARP ã 㣠ã ã· ã¥ãã ã ã 㯠㢠ã ããµãŒããŒã® MAC 㢠ã 㬠㹠ãæå® ã ãŸãã ã ã®ã¢ ã 㬠ã¹ã¯ã QLogic äžé ã ã© ã€ãã®ã€ ã³ã㊠㳠ã è² è·ãã© ã³ ã· ã³ ã°ã¢ã«ãŽ 㪠ãºã ã« ã 㣠ãŠæ±ºå® ã ããŸãã ï® ã¯ ã© ã€ ã¢ ã³ ã ãµãŒã㌠Red ã®ç©çã¢ã ã 㿠㌠〠㳠㿠ã 㧠ãŒã¹ã¯ã ã㌠㿠ãéä¿¡ ã ãŸãã QLogic äžé ã ã© ã€ãã®ã¢ãŠ ã ã㊠㳠ã è² è·ãã© ã³ ã· ã³ ã°ã¢ã«ãŽ 㪠ãºã ã ã㌠㿠ãæ±ºå® ã ãŸã ïŒ145 ããŒãžã® ãã¢ãŠ ã ã㊠㳠ã ã ã© ã 㣠ã 㯠ã ããŒã ãš 145 ããŒãžã® ã〠ã³ã㊠㳠ã ã ã© ã 㣠ã 㯠ã ã㌠(SLB ã®ã¿ )ã ãåç
§ïŒã ã ã 㯠㢠ã ããµãŒããŒã®ããŒã å〠㳠㿠ã 㧠ãŒã¹ã¯ã 㯠㩠〠㢠㳠ã ãµãŒ
11âQLogic ããŒã åãµãŒã 㹠㢠ã 㪠ã±ãŒã· 㧠ã³ã«é¢ããèæ
®äºé
ã ã 㯠㢠ã ã ãµãŒããŒã第 3ã 第 4 ã®ã ã 㯠㢠ã ãåŠçãéå§ ã ãå Žå ãã å ã ã¢ã«ãŽ 㪠ãºã ãé©çš ã ããŸãã ã ã 㯠㢠ã ã ãµãŒããŒã§ããŒã å ã ã 〠㳠㿠㌠ã 㧠〠ã¹ã¯ã ㊠ãã 㣠㹠ã G-ARP ã転é ã ãŠã ã ã 㯠㢠ã ã 㯠㩠〠㢠㳠ã ã« ARP ã 㣠ã 㷠㥠ãæŽæ° ãã ã ã ã«éç¥ ã ãŸãã ã ã ãŠã å 㯠㩠〠㢠㳠ã ã¯ã ã ã 㯠㢠ã ã ãµãŒããŒäžã® 㿠㌠㲠ã ã MAC 㢠ã 㬠ã¹ã«è³ãã«ãŒ ã ã§ã ã ã 㯠㢠ã ã ã㌠㿠ã転é ã ãŸãã ãã©ãŒã«ããã¬ã©ã³ã¹ ããŒã ã ã 㯠㢠ã ãã®å®è¡äžã«ã ã ã ã¯ãŒ 㯠㪠㳠㯠ã§é害ãçºç ã ãå Žåã ã ã 㯠㢠ã ã ãµãŒã㌠㚠㯠㩠〠㢠㳠ã ã®éã®ãã¹ãŠã® ã ã© ã 㣠ã 㯠ãåæ¢ ã ãŠã ã ã 㯠㢠ã ã 㞠㧠ãã倱æ ã ãŸãã ã ã ã ã QL
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã«é¢ããåé¡ã® ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° å³ 11-10.
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã«é¢ããåé¡ã® ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ï® ãã¹ãŠã® ã ã© ãŒã㌠ã ãåå¥ã«ãµã³ ã 㪠㳠㰠ã ãŸãã ï® ã¢ã ã© ã€ã¶ã§ã¯ã QoS ãš VLAN ã®æ
å ±ã ã 㣠㫠㿠ã ãªãã¢ã ã ã¿ ãš ã ã© ã€ãã䜿 çš ã ãŸãã ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã®è©³çŽ°ã¯ã 以äžã§èª¬æ ã ããŠããŸãã ï® ããŒã åã®èšå®ã® ã ã³ ã ï® ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã®ã¬ 〠ã 㩠〠㳠ããŒã åã®èšå®ã®ãã³ã ã ã ã ã¯ãŒ ã¯æ¥ç¶ãŸãã¯ããŒã åæ©èœã® ã ã© ãã«ã· 㥠ãŒã 㣠㳠㰠ããã ãš ãã¯ã 次ã®èª¬ æãæå® ã ãèšå®ã«åœãŠã¯ãŸ ã ã ãš ãç¢ºèª ã ãŸãã ï® Dell ã§ã¯ ã 㟠ã 㟠ãªé床㮠SLB ãæ··åšãã ããŒã åããµã㌠ã ã ãŠããŸããã ããŒã å
ã®ãã¹ãŠã®ã¢ã ã ã¿ ãŒã¯å ã é床ã«ãã ã ãš ã ãå§ã ã ãŸã ïŒãã¹ãŠã ã®ã¬ ã ã ã 〠ãŒãµã ã ã ãŸãã¯ãã¹ãŠã ã ã¡ ã¹ ã 〠ãŒãµã ã ã ïŒã é床ã 10Gb
11âQLogic ããŒã åãµãŒã ã¹ ããŒã åã«é¢ããåé¡ã® ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ï® ããã¯åäºééä¿¡ ã ããµã㌠ã ã ãªãããã ããŒã ãããã«æ¥ç¶ãã ã ãš ã¯ãå§ ã㧠ã ãŸããã ãã ã ããŒã ã«æ¥ç¶ããã®ã¯ã ã ã© ãã«ã· 㥠ãŒã 㣠㳠㰠ãç®ç ãš ããå Žåã®ã¿ã« ã ㊠ã ã ã ãã LACP ãŸã㯠GEC/FEC ããŒã ã«åå ã ãŠã ã ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ã®ãã〠㹠ã ã© ã€ããã 㣠㹠ãšãŒãã«ãã ãš ã ã ã ã ã¯ãŒ 㯠æ¥ç¶ã«æªåœ±é¿ãäžã ãå Žåãã ã ãŸãã ã ã ã ã¯ãŒ 㯠æ¥ç¶ã®åæãé¿ã ã ãã ã«ã ãã〠㹠ã ã© ã€ããç¡å¹ã«ããåã«ã ãŸã㹠〠ã ãã ã ã¢ã ã ã¿ ãŒãç©çç ã«æããŠã ã ã ãš ã ãå§ã ã ãŸãã ï® ããŒã¹ ïŒ ã ãã㌠ã ïŒ ã ã© ã€ã ãš ããŒã ïŒäžéïŒ ã ã© ã€ããå ã 㪠㪠ãŒã¹ã ã ã±ãŒãž ã§ã ã ã ãš ãç¢ºèª ã ãŸãã Dell ã§ã¯ã ç°ãª ã 㪠㪠ãŒã¹ã®ããŒã¹ ã ã© ã€ã ãš ããŒã ã ã© ã€ã
11âQLogic ããŒã åãµãŒã ã¹ ã ã ãã質å 6. å¯èœãªå Žåã¯ã ããŒã ãåå² ã ã åã¢ã ã ã¿ ãžã®æ¥ç¶ãåå¥ã«èª¿ã¹ãŠã åé¡ãçŽ æ¥ããŒã åã«é¢é£ãã ã ãš ã ãš ã§ã ããã© ã ããç¢ºèª ã ãŸãã 7. ããŒã ã«æ¥ç¶ãããã¹ãŠã®ã¹ 〠ã ã ã㌠ã ãå ã VLAN äžã«ååšãã ã ãš ãç¢ºèª ã ãŸãã 8. 㹠〠ã ã ã㌠ã ãéæäžç¶ (FEC/GEC)/802.3ad-Draft Static ããŒã 㿠〠ãå¯Ÿå¿ ã«æ£ ã ã èšå® ã ããŠãã ã ãš ã ããã³ã¢ãã ã¿ ã®ããŒã 㿠〠ãã«äžèŽ ã ãŠãã ã ãš ãç¢ºèª ã ãŸãã ã· ã¹ ãã ã SLB ããŒã 㿠〠ã察å¿ã«èšå® ã ããŠã ãå Žåã¯ã 察å¿ãã 㹠〠ã ã ã㌠ã ãéæäžç¶ (FEC/GEC)/802.
11âQLogic ããŒã åãµãŒã ã¹ ã ã ãã質å 質å ïŒ ããŒã å ã ããã¢ã ã ã¿ ãããã«æ¥ç¶ã§ ã ãŸããã 察å¿ç ïŒ ããŒã å ã ããã㌠ã 㯠ã ã© ãã«ã· 㥠ãŒã 㣠㳠㰠ãç®ç ãš ããå Žåã«ã®ã¿ãã ã«æ¥ç¶ã§ ã ãŸãã ãã ã ã ã ã®æ¹æ³ã¯ããã®å¶éã« ã 㣠ãŠã ã ã© ãŒã ã³ ã¹ãäœäžãã ã ãã éåžžã®éçšã§ã¯ãå§ã㧠ã ãŸããã ããŒã å ã ããã㌠ã ã¯ã¹ 〠ã ãã«æ¥ç¶ ã ㊠ã ã ã ãã 質å ïŒ ããŒã å ã ããã¢ã ã ã¿ ãã«ãŒ ã¿ ãŒã®ã㌠ã ã«æ¥ç¶ã§ ã ãŸããã åç ïŒ ã§ ã ãŸããã ããŒã å
ã®ã㌠ã ã¯ãã¹ãŠåäžã®ã ã ã ã¯ãŒ ã¯äžã«ååšããå¿
èŠã ã ã ãŸãã ãã ã ã ã«ãŒ ã¿ ãŒã§ã¯ã å®çŸ©äžåã㌠ã ã¯åå¥ã®ã ã ã ã¯ãŒ 㯠ã«ã ã ãŸãã ããŒã åã®ãã¹ãŠã®ã¢ãŒ ã ã§ã¯ã 㪠㳠㯠ã㌠ã ããŒã㬠〠ã€ãŒ 2 㹠〠ã ãã§ã ã ã ãš ã å¿
èŠã§ãã 質å ïŒ Microsoft Cluster Services ã§ããŒã åã䜿çšã§ ã ãŸããïŒ åç
11âQLogic ããŒã åãµãŒã ã¹ ã ã ãã質å 質å ïŒ äžé ã ã© ã€ã ïŒQLASPïŒ ã 㢠ã ãã° ã¬ãŒ ã ããæ¹æ³ãæã㊠ã ã ã ãã 察å¿ç ïŒ [ ã㌠ã«ã«ãš 㪠ã¢æ¥ç¶ã®ã ããã 㣠] ã§ã¯äžé ã ã© ã€ãã 㢠ã ãã° ã¬ãŒ ã 㧠ã 㟠ããã Setup 〠㳠㹠ã ㌠㩠ãäœ¿çš ã ㊠㢠ã ãã° ã¬ãŒ ã ããå¿
èŠãã ã ãŸãã 質å ïŒ ä»®æ³ã¢ã ã 㿠㌠ïŒããŒã ïŒ ã®ã ã ã© ãŒã ã³ ã¹çµ±èšã確èªãã ã«ã¯ã© ã ã ã ã ã ã ã§ããïŒ åç ïŒ QLogic Control Suite ã§ã ä»®æ³ã¢ã ã ã¿ ãŒã® Statistics ïŒçµ±èšïŒ ã¿ ã ã 㯠㪠ã 㯠ã ãŸãã 質å ïŒ ã ã ã ã¯ãŒ ã¯è² è·åæ£ ãš ããŒã åãåæã«èšå®ã§ ã ãŸããïŒ åç ïŒ ã§ ã ãŸãã ãã ã ã ãã«ãã 㣠㹠ã ã¢ãŒ ã ã§ã ã ã ã¯ãŒ ã¯è² è·åæ£ãå®è¡ ã ãŠã ã ãš ãã®ã¿ã§ã ïŒã ã ã ã¯ãŒ ã¯è² è·åæ£ã¯ MS Cluster Services ã§ã¯ãµã㌠ã ã ããŠã ãŸããïŒã 質
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž 質å ïŒ ã 㩠〠ã 㪠ã¢ã ã ã¿ ãå
ã«æ» ã ㊠( ã 㧠ã€ã«ãªãŒããŒåŸã®ã ã© ãŒã«ã ã 㯠) ã ã 30 ïœ 50 ç§éããŒã ã®æ¥ç¶ã倱ãããã®ã¯ãªãã§ããã 察å¿ç ïŒ ã ã© ãŒã«ã ã 㯠〠ã ã³ ã ã®éã 㪠㳠ã¯ã埩å
ã ãã 転éç¶æ
ã«ç§»è¡ã§ ã ã ãš å€ æãã 㟠ã§ã Spanning Tree Protocol ã¯ã㌠ã ã«ã ã ã 㯠ãèšå® ã ãŸãã STP ãåå ã§éä¿¡ãé絶ã ãªãã ã ã«ãã ã«ã¯ã ããŒã ã«æ¥ç¶ ã ãã㹠〠ã ã ã㌠ã äžã§ Port Fast ãŸã㯠Edge Port ãæå¹ã«ããå¿
èŠãã ã ãŸãã 質å ïŒ Windows ãµãŒããŒã§ ã¢ã ã ã¿ ããŒã ã®çµ±èšã 㪠ã¢ã« ã¿ ã€ã ã«ç£èŠãã ã«ã¯ã ã© ã ã ã ã ã ã㧠ã ã ã ãã åç ïŒ QLogic Control Suite ïŒQCSïŒ ãäœ¿çš ã ㊠IEEE 802.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž ããŒã¹ãã©ã€ãïŒç©çã¢ããã¿ãŒãŸãã¯ããããŒãïŒ ããŒã¹ ã ã© ã€ãã¯ã 㜠ãŒã¹ L2ND ã§èå¥ ã ããŸãã è¡š 11-8 ã«ã ããŒã¹ ã ã© ã€ãã§ãµ ã㌠ã ãã 〠ãã³ ã ã ã° ã¡ ã ã»ãŒãž ãäžèŠ§è¡šç€º ã ã ã¡ ã ã»ãŒãžã®åå ã説æ ã ãŸãã 㟠ãã æšå¥š ã ãã察å¿ç ã瀺 ã ãŸãã ã¡ã¢ è¡š 11-8 ã® ã¡ ã ã»ãŒãžçªå· 1 ïœ 17 ã¯ã NDIS 5.x ã ã© ã€ã ãš NDIS 6.x ã ã© ã€ã ã®äž¡æ¹ã«è©²åœ ã ã ã¡ ã ã»ãŒãžçªå· 18 ïœ 23 ã¯ã NDIS 6.x ã ã© ã€ãã«ã®ã¿è©²åœ ã ãŸãã è¡š 11-8. ããŒã¹ ãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ã¡ãã»ãŒãž çªå· 1 é倧床 ãšã©ãŒ ã¡ãã»ãŒãž åå 察å¿ç Failed to allocate memory for the device block. Check system memory resource usage.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-8. ããŒã¹ ãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒãž çªå· 4 é倧床 èŠå ã¡ãã»ãŒãž åå 察å¿ç The network link is down. Check to make sure the network cable is properly connected.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-8. ããŒã¹ ãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒãž çªå· 10 é倧床 æ
å ± ã¡ãã»ãŒãž åå 察å¿ç ã¢ãã ã¿ ã¯ã éžæ ã ãã åç·é床 ãš äºééä¿¡æ¹åŒ ã®èšå®ã«åãããŠæå㧠æ§æ ã ããŠããŸãã 察å¿çã¯å¿
èŠã ã ãŸããã ã¢ãã ã¿ ã¯ã éžæ ã ãã åç·é床 ãš äºééä¿¡æ¹åŒ ã®èšå®ã«åãããŠæå㧠æ§æ ã ããŠããŸãã 察å¿çã¯å¿
èŠã ã ãŸããã ã¢ãã ã¿ ã¯ã éžæ ã ãã åç·é床 ãš äºééä¿¡æ¹åŒ ã®èšå®ã«åãããŠæå㧠æ§æ ã ããŠããŸãã 察å¿çã¯å¿
èŠã ã ãŸããã ãªã ã¬ãŒã 㣠ã³ã° ã·ã¹ ã ã 㯠IEEE 802.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-8. ããŒã¹ ãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒãž çªå· 17 é倧床 æ
å ± ã¡ãã»ãŒãž åå 察å¿ç NDIS is resetting the miniport driver.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-8. ããŒã¹ ãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒãž çªå· 23 é倧床 ãšã©ãŒ ã¡ãã»ãŒãž åå 察å¿ç Network controller failed to exchange the interface with the bus driver.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-9. äžéãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã·ã¹ãã 〠ãã³ãã¡ã ã»ãŒãžçªå· 5 é倧床 æ
å ± ã¡ãã»ãŒãž åå QLASP driver has started.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-9. äžéãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã·ã¹ãã 〠ãã³ãã¡ã ã»ãŒãžçªå· 12 é倧床 ãš ã©ãŒ ã¡ãã»ãŒãž åå 察å¿ç QLASP features driver is not designed to run on this version of operating system.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-9. äžéãã©ã€ãã®ã€ãã³ã ãã° ã¡ãã»ãŒãž ( ç¶ã ) ã·ã¹ãã 〠ãã³ãã¡ã ã»ãŒãžçªå· 17 é倧床 æ
å ± ã¡ãã»ãŒãž åå 察å¿ç Network adapter is activated and is participating in network traffic. ïŒã ã ã ã¯ãŒ 㯠ç©çã¢ãã ã¿ ã¯ããŒã ã« è¿œå ã ãã 㢠㯠ã 㣠ãã« ã ããŠããŸãã 察å¿çã¯å¿
èŠã ã ãŸã ãã ã ã© ã€ãã〠㳠㹠ã ãŒã« ã ããã¢ãã ã¿ ãèªè ã ãŸããã 察å¿çã¯å¿
èŠã ã ãŸã ãã LiveLink 〠ããŒã㫠察å¿çã¯å¿
èŠã ã ãŸã ãã ã¢ãã ã¿ ã¯ã¢ 㯠ã 㣠ãå ã ãã ã ã ã ã¯ãŒ 㯠ã ã© ã 㣠ã 㯠ã«å ã㣠ãŠã ãŸããïŒ 18 æ
å ± Network adapter is deactivated and is no longer participating in network traffic.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž ä»®æ³ãã¹ ãã©ã€ã (VBD) è¡š 11-10 㯠VBD 〠ã ã³ ã ã ã° ã¡ ã ã»ãŒãžã®äžèŠ§ã§ãã è¡š 11-10. ä»®æ³ãã¹ãã©ã€ãïŒVBDïŒã€ãã³ããã°ã¡ãã»ãŒãž ã¡ãã»ãŒ ãžçªå· 1 é倧床 ãš ã©ãŒ ã¡ãã»ãŒãž åå 察å¿ç Failed to allocate memory for the device block. Check system memory resource usage.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-10. ä»®æ³ãã¹ãã©ã€ãïŒVBDïŒã€ãã³ããã°ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒ ãžçªå· 6 é倧床 æ
å ± ã¡ãã»ãŒãž åå 察å¿ç Network controller configured for 100Mb half-duplex link.
11âQLogic ããŒã åãµãŒã 㹠〠ãã³ ã ãã°ã® ã¡ ã ã»ãŒãž è¡š 11-10. ä»®æ³ãã¹ãã©ã€ãïŒVBDïŒã€ãã³ããã°ã¡ãã»ãŒãž ( ç¶ã ) ã¡ãã»ãŒ ãžçªå· 12 é倧床 æ
å ± ã¡ãã»ãŒãž åå 察å¿ç Driver initialized successfully.
12 NIC ããŒãã£ã·ã§ã³åãšåž¯å å¹
管ç æ¬ç« ã§ã¯ã 以äžã® NIC ããŒã 㣠㷠㧠ã³å 㚠垯åå¹
管çã«ã€ããŠèª¬æ ã ãŸãã ï® æŠèŠ ï® 193 ããŒãžã® ãNIC ããŒã 㣠㷠㧠ã³åãæ§æããã æŠèŠ NIC ããŒã 㣠㷠㧠ã³å ïŒNPAR)QLogic BCM57xx ã ãã³ BCM57xxx ã§ã¯ã ã㌠ã ã ãš ã«è€æ°ã® PCI ç©çæ©èœãæèŒãã ã ãš ã§ã 10 Gigabit Ethernet NIC ãè€æ°ã®ä»®æ³ NIC ã«åå² ã ãŸãã ããããã® PCI æ©èœã¯å¥ã
ã®ä»®æ³ NIC ã«é¢é£ä»ã ã ããŸãã OS ã ãã³ã ã ã ã¯ãŒ 㯠ã«å¯Ÿ ã ãŠã¯ã åç©çæ©èœã¯åå¥ã® NIC ã㌠ã ãš ã ãŠè¡šç€º ã ããŸãã åã㌠ã ã®ããŒã 㣠㷠㧠ã³æ°ã¯ 1 ïœ 3 ã§ãã ã ã®ããã ã 㥠ã¢ã«ã㌠ã NIC ã§ã¯æ倧 8 ã€ã®ããŒã 㣠㷠㧠㳠ãèšå®ã§ ã ãŸãã åããŒã 㣠㷠㧠ã³ã¯ã åå¥ã® NIC ã㌠ã ãš åæ§ ã«åäœ ã ãŸãã ããŒã 㣠㷠㧠ã³å ã ãã 10G NIC 㮠㡠㪠ã
12âNIC ããŒã 㣠㷠㧠ã³å 㚠垯åå¹
管ç NIC ããŒã 㣠㷠㧠ã³åãæ§æãã ï± ï± ï± ï® Linux ï± ï± ï± ï± ï® 2012 Server 以éã®ã· 㪠ãŒãº 2016 Server Nano Server RHEL 6.x 以éã®ã· 㪠ãŒãº RHEL 7.x 以éã®ã· 㪠ãŒãº SLES 11.x 以éã®ã· 㪠ãŒãº SLES 12.x 以éã®ã· 㪠ãŒãº VMware ï± ï± ESX 5.x 以éã®ã· 㪠ãŒãº ESX 6.
12âNIC ããŒã 㣠㷠㧠ã³å 㚠垯åå¹
管ç NIC ããŒã 㣠㷠㧠ã³åãæ§æãã CCM ãŠãŒãã£ãªãã£ã䜿çšããŠããŒãã£ã·ã§ã³ååãã« NIC ãèšå®ããã«ã¯ã次ã®æ é ãå®è¡ããŸãã 1. Device List ïŒãã〠㹠㪠㹠ã ïŒ ã§ NIC ãéžæ ã ãŸãã 2. Main Menu ïŒ ã¡ ã€ ã³ ã¡ ã 㥠ãŒïŒ ã ãã Device Hardware Configuration ïŒã ã〠ã¹ã㌠ã ㊠㧠ã¢ã®èšå®ïŒ ãéžæ ã ãŸãã 3. [Multi-Function Mode / ãã«ã ã 㡠㳠㯠㷠㧠㳠ã¢ãŒ ã ] ã [NPAR] ã«å€æŽ ã 㟠ãã 4. NIC Partitioning Configuration ïŒNIC ããŒã 㣠㷠㧠ã³åèšå®ïŒ ㊠㣠㳠ã ãŠã§å© çšã§ ã ãèšå®ã 㩠㡠㌠㿠ã 㪠㹠ã ããã è¡š 12-1 ã«ç€ºããªã 㷠㧠㳠ã«åºã¥ããŠã ã 䜿ãã®èšå®çšã« NIC ã㩠㡠㌠㿠ãèšå® ã ãŸãã è¡š 12-1.
12âNIC ããŒã 㣠㷠㧠ã³å 㚠垯åå¹
管ç NIC ããŒã 㣠㷠㧠ã³åãæ§æãã è¡š 12-2.
12âNIC ããŒã 㣠㷠㧠ã³å 㚠垯åå¹
管ç NIC ããŒã 㣠㷠㧠ã³åãæ§æãã ãã¹ãŠã®æ©èœã«å ã Bandwidth Weight ïŒåž¯åå¹
㊠㧠〠ã ïŒ å€ãèšå®ãã ãš ã èšå®ã« äœ¿çš ã ããå®éã®å€ã« ã 㣠ãŠã ç°å¢ã«å¯Ÿãã圱é¿ãå€ã 㣠㊠ã ãŸãã ã ãš ãã°ã ãã¹ãŠ ã®æ©èœã ã0ã ãŸã㯠ã25ã ãš ã ãŠèšå® ã ããŠããå Žåã è«ççã«ã¯ã ç°å¢ã«å¯Ÿãã圱 é¿ã¯å ã ãš èã ãããŸããã å®éã«ã¯ ã ã ãã®æ©èœã§èšå® ã ãã 㪠ã ã㌠ã ã¯ã ç°ãª ã 垯åå¹
èšå®ã瀺ã ã ãš ã«ãª ã ãŸãã 4 ã€ã®æ©èœ ïŒãŸãã¯ããŒã 㣠㷠㧠ã³ïŒ ãã 次ã«ç€ºãã ã ã«ã åèš 6 åã®ã ã ã ã³ ã«ã§èš å® ã ããŠã ã ãš ã ã èšå®ãäŸã«å ã ãŸãã æ©èœ 0 ï® ï® ã€ ãŒãµã ã ã FCoE æ©èœ 1 ï® ã€ ãŒãµã ã ã æ©èœ 2 ï® ã€ ãŒãµã ã ã æ©èœ 3 ï® ï® 1.
13 Linux QCS ã®ã€ã³ã¹ããŒã« Linux ã ã© ã ã ã ã© ãŒã ã§ã® QLogic Control Suite ã®ã€ ã³ ã¹ ã ãŒã«ã«é¢ããæ
å ±ã¯ã 次 ã® ãš ã ã ã§ãã ï® æŠèŠ ï® 199 ããŒãžã® ãWS-MAN 㟠ã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ã ãã ï® 206 ããŒãžã® ãLinux 㯠㩠〠㢠㳠ã ã« WS-MAN ãŸã㯠CIM-XML ã 〠㳠㹠ã ㌠ã«ããã ï® 207 ããŒãžã® ãQLogic Control Suite ã®ã€ ã³ ã¹ ã ãŒã«ã æŠèŠ QLogic Control Suite ïŒQCSïŒ ã¯ã çµ±åã ã ã ã¯ãŒ 㯠ã¢ã ã 㿠㌠㚠ã åŒã°ãã BCM57xx ããã³ BCM57xxx ã¢ã ã ã¿ ãŒã® ã ã¡ ã 㪠ãèšå®ãã ããã®ç®¡ç㢠ã 㪠ã±ãŒ 㷠㧠㳠ã§ãã QCS 㜠ã ã ㊠㧠ã¢ã¯ã Windows ãš Linux ã®ãµãŒããŒãã㳠㯠㩠〠㢠㳠ã ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã äžã§åäœ ã ãŸãã æ¬ç« ã§ã¯ã QC
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« æŠèŠ éä¿¡ãããã³ã« éä¿¡ã ã ã ã³ ã«ã« ã ã ã ã ãã〠ã 㚠㯠㩠〠㢠㳠ã 㜠ã ã ㊠㧠ã¢ã®éã§æ
å ±ã亀æ㧠ã ãŸãã ã ã ãã¯ã Distributed Management Task Force (DMTF) çå®ã® Web-Based Enterprise Management (WBEM) ãš Common Information Model (CIM) æšæºã®ç¬èª å®è£
ã ã ãã³ãªãŒã 㳠㜠ãŒã¹å®è£
ã§ãã ã ã ã ã¯ãŒ ã¯ç®¡çè
ã¯ã ã ã ã ã¯ãŒ ã¯äžã§äž»ã« äœ¿çš ã ããŠããæšæºã«åºã¥ããŠã æåã®ãªã 㷠㧠㳠ãéžæ㧠ã ãŸãã è¡š 13-1 ã«ã 管çãã¹ ã 㚠㯠㩠〠㢠㳠ã 㫠〠㳠㹠ã ãŒã« ã ããŠã ã OS ã«åºã¥ããŠå©çš å¯èœãªãªã 㷠㧠㳠ã瀺 ã ãŸãã è¡š 13-1.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« ã€ã³ã¹ããŒã«ãã Linux ãµãŒããŒã« WS-MAN ãŸã㯠CIM-XML ã 〠㳠㹠ã ãŒã«ãã ã«ã¯ã 次ã®æé ã« åŸ ã£ ãŠ ã ã ã ãã æé 1 ïŒ OpenPegasus ã 〠㳠㹠ã ãŒã«ãã æé 2 ïŒ ãµãŒããŒã§ CIM ãµãŒããŒãèµ·åãã æé 3 ïŒ ãµãŒããŒã§ OpenPegasus ãèšå®ãã æé 4 ïŒ QLogic CMPI ã ãã〠ã ã 〠㳠㹠ã ãŒã«ãã æé 5 ïŒ Linux ã 㡠〠ã¢ãŠ ã© ãŒã«ãèšå®ãã ïŒå¿
èŠãªå ŽåïŒ æé 6 ïŒ QCS ãš é¢é£ãã管ç㢠ã 㪠ã±ãŒã· 㧠㳠ã 〠㳠㹠ã ãŒã«ãã æé 1ïŒOpenPegasus ãã€ã³ã¹ããŒã«ãã Red Hat Linux OS ã§ã¯ã 2 ã€ã®ã€ ã³ ã¹ ã ãŒã« ãªã 㷠㧠ã³ãå©çšã§ ã ãŸãã ï® ã€ ã³ã ã 㯠㹠RPM ã ã
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã ã¡ã¢ ã· ã¹ ãã 㧠ãRed Hat Security Enhancement for tog-pegasusã ãæå¹ã«ãª 㣠ãŠã ãå Žåã QCS ã«æ¥ç¶ããåã«ã ãã®æ©èœãç¡å¹ã« ã ㊠ã ã ã ãã 詳现ã«ã€ã ãŠã¯ã 次㮠ã ã¡ ã€ã«ãåç
§ ã ㊠ã ã ã ãã /usr/share/doc/tog-pegasus-2.5.2/README.RedHat.Security ç¡å¹ã«ãã ã«ã¯ã /etc/pam.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã ç°å¢å€æ°ãèšå®ãã è¡š 13-2 ã¯ã OpenPegasus ã ãã« ã ãã ããã®ç°å¢å€æ°ã«ã€ããŠèª¬æ ã ãŠããŸãã è¡š 13-2.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã SSL ããµã㌠ã ãã ã«ã¯ã 次ã®ç°å¢å€æ°ãè¿œå ã ãŸãã export PEGASUS_HAS_SSL=true WS-MAN ããµã㌠ã ãã ã«ã¯ã 次ã®ç°å¢å€æ°ãè¿œå ã ãŸãã export PEGASUS_ENABLE_PROTOCOL_WSMAN=true OpenPegasus ã® CIM-XML ã ãã³ WSMAN ã§ã¯ã HTTP ãŸã㯠HTTPS ã§å ã ã㌠ã ãäœ¿çš ã ãŸãã HTTP ãš HTTPS ããããã®ã ã ã©ã« ã ã®ã㌠ã çªå·ã¯ã 5988 ãš 5989 ã§ãã ã¡ã¢ ã ã ãã®ãš 㯠ã¹ã㌠ã 㯠.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã ã¡ã¢ 㜠ãŒã¹ã ã ã³ ã³ãã€ã« ã ãã OpenPegasus ã§ã¯ã CIM ãµãŒããŒãèµ·åãã ãš ã ã« PEGASUS_HOME ãå®çŸ©ããå¿
èŠãã ã ãŸãã ã ã ã ãªã ãš ã CIM ãµãŒã㌠ã¯ã¬ ããž ã 㪠ãæ£ ã ã ã㌠ã ã ãŸããã .bash_profile ã ã¡ ã€ã«å
㧠PEGASUS_HOME ãèšå®ãã ã ãš ãèæ
® ã ㊠ã ã ã ãã æé 3ïŒãµãŒããŒã§ OpenPegasus ãèšå®ãã è¡š 13-3 ã«ç€ºãã ã ã«ã cimconfig ã³ ã ã³ ã ãçºè¡ ã ㊠OpenPegasus ãèšå® ã 㟠ãã è¡š 13-3.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã æš©éãæ 㣠ããŠãŒã¶ãŒã®èšå® ïŒ Linux ã· ã¹ ãã ãŠãŒã¶ãŒã¯ã OpenPegasus ã®èªèšŒã«äœ¿ ãããŸãã 次ã®ã ã ã«ã cimuser ã³ ã ã³ ã ãäœ¿çš ã ㊠㷠㹠ãã ãŠãŒã¶ãŒã OpenPegasus ã«è¿œå ã ã QCS ã§æ¥ç¶ ã ãŸãã cimuser -a -u -w äŸ ïŒ cimuser -a -u root -w linux1 HTTP ãæå¹ã«ãã 次ã®æé ã«åŸ 㣠ãŠã HTTP ãæå¹ã« ã ãŸãã 1. ãŸã èµ·å ã ãŠããªãå Žåã CIM ãµãŒããŒãèµ·å ã ãŸãã 2. 次㮠㳠ã ã³ ã ãçºè¡ ã ㊠HTTP ã㌠ã ãèšå® ã ãŸã ïŒãªã 㷠㧠ã³ïŒã cimconfig -s httpPort=5988 -p Inbox OpenPegasus ã§ã¯ã ã ã®ã ããã 㣠ã¯å©çšã§ ã ãŸããã 3.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« WS-MAN ãŸã㯠CIM-XML ã Linux ãµãŒããŒã« 〠㳠㹠ã ãŒã«ãã ã¢ã³ã€ã³ã¹ããŒã« QLogic CMPI ã ãã〠ã ã 㢠㳠〠㳠㹠ã ãŒã«ãã ã«ã¯ã 次㮠㳠ã ã³ ã ãçºè¡ ã ãŸãã % rpm -e QLGC_CMPIProvider æé 5ïŒLinux ãã¡ã€ã¢ãŠã©ãŒã«ãèšå®ããïŒå¿
èŠãªå ŽåïŒ ã 㡠〠ã¢ãŠ ã© ãŒã«ã§é©åãªã㌠ã ãé ã ã«ã¯ã 次ã®è©²åœããæé ãå®è¡ ã ãŸãã Red Hat Red Hat 㧠Linux ãã¡ã€ã¢ãŠã©ãŒã«ãèšå®ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. [System/ ã· ã¹ ãã ] ã 㯠㪠ã 㯠ã ã [Administration/ 管ç ] ãéžæ ã ã [Firewall/ ã 㡠〠ã¢ãŒãŠ ã© ãŒã« ] ãéžæ ã ãŸãã 2. [Other Ports/ ãã®ä»ã®ã㌠ã ] ãéžæ ã ãŸãã 3.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« Linux 㯠㩠〠㢠㳠ã ã« WS-MAN ãŸã㯠CIM-XML ã 〠㳠㹠ã ãŒã«ãã ã ãš ãã°ã CIM-XML ã®å Žåã 次ã®å€ãäœ¿çš ã ãŸãã ï± ï± ï± ï± 7.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« QLogic Control Suite ã®ã€ ã³ ã¹ ã ãŒã« 2. 次㮠㳠ã ã³ ã ãçºè¡ ã ãŠã ã ã· ã¥å€ãäœæ ã ãŸãã openssl x509 -noout -hash -in hostname.pem 次ã®ã ã ãªå€ãè¿ ã ããŸãã 100940db 3. 次㮠㳠ã ã³ ã ãçºè¡ ã ãŠã ã ã· ã¥å€ãžã®ã· ã³ã 㪠ã 㯠㪠㳠㯠ãäœæ ã ãŸãã ln -s hostname.pem 100940db.
13âLinux QCS ã®ã€ ã³ ã¹ ã ãŒã« QLogic Control Suite ã®ã€ ã³ ã¹ ã ãŒã« QCS ãåé€ããã«ã¯ã次ã®æé ãå®è¡ããŸãã RPM ã ã ã±ãŒãž ã 㢠㳠〠㳠㹠ã ãŒã«ãã ã«ã¯ã 次㮠㳠ã ã³ ã ãçºè¡ ã ãŸãã % rpm -e QCS 208 BC0054508-04 J
14 ãã¡ã€ããŒãã£ãã«ãªãŒã㌠ã€ãŒãµããã ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã ïŒFCoEïŒ ã®æ
å ±ã«ã¯ã 以äžãå«ãŸããŸãã ï® æŠèŠ ï® 210 ããŒãžã® ãSAN ã ã ã® FCoE ã㌠ã ã ï® 248 ããŒãžã® ãFCoE ãèšå®ããã ï® 250 ããŒãžã® ãN_Port ID Virtualization ïŒNPIVïŒã æŠèŠ ä»æ¥ã®ã㌠㿠㻠㳠㿠ãŒã§ã¯ã ã ã ã ã¯ãŒ 㯠æ¥ç¶ã¹ ã ã¬ãŒãž ïŒNASïŒã 管çã IPCã ã¹ ã 㬠ãŒãž 㪠ã©ã®è€æ°ã®ã ã ã ã¯ãŒ ã¯ãã å¿
èŠ ãš ã ããã ã ã© ãŒã ã³ ã¹ ãš æ±çšæ§éæãã ã ãã«äœ¿çš ã ããŠããŸãã çŸåšã§ã¯ã ã¹ ã 㬠ãŒãž 㜠㪠㥠ãŒã· 㧠ã³çšã® iSCSI ã«å ã ãŠã ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã ïŒFCoEïŒ ãã 察å¿å¯èœãª QLogic C-NIC ãš ãš ã ã«äœ¿çšã§ ã ãŸãã FCoE ã¯ã ã ã¡ ã€ã ã 㣠ãã« ã ã ã ã³ ã«ã Ethernet çµç±ã§è»¢é 㧠ã ã ã ã ã«ããæšæºã§ã
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ï® æ¡åŒµäŒééžæ ïŒETSïŒ ãš ãš ã ã« FCoE ã ã© ã 㣠ã 㯠㫠㪠㳠㯠垯åå¹
ãå² ã åœãŠ ã DCB DCB ã§ã¯ã ã¹ ã 㬠ãŒãžã 管çã ã³ ã³ ã 㥠ãŒã 㣠㳠ã°ã ããã³éä¿¡ã®å ã ã¡ ã 㪠ã 㯠ãã æšæºã® Ethernet ã ã ã ã¯ãŒ 㯠ã ã ç°¡åã«å°å
¥ã 㢠ã ã㰠㬠㌠ã ã ã ãã³ç¶æ㧠ã ãå äžã®ç©ç ã ã¡ ã 㪠ã 㯠ã«çµã¿èŸŒã ã ãš ã㧠ã ãŸãã DCB ã 㯠ã ã ãž ã䜿çšãã ãš ã å¯Ÿå¿ å¯èœãª QLogic C-NIC ã§ã¯ã ã㌠㿠㻠㳠㿠ãŒã®ç©ç 㪠㳠ã¯ã®ã 㹠㬠ã¹ã®ã㌠㿠é
ä¿¡ã äœ é
延ã ã ãã³æšæºããŒã¹ã®åž¯åå¹
å
±æãå®çŸã§ ã ãŸãã DCB ã§ã¯ã FCoEã iSCSIã ã ã ã ã¯ãŒ ã¯æ¥ç¶ã¹ ã 㬠ãŒãž ïŒNASïŒã 管çã ã ãã³ IPC ã® ã ã© ã 㣠ã 㯠ã ããŒããµ ã㌠ã ã ããŠããŸãã DCB ã®è©³çŽ°ã«ã€ããŠã¯ã 第
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã FCoE ããŒãçšã® QLogic Multiple Boot Agent ã®æºåïŒCCMïŒ CCM ã¯ã ã· ã¹ ãã ã㬠ã¬ã·ãŒã㌠ã ã¢ãŒ ã ã«èšå® ã ããŠãã ãš ã ã«ã®ã¿äœ¿çšã§ ã ãŸãã ã· ã¹ ãã ã UEFI ã㌠ã ã¢ãŒ ã ã«èšå® ã ããŠãã ãš ã ã«ã¯äœ¿çšã§ ã ãŸããã ã© ã¡ ã ã® ã¢ãŒ ã 㧠ã UEFI ãã〠ã¹èšå®ããŒãž ã䜿çšã§ ã ãŸãã 1. POST äžã« CCM ãŠãŒã 㣠㪠ã 㣠ãèµ·å ã ãŸãã QLogic Ethernet Boot Agent ãã㌠ïŒå³ 14-1ïŒ ã§ã CTRL+S ããŒãæŒ ã ãŸãã å³ 14-1. CCM ãŠãŒãã£ãªãã£ã®èµ·å 2.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 3. ãã〠㹠㧠DCB ãš DCBX ãæå¹ã«ãª 㣠ãŠã ã ã ãš ãç¢ºèª ã ãŸã ïŒå³ 14-3ïŒã FCoE ã㌠ã ã¯ã DCBX 察å¿ã®èšå®ã§ã®ã¿ãµã㌠ã ã ããŠããŸãã ã ã®ããã DCB ãš DCBX ãæå¹ã§ã ã ã çŽæ¥æ¥ç¶ ã ããŠãã 㪠㳠㯠ã 㢠ãã DCBX ãš ã®å® å
šåæãå¯èœã«ããã 㩠㡠㌠㿠ãäœ¿çš ã ㊠DCBX 察å¿ã§ã ãå¿
èŠãã ã ãŸãã å³ 14-3. CCM ããã€ã¹ã®ããŒããŠã§ã¢æ§æ 4.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ãã以å€ã®ãã¹ãŠã®ãã〠㹠ã§ã¯ã CCM MBA Configuration Menu ïŒMBA èš å® ã¡ ã 㥠ãŒïŒ ãäœ¿çš ã ãŠã Boot Protocol ïŒã㌠ã ã ã ã ã³ ã«ïŒ ãªã 㷠㧠㳠ã FCoE ã«èšå® ã ãŸã ïŒå³ 14-4ïŒã å³ 14-4.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. ã㌠ã ã¿ ãŒã² ã ã ãš LUN ãèšå® ã ãŸãã Target Information ïŒ ã¿ ãŒã² ã ã æ
å ±ïŒ ã¡ ã 㥠ãŒã ãã æåã«å©çšã§ ã ããã¹ ãéžæ ã ãŸã ïŒå³ 14-5ïŒã å³ 14-5. CCM ã¿ãŒã²ããæ
å ± 6. Connect ïŒæ¥ç¶ïŒ ãªã 㷠㧠㳠ãæå¹ã« ã ãŠã ã ã ã㌠ã ã«äœ¿çšãã ã¿ ãŒã² ã ã ã® ã¿ ãŒã² ã ã WWPN ããã³ã㌠ã LUN æ
å ±ãèšå® ã ãŸã ïŒå³ 14-6ïŒã å³ 14-6.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ã¿ ãŒã² ã ã æ
å ±ã¯ã å€æŽã瀺 ã ãŸã ïŒå³ 14-7ïŒã å³ 14-7. CCM ã¿ãŒã²ããæ
å ±ïŒèšå®åŸïŒ 7. çµäº ãš å€æŽã®ä¿åãæ±ããæ瀺 ã¡ ã ã»ãŒãžã衚瀺 ã ãã 㟠ã§ã ESC ããŒãæŒ ã 㟠ãã CCM ãçµäºãã ã«ã¯ã ã· ã¹ ãã ãåèµ·å ã ã å€æŽãé©çš ã ãŠã CTRL+ALT+DEL ããŒãæŒ ã ãŸãã 8. SAN 㧠㹠ã ã¬ãŒãž 㢠㯠ã»ã¹ãã ã ã 㞠㧠ã ã³ ã° ã ãã ã ã OS ã®ã€ ã³ ã¹ ã ãŒã«ã« é²ã¿ãŸãã FCoE ããŒãçšã® QLogic Multiple Boot Agent ã®æºåïŒUEFIïŒ FCoE ããŒãçšã« QLogic Multiple Boot Agent ãæºåããã«ã¯ïŒUEFIïŒã次ã®æé ãå®è¡ããŸãã 1.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã å³ 14-8. FCoE ããŒãèšå®ã¡ãã¥ãŒ 4. FCoE Boot Configuration ïŒFCoE ã㌠ã èšå®ïŒ ã¡ ã 㥠ãŒã§ã 次ã®æé ãå®è¡ ã ãŸãã a. Connect ïŒæ¥ç¶ïŒ ã 㣠ãŒã« ã 㧠Enabled ïŒæå¹ïŒ ãéžæ ã ãŸãã b. World Wide Port Name Target ïŒã¯ãŒã« ã 㯠〠ã ã㌠ã å ã¿ ãŒã² ã ã ïŒ ã å
¥å ã ãŸãã c. 5. Boot LUN ïŒã㌠ã LUNïŒ ãå
¥å ã ãŸãã FCoE Configuration ïŒFCoE èšå®ïŒ ã¡ ã 㥠ãŒã§ã FCoE General Parameters ïŒFCoE äžè¬ãã© ã¡ ãŒ ã¿ ïŒ ãéžæ ã ãŸãã FCoE General Parameters ïŒFCoE äžè¬ã ã© ã¡ ãŒ ã¿ ïŒ ã¡ ã 㥠ãŒã衚瀺 ã ããŸã ïŒå³ 14-9 ãåç
§ïŒã å³ 14-9.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 6. FCoE General Parameters ïŒFCoE äžè¬ã ã© ã¡ ãŒ ã¿ ïŒ ã¡ ã 㥠ãŒã§ã 次ã®æé ã å®è¡ ã ãŸãã a.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ããªããããžã§ãã³ã° ã 㪠ã ã ã 㞠㧠ã ã³ ã°ã§ã¯ã 〠ãã· ãšãŒ ã¿ WWPN ã«æ³šç® ã ã ã ã¡ ã 㪠ã 㯠ãŸãŒã ã³ ã° ãš ã¹ ã 㬠ãŒãžéžæç LUN ã ã¬ãŒã³ ããŒã· 㧠㳠ãæåã§å€æŽ ã ãŠã 〠ã ã· ãšãŒ ã¿ ã«é©å ã«ã¢ 㯠ã»ã¹ã§ ã ã ã ã ã« ã ãŸãã 〠ã ã· ãšãŒ ã¿ WWPN ã¯ã FCoE ã㌠ã ã¿ ãŒã² ã ã èšå®ãŠ 㣠㳠ã ãŠã®ã 〠ã³ã®äžéšã§ç¢º èªã§ ã ãŸãã 〠ã ã· ãšãŒ ã¿ WWPN ã¯ã ã㌠ã çšã«èšç» ã ããŠã ã 〠㳠㿠㌠ã 㧠〠ã¹ã«é¢é£ä»ã ã ã ãŠã ã FIP MAC 㢠ã 㬠ã¹ã ãçŽæ¥æšæž¬ãã ã ãš ã 㧠ã ãŸãã ã¢ã ã ã¿ ã® SFP+ ã±ãŒãž ã«æ·»ä» ã ããŠãã ã¹ ã ã ã« ãŒã«ã¯ã 2 ã€ã® MAC 㢠ã 㬠ã¹ãå°å· ã ããŠããŸãã FIP MAC ã®æ«å°Ÿã¯å¥æ°ã«ãª 㣠ãŠããŸãã WWPN 㯠20:00: + ãš
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. 〠ã ã· ãšãŒ ã¿ ã ã ã¡ ã 㪠ã 㯠㫠ã 㰠〠㳠ã ㊠ã ã ã¿ ãŒã² ã ã ã« ã 㰠〠㳠㧠ã ãªã å Žåã CTRL+R ããŒãæŒã ãš ã ã㌠ã ã ã ã»ã¹ãäžæåæ¢ ã ãã ã ã¡ ã 㪠ã 㯠ãŸãŒã ã³ ã° ãèšå®ã§ ã ã ã ã ã«ãª ã ãŸãã ãŸãŒã ã³ ã°ãå®äºãã ãš ã 〠ã ã· ãšãŒ ã¿ ã¯å¯èŠãªãã¹ãŠã® ã¿ ãŒã² ã ã ã«èªåçã« ã 㰠〠㳠ã ãŸãã 6. 〠ã ã· ãšãŒ ã¿ ãæé 1 㧠ã ã ã 㞠㧠ã ã³ ã° ã ããæå® ã ãã ã¿ ãŒã² ã ã ã®æå® ã ãã LUN ãæ€åºã§ ã ãªãå Žåã CTRL+R ããŒãæŒã ãš ã ã㌠ã ã ã ã»ã¹ãäžæ åæ¢ ã ãã éžæç LUN ã ã¬ãŒã³ ããŒã· 㧠㳠ãèšå®ã§ ã ã ã ã ã«ãª ã ãŸãã 7.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ï® CCM ã ã ã[MBA] èšå®ã® [Option ROM/ ãªã 㷠㧠㳠ROM] èšå®ã [One Time Disabled/ 㯠㳠㿠〠ã ã 㣠ã»ãŒãã« ] ã«èšå® ã ãŸãã ã ã®èšå®ã䜿çšãã ãš ã FCoE ROM ãã㌠ã ã ãã æºåå®äºç¶æ
ã® LUN ãæ€åº ã ãã ãš ã èªåçã«è¿å ã ãŸãã 〠㳠㹠ã ãŒã«åŸã«åèµ·åãã ãš ã ãªã 㷠㧠㳠ROM ãèªåçã« [Enabled/ 〠ããŒãã« ] ã«æ» ã ããŸãã ãã¹ãŠã®ãªã 㷠㧠㳠ROM ãããŒãåºãã®ãåŸ
ã¡ ãŸãã FCoE ã㌠ã ã¯ã åŒã³åº ã ãã ãš ã å³ 14-10 ã«ç€ºãã ã ã« ã¿ ãŒã² ã ã ã«æ¥ç¶ ã ã CTRL+D ããŒãæŒ ã ãŠè¿åãåŒã³åº ã㟠㧠4 ç§åŸ
æ©ãã ㊠㣠㳠ã ãŠã衚瀺 ã ããŸãã CTRL+D ããŒãæŒ ã ãŠã 〠㳠㹠ã ㌠ã«ã«é²ã¿ãŸãã å³ 14-10.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. 〠㳠㹠ã ãŒã«å¯Ÿè±¡ã®ã 㣠㹠㯠ãéžæããåã«ã USB ã ã© ã 㷠㥠ã 㩠〠ã ãå ã å€ ã ãŸãã Windows Server 2008 SP2 FCoE ããŒããã€ã³ã¹ããŒã«ããã«ã¯ã次ã®æé ãå®è¡ ããŸãã 1. EVBD ã ã© ã€ãã ã㌠ã ã ãŸã ïŒå³ 14-11ïŒã å³ 14-11.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 2. bxfcoe ïŒOFCïŒ ã ã© ã€ãã ã㌠ã ã ãŸã ïŒå³ 14-12ïŒã å³ 14-12. bxfcoe ãã©ã€ãã®ã€ã³ã¹ããŒã« 3. 〠㳠㹠ã ãŒã«ãã ã㌠ã LUN ãéžæ ã ãŸã ïŒå³ 14-13ïŒã å³ 14-13. ã€ã³ã¹ããŒã«ãã£ã¹ã¯ããŒãã£ã·ã§ã³ã®éžæ 4.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã SLES 11 SP3 ããã³ SLES 12 ã®ã€ã³ã¹ããŒã« 1. 〠㳠㹠ã ãŒã«ãéå§ãã ã«ã¯ã 次ã®æé ãå®è¡ ã ãŸãã a. SLES 〠㳠㹠ã ãŒã« ã¡ ã 㣠ã¢ã ã ã㌠ã ã ãŸãã b. 〠㳠㹠ã ãŒã«ã¹ ã ã© ã 㷠㥠㊠㣠㳠ã ãŠã§ã ã ã© ã€ãæŽæ°ã 㣠㹠㯠ã«å¿ ã ã F6 ããŒãæŒ ã ãŸãã c. Yes ãéžæ ã ãŸãã d. Boot Options ïŒã㌠ã ãªã 㷠㧠ã³ïŒ 㧠ãwithfcoe=1ã ãš å
¥å ã ãŸãã e. Installation ïŒã€ ã³ ã¹ ã ãŒã«ïŒ ã 㯠㪠ã 㯠ã ãŠç¶è¡ ã ãŸã ïŒå³ 14-14ïŒã å³ 14-14.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 2. æ瀺 ã¡ ã ã»ãŒãžã«åŸ 㣠ãŠã ã ã© ã€ãæŽæ° ã¡ ã 㣠㢠ãéžæ ã ㊠ïŒå³ 14-15ïŒã ã 㩠〠ãã ã㌠ã ã ãŸã ïŒå³ 14-16ïŒã å³ 14-15. ãã©ã€ãæŽæ°ã¡ãã£ã¢ã®éžæ å³ 14-16. ãã©ã€ãã®ããŒã 3.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 4. èŠæ± ã ãã ãã Configure FCoE Interfaces ïŒFCoE 〠㳠㿠ã 㧠ãŒã¹ã®èšå®ïŒ ã 㯠㪠ã 㯠ã ãŸã ïŒå³ 14-17ïŒã å³ 14-17.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. SAN ã㌠ã ãã¹ ãš ã ãŠäœ¿çšãã 10GbE QLogic 〠ã ã· ãšãŒ ã¿ ã㌠ã 㧠FCoE Enable ïŒFCoE ã®æå¹åïŒ ã yes ïŒã¯ãïŒ ã«èšå® ã ããŠãã ã ãš ãç¢ºèª ã ãŸã ïŒå³ 14-18ïŒã å³ 14-18. FCoE ã®æå¹å 6. FCoE ã㌠ã ãæå¹ã«ãã 〠㳠㿠ã 㧠ãŒã¹ ã ãš ã«ã 次ã®æé ãå®è¡ ã ãŸãã a. Change Settings ïŒèšå®ã®å€æŽïŒ ã 㯠㪠ã 㯠ã ãŸãã b. Change FCoE Settings ïŒFCoE èšå®ã®å€æŽïŒ ㊠㣠㳠ã ㊠ïŒå³ 14-19ïŒ ã§ã FCoE Enable ïŒFCoE ã®æå¹åïŒ ãš Auto_VLAN ã yes ïŒã¯ãïŒ ã«èšå® ã ããŠãã ã ãš ãç¢ºèª ã ãŸãã c. DCB Required ïŒDCB ã¯å¿
é ïŒ ã no ïŒãããïŒ ã«èšå® ã ããŠã ã ã ãš ã ç¢ºèª ã ãŸãã d.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã å³ 14-19. FCoE èšå®ã®å€æŽ 7. FCoE ã㌠ã ãæå¹ã«ãã 〠㳠㿠ã 㧠ãŒã¹ ã ãš ã«ã 次ã®æé ãå®è¡ ã ãŸãã a. Create FCoE VLAN Interface ïŒFCoE VLAN 〠㳠㿠ã 㧠ãŒã¹ã®äœæïŒ ã 㯠㪠ã 㯠ã ãŸãã b.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 8. ãã¹ãŠã®ã€ ã³ ã¿ ã 㧠ãŒã¹ã®èšå®ãå®äº ã ã ãã OK ã 㯠㪠ã 㯠ã ãŠæ¬¡ã«é²ã¿ãŸã ïŒå³ 14-20ïŒã å³ 14-20. FCoE ã€ã³ã¿ãã§ãŒã¹ã®èšå® 9.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 10. YaST2 ã§ã¯ã ãã«ããã¹ã®ã¢ 㯠ã 㣠ãåãæ±ããæ瀺 ã¡ ã ã»ãŒãžã衚瀺 ã ã㟠ãã å¿
èŠã«å¿ ã ãŠåç ã ãŸã ïŒå³ 14-21ïŒã å³ 14-21. ãã£ã¹ã¯ã®ã¢ã¯ãã£ãå 11.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 12. Installation Settings ïŒã€ ã³ ã¹ ã ãŒã«ã®èšå®ïŒ ㊠㣠㳠ã ãŠã® Expert ïŒãšãã¹ã㌠ã ïŒ ããŒãž ã§ã Booting ïŒã㌠ã ïŒ ã 㯠㪠ã 㯠ã ãŸã ïŒå³ 14-22ïŒã å³ 14-22.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 13. Boot Loader Installation ïŒã㌠ã ããŒã 〠㳠㹠ã ãŒã«ïŒ ã¿ ã ã 㯠㪠ã 㯠ã ãŠã ã ã Boot Loader Installation Details ïŒã㌠ã ããŒã 〠㳠㹠ã ãŒã«ã®è©³çŽ°ïŒ ã éžæ ã ãŸãã ã ã ã« 1 ã€ã®ã㌠ã ããŒããš ã³ ã 㪠ãã ã ã ãš ãç¢ºèª ã ãŸãã åé· ãª ãš ã³ ã 㪠ã¯ãã¹ãŠåé€ ã ãŸã ïŒå³ 14-23ïŒã å³ 14-23. ããŒãããŒãããã€ã¹ããã 14. [OK] ã 㯠㪠ã 㯠ã ãŠæ¬¡ã«é²ã¿ã 〠㳠㹠ã ãŒã«ãå®äº ã ãŸãã RHEL 6 ãžã®ã€ã³ã¹ããŒã« RHEL 6 äžã« Linux FCoE ããŒããã€ã³ã¹ããŒã«ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. 〠㳠㹠ã ãŒã« ã¡ ã 㣠ã¢ãã ã㌠ã ã ãŸãã RHEL 6.3 ãš 6.4 ã§ã¯æé ã¯ç°ãª ã 㟠ãã RHEL 6.3 ã®å ŽåïŒ a.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã Anaconda æŽæ°ã€ ã¡ ãŒãžã®ã€ ã³ ã¹ ã ãŒã«ã®è©³çŽ°ã«ã€ããŠã¯ã ãRed Hat Installation Guideã ïŒRed Hat 〠㳠㹠ã ãŒã«ã¬ 〠ã ïŒ ã®ç¬¬ 28.1.3 é
ãåç
§ ã ㊠ã ã ã ãã http://docs.redhat.com/docs/en-US/Red_Hat_Enterprise_Linux/6/html/Install ation_Guide/ap-admin-options.html#sn-boot-options-update RHEL 6.4 以éã®å Žå ïŒ æŽæ° ã ãã Anaconda ã¯å¿
èŠã ã ãŸããã a. 〠㳠㹠ã ãŒã«ã¹ ã ã© ã 㷠㥠㊠㣠㳠ã ãŠã§ TAB ããŒãæŒ ã ãŸãã b. å³ 14-24 ã«ç€ºãã ã ã«ã dd ãŸãã c. ç¶è¡ãã ã«ã¯ã ENTER ããŒãæŒ ã ãŸãã ãªã 㷠㧠㳠ã ã㌠ã ã³ ã ã³ ã 㩠〠㳠ã«è¿œå ã å³ 14-24.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 2. Do you have a driver disk ïŒ ã ã© ã€ãã 㣠㹠㯠ãã ã ãŸããïŒ ãš è³ªå ã ãã ãã Yes ïŒã¯ãïŒ ãéžæ ã ãŸã ïŒå³ 14-25ïŒã ã¡ã¢ ã ã ã ã¯ãŒ 㯠ãã〠ã¹ã® ã ã© ã€ãã®æŽæ°ã 〠㳠㹠ã ãŒã« ã ãŠããå Žåã RHEL ã§ã¯ã ã ã© ã€ãæŽæ° ã¡ ã 㣠㢠ã ã ã ã ã¯ãŒ 㯠㧠㢠ã ã ã㌠ã 㧠ã 㟠ããã ã㌠ã«ã« ã¡ ã 㣠㢠ãäœ¿çš ã ㊠ã ã ã ãã å³ 14-25. ãã©ã€ããã£ã¹ã¯ã®éžæ 3. ã ã© ã€ããã㌠ã ã ãã ãã 〠㳠㹠ã ãŒã«ãç¶è¡ ã ãŸãã 4.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. [Add Advanced Target/ é«åºŠãª ã¿ ãŒã² ã ã ã®è¿œå ] ã 㯠㪠ã 㯠ã ãŸãã 6. Add FCoE SAN ïŒFCoE SAN ã®è¿œå ïŒ ãéžæ ã ã Add drive ïŒ ã 㩠〠ãã®è¿œ å ïŒ ã 㯠㪠ã 㯠ã ãŸã ïŒå³ 14-26ïŒã å³ 14-26.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 7. FCoE ã㌠ã çšã®å〠㳠㿠ã 㧠ãŒã¹ã«ã€ããŠã 〠㳠㿠ã 㧠ãŒã¹ ãéžæ ã ãŠã Use DCB ïŒDCB ã®äœ¿çšïŒ ã 㪠ã ã«ã Use auto vlan ïŒèªå VLAN ã®äœ¿çšïŒ ã 㪠㳠㫠ã ãŠã ã ã Add FCoE Disk(s) ïŒFCoE ã 㣠㹠ã¯ã®è¿œå ïŒ ã 㯠㪠ã 㯠ã ãŸã ïŒå³ 14-27ïŒã å³ 14-27. FCoE ãã©ã¡ãŒã¿ã®èšå® 8. ãã¹ãŠã®ã€ ãã· ãšãŒ ã¿ ã㌠ã ã«ã€ããŠã ã¹ ã ã ã 8 ã ã 10 ãç¹° ã è¿ ã ãŸãã 9. 衚瀺å¯èœãªãã¹ãŠã® FCoE ã 㣠㹠㯠ãã Multipath Devices ïŒãã«ããã¹ãã〠ã¹ïŒ ãŸã㯠Other SAN Devices ïŒãã®ä»ã® SAN ãã〠ã¹ïŒ ããŒãžã«è¡šç€º ã ãã ã ãš ãç¢ºèª ã ãŸã ïŒå³ 14-28ïŒã å³ 14-28. FCoE ãã£ã¹ã¯ã®ç¢ºèª 10.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 〠㳠㹠ã ãŒã«ã®å®äºåŸã ã· ã¹ ãã ãåèµ·å ã ãŸãã 12. ã㌠ã åŸã ãã¹ãŠã®ã㌠ã ãã¹ãã〠ã¹ãã㌠ã æã«èµ·å ã ãã ã ã ã«èšå® ã ã ãŠã ã ã ãš ãç¢ºèª ã ãŸãã /etc/sysconfig/network-scripts å
ã®å ã ã ã ã¯ãŒ 㯠〠㳠㿠ã 㧠ãŒã¹ config ã ã¡ ã€ã«ã§ onboot=yes ãš èšå® ã ãŸãã 13. On RHEL 6.4 only (RHEL 6.4 ã®å Žåã®ã¿ )ã 次ã®ã ã ã« /boot/grub/menu.lst ãç·šé ã ãŸãã a. kernel /vmlinuz ⊠è¡ã ã ã ãã¹ãŠã® fcoe=:nodcb ã㩠㡠㌠㿠ãåé€ ã ãŸãã 〠㳠㹠ã ãŒã«æ ã«èšå® ã ã FCoE 〠㳠㿠ã 㧠ãŒã¹ ãš å ã æ°ã® fcoe= ã 㩠㡠㌠㿠ãååšã ãã¯ãã§ãã b.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã ã¡ã¢ ã ã ã ã¯ãŒ 㯠ãã〠ã¹ã® ã ã© ã€ãã®æŽæ°ã 〠㳠㹠ã ãŒã« ã ãŠããå Žåã RHEL ã§ã¯ã ã ã© ã€ãæŽæ° ã¡ ã 㣠㢠ã ã ã ã ã¯ãŒ 㯠㧠㢠ã ã ã㌠ã 㧠ã 㟠ããã ã㌠ã«ã« ã¡ ã 㣠㢠ãäœ¿çš ã ㊠ã ã ã ãã 6. ã ã© ã€ããã㌠ã ã ãã ãã C ãæŒ ã ㊠〠㳠㹠ã ãŒã«ãç¶è¡ ã ãŸãã 7. Installation Summary ïŒã€ ã³ ã¹ ã ãŒã«ãµã ãª ïŒ ãŠ ã£ ã³ ã ãŠã§ã Installation Destination ïŒã€ ã³ ã¹ ã ãŒã«å
ïŒ ã 㯠㪠ã 㯠ã ãŸãã 8.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 12. Installation Destination ïŒã€ ã³ ã¹ ã ãŒã«å
ïŒ ãŠ ã£ ã³ ã ㊠ïŒå³ 14-30ïŒ ã® Other Storage Options ïŒãã®ä»ã®ã¹ ã 㬠ãŒãžãªã 㷠㧠ã³ïŒ ã§ã Partitioning ïŒã㌠ã 㣠㷠㧠ã³ïŒ ãªã 㷠㧠㳠ãéžæ ã ã Done ïŒçµäºïŒ ã 㯠㪠ã 㯠ã ãŸãã å³ 14-30. ããŒãã£ã·ã§ã³ãªãã·ã§ã³ã®éžæ 13.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã RHEL 6.2 以é RHEL 6.2 以éã§ã¯ã OS ã§èšå® ã ããŠããªã 〠ãã· ãšãŒ ã¿ ã㌠ã ãä» ã ㊠ã㌠ã ãã ã ã ã«ã· ã¹ ãã ãèšå® ã ããŠã ãå Žåã èªåã㌠ã ã¯æ£åžžã«è¡ãããŸããã 㷠㣠ã ã ã ㊠ã³æã«åé¡ãçºç ã ãŸãã èµ·åå FCoE ã㌠ã ã ã© ã¡ ã¿ ãæŽæ°ããåã«ã ãã¹ãŠã® æ° ã ãã㌠ã ãã¹ã®ã€ ã ã· ãšãŒ ã¿ ã㌠ã ã OS ã§èšå®ããå¿
èŠãã ã ãŸãã 1. ifconfig -a ãäœ¿çš ã ãŠã æ° ã ã è¿œå ã ãã 〠㳠㿠㌠ã 㧠〠ã¹ã®ã ã ã ã¯ãŒ 㯠〠㳠㿠㌠ã 㧠〠ã¹åãç¹å® ã ãŸãã 2. æ° ã ã 〠㳠㿠ã 㧠ãŒã¹ ã ãš ã«ãifname=: ã kernel /vmlinuz ⊠è¡ã«è¿œå ãã ã ãš ã§ã /boot/grub/menu.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã è¡š 14-1. ãµããŒããããŠããã¬ã¬ã·ãŒ BFS ããã³ uEFI BFS ããŒãžã§ã³ ã¬ã¬ã·ãŒ BFS uEFI BFS ESXi 6.5 ãµã㌠ã ãµã㌠ã ESXi FCoE ããŒããã€ã³ã¹ããŒã«ããã«ã¯ã次ã®äœæ¥ãè¡ããŸãã 1. æŽæ° ã ã ESXi 6.0 U2 〠㳠㹠ã ãŒã«ã€ ã¡ ãŒãžãã èµ·å ã ã ã ã ã³ ã ã ã衚瀺 ã ã ã ã ESXi 6.0 U2 installer ïŒESXi 6.0 U2 〠㳠㹠ã ãŒ ã© ïŒ ãéžæ ã ãŸãã 2. Welcome to the VMware ESXi installation ïŒVMware ESXi 〠㳠㹠ã ãŒã«ãžã ã ã ãïŒ ãŠ ã£ ã³ ã ãŠã§ã ENTER ããŒãæŒ ã ãŠç¶è¡ ã ãŸãã 3. EULA ㊠㣠㳠ã ãŠã§ã F11 ããŒãæŒ ã ãŠå¥çŽã«åæ ã ã ç¶è¡ ã ãŸãã 4.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã 5. ESXi and VMFS Found ïŒæ€åº ã ãã ESXi ãš VMFSïŒ ãŠ ã£ ã³ ã ㊠ïŒå³ 14-32ïŒ ã§ ã€ ã³ ã¹ ã ãŒã«æ¹æ³ãéžæ ã ãŸãã å³ 14-32. æ€åºããã ESXi ãš VMFS 6. 7. æ瀺 ã¡ ã ã»ãŒãžã«åŸ 㣠ãŠã 次ã®æé ãå®è¡ ã ãŸãã a. ããŒã㌠ã ã®ã¬ 〠ã¢ãŠ ã ãéžæ ã ãŸãã b. ã«ãŒ ã ãã¹ã¯ãŒ ã ãå
¥å ã ãŠç¢ºèª ã ãŸãã Confirm Install ïŒã€ ã³ ã¹ ã ãŒã«ã®ç¢ºèªïŒ ㊠㣠㳠ã ㊠ïŒå³ 14-33ïŒ ã§ã F11 ããŒã æŒ ã ㊠〠㳠㹠ã ãŒã« ãš åããŒã 㣠㷠㧠㳠ãç¢ºèª ã ãŸãã å³ 14-33. ESXi ã®ã€ã³ã¹ããŒã«ã®ç¢ºèª 8.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã å³ 14-34. ESXi ã€ã³ã¹ããŒã«ã®å®äº 9. 57800 ã㌠ã ãš 57810 ã㌠ã ã§ã¯ã 管çã ã ã ã¯ãŒ 㯠㯠vmnic0 ã§ã¯ã ã ãŸã ãã ã㌠ã åŸã« GUI 㳠㳠㜠ãŒã«ãéãã Configure Management Network ïŒç®¡ çã ã ã ã¯ãŒ 㯠ã®èšå®ïŒ ã衚瀺 ã ãŠã ãã Network Adapters ïŒã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒïŒ ㊠㣠㳠ã ㊠ïŒå³ 14-35ïŒ ã衚瀺 ã ãŠã 管çã ã ã ã¯ãŒ 㯠ãã〠㹠㚠ã ㊠䜿çšãã NIC ãéžæ ã ãŸãã å³ 14-35. ESXi 管çãããã¯ãŒã¯ã®éžæ 10.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã SAN ãã ã® FCoE ã㌠ã å³ 14-36 ã¯ãã®äžäŸã§ãã å³ 14-36.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã 〠㳠㹠ã ãŒã«åŸã« SAN ã ã ã㌠ã ãã ã€ã³ã¹ããŒã«åŸã« SAN ããããŒããã ã㌠ã èšå® ãš OS ã®ã€ ã³ ã¹ ã ãŒã«ãå®äº ã ãåŸã åèµ·å ã ㊠〠㳠㹠ã ãŒã«ã ã ã¹ ã 㧠ã ãŸãã ä»åããã³ãã®åŸã®ãã¹ãŠã®åèµ·åã§ã ãŠãŒã¶ãŒ ãš ã®ä»ã®å¯Ÿè©±æ©èœã¯äžèŠã§ãã CTRL+D æ瀺 ã¡ ã ã»ãŒãž ãç¡èŠ ã ã å³ 14-37 ã«ç€ºãã ã ã«ã ã· ã¹ ãã ã FCoE SAN LUN ã«ã㌠ã 㧠ã ã ã ã ã« ã ãŸãã å³ 14-37.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã 〠㳠㹠ã ãŒã«åŸã« SAN ã ã ã㌠ã ãã 2. æ° ã ã ã ã© ã€ã ããŒãž 㧠ã³ãå«ãŸããŠããã〠ã 㪠RPM ã 〠㳠㹠ã ãŒã« ã ãŸãã ã〠ã 㪠ã ã© ã€ã RPM ãæºåããæé ã«ã€ããŠã¯ã linux-nx2 ã ã ã±ãŒãžã® README ã ã¡ ã€ã«ãåç
§ ã ㊠ã ã ã ãã 3. 次㮠㳠ã ã³ ã ãçºè¡ ã ㊠ramdisk ãæŽæ° ã ãŸãã 4. ï± RHEL 6.x ã· ã¹ ãã ã§ã¯ã dracut -force ãçºè¡ ã ãŸãã ï± SLES 11 SPX ã· ã¹ ãã ã§ã¯ã mkinitrd ãçºè¡ ã ãŸãã /boot ã®äžã§ initrd ã®ç°ãª ãååãäœ¿çš ã ãŠããå Žå ïŒ a. dracut/mkinitrd 㯠ramdisk ãã ã ã© ã« ã ã®å
ã®ååã§æŽæ°ãã ã ãã ã ã ã©ã« ã å€ã§äžæžã ã ãŸãã b.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã 〠㳠㹠ã ãŒã«åŸã« SAN ã ã ã㌠ã ãã SAN ããã® Windows FCoE ããŒãã®ã€ã³ã¹ããŒã«äžã®ãšã©ãŒ Windows ã» ã ã 㢠ã ã 㧠〠㳠㹠ã ãŒã«çš ã ã¡ ã€ã«ã ã㌠ã ãã ãš ã ã« USB ã ã© ã 㷠㥠ã 㩠〠ããæ¥ç¶ ã ããŠã ã ãš ã ã ã© ã€ããæå® ã ㊠〠㳠㹠ã ãŒã«çšã® SAN ã 㣠㹠㯠ã éžæ ã ã ãš ã ã«ãš 㩠㌠㡠ã ã»ãŒãžã衚瀺 ã ããŸãã Windows OS 〠㳠㹠ã ㌠ã©ã ã å ± å ã ããæ ãäžè¬ç㪠㚠㩠㌠㡠ã ã»ãŒãžã¯ã ãWe couldnât create a new partition or locate an existing one.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã FCoE ãèšå®ãã FCoE ãèšå®ãã ã ã ã© ã« ã ã§ã¯ã DCB 㯠QLogic BCM57xx ã ãã³ BCM57xxx FCoE äºæããã³ DCB äºæã® C-NIC ã§æå¹ã«ãª 㣠ãŠããŸãã QLogic BCM57xx ã ãã³ BCM57xxx FCoE ã«ã¯ã DCB 察å¿ã®ã€ ã³ ã¿ ã 㧠ãŒã¹ãå¿
èŠã§ãã Windows ãªã 㬠ãŒã 㣠㳠ã°ã· ã¹ ãã ã®å Žåã 次ã®ãããããäœ¿çš ã ㊠DCB ã㩠㡠㌠㿠ãèšå® ã ãŸãã ï® ï® ï® ï® ï® QCC GUI QCC PowerKit QLogic Control Suite ïŒQCSïŒ CLI ãµãŒã㌠BIOS UEFI HII ãã〠ã¹èšå®ããŒãž QLogic Comprehensive Configuration Management ïŒCCMïŒ ãŠãŒã 㣠㪠ã 㣠QCS ã®è©³çŽ°ã«é¢ ã ãŠã¯ã Cavium Inc.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã FCoE ãèšå®ãã ï® ï® ï® ï® QCS CLI QCC PowerKit ã 㪠ã㌠ã ãµãŒã㌠UEFI HII ã 㪠ã㌠ã CCM QCC GUI ã䜿çšã㊠Windows äžã§ FCoE ãªãããŒãã€ã³ã¹ã¿ã³ã¹ãæå¹ããã³ç¡ å¹ã«ããã«ã¯ã次ã®æé ãå®è¡ããŸãã 1. QCC GUI ãéã ãŸãã 2. å·ŠåŽã®ã 㪠ãŒã 〠ã³ã®ã㌠ã ã ㌠ã ã®äžã§ã ã㌠ã ã®ä»®æ³ãã¹ãã〠㹠〠㳠㹠㿠㳠㹠ãéžæ ã ãŸãã 3. å³åŽã®èšå®ã 〠㳠ã§ã Resource Config ïŒ ãª ãœ ãŒã¹èšå®ïŒ ã¿ ã ã 㯠㪠ã 㯠ã 㟠ãã Resource Config ïŒ ãª ãœ ãŒã¹èšå®ïŒ ããŒãžã衚瀺 ã ããŸã ïŒå³ 14-39 ãåç
§ïŒã å³ 14-39. Resource ConfigïŒãªãœãŒã¹èšå®ïŒããŒãž 4. 次ã®ã ã ã«ã éžæ ã ãã㌠ã ã ãš ã« Resource Config ïŒ ãª ãœ ãŒã¹èšå®ïŒ ããŒãž ã èšå® ã ãŸãã a.
14â ã ã¡ ã€ããŒã 㣠ãã«ãªãŒã㌠〠ãŒãµã ã ã N_Port ID Virtualization ïŒNPIVïŒ 5.
15 ããŒã¿ã»ã³ã¿ãŒããªããžã³ã° æ¬ç« ã§ã¯ã ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ ã°æ©èœã«é¢ãã次ã®æ
å ±ã«ã€ããŠèª¬æ ã ãŸãã ï® æŠèŠ ï® 252 ããŒãžã® ãDCB ã®æ©èœã ï® 253 ããŒãžã® ãDCB ãèšå®ããã ï® 253 ããŒãžã® ãDCB ã®æ¡ä»¶ã ï® 254 ããŒãžã® ãWindows Server 2012 以éã®ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ ã°ã æŠèŠ ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ ã° ïŒDCBïŒ ãš ã¯ã ã㌠㿠㻠㳠㿠ãŒã®ç©ç 㪠㳠ã¯ã®ã 㹠㬠ã¹ã® ã㌠㿠é
ä¿¡ã äœé
延ã ã ãã³æšæºããŒã¹ã®åž¯åå¹
å
±æãå®çŸã§ ã ãã 〠ãŒãµã ã ã ã«å¯Ÿ ãã IEEE æå®ã®æšæºæ¡åŒµæ©èœã®éåã§ãã DCB ã§ã¯ã ã¹ ã ã¬ãŒãžã 管çã ã³ ã³ ã 㥠ãŒã 㣠㳠ã°ã ããã³éä¿¡ã®å ã ã¡ ã 㪠ã 㯠ãã æšæºã® Ethernet ã ã ã ã¯ãŒ 㯠ã ã ç°¡åã«å°å
¥ã 㢠ã ã㰠㬠㌠ã ã ããã³ç¶æ㧠ã ãåäžã®ç©ç ã ã¡ ã 㪠ã 㯠ã«çµã¿èŸŒã ã ãš ã㧠ã ãŸãã
15â ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° DCB ã®æ©èœ DCB ã®æ©èœ DCB ã®æ©èœã«ã¯ã ã ã®é
ã§èª¬æãã ã ã ã«ã ETSã PFCã ããã³ DCBX ãã ã ãŸãã æ¡åŒµäŒééžæ (Enhanced Transmission SelectionãETS) æ¡åŒµäŒééžæ ïŒETSïŒ ã¯ã 垯åå¹
ã ã ã© ã 㣠ã 㯠㯠㩠ã¹ã«å² ã åœãŠ ã ããã®å
±éã®ç®¡ç ã ã¬ãŒã ã¯ãŒ 㯠ãæäŸ ã ãŸãã ããããã® ã ã© ã 㣠ã 㯠㯠㩠㹠ãŸãã¯åªå
床ã¯ã åªå
床 ã°ã«ãŒã ïŒPGïŒ ã«ã°ã«ãŒãå㧠ãã ä»®æ³ ãª ã³ ã¯ ãŸãã¯ä»®æ³ã€ ã³ ã¿ ã 㧠ãŒã¹ã 㥠㌠㚠èŠãª ã ã ãš ã㧠ã ãŸãã ã ã¢ã®äŒéã¹ã±ãž 㥠㌠ã©ã¯ã å PG ã«å² ã åœãŠ ã ãã垯åå¹
ãç¶æ 管ç ã ãŸãã ã ãš ãã°ã ãŠãŒã¶ãŒã¯ã FCoE ã ã© ã 㣠ã 㯠ã PG 0 ã«ã iSCSI ã ã© ã 㣠ã 㯠ã PG 1 ã«å² ã åœãŠ ã ã ã ã«èšå®ã§ ã ãŸãã ãã®åŸã åã°ã«ãŒãã«ç¹å®ã®åž¯å å¹
ãå² ã åœãŠ ã ã ãš ã㧠ã
15â ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° DCB ãèšå®ãã ããŒã¿ã»ã³ã¿ãŒããªããžã³ã°äº€æïŒDCBXïŒ ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ ã°äº€æ ïŒDCBXïŒ ã¯ã æ€åºã ãã³æ©èœäº€æã ã ã ã³ ã«ã§ã ã ã ã ã¯ãŒ 㯠ã ã¡ ã 㪠ã ã¯å
šäœã§äžè²« ã ãèšå®ã確ä¿ãã ããã«ã 㪠㳠ã¯ã㌠ã ããŒé ã®æ©èœã®äŒéããã³ ETS ãš PFC ã®èšå®ã«äœ¿çš ã ããŸãã 2 ã€ã®ãã〠ã¹ãæ
å ±ã亀æ ãã ããã«ã¯ã çæ¹ã®ãã〠ã¹ãä»æ¹ã®ãã〠ã¹ã ãã®ã ã ã ã¯ãŒ 㯠èšå®ãåãå
¥ãã å¿
èŠãã ã ãŸãã ã ãš ãã°ã C-NIC ãæ¥ç¶ ã ããŠãã 㹠〠ã ãã ãã® ETS ãš PFC ã® èšå®æ
å ±ãåãå
¥ãã ã ã ã«èšå® ã ããŠããŠã 㹠〠ã ãã C-NIC ã®åãå
¥ããç¢ºèª ã ãå Žåã 㹠〠ã ã㯠C-NIC ã«æšå¥š ã ãã ETS ãš PFC ã®ã 㩠㡠㌠㿠èšå®ãéä¿¡ ã ãŸãã DCBX ã ã ã ã³ ã«ã¯ã 㪠㳠㯠㬠ãã«æ€åºã ã ã ã³ ã« ïŒLLDPïŒ ãäœ¿çš ã ãŠã 㪠㳠ã¯ã
15â ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° Windows Server 2012 以éã®ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° ï® NIC ããŒã 㣠㷠㧠ã³åãæå¹ãªèšå®ã§ã¯ã ETS ïŒåäœå¯èœãªå ŽåïŒ ãåæ©èœã«å² ã åœãŠ ã ãã垯åå¹
㊠㧠〠ã ã ã ã åªå
ã ããŸãã äŒééžæ㊠㧠〠ã ã¯ã 代ã ã ã« ETS èšå®ã ãš ã®ã ã ã ã³ ã«ã ãš ã«ãª ã ãŸãã æ©èœã ãš ã®æ倧垯åå¹
ã¯ã ETS ãååš ã ãŠã㊠ãäœ¿çš ã ããŸãã ï® DCBX ã ã¢çµç±ã§ 㢠ã ã 㿠〠㺠ã ãã iSCSI ãŸã㯠FCoE 㢠ã 㪠ã±ãŒã· 㧠ã³ã® TLV ããªãå Žåã ã¢ã ã ã¿ ã¯ã㌠ã«ã«ç®¡çè
ã® MIB ã ã ååŸ ã ããèšå®ãäœ¿çš ã ãŸãã Windows Server 2012 以éã®ããŒã¿ã»ã³ã¿ãŒããªã ãžã³ã° Windows Server 2012 ã ã ã Microsoft ã¯ãµãŒã ã¹å質 ïŒQoSïŒ ã OS 㬠ã ã«ã§ç®¡çãã ãš ã ã æ° ã ãæ¹æ³ãå°å
¥ ã 㟠ã ãã Window
15â ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° Windows Server 2012 以éã®ã㌠㿠㻠㳠㿠ãŒã 㪠ã ãž ã³ã° ã¡ã¢ SR-IOV ã䜿çšããäºå®ã®ã ãå Žåã¯ã DCB æ©èœã®ã€ ã³ ã¹ ã ãŒã«ã¯æ§ã ã ã ãš ã ãå§ã ã ãŸãã DCB æ©èœã 〠㳠㹠ã ãŒã«ããå Žåã¯ã ä»®æ³ã¹ 〠ã ããããŒãž 㣠㧠Enable single-root I/O virtualization (SR-IOV) ïŒSingle-Root I/O Virtualization ïŒSR-IOVïŒ ãæå¹ã«ããïŒ ãéžæãã ãš ã åºæ¬ã¢ã ã ã¿ ãŒã¯åŒ·å¶ çã« DCB ç¶æ
ã«ãª ã ã ãš ã«æ³šæ ã ㊠ã ã ã ãã DCB ç¶æ
ã§ã¯ OS DCB èšå®ã ç¡èŠ ã ããŠã QCS ã ã ã® DCB èšå®ãæå¹ã«ãª ã ãŸãã ãã ã ã ãŠãŒã¶ãŒãèšå® ã ã Networking Priority ïŒã ã ã ã¯ãŒ 㯠åªå
é äœïŒ ã®å€ ïŒãŒã以å€ïŒ ã¯ã ãã ã QCS ã ã ã®ã ã®ã§ã 㣠㊠ãæå¹ã«ãª ã ãŸããã 255 BC005
16 SR-IOV æ¬ç« ã§ã¯ã Single- Root I/O Virtualization ïŒSR-IOVïŒ ã«ã€ããŠèª¬æ ã ãŸãã ï® æŠèŠ ï® SR-IOV ãæå¹åãã ï® 259 ããŒãžã® ãSR-IOV ãåäœå¯èœã§ã ã ã ãš ã®ç¢ºèªã ï® 260 ããŒãžã® ãSR-IOV ãš ã¹ ã ã¬ãŒãžæ©èœã ï® 261 ããŒãžã® ãSR-IOV 㚠㞠㣠ã³ããã± ã ã ã æŠèŠ ã ã ã ã¯ãŒ 㯠㳠㳠ã ã㌠㩠ãä»®æ³åãã ãš ããŠãŒã¶ãŒã¯ã ã ã ã¯ãŒãã³ ã° ã㌠ã ㊠㧠㢠㪠㜠ãŒã¹ ãçµ±å ã ã çµ±å ã ããã㌠ã ㊠㧠ã¢äžã§è€æ°ã®ä»®æ³ã ã· ã³ ãåæã«å®è¡ãã ã ãš ã㧠ã ãŸãã ä»®æ³åã« ã ã ã ãŠãŒã¶ãŒã¯ I/O å
±æã çµ±åã åé¢ã 移è¡ã®ã ã ãªå€æ§ãª æ©èœãå©çšã§ ãã ããŒã å ãš ã 㧠ã€ã«ãªãŒããŒãæ³å® ã ã ã ã ã 㞠㧠ã ã³ ã°ã« ã ã 管ç ãç°¡ç¥åãã ã ãš ã 㧠ã ãŸãã ä»®æ³åã䜿çšãã ãš ã ãã€ããŒãã€ã¶ãŒã®ãªãŒããŒã ã ã ãåå ã§ã ã ã ã© ãŒã ã³
16âSR-IOV SR-IOV ãæå¹åãã SR-IOV ãæå¹ã«ããã«ã¯ïŒ 1. QCC GUIã QCS CLIã Dell ã 㪠ã㌠ã UEFIã ãŸãã¯ã 㪠ã㌠ã CCM ãäœ¿çš ã ãŠã ã¢ã ã ã¿ ãŒäžã®æ©èœãæå¹ã« ã ãŸãã Windows QCC GUI ã䜿çšããå Žå ïŒ a. Explorer View ïŒãš 㯠㹠ã ã㌠㩠ã 㥠ãŒïŒ ã 〠㳠ã§ã ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒãéžæ ã ãŸãã Configuration ïŒèšå®ïŒ ã¿ ã ãéžæ ã ã SR-IOV Global Enable ïŒSR-IOV ã° ããŒãã«æå¹ïŒ ãéžæ ã ãŸãã b. SR-IOV VFs per PF ïŒSR-IOV ã® PF ãã ã VF ã®æ°ïŒ ã 㣠ãŒã« ã ã§ã 㢠ã ã ã¿ ãŒããµã㌠ã 㧠ã ãç©çæ©èœãã ã ã® SR-IOV ä»®æ³æ©èœ ïŒVFïŒ ã®æ° ã 0 ïœ 64 ã®ç¯å²ã§ 8 ã®åæ°ã§èšå® ã ãŸã ïŒã ã ã©ã« ã = 16ïŒã c.
16âSR-IOV SR-IOV ãæå¹åãã g.
16âSR-IOV SR-IOV ãåäœå¯èœã§ãã ã ãš ã®ç¢ºèª c. Virtual Switch Manager ã§ä»®æ³ã¢ã ã ã¿ ãŒãéžæ ã ã ã ãã²ãŒã· 㧠㳠ã 〠㳠㧠Hardware Acceleration ïŒã㌠ã ㊠㧠ã¢é«éåïŒ ãéžæ ã ãŸãã Single-root I/O virtualization ïŒã· ã³ ã°ã«ã«ãŒ ã I/O ä»®æ³åïŒ ã» ã¯ ã· ã§ ã³ ã§ã Enable SR-IOV ïŒSR-IOV ã®æå¹åïŒ ãéžæ ã ãŸãã SR-IOV 㯠ã ã ã§æå¹åããå¿
èŠãã ã ãŸãã vSwitch ã®äœæåŸã«æå¹åãã ã ãš ã¯ã§ ã 㟠ããã ESXïŒ a. bnx2x ã ã© ã€ãã 〠㳠㹠ã ãŒã« ã ãŸãã b. ESXi ã® lspci ã³ ã ã³ ã åºåã« Broadcom 10GNetXtreme NIC ã 㪠㹠ã ã ããŠãã ã ãš ãç¢ºèª ã ãŸãã c.
16âSR-IOV SR-IOV ãš ã¹ ã ã¬ãŒãžæ©èœ 3. ㊠㣠㳠ã ãŠã®äžéšã«ã ã Networking ïŒã ã ã ã¯ãŒãã³ ã°ïŒ ã¿ ã ã 㯠㪠ã 㯠ã ã ã¢ã ã ã¿ ãŒã¹ ã㌠㿠㹠ã衚瀺 ã ãŸãã VMware vSphere 6.0 U2 Web Client 㧠SR-IOV ã確èªããã«ã¯ã次ã®æé ãå®è¡ ããŸãã 1. Host ïŒãã¹ ã ïŒã Manage, Settings ïŒç®¡çã èšå®ïŒã Hardware ïŒã㌠ã ㊠㧠ã¢ïŒã PCI Devices ïŒPCI ãã〠ã¹ïŒ ãš éžæ ã ãŠã VF ãéåžžã® VMDirectPath ã ã〠㹠㚠ã ãŠè¡šç€º ã ãã ã ãš ãç¢ºèª ã ãŸãã 2.
16âSR-IOV SR-IOV 㚠㞠㣠ã³ããã± ã ã SR-IOV ãšãžã£ã³ããã±ãã ã¢ã ã ã¿ ãŒã®ä»®æ³æ©èœ ïŒVFïŒ ã§ SR-IOV ãæå¹å ã ããŠããå Žåã VF ãš Microsoft Synthetic ã¢ã ã ã¿ ãŒã®äž¡æ¹ã§å ã 㞠㣠ã³ã ãã± ã ã èšå®ãè¡ãããŠãã ã ãš ãç¢ºèª ã ãŸãã ã ã ãã®å€ã¯ã Windows Device Manager ã®è©³çŽ°ã ããã 㣠ãäœ¿çš ã ãŠèšå®ã ã ã ãš ã㧠ã ãŸãã å€ã«äžäžèŽãã ãå Žåã SR-IOV æ©èœã¯ Hyper-V ã®ã ã ã ã¯ãŒ 㯠㹠ã㌠㿠㹠ã§å£åç¶ æ
㚠衚瀺 ã ããŸãã 261 BC0054508-04 J
17 ä»æ§ ä»æ§ã ç¹æ§ã ããã³èŠä»¶ã¯æ¬¡ã® ãš ã ã ã§ãã ï® 10/100/1000BASE-T ããã³ 10GBASE-T ã±ãŒãã«ã®ä»æ§ ï® 265 ããŒãžã® ã〠㳠㿠ã 㧠ãŒã¹ä»æ§ã ï® 266 ããŒãžã® ãNIC ã®ç©çç¹æ§ã ï® 266 ããŒãžã® ãNIC ã®é»åèŠä»¶ã ï® 267 ããŒãžã® ãWake on LAN ã®é»åèŠä»¶ã ï® 268 ããŒãžã® ãç°å¢é¢ã®ä»æ§ã 10/100/1000BASE-T ããã³ 10GBASE-T ã±ãŒãã« ã®ä»æ§ è¡š 17-1.
17â ä»æ§ 10/100/1000BASE-T ã ãã³ 10GBASE-T ã±ãŒãã«ã®ä»æ§ è¡š 17-2. 10GBASE-T ã±ãŒãã«ã®ä»æ§ ããŒãã¿ã€ã ã³ãã¯ã¿ 10GBASE-T a RJ45 ã¡ãã£ã¢ æé·è·é¢ CAT-6 a UTP 131 ã 㣠㌠ã ïŒ40mïŒ CAT-6A a 328 ã 㣠㌠ã ïŒ100mïŒ UTP 10GBASE-T ã®ä¿¡å·éä¿¡ã«ã¯ã ISO/IEC 11801 ïŒ 2002 ããã³ ANSI/TIA/EIA-568-B ã§èŠå® ã ããŠããã CAT-6 ãŸã㯠CAT-6A ïŒCAT-6 ã®æ¡åŒµçïŒ ã®å¹³è¡¡ã±ãŒãã«é
ç·ã®ã 〠㹠ã ã㢠ïŒã ã 察ç·ïŒ ã 4 æ¬å¿
èŠã§ ãã NIC ãããã®ãµããŒã察象 SFP+ ã¢ãžã¥ãŒã« è¡š 17-3. BCM57710 ãµããŒã察象ã¢ãžã¥ãŒã« ã¢ãžã¥ãŒã« ã¿ã€ã å
㢠㞠㥠ãŒã« (SR) çŽæ¥æ¥ç¶ã±ãŒãã« ã¢ãžã¥ãŒã«ã®ãã³ã ã¢ãžã¥ãŒã«ã®éšåçªå· Finisar Corp.
17â ä»æ§ 10/100/1000BASE-T ã ãã³ 10GBASE-T ã±ãŒãã«ã®ä»æ§ è¡š 17-4. BCM57810 ãµããŒã察象ã¢ãžã¥ãŒã« ã¢ãžã¥ãŒã« ã¿ã€ã å
㢠㞠㥠ãŒã« (SR) çŽæ¥æ¥ç¶ã±ãŒãã« ã¢ãžã¥ãŒã«ã® ãã³ã ãã«ã®éšåçªå· ã¢ãžã¥ãŒã«ã®éšåçªå· W365M Avago AFBR-703SDZ-D1 N743D Finisar Corp. FTLX8571D3BCL R8H2F Intel Corp. AFBR-703SDZ-IN2 R8H2F Intel Corp. FTLX8571D3BCV-IT K585N Cisco-Molex Inc. 74752-9093 J564N Cisco-Molex Inc. 74752-9094 H603N Cisco-Molex Inc. 74752-9096 G840N Cisco-Molex Inc.
17â ä»æ§ 〠㳠㿠ã 㧠ãŒã¹ä»æ§ è¡š 17-5. BCM57840 ãµããŒã察象ã¢ãžã¥ãŒã« ã¢ãžã¥ãŒã« ã¿ã€ã å
㢠㞠㥠ãŒã« (SR) çŽæ¥æ¥ç¶ã±ãŒãã« ã¢ãžã¥ãŒã«ã® ãã³ã ãã«ã®éšåçªå· R8H2F ã¢ãžã¥ãŒã«ã®éšåçªå· Intel Corp. AFBR-703SDZ-IN2 Intel Corp. FTLX8571D3BCV-IT K585N Cisco-Molex Inc. 74752-9093 J564N Cisco-Molex Inc. 74752-9094 H603N Cisco-Molex Inc. 74752-9096 G840N Cisco-Molex Inc.
17â ä»æ§ NIC ã®ç©çç¹æ§ NIC ã®ç©çç¹æ§ è¡š 17-8. NIC ã®ç©çç¹æ§ NIC ã¿ã€ã NIC ã®é·ã NIC ã®å¹
BCM57810S PCI Express x8 ããŒã ã ã ã¡ 6.6 〠㳠ã ïŒ16.8cmïŒ 2.54 〠㳠ã ïŒ6.5cmïŒ ã€ã« NIC ã®é»åèŠä»¶ è¡š 17-9. BCM957810A1006G NIC é»åã®èŠä»¶ a ãªã³ã¯ NIC 12V æ¶è²»é»æµ ïŒAïŒ NIC 3.3V æ¶è²»é»æµ (A) NIC é»å (W) a 10G SFP 㢠㞠㥠ãŒã« 1.00 0.004 12.0 é»å (W) ã¯ã çŽæ¥èšç®ã§ã æ¶è²»é»æµã®ç·é (A) ã«é»å§ (V) ãä¹ ã ãå€ã§ãã ã¢ã ã ã¿ ãŒã®æ倧é»åæ¶è²»é㯠25W 以äžã§ãã è¡š 17-10. BCM957810A1008G NIC é»åã®èŠä»¶ NIC 12V æ¶è²»é»æµ ïŒAïŒ NIC 3.3V æ¶è²»é»æµ (A) NIC é»å (W) a ã¢ã€ ãã« ( 㪠ã³ã¯ãª ã) 0.9 0.004 11.0 100BASE-T 㪠㳠㯠1.
17â ä»æ§ Wake on LAN ã®é»åèŠä»¶ è¡š 17-11. BCM957840A4006G ã¡ã¶ãã³ ã«ãŒãé»åã®èŠä»¶ é»ååèš (12V ããã³ ãªã³ã¯ 3.3VAUX) (W) a 10G SFP+ 12.0 ã¹ ã¿ ã³ãã€ã WoL æå¹ 5.0 ã¹ ã¿ ã³ãã€ã WoL ç¡å¹ 0.5 a é»å (W) ã¯ã çŽæ¥èšç®ã§ã æ¶è²»é»æµã®ç·é (A) ã«é»å§ (V) ãä¹ ã ãå€ã§ãã ã¢ã ã ã¿ ãŒã®æ倧é»åæ¶è²»é㯠25W 以äžã§ãã è¡š 17-12. BCM957840A4007G ã¡ã¶ãã³ ã«ãŒãé»åã®èŠä»¶ é»ååèš (3.3V) (W) a ãªã³ã¯ 10G KR 〠㳠㿠ã 㧠ãŒã¹ 10.0 WoL æå¹ 3.5 a é»å (W) ã¯ã çŽæ¥èšç®ã§ã æ¶è²»é»æµã®ç·é (A) ã«é»å§ (V) ãä¹ ã ãå€ã§ãã ã¢ã ã ã¿ ãŒã®æ倧é»åæ¶è²»é㯠25W 以äžã§ãã Wake on LAN ã®é»åèŠä»¶ WoL ã®å
¬ç§°é»å ï® BCM957810A1006G ïŒ 9.0W ï® BCM957810A1008G ïŒ 16.
17â ä»æ§ ç°å¢é¢ã®ä»æ§ ç°å¢é¢ã®ä»æ§ è¡š 17-13. BCM5709 ããã³ BCM5716 ç°å¢ä»æ§ ãã©ã¡ãŒã¿ æ¡ä»¶ åäœæã®æž©åºŠ 32°F ïœ 131°F ïŒ0°C ïœ 55°CïŒ ç©ºæ°æµã®èŠä»¶ (LFM) 0 ä¿ç®¡æã®æž©åºŠ â40°F ïœ 149°F ïŒâ40°C ïœ 65°CïŒ ä¿ç®¡æã®æ¹¿åºŠ 5% ïœ 95% ( åçž® ) æ¯å ãš è¡æ IEC 68ã FCC Part 68.302ã NSTAã 1A éé»æ° / é»ç£æ°ã®åœ±é¿ EN 61000-4-2ã EN 55024 è¡š 17-14. BCM957810A1006G ç°å¢ä»æ§ ãã©ã¡ãŒã¿ æ¡ä»¶ åäœæã®æž©åºŠ 32°F ïœ 131°F ïŒ0°C ïœ 55°CïŒ ç©ºæ°æµã®èŠä»¶ (LFM) 100 ä¿ç®¡æã®æž©åºŠ â40°F ïœ 149°F ïŒâ40°C ïœ 65°CïŒ ä¿ç®¡æã®æ¹¿åºŠ 5% ïœ 95% ( åçž® ) æ¯å ãš è¡æ IEC 68ã FCC Part 68.302ã NSTAã 1A éé»æ° / é»ç£æ°ã®åœ±é¿ IEC 801-2ã 3ã 4ã 5 è¡š 17-15.
17â ä»æ§ ç°å¢é¢ã®ä»æ§ è¡š 17-16. BCM957840A4007G ç°å¢ä»æ§ ãã©ã¡ãŒã¿ æ¡ä»¶ åäœæã®æž©åºŠ 32°F ïœ 131°F ïŒ0°C ïœ 65°CïŒ ç©ºæ°æµã®èŠä»¶ (LFM) 200 ä¿ç®¡æã®æž©åºŠ â40°F ïœ 149°F ïŒâ40°C ïœ 65°CïŒ ä¿ç®¡æã®æ¹¿åºŠ 5% ïœ 95% ( åçž® ) æ¯å ãš è¡æ IEC 68ã FCC Part 68.
18 æ³èŠå¶æ
å ± æ¬ç« ã§ã¯ã 以äžã®æ³èŠå¶æ
å ±ãå ã äžããŸãã ï® è£œåå®å
šæ§ ï® AS/NZS ïŒC-TickïŒ ï® 271 ããŒãžã® ãFCC éåã ï® 273 ããŒãžã® ãVCCI éåã ï® 278 ããŒãžã® ãCE ã®éåã ï® 279 ããŒãžã® ãã« ããã®æ³èŠå¶ã«é¢ããæ
å ± ïŒã« ããã®ã¿ïŒã ï® 281 ããŒãžã® ãKorea Communications Commission (KCC) ã®éå ( éåœã®ã¿ )ã ï® 284 ããŒãžã® ãBSMIã ï® 284 ããŒãžã® ãBCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ã ãã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿããèªå®ã 補åå®å
šæ§ ! èŠå ã¢ã ã ã¿ ãŒã㌠ã ㊠㧠㢠ãå ã ä»ããåã«ã ã³ ã³ ã 㥠㌠㿠ã ããã³æ¥ç¶ ã ããŠã ããã¹ãŠã®ãã〠㹠ïŒã¢ ã ã¿ ã ã 㪠㳠㿠ã ã ãã³å€ä»ã ã³ ã³ããŒã ã³ ã 㪠ã©ïŒ ã® é»æºãå ã ãŸãã BCM57xx ããã³ BCM57xxx ã¢
18â æ³èŠå¶æ
å ± FCC éå FCC éå FCCãã¯ã©ã¹ B QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® ï® BCM95708A0804F BCM95709A0907G BCM95709A0906G BCM957810A1008G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejoã CA 92656 USA åœæ©åšã¯ã FCC ( ç±³é£éŠéä¿¡å§å¡äŒ ) æšæºã®ç¬¬ 15 éšã«æºæ ã ãŠã ã ã ãã®åäœã¯ä»¥äž ã® 2 ã€ã®æ¡ä»¶ã«æº ã ãŠããŸãã ïŒ1ïŒ åœè£
眮ã¯æ害ãªå¹²æžãèµ· ã ã ãªãã ïŒ2ïŒ åœæ©åšã¯ã äžèŠãªåäœã ã ã ã ãå¯èœæ§ã®ã ãå¹²æž ã å«ãã ã ã ããå¹²æžã蚱容ããã åœæ©åšã¯ã FCC æšæºã®ç¬¬ 15 éšã« ã ã 㯠㩠㹠B ããž ã¿ ã« ãã〠ã¹ã®å¶éã«æº ã ã ã ã® ã§ã ã ã ãš ãè©Šéšã« ã ã æ ã ãã«ãª 㣠ãŠããŸãã ã ã®å¶éã¯ã äœå®
å°ç°å¢ã§ã®æ害ãªå ä¿¡å¹²æžã«å¯Ÿ ã ãŠé©æ£ãª
18â æ³èŠå¶æ
å ± FCC éå FCCãã¯ã©ã¹ A QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ïŒ ï® BCM95709A0916G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ïŒ ï® ï® ï® ï® ï® ï® ï® ï® BCM957800 BCM957710A1022G BCM957710A1021G BCM957711A1113G BCM957711A1102G BCM957810A1006G BCM957840A4006G BCM957840A4007G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejoã CA 92656 USA ã ã®è£
眮㯠FCC ïŒç±³åœé£éŠéä¿¡å§å¡äŒïŒ èŠåã®ã㌠ã 15 ã«é©å ã ãŠããŸãã ãã®åäœ ã¯ä»¥äžã® 2 ã€ã®æ¡ä»¶ã«æº ã ãŠããŸãã ïŒ1ïŒ åœè£
眮ã¯æ害ãªå¹²æžãèµ· ã ã ãªãã ïŒ2ïŒ åœæ© åšã¯ã äžèŠãªåäœã ã ã ã ãå¯èœæ§ã®ã ã
18â æ³èŠå¶æ
å ± VCCI éå ã¡ã¢ QLogic 瀟ã®èš±å¯ãåŸãã«æ©åšã«å€æŽãæ¹è¯ãå ããå Žåã¯ã åœæ©åšã®å©çšæš©éã ç¡å¹ ãš ã ããŸãã VCCI éå 次ã®è¡šã¯ã Dell åã QLogic BCM57xx ããã³ BCM57xxx ã¢ã ã ã¿ ãŒã® VCCI éåã® ç©çä»æ§ã瀺 ã ãŠããŸãã è¡š 18-1. QLogic 57800S 1GB ããã³ 10GBASE-T ã©ãã¯ãããã¯ãŒã¯ ããŒã¿ãŒã«ãŒãã®ç©ççç¹æ§ é
ç® èª¬æ ã㌠ã ã 㥠ã¢ã« 1Gbps 〠ãŒãµã ã ã ããã³ã 㥠ã¢ã« 10Gbps 〠ãŒãµ ãã ã ã ã© ãŒã ã 㡠㯠㿠㌠ã ã ã ã¯ãŒ 㯠ã ㌠㿠㌠㫠㌠ã 3.66 〠㳠ã Ã2.93 〠㳠ã ïŒ92.9mmÃ74.
18â æ³èŠå¶æ
å ± VCCI éå è¡š 18-2. QLogic 57800S ã¯ã¢ãã RJ-45ãSFP+ããŸãã¯çŽæ¥æ¥ç¶ã©ã㯠ãããã¯ãŒã¯ããŒã¿ãŒã«ãŒãã®ç©ççç¹æ§ ( ç¶ã ) é
ç® èª¬æ 2 ã㌠ã SFP+ ïŒ10GbEïŒ ã³ã㯠㿠2 ã㌠ã RJ45 ïŒ1GbEïŒ RoHSã FCC Aã ULã CEã VCCIã BSMIã C-Tickã KCCã TUVã ããã³ ICES-003 èªå® è¡š 18-3. QLogic 57810S ãã¥ã¢ã« 10GBASE-T PCI-e ã«ãŒãã®ç©ççç¹æ§ é
ç® èª¬æ ã㌠ã ã 㥠ã¢ã« 10Gbps BASE-T 〠ãŒãµã ã ã ã㌠ã ã ã© ãŒã ã 㡠㯠㿠㌠PCI Express ã®çãããŒã ã ã ã¡ ã€ã«ã« ㌠ã 6.60 〠㳠ã Ã2.71 〠㳠ã ïŒ167.64mmÃ68.
18â æ³èŠå¶æ
å ± VCCI éå è¡š 18-4. QLogic 57810S ãã¥ã¢ã« SFP+ ãŸãã¯çŽæ¥æ¥ç¶ PCIe ã®ç©ççç¹æ§ ( ç¶ã ) é
ç® èª¬æ RoHSã FCC Aã ULã CEã VCCIã BSMIã C-Tickã KCCã TUVã ããã³ ICES-003 èªå® è¡š 18-5. QLogic 57810S-K ãã¥ã¢ã« KR ãã¬ãŒãã¡ã¶ãã³ã¢ããã¿ãŒã® ç©ççç¹æ§ é
ç® èª¬æ ã㌠ã ã 㥠ã¢ã« 10Gbps Ethernet ã ã© ãŒã ã 㡠㯠㿠㌠㡠ã¶ã ã³ ã¢ãã 㿠㌠3.13 〠㳠ã Ã2.85 〠㳠ã ïŒ79.5mmÃ72.4mmïŒ ãµã㌠ã ã ãããµãŒ ã㌠第 13 äžä»£ ïŒ M630 èªå® RoHSã FCC Aã ULã CEã VCCIã C-Tickã KCCã TUVã ããã³ ICES-003 第 12 äžä»£ ïŒ M420ã M520ã M620ã ããã³ M820 è¡š 18-6.
18â æ³èŠå¶æ
å ± VCCI éå è¡š 18-7. QLogic 57840S ã¯ã¢ãã 10GbE SFP+ ãŸãã¯çŽæ¥æ¥ç¶ã©ã㯠ãããã¯ãŒã¯ããŒã¿ãŒã«ãŒãã®ç©ççç¹æ§ é
ç® èª¬æ ã㌠ã ã 㥠ã¢ã« 10Gbps Ethernet ã ã© ãŒã ã 㡠㯠㿠㌠PCI Express ã®çãããŒã ã ã ã¡ ã€ã«ã« ㌠ã 6.60 〠㳠ã Ã2.71 〠㳠ã ïŒ67.64mmÃ68.91mmïŒ ãµã㌠ã ã ãããµãŒ ã㌠第 13 äžä»£ ïŒ R630ã R730ã R730xdã ããã³ T630 èªå® RoHSã FCC Aã ULã CEã VCCIã BSMIã C-Tickã KCCã TUVã ããã³ ICES-003 第 12 äžä»£ ïŒ R320ã R420ã R520ã R620ã R720ã R720xdã R820ã T420ã ããã³ T620 è¡š 18-8.
18â æ³èŠå¶æ
å ± VCCI éå åœæ©åšã¯ã VCCI (Voluntary Control Council for Information Technology Equipmentã æ
å ±åŠçè£
眮çé»æ³¢é害èªäž»èŠå¶åè°äŒ ) ã®åºæºã«åºã¥ ã 㯠㩠㹠B ã®æ¡ä»¶ ãæºã ã ãŠããŸãã 家åºç°å¢ã§ã ç¡ç· ( ã© ãžãª ) ãã 㬠ãã®åä¿¡æ©ã®è¿ ã ã§åœæ©åšã䜿 çšãã ãš ã ç¡ç·å¹²æžãèµ· ã ãå Žåãã ã ãŸãã åœæ©åšã¯åæ±èª¬ææžã«åŸ 㣠ãŠã èšçœ® ã» å© çš ã ㊠ã ã ã ãã 泚æ åšæ³¢æ°ã 59 ïœ 66 MHz ã®äŒå°ç¡ç·åšæ³¢æ°ãšãã«ã®ãŒãååšããå Žåã«ã¯ã åœæ© åšã«é害ãçºçããå¯èœæ§ãã ã ãŸããã RF ã®ãšãã«ã®ãŒçºçæºãå ã é€ããã ãš éåžžåäœã«æ» ã ãŸãã VCCI ã¯ã©ã¹ B éå ( æ¥æ¬ ) VCCIãã¯ã©ã¹ A QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® BCM95709A0916G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬
18â æ³èŠå¶æ
å ± CE ã®éå VCCI ã¯ã©ã¹ A éå ( æ¥æ¬ ) CE ã®éå QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® ï® ï® BCM95708A0804F BCM95709A0907G BCM95709A0906G BCM95709A0916G BCM957810A1008G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® ï® ï® ï® BCM957710A1022G BCM957710A1021G BCM957711A1113G BCM957711A1102G BCM957840A4006G BCM957840A4007G ã ã®è£œåã¯ã 2006/95/EC ïŒäœé»å§æ什ïŒã 2004/108/EC ïŒEMC æ什ïŒã ã ãã³æ¬§å·é£ å ïŒEUïŒ ã®ä¿®æ£ã«æºæ ã ãŠã ã ã ãš ãç¢ºèª ã ããŠããŸãã åè¿°ã®æ什ããã³åºæºã«åŸ 㣠ã ãé©å宣èšã ãè¡ããã QLogic Corporation,
18â æ³èŠå¶æ
å ± ã« ããã®æ³èŠå¶ã«é¢ããæ
å ± ïŒã« ããã®ã¿ïŒ ã«ããã®æ³èŠå¶ã«é¢ããæ
å ±ïŒã«ããã®ã¿ïŒ ã«ããç£æ¥çãã¯ã©ã¹ B QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM95708A0804F BCM95709A0907G BCM95709A0906G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejoã CA 92656 USA åœ ã¯ ã© ã¹ B ããž ã¿ ã«æ©åšã¯ Canadian ICES-003 ã«æºæ ã ãŠããŸãã éå ïŒ ã« ããç£æ¥çã®èŠå¶ã« ã ã ã QLogic ã« ã ãæ確ãªæ¿èªãåŸãã«å€é ãæ¹é ãå ããå Žåã«ã¯ã åœæ©åšã®å©çšæš©éãç¡å¹ã«ãª ã ãŸãã ã«ããç£æ¥çãã¯ã©ã¹ A QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® BCM95709A0916G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã
18â æ³èŠå¶æ
å ± ã« ããã®æ³èŠå¶ã«é¢ããæ
å ± ïŒã« ããã®ã¿ïŒ Industry Canada, classe B QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM95708A0804F BCM95709A0907G BCM95709A0906G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejo, CA 92656 USA Cet appareil numérique de la classe B est conforme à la norme canadienne ICES-003.
18â æ³èŠå¶æ
å ± Korea Communications Commission (KCC) ã®éå ( éåœã®ã¿ ) Korea Communications Commission (KCC) ã® éå ( éåœã®ã¿ ) B ã¯ã©ã¹ ããã€ã¹ QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM95708A0804F BCM95709A0907G BCM95709A0906G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejoã CA 92656 USA 281 BC0054508-04 J
18â æ³èŠå¶æ
å ± Korea Communications Commission (KCC) ã®éå ( éåœã®ã¿ ) åœæ©åšã¯ã éäºæ¥çš ãš ã ãŠæ¿èªãåããŠãã ãã®ã§ã ã ã äœå®
å°å㪠ã©ã®ã ã ããç°å¢ 㧠ãå©çšããã ããŸãã A ã¯ã©ã¹ããã€ã¹ QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® BCM95709A0916G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® ï® ï® ï® ï® BCM957710A1022G BCM957710A1021G BCM957711A1113G BCM957711A1102G BCM957810A1008G BCM957840A4006G BCM957840A4007G QLogic Corporation 26650 Aliso Viejo Parkway Aliso Viejoã CA 92656 USA 282 BC0054508-04 J
18â æ³èŠå¶æ
å ± Korea Communications Commission (KCC) ã®éå ( éåœã®ã¿ ) 283 BC0054508-04 J
18â æ³èŠå¶æ
å ± BSMI BSMI BCM95709SA0908GãBCM957710A1023G ïŒE02D001ïŒ ãããã³ BCM957711A1123G ïŒE03D001ïŒã«å¯Ÿããèªå® æ¬é
㯠Dell ã«ä»£ã 㣠ãŠèšèŒ ã ãã ãã®ã§ã QLogic 㯠ã ã®æ
å ±ã®æ£åœæ§ãŸãã¯æ£ç¢ºæ§ã« 察 ã ãŠè²¬ä»»ãè² ããŸããã BCM95709SA0908G QLogic BCM57xx ããã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ã㌠㩠ã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ã㌠㩠ã¯ã 以äžã®æ³èŠå¶ã«å¯Ÿããæºæ ã«ã€ããŠã èªå®ãåããŠããŸãã ï® ï® FCCã 㯠㩠㹠A ( ç±³åœ ) VCCIã 㯠㩠㹠A ( æ¥æ¬ ) 284 BC0054508-04 J
18â æ³èŠå¶æ
å ± BCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿã ï® ï® ã« ããã®æ³èŠå¶ã«é¢ããæ
å ±ã 㯠㩠㹠A ïŒã« ããïŒ Korea Communications Commission (KCC) ã®éå ( éåœ ) FCC éå FCCãã¯ã©ã¹ A QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® BCM95709SA0908G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM957710A1023G BCM957711A1123G (E03D001) E02D001 Dell Inc.
18â æ³èŠå¶æ
å ± BCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿã ã¡ã¢ Dell Inc. ã®èš±å¯ãåŸãã«æ©åšã«å€æŽãæ¹è¯ãå ããå Žåã¯ã åœæ©åšã®å©çšæš©éã ç¡å¹ ãš ã ããŸãã VCCI éå ã¯ã©ã¹ A QLogic BCM57xx ã ãã³ BCM57xxx ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® BCM95709SA0908G QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM957710A1023G BCM957711A1123G (E03D001) E02D001 Dell Inc.
18â æ³èŠå¶æ
å ± BCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿã ï® ï® BCM957711A1123G (E03D001) E02D001 Dell Inc. Worldwide Regulatory Compliance, Engineering and Environmental Affairs One Dell Way PS4-30 Round Rock, Texas 78682, USA 512-338-4400 ã ã®è£œåã¯ã 2006/95/EC ïŒäœé»å§æ什ïŒã 2004/108/EC ïŒEMC æ什ïŒã ã ãã³æ¬§å·é£ å ïŒEUïŒ ã®ä¿®æ£ã«æºæ ã ãŠã ã ã ãš ãç¢ºèª ã ããŠããŸãã åè¿°ã®æ什ããã³åºæºã«åŸ 㣠ã ãé©å宣èšã ãè¡ããã Dell Inc.
18â æ³èŠå¶æ
å ± BCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿã QLogic BCM57xx ã ãã³ BCM57xxx 10 ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã³ ã³ ã ããŒ ã© ï® ï® ï® BCM957710A1023G BCM957711A1123G (E03D001) E02D001 Dell Inc. Worldwide Regulatory Compliance, Engineering and Environmental Affairs One Dell Way PS4-30 Round Rock, Texas 78682, USA 512-338-4400 Cet appareil numérique de classe A est conforme à la norme canadienne ICES-003.
18â æ³èŠå¶æ
å ± BCM95709SA0908Gã BCM957710A1023G ïŒE02D001ïŒã ããã³ BCM957711A1123G ïŒE03D001ïŒ ã«å¯Ÿã 289 BC0054508-04 J
19 ãã©ãã«ã·ã¥ãŒãã£ã³ã° ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã® ã ã ã 㯠ã«ã¯ã 以äžãå«ãŸããŸãã ï® ã㌠ã ㊠㧠ã¢ã®èšºæ ï® 292 ããŒãžã® ãã㌠ã ã® LED ã®ç¢ºèªã ï® 292 ããŒãžã® ã ã ã© ãã«ã· 㥠ãŒã 㣠㳠ã°ã 㧠ã 㯠㪠㹠ã ã ï® 293 ããŒãžã® ãçŸè¡ã® ã ã© ã€ããã㌠ã ã ããŠãããã© ã ãã®ã 㧠ã ã¯ã ï® 294 ããŒãžã® ãã±ãŒãã«é·ã®ã ã¹ ã ã®å®è¡ã ï® 294 ããŒãžã® ãã ã ã ã¯ãŒ 㯠æ¥ç¶æ§ã®ã ã¹ ã ã ï® 295 ããŒãžã® ãHyper-V ãäœ¿çš ã ã Microsoft Virtualizationã ï® 300 ããŒãžã® ãQLogic BCM57xx ããã³ BCM57xxx ãã〠㹠ã ã© ã€ãã®åé€ã ï® 300 ããŒãžã® ãWindows ãªã ã¬ãŒã 㣠㳠㰠㷠㹠ãã ã 㢠ã ã㰠㬠㌠ã ããã ï® 301 ããŒãžã® ãQLogic ã㌠ã ãšãŒãž 㧠㳠ã ã ï® 301 ããŒãžã® ãQLASPã ï® 3
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ã㌠ã ㊠㧠ã¢ã®èšºæ QCS 蚺æãã¹ãã®å€±æ QCS ã§èšºæã ã¹ ã ãå®è¡ ã ãŠããŠã 次ã®ã ã¹ ã ã®ããããã倱æ ã ãå Žåã ã· ã¹ ãã ã«å ã ä»ãã NIC ãŸã㯠LOM ã«ã㌠ã ㊠㧠ã¢ã®åé¡ãã ãå¯èœæ§ãã ã ãŸãã ï® ï® ï® ï® ï® ï® ï® ï® ï® å¶åŸ¡ã¬ ãž ã¹ ã¿ ã ã¹ ã MII 㬠㞠㹠㿠EEPROM å
éš ã¡ ã¢ ãª ã ã ãäž CPU å² ã 蟌㿠ã«ãŒãã ã 㯠- MAC ã«ãŒãã ã 㯠- PHY LED ã ã¹ ã 倱æã®è§£æ±ºã«åœ¹ç«ã€ãã©ãã«ã·ã¥ãŒãã£ã³ã°ã®æé ã¯ã以äžã®ãšããã§ãã 1. 倱æ ã ããã〠㹠ãå ã å€ ã ã ã¹ ã ã ã ã«å床å ã ä»ããŠã 㫠㌠ã ãã¹ ã ã ã å
š äœã«ãã 㣠㊠ã ã£ã ã ãš åºå® ã ããŠã ã ã ãš ãç¢ºèª ã ãŸãã 2. ã ã¹ ã ãåå®è¡ ã ãŸãã 3.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ã㌠ã ã® LED ã®ç¢ºèª ããŒãã® LED ã®ç¢ºèª ã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠ã®ç¶æ
ã確èªãã ã«ã¯ã 6 ããŒãžã® ãã ã ã ã¯ãŒ 㯠㪠㳠㯠㚠㢠㯠ã 㣠ã ã 㣠ã®ç¶æ
ã®éç¥ã ãåç
§ ã ㊠ã ã ã ãã ãã©ãã«ã·ã¥ãŒãã£ã³ã°ãã§ãã¯ãªã¹ã 泚æ ãµãŒããŒã®ã 㣠ã ã ã ã ãéã㊠ã¢ã ã ã¿ ãŒã®å ã ä»ããŸãã¯å ã å€ ã ãè¡ ã å ã«ã 19 ããŒãžã® ãå®å
šäžã®æ³šæã ã ãèªã¿ ã ã ã ãã 以äžã®ã 㧠ã 㯠㪠㹠ã ã§ã QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒã®å ã ä» ãæã® ã ã© ãã«ãã ã· ã¹ ãã ã§ã®å®è¡æã® ã ã© ãã«ã解決ãã ããã®æšå¥šã¢ 㯠㷠㧠㳠ã ç¢ºèª ã ㊠ã ã ã ãã ï® ã±ãŒãã« ãš æ¥ç¶ããã¹ãŠç¹æ€ ã ãŸãã ã ã ã ã¯ãŒ 㯠ã¢ãã 㿠㌠㚠㹠〠ã ãã®ã±ãŒ ãã«æ¥ç¶ãæ£ ã ã æ¥ç¶ ã ããŠã ã ã ãš ãç¢ºèª ã ãŸãã ã±ãŒãã«é·ãå®æ Œ
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° çŸè¡ã® ã ã© ã€ããã㌠ã ã ããŠãããã© ã ãã®ã 㧠ã 㯠çŸè¡ã®ãã©ã€ããããŒããããŠãããã©ããã®ãã§ã㯠çŸè¡ã® ã ã© ã€ããã㌠ã ã ããŠãããã© ã ãã確èªãã ããã«ã ã䜿ãã®ãªã ã¬ãŒã 㣠㳠ã°ã· ã¹ ãã ã®é©åãªæé ã«åŸ 㣠㊠ã ã ã ãã Windows ã¢ã ã ã¿ ãŒã 㪠㳠㯠㹠ã㌠㿠ã¹ã ããã³ã ã ã ã¯ãŒ ã¯æ¥ç¶æ§ã«é¢ããéèŠãªæ
å ±ãç¢ºèª ãã ã«ã¯ã QCC GUI 㪠㳠㩠〠ã³ãã«ã ãåç
§ ã ㊠ã ã ã ãã Linux bnx2.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ã±ãŒãã«é·ã®ã ã¹ ã ã®å®è¡ åºåäŸã¯æ¬¡ã® ãš ã ã ã§ãã driver: bnx2x version: 1.78.07 firmware-version: bc 7.8.6 bus-info: 0000:04:00.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Hyper-V ãäœ¿çš ã ã Microsoft Virtualization Linux 〠ãŒãµã ã ã 〠㳠㿠ã 㧠ãŒã¹ãç«ã¡äžã 㣠ãŠãããã© ã ãã確èªãã ã«ã¯ãifconfig ã³ ã ã³ ã ãçºè¡ ã ãŠã 〠ãŒãµã ã ã 〠㳠㿠ã 㧠ãŒã¹ã®ã¹ ã㌠㿠㹠ã ã 㧠ã 㯠ã ãŸãã netstat -i ãäœ¿çš ã ㊠〠ãŒãµã ã ã 〠㳠㿠ã 㧠ãŒã¹ã®çµ±èšæ
å ±ã確èªãã ã ãš ã㧠ã ãŸãã ifconfig ãš netstat ã®æ
å ±ã«ã€ããŠã¯ã第 7 ç« Linux ã ã© ã€ã 㜠ã ã ㊠㧠㢠ãåç
§ ã ㊠ã ã ã ãã ã ã ã ã¯ãŒ ã¯äžã® IP ãã¹ ã ã ping ã ãŠã æ¥ç¶ãç¢ºç« ã ããŠãã ã ãš ãæ€èšŒ ã ãŸãã ã³ ã ã³ ã 㩠〠ã³ã ãã ping ã³ ã ã³ ã ãçºè¡ ã ã ENTER ããŒãæŒ ã ãŸãã 衚瀺 ã ãã ping çµ±èšã¯ã ã ã ã ã¯ãŒ 㯠æ¥ç¶ãæ©èœ ã ãŠã ããã© ã ãã瀺
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Hyper-V ãäœ¿çš ã ã Microsoft Virtualization è¡š 19-1.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Hyper-V ãäœ¿çš ã ã Microsoft Virtualization Windows Server 2008 R2 ããã³ 2012 Hyper-V ã· ã¹ ãã äžã§ BCM57xx ããã³ BCM57xxx ã ã ã ã¯ãŒ 㯠ã¢ã ã ã¿ ãŒãèšå®ã ãå Žåã¯ã 以äžã®ç¹ã«æ³šæ ã ㊠ã ã ã ãã ï® ä»®æ³ã ã ã ã¯ãŒ 㯠ã«ã〠㳠ã ã ãã ã¢ã ã ã¿ ãŒã®å Žåã ã ã© ã€ãã®è©³çŽ°èšå®ã ã ãã 㣠ã ã VLAN ã¿ ã®ã³ ã° ãèšå® ã ãŠã¯ãããŸããã ã ã© ã€ãã§ã¯ãª ã ã Hyper-V ãåç¬ã§ VLAN ã¿ ã®ã³ ã° ã管ç ã ãŸãã ï® Hyper-V ã« ã 㣠ãŠèšå® ã ãã Locally Administered Address ïŒLAAã ã㌠ã«ã« 管ç㢠ã 㬠ã¹ïŒ ã¯ã ã¢ã ã ã¿ ãŒã®è©³çŽ°èšå®ã ããã 㣠ã§èšå® ã ãã㢠ã 㬠㹠ã ã ã åªå
ã ããŸãã ï® ã²ã¹ ã OS ã® LSO ããã³ CO æ©èœã¯ã ã ã ã ã¯ãŒ 㯠ã¢ãã ã¿ ã ã
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Hyper-V ãäœ¿çš ã ã Microsoft Virtualization è¡š 19-2.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Hyper-V ãäœ¿çš ã ã Microsoft Virtualization ï® ãã¹ ã ïŒèŠªããŒã 㣠㷠㧠ã³ïŒ ãš ã²ã¹ ã ïŒåããŒã 㣠㷠㧠ã³ïŒ ã®äž¡æ¹ã§ QLASP ããŒã å 㜠ã ã ㊠㧠㢠ã䜿 㣠㊠VLAN ã¿ ã®ã³ ã° ãåé¡ãª ã å®è¡ãã ã«ã¯ã ã¿ ã®ã³ ã°çšã«ããŒã ãæ§æããå¿
èŠãã ã ãŸãã åäžã¢ã ã ã¿ ãŒã§ã® VLAN ã¿ ã®ã³ ã° ãš ã¯ç°ãª ã ã QLASP 㜠ã ã ㊠㧠ã¢ã®äœ¿çšæã«ã¯ã ã¿ ã®ã³ ã°ã¯ Hyper-V ã§ã¯ç®¡ç ã ããŸããã ï® ããŒã ãå€æŽãŸãã¯åé€ãã ã«ã¯ã 次ã®ã ã ã« Hyper-V Manager ãäœ¿çš ã ãŸãã 1. ããŒã å
ã§ããããã® VNIC ã䜿çšãããã¹ãŠã®ã²ã¹ ã OS ã ã ã ããŒã ã®ã〠ã³ã 㣠㳠㰠ãåé€ ã ãŸãã 2. èšå®ãå€æŽ ã ãŸãã 3.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° QLogic BCM57xx ããã³ BCM57xxx ãã〠㹠ã ã© ã€ãã®åé€ ã®äœæïŒ ããŒãž ãŸã㯠Edit Team ïŒããŒã ã®ç·šéïŒ ããŒãž ã§ã ã ã®ã ããã 㣠ã æå¹ã« ã ãŸãã 2. 次ã®æé ã«åŸ 㣠ãŠã å¿
èŠãª 㬠㞠㹠ã 㪠㚠㳠ã 㪠ã Windows ã«è¿œå ã ãŸãã http://technet.microsoft.com/en-us/library/gg162696%28v=ws.10%29.aspx 3. VMQ ãæå¹ã«ãã ããŒã ã¡ ã³ããŒã ãš ã«ã 次ã®ã¬ ãž ã¹ ã 㪠㚠㳠ã 㪠ãå€æŽ ã ãŠã äžæã®ã€ ã³ ã¹ ã¿ ã³ ã¹çªå· ïŒæ¬¡ã®äŸã§ã¯ 0026ïŒ ãèšå® ã ãŸãã [HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Class\ {4D36E972-E325-11CE-BFC1-08002BE10318}\0026] "*RssOrVmqPreference"="1" QLogic BCM57xx ããã³ BC
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° QLogic ã㌠ã ãšãŒãž 㧠㳠ã 3. Windows 㢠ã ãã° ã¬ãŒ ã ãå®è¡ ã ãŸãã 4.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° QLASP ãã©ãã« ïŒ 802.3ad ããŒã ãå«ãã· ã¹ ãã äžã§ã ã· ã¹ ãã 〠ãã³ ã ã ã°ã« Netlogon ãµãŒã ã¹ã®å€±æãèšé² ã ãã èµ·åæã« ã 㡠〠㳠㳠㳠ã ã㌠㩠㚠ã®éä¿¡ã㧠ã 㪠ã 㪠ãã ãœãªã¥ãŒã·ã§ã³ ïŒ Microsoft ãµã㌠ã æè¡æ
å ±ææž 326152 ïŒ http://support.microsoft.com/kb/326152/en-usïŒ ã« ã ã ãš ã ã®ã¬ ã ã ã 〠ãŒãµã ã ã ã¢ã ã ã¿ ãŒã§ã¯ã ã ã© ã€ããåæåãå®è¡ ã ãŠã ã ã ã¯ãŒ 㯠〠㳠ã ã© ã¹ ã 㩠㯠ã 㣠㚠㮠㪠㳠㯠ã ã㎠㷠ãšãŒã· 㧠ã³ãã ãš ã 㫠㪠㳠ã¯ãäžå®å®ã«ãª ã ããã ã 㡠〠㳠㳠㳠ã ã㌠㩠㚠ã®æ¥ç¶ã§åé¡ãçºçããå¯èœæ§ãã ã ãŸãã GbE ã¢ã ã ã¿ ãŒã 802.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° Linux Linux ãã©ãã« ïŒ SFP+ ã ããŒå¶åŸ¡ã«å¯Ÿå¿ ã ã BCM57xx ããã³ BCM57xxx ãã〠ã¹ãã Rx/Tx Enable ïŒRx/Tx æå¹ïŒ ã§ã¯ãª ã ã ã ã© ã« ã 㧠Off ïŒãª ã ïŒ ã«ãª ãã ãœãªã¥ãŒã·ã§ã³ ïŒ SFP+ ãã〠ã¹ã¯ã ã ããŒå¶åŸ¡ã®èªåã㎠㷠ãšãŒã· 㧠㳠ããµã㌠ã ã ãªãããã ããŒãž 㧠㳠1.6.x 以éã§ã¯ã ã ããŒå¶åŸ¡ã®ã ã ã© ã« ã èšå®ã Rx Off and Tx Off ïŒRx 㪠ã ããã³ Tx 㪠ã ïŒ ã«å€æŽ ã ã㟠ã ãã ãã©ãã« ïŒ 2.6.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° 〠ãŒãµã ã ã çµç±ã®ã« ãŒãã«ãã ã ã° iSCSI ã® ã㌠㜠ã 㪠ã 㣠ã 1 ã€ã®ã㌠ã ã®æåã®ããŒã 㣠㷠㧠㳠ã§æå¹ãªéã«ã FCoE ã㌠㜠ã 㪠ã 㣠ãå¥ã®ã㌠ã ã®æåã®ããŒã 㣠㷠㧠㳠ã§æå¹ãªå Žåã 㜠ã ã ㊠㧠ã¢ã®æ¬ é¥ã« ã ã ã ã· ã¹ ãã 㯠iSCSI ãŸã㯠FCoE ã¿ ãŒã² ã ã ã«å¯Ÿ ã ㊠BFS ã㌠ã ãå®è¡ã§ ã ãªãå Žåãã ã ãŸãã MBA ã ã© ã€ã㯠ã ã®èšå®ã®ã 㧠ã 㯠ãå®è¡ ã ã ã ã®ã ã ãªèšå® ãæ€åº ã ãã ãš ã ã ã ã³ ã ã ã衚瀺 ã ããŸãã ãœãªã¥ãŒã·ã§ã³ ïŒ 7.6.
19â ã ã© ãã«ã· 㥠ãŒã 㣠ã³ã° ãã®ä» ãã©ãã« ïŒ ã· ã¹ ãã ã« ã 㣠ãŠã¯ã ã· ã¹ ãã ã®èµ·ååŸã«å ã ä»ãã QLogic BCM57xx ã ãã³ BCM57xxx ã¢ã ã ã¿ ãŒãã æé©ãª 㬠ãã«ã§å®è¡ ã ããªãå Žåãã ãã ãœãªã¥ãŒã·ã§ã³ ïŒ ã· ã¹ ãã ã« ã 㣠ãŠã¯ã ã· ã¹ ãã ã®èµ·ååŸã«ã¢ã ã ã¿ ãå ã ä»ã ã ãš ã ã· ã¹ ãã ã® BIOS ãã 㣠ã 㷠㥠㩠〠㳠ãµã€ ãºã ãã³åŸ
ã¡æé 㿠〠ããŒã ã» ã ã ã ãªã å Žåãã ã ãŸãã ã¢ã ã ã¿ ãå ã ä»ããã ãš ã«ã ã· ã¹ ãã ãåèµ·å ã ㊠ã ã ã ãã ãã©ãã« ïŒ SNP ã 㢠㳠〠㳠㹠ã ãŒã«ãã ãš ã QCC ã® Resource Reservations ïŒ ãª ãœ ãŒã¹äºçŽïŒ ã§èšå®ã㧠ã 㪠ã 㪠ãã ãœãªã¥ãŒã·ã§ã³ ïŒ SNP ãå〠㳠㹠ã ãŒã« ã ãŸãã ã· ã¹ ãã ã ã SNP ã 㢠㳠〠㳠㹠ã ㌠ã«ããåã«ã Configurations ïŒèšå®ïŒ ããŒãžã® Resource Reserv
æ¬ç€Ÿ Cavium, Inc. 2315 N. First Street San Jose, CA 95131 408-943-7100 æµ·å€æ¯ç€Ÿ 〠㮠㪠㹠| 㢠ã€ã« ã© ã³ ã | ã 〠ã | ã ã© ã³ ã¹ | 〠㳠ã | æ¥æ¬ | äžåœ | éŠæž¯ | ã· ã³ ã¬ããŒã« | å°æ¹Ÿ | 〠㹠㩠ãšã« Copyright © 2015â2018 Cavium, Inc. ãã¹ãŠã®èäœæš©ã¯å
šäžçã§ä¿è· ã ããŠã ãŸãã QLogic Corporation ã¯ã Cavium, Inc. ã®å®å
šææåäŒç€Ÿã§ãã QLogicã FastLinQã ã ã ã³ QConvergeConsole ã¯ã Cavium, Inc.