Dell EMC PowerEdge R450 Technical Specifications Part Number: E74S Regulatory Type: E74S001 July 2021 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Technical specifications............................................................................................... 4 Chassis dimensions............................................................................................................................................................. 5 System weight......................................................................................................................................................................
1 Technical specifications The technical and environmental specifications of your system are outlined in this section.
Chassis dimensions Figure 1. PowerEdge R450 Chassis dimensions Table 1. Chassis dimensions Drives Xa 4 x 3.5-inch 482 434 mm mm (17.08 (18.976 inches) inches) 42.8 677.8 mm (26.685 inches) 22 mm (0.866 inches) mm(1.68 without bezel (Ear to PSU surface) 5 35.84 mm (1.41 inches) with inches) 691.07mm (27.207 inches) bezel (Ear to butterfly L bracket housing) 712.95 mm (28.069 inches) 482 434 mm mm (17.08 (18.976 inches) inches) 42.8 627.03 mm (24.686 inches) 22 mm (0.866 inches) mm(1.
System weight Table 2. PowerEdge R450 system weight System configuration Maximum weight (with all drives/SSDs/bezel) 4 x 3.5-inch system 18.62 kg (41.05 pound) 8 x 2.5-inch system 16.58 kg (36.55 pound) Processor specifications Table 3.
● ● ● ● Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Server VMware ESXi For more information, go to www.dell.com/ossupport. Cooling fans specifications The PowerEdge R450 system supports Standard (STD) fans, and High performance SLVR fans . NOTE: For more information about the fan support configuration or matrix, see Thermal restriction matrix. Table 5.
Table 5. PowerEdge R450 cooling fan specifications (continued) Fan type Abbreviation Also known as Label color Label image Figure 3. High performance (Silver grade) fan System battery specifications The PowerEdge R450 system supports CR 2032 3.0-V lithium coin cell system battery. Expansion card riser specifications The PowerEdge R450 system supports up to two PCI express (PCIe) Gen 4 expansion cards. Table 6.
Table 7. Memory specifications Single processor DIMM type RDIMM DIMM rank DIMM capacity Single rank 8 GB Dual rank Dual processors Maximum DIMM capacity Minimum DIMM capacity Maximum DIMM capacity 8 GB 64 GB 16 GB 128 GB 16 GB 16 GB 128 GB 32 GB 256 GB 32 GB 32 GB 256 GB 64 GB 512 GB 64 GB 64 GB 512 GB 128 GB 1 TB Minimum DIMM capacity Table 8.
NOTE: The micro USB 2.0 compliant port can only be used as an iDRAC Direct or a management port. NIC port specifications The PowerEdge R450 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports embedded on the LAN on Motherboard (LOM) and integrated on the optional Open Compute Project (OCP) cards. Table 11. NIC port specification for the system Feature Specifications LOM card 1 GbE x 2 OCP card (OCP 3.
Table 13. Supported video resolution options for the system (continued) Resolution Refresh rate (Hz) Color depth (bits) 1440 x 900 60 8, 16, 32 1600 x 900 60 8, 16, 32 1600 x 1200 60 8, 16, 32 1680 x 1050 60 8, 16, 32 1920 x 1080 60 8, 16, 32 1920 x 1200 60 8, 16, 32 Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Documentation > Regulatory Information on www.dell.
Table 17. Maximum shock pulse specifications (continued) Maximum shock pulse Specifications Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms Particulate and gaseous contamination specifications The following table defines the limitations that prevent the damage to the IT equipment and/or, or both failure from particulate and gaseous contamination.
Table 20. Thermal restriction matrix for processor and fans (continued) Configuration / Processor TDP 4 x 3.5-inch configuration 8 x 2.5-inch SAS/SATA configuration Maximum Ambient Temperature 120 W STD fan STD fan 40°C STD HSK STD HSK STD fan STD fan STD HSK STD HSK STD fan STD fan STD HSK STD HSK STD fan STD fan STD HSK STD HSK HPR (SLVR) fan HPR (SLVR) fan HPR HSK HPR HSK HPR (SLVR) fan HPR (SLVR) fan HPR HSK HPR HSK 135 W 150 W 165 W 165 W 8 cores, 3.
Table 22. Thermal restriction matrix for ASHRAE A2, A3 and A4 Dell EMC PowerEdge Server Standard Operating Support (ASHRAE A2 compliant) NOTE: All options supported unless otherwise noted. Dell EMC PowerEdge Server Extended Inletient 40 ° C Operating Support (ASHRAE A3 compliant) Mellanox CX5 DP 25 ● Two PSUs are required. System GbE SFP28 in both performance may be reduced in the event configurations. of a PSU failure. Solarflare Medford2 DP 25 GbE SFP28 in both configurations.