Dell EMC PowerEdge R240 Technical Specifications Guide Regulatory Model: E57S Series Regulatory Type: E57S001 Dec 2020 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
1 Technical specifications The technical and environmental specifications of your system are outlined in this section.
Table 1. Dell EMC PowerEdge R240 chassis dimensions Xa Xb Y Za Zb Zc 482.0 mm 434.0 mm 42.8 mm 534.496 mm 573.596 mm (18.97 inches) (17.08 inches) (1.68 inches) With bezel: 35.64 mm (1.4 inches) (21.04 inches) (22.58 inches) Without bezel: 22.0 mm (0.87 inches) System weight Table 2. Dell EMC PowerEdge R240 system weight System configuration Maximum weight (with all drives/SSDs) 4 x 3.5-inch drives 12.2 kg (26.89 lb) Processor specifications Table 3.
Cooling fans specifications The Dell EMC PowerEdge R240 system supports the following cooling fans. NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA. Table 5. Dell EMC PowerEdge R240 fan support matrix Front storage Fan 1 Fan 2 Fan 3 Fan 4 Max allowable 3.
Table 9. Dell EMC PowerEdge R240 system controller cards Internal controllers External controllers ● ● ● ● ● 12Gbps SAS Ext. HBA PERC H730P PERC H330 S140 HBA330 Drive specifications Drives The Dell EMC PowerEdge R240 system supports: ● 4 x 3.5-inch hot-swappable SAS, SATA, or SSD ● 4 x 3.5-inch cabled drives ● 2 x 3.5-inch cabled drives NOTE: LED functionality is not supported on cabled hard disk drive configuration. Backplane: ● Up to 4 x 3.5-inch SAS, SATA drives, or SSD drives ● Up to 4 x 2.
NIC ports specifications The Dell EMC PowerEdge R240 system supports up to two 10/100/1000 Mbps Network Interface Controller (NIC) ports that are located on the back panel. Serial connector specifications The Dell EMC PowerEdge R240 system supports one serial connector on the back panel, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant. VGA ports specifications The Dell EMC PowerEdge R240 system supports DB-15 VGA connector.
Environmental specifications NOTE: For additional information about environmental certifications, refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/support/home. Table 14.
Standard operating temperature Table 20. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 ft) 10–35°C (50–95°F) with no direct sunlight on the equipment. Expanded operating temperature Table 21. Expanded operating temperature specifications Expanded operating temperature Specifications Continuous operation 5°C–40°C at 5% to 85% RH with 29°C dew point.
Table 22. Particulate contamination specifications Particulate contamination Specifications Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. NOTE: Air entering the data center must have MERV11 or MERV13 filtration.