SNMP Reference Guide for iDRAC , Chassis Management Controller and OpenManage Enterprise - Modular Management Software 1.20.00 August 2020 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Introduction................................................................................................................. 5 What is new in this release................................................................................................................................................5 Supported SNMP Versions...............................................................................................................................................
PowerEdge VRTX CMC 3.3 , PowerEdge FX2 CMC 2.3 and OM Enterprise Modular Traps 1.20.00......... 65 System Trap Group.....................................................................................................................................................66 Storage Trap Group.................................................................................................................................................... 70 Audit Traps...............................................................
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
MM Version SNMP Alerts / Traps SNMP Gets Management Module SNMP v1, v2 SNMP v1, v2 NOTE: SNMP alerts and traps v3 is supported on iDRAC7 for firmware version 2.10.10.10 and later systems. Managed Object Used in This Document The MIB is divided into several major groups. The following table provides information about the MIB names, name of the agent that uses each MIB and the purpose: Table 2. Managed Object Used in This Document MIB Name Agent / Hardware Supported Purpose of the MIB 10892.
NOTE: You can download the Mibs that are listed from downloads and drivers page at Dell.com/OpenManageManuals. . Server Administrator Remote Access MIB NOTE: This section contains information that is applicable only if the Server Administrator is installed in the system. The Server Administrator Remote Access MIB ( filename dcs3rmt.mib ) provides in-band information about remote access hardware that may be present in your system.
Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at dell.com/support/manuals.
Table 6. UUID Table Entry (continued) Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 7. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 8. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
● The Server Administrator Messages Reference Guide lists the messages that you can receive on your systems management console or on your operating system’s event viewer. This guide explains the text, severity, and cause of each message that the server administrator issues. ● The Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object format (MOF) file.
Table 15. System Battery Status (continued) Access Read-only Table 16. System Battery Reading Name systemBatteryReading Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.6 Description This attribute defines the reading of the battery. Syntax SystemBatteryReadingFlags Access Read-only Table 17. System Battery Location Name Name systemBatteryLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.7 Description This attribute defines the location of the battery.
Table 21. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.4 Description. This attribute defines the state settings of the amperage probe. Syntax StateSettingsFlags Access Read-only Table 22. Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.5 Description This attribute defines the probe status of the amperage probe. Syntax StatusProbeEnum Access Read-only Table 23.
Table 26. Amperage Probe Upper Non Recoverable Threshold (continued) Syntax Signed32BitRange Access Read-only Table 27. Amperage Probe Upper Critical Threshold Name amperageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.10 Description This attribute defines the upper critical threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Syntax Signed32BitRange Access Read-only Table 28.
Table 32. Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.15 Description This attribute defines the probe capabilities of the amperage probe. Syntax ProbeCapabilitiesFlags Access Read-only Table 33. Amperage Probe Discrete Reading Name amperageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.16 Description This attribute defines the reading for an amperage probe of type amperageProbeTypeIsDiscrete.
Table 37. Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.4 Description. This attribute defines the state settings of the power unit. Syntax StateSettingsFlags Access Read-only Table 38. Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.5 Description This attribute defines the redundancy status of the power unit. Syntax StatusRedundancyEnum Access Read-only Table 39.
Table 42. Power Supply Chassis Index (continued) Description This attribute defines the index (one based) of the system chassis. Syntax PowerSupplyTableEntry Access Read-only Table 43. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 Description This attribute defines the index (one based) of the power supply. Syntax ObjectRange Access Read-only Table 44. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.
Table 48. Power Supply Type (continued) Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.7 Description This attribute defines the type of the power supply. Syntax String64 Access Read-only Table 49. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 Description This attribute defines the location of the power supply. Syntax String64 Access Read-only Table 50.
Table 53. Power Supply Configuration Error Type (continued) Access Read-only Table 54. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.13 Description This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Syntax BooleanType Access Read-only Table 55. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .
Table 59. Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 Description This attribute defines the index (one based) of the power usage information. Syntax ObjectRange Access Read-only Table 60. Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.3 Description This attribute defines the state capabilities of the power usage information. Syntax StateCapabilitiesFlags Access Read-only Table 61.
Table 64. Power Usage Cumulative Wattage (continued) Access Read-only Table 65. Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.8 Description This attribute defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. Syntax DateName Access Read-only Table 66. Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.
Table 70. Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.13 Description This attribute defines the date and time at which the data collection started for the value reported by the powerUsagePeakAmps attribute. Syntax DateName Access Read-only Table 71. Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.
Table 75. Power Usage Power Cap Setting (continued) Access Read-only Table 76. Power Usage Power Cap Value Name powerUsagePowerCapValue Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.19 Description This attribute defines the system power cap value (in Watts). Syntax Unsigned32BitRange Access Read-only Table 77. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.
Table 81. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 Description This attribute defines the state capabilities of the voltage probe. Syntax StateCapabilitiesFlags Access Read-only Table 82. Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.4 Description. This attribute defines the state settings of the voltage probe.
Table 86. Voltage Probe Location Name (continued) Access Read-only Table 87. Voltage Probe Upper Non Recoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 Description This attribute defines the upper non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 88.
Table 92. Voltage Probe Lower NonRecoverable Threshold (continued) Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 Description This attribute defines the lower non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 93. Voltage Probe Probe Capabilities Name voltageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.
Table 97. System Express Service Code (continued) Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 98. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system. Syntax StringType Access Read-only Table 99. System Blade Slot Number Name systemBladeSlotNumber Object ID 1.3.6.1.4.1.674.10892.5.1.3.
Table 103. System Aisle Name (continued) Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 104. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.0 Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only Table 105. System Rack Slot Name systemRackSlot Object ID 1.3.6.1.4.1.674.10892.5.1.3.11.
Table 109. System Room Name (continued) Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 110. System Chassis System Height Name systemChassisSystemHeight Object ID 1.3.6.1.4.1.674.10892.5.1.3.16.0 Description This attribute defines the height of the system, in 'U's. A U is a standard unit of measure for the height of a rack or rack-mountable component.
2 Chassis Management Controller Group Table 115. Chassis Management Controller Group Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting.
Table 119. DRsProductManufacturer Name drsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only Table 120. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 121.
Table 125. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 126. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 127. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Table 131. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 132. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis. Syntax DellString Access Read-only Table 133. DRsProductChassisRackSlot Name drsProductChassisRackSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Table 137. DRsProductChassisSize Name drsProductChassisSize Object ID 1.3.6.1.4.1.674.10892.2.1.1.22 Description Defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component. Syntax INTEGER Access Read-only Table 138. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller 1.
Table 142. DRsGlobalCurrStatus (continued) Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 143. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 144. DRsKVMCurrStatus Name drsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.
Table 148. DRsBladeCurrStatus Name drsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 149. DRsTempCurrStatus Name drsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 150.
Table 153. DRsCMCProcessorTemperature (continued) Syntax DellTemperatureReading Access Read-only Table 154. DRsGlobalPrevStatus Name drsGlobalPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.1 Description Defines the previous chassis status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 155. DRsIOMPrevStatus Name drsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Table 159. DRsFanPrevStatus (continued) Description Defines the previous fan health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 160. DRsBladePrevStatus Name drsBladePrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.7 Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 161. DRsTempPrevStatus Name drsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.
Table 165. DRsKVMChangeTime Name drsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only Table 166. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 167. DRsPowerChangeTime Name drsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.
Table 171. DRsCMCChangeTime Name drsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only Chassis Power The following MIB tables provide power information for the chassis being monitored by the chassis management controller. Table 172. DRsCMC Power Table Name drsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table.
Table 176. DRsChassisIndex Name drsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 177. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2 Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on.
Table 182. DRsKWhCumulativeTime Name drsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only Table 183. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 184.
Table 188. DRsWattsReading Name drsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in watts). Syntax DellPowerReading Access Read-only Table 189. DRsAmpsReading Name drsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in watts).
Table 193. DRsPSUMonitoringCapable (continued) Syntax DellCMCPSUCapable Access Read-only Table 194. DRsPSUVoltsReading Name drsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5 Description Defines the instantaneous PSU voltage reading. Syntax DellPowerReading Access Read-only Table 195. DRsPSUAmpsReading Name drsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU current reading.
CMC Server Information The following MIB tables provide CMC server information being monitored by the chassis management controller. Table 199. DRsServerIndex Name drsServerIndex Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.1 Description Defines the index (one-based) of the associated CMC server. Syntax DellCMCServerIndexRange Access Read-only Table 200. DRsServerMonitoringCapable Name drsServerMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.
Table 204. DRsServerNodeID (continued) Syntax DellString Access Read-only Table 205. DRsServerModel Name drsServerModel Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.7 Description This attribute defines the Model of the CMC server. Syntax DellString Access Read-only Table 206. DRsServerAssetTag Name drsServerAssetTag Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.8 Description This attribute defines the Asset Tag of the CMC server. Syntax DellString Access Read-only Table 207.
Table 210. DRsServerAssignedServerSlots (continued) Description This attribute defines the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or more server slots, the value will be a comma-separated list of one or more server slot names. If the storage sled is not assigned to a server slot, the value will be an empty string. If this is not a storage sled, the value will be N/A.
Table 215. DrsCAMessage (continued) Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 216. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 Description Defines the message ID of the alert. Syntax DisplayString Access Read-only Table 217. DrsCA2Message Name drsCA2Message Object ID 1.3.6.1.4.1.674.10892.2.21.10.2 Description Defines the message describing the alert.
Table 220. DrsCA2FQDD (continued) Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 221. DRsAlertSystem Name drsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String Access Read-only Table 222. DRsAlertTableIndexOID Name drsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier.
Table 226. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
3 OpenManage Enterprise-Modular Management Software Group The Dell Remote Access Controller Out-of-Band MIB for Enterprise-Modular Management Software. This MIB consists of information for the following groups: NOTE: From release Enterprise - Modular Management 1.20.00 or later, the MX7000-OME-M and later MIB file is published in both types of SMI (Structure of Managed Information) notations: v1 and v2. The v1 copy of the Enterprise - Modular Management 1.20.00 and later MIB file is named MX7000-OME-M-v1.
Table 229. DmmProductDescription (continued) Syntax DellString Access Read-only Table 230. DmmProductManufacturer Name dmmProductManufacturer Object ID 1.3.6.1.4.1.674.10892.6.1.1.4 Description This attribute defines the product manufacturer of a chassis management module. Syntax DellString Access Read-only Table 231. DmmProductVersion Name dmmProductVersion Object ID 1.3.6.1.4.1.674.10892.6.1.1.5 Description This attribute defines the product version of a chassis management module.
Table 235. DmmProductChassisName (continued) Syntax DellString Access Read-only Table 236. DmmProductType Name dmmProductType Object ID 1.3.6.1.4.1.674.10892.6.1.1.10 Description This attribute defines type of a remote management module. Syntax DellString Access Read-only Table 237. DmmProductChassisDataCenter Name dmmProductChassisDataCenter Object ID 1.3.6.1.4.1.674.10892.6.1.1.11 Description This attribute defines the Data Center locator of the chassis.
Table 241. DmmProductChassisModel (continued) Syntax DellString Access Read-only Table 242. DmmProductChassisExpressServiceCode Name dmmProductChassisExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.6.1.1.16 Description This attribute defines the Express Service Code of the chassis. Syntax DellString Access Read-only Table 243. DmmProductChassisSystemID Name dmmProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.6.1.1.
Table 246. DmmGlobalSystemStatus (continued) Description This attribute defines the overall chassis status being monitored by the chassis management module. Syntax DellStatus Access Read-only Table 247. DmmIOMCurrStatus Name dmmIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.6.3.1.1 Description This attribute defines the IOM subsystem status being monitored by the chassis management module. Syntax DellStatus Access Read-only Table 248. DmmRedCurrStatus Name dmmRedCurrStatus Object ID 1.3.6.
Table 252. DmmTempCurrStatus Name dmmTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.6.3.1.6 Description This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management module. Syntax DellStatus Access Read-only Table 253. DmmMMCurrStatus Name dmmMMCurrStatus Object ID 1.3.6.1.4.1.674.10892.6.3.1.7 Description This attribute defines the health status being monitored by the chassis management module. Syntax DellStatus Access Read-only Table 254.
Table 257. DmmPSUTable (continued) Object ID 1.3.6.1.4.1.674.10892.6.1.4.2 Description This object defines the PSU table. Syntax SEQUENCE OF DmmPSUTableEntry Access Read-only Table 258. DmmPSUTableEntry Name dmmPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.6.1.4.2.1 Description This object defines the PSU table entry. Syntax DmmPSUTableEntry Access Read-only Power Information The following MIB attributes provide power information for the Enterprise - Modular Management Table 259.
Table 262. DmmPowerKWhCumulativeTime (continued) Description This attribute defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only Table 263. DmmPowerWattsPeakUsage Name dmmPowerWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.6.4.1.1.5 Description This attribute defines the chassis peak power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only Table 264.
PSU Information The following MIB attributes provide psu information for the Enterprise - Modular Management Table 268. DmmPSUChassisIndex Name dmmPSUChassisIndex Object ID 1.3.6.1.4.1.674.10892.6.4.2.1.1 Description This attribute defines the index (one-based) of the associated chassis . Syntax DellPowerIndexRange Access Read-only Table 269. DmmPSUIndex Name dmmPSUIndex Object ID 1.3.6.1.4.1.674.10892.6.4.2.1.2 Description This attribute defines the index (one-based) of the associated PSU .
Table 273. DmmPSUCapacity (continued) Syntax DellPowerReading Access Read-only Table 274. DmmPSUVoltage Name dmmPSUVoltage Object ID 1.3.6.1.4.1.674.10892.6.4.2.1.7 Description This attribute defines the input voltage of the PSU. Syntax DellPowerReading Access Read-only Table 275. DmmPSUCurrStatus Name dmmPSUCurrStatus Object ID 1.3.6.1.4.1.674.10892.6.4.2.1.8 Description This attribute defines the current status of the PSU.
Table 278. DmmCA2MessageArgs (continued) Syntax DellString Access Read-only Table 279. DmmCA2AlertStatus Name dmmCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.6.5.1.4 Description Status of the alert. Syntax DellStatus Access Read-only Table 280. DmmCA2FQDD Name dmmCA2FQDD Object ID 1.3.6.1.4.1.674.10892.6.5.1.5 Description Fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Table 281. Generic Traps Object ID Name Description 1.3.6.
4 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 282. RAC Traps TrapID Name Description Severity Category Cause Supporte d by RAC Platform 0 CodeStart SNMP agent is initializing itself Information Status RAC power on or reset. All 1 Authentication Failure Request Critical received with an invalid community name Error SNMP request with an invalid community name. All 1001 alertDrscTest TrapEvent The RAC generated a test trap event in response to a user request Information Status A test SNMP trap generated by All a RAC.
Table 283.
Table 283.
Table 283.
drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in the Dell Remote Access Controller Out-ofBand Group section. System Trap Group The System Trap Group contains traps that fall under the System event category. Table 285. Amperage Probe Traps TrapID Description Category SubCategory Severity Current sensor reading is within range. Status Events Amperage Informational Current sensor has detected a warning value.
Table 289. Fan Traps TrapID Description Category SubCategory Severity Fan information. Status Events Fan Informational Fan warning. Status Events Fan Minor Fan failure. Error Events Fan Critical Category SubCategory Severity Status Events Hardware Configuration Informational Status Events Hardware Configuration Minor Error Events Hardware Configuration Critical Description Category SubCategory Severity IO Virtualization warning.
Table 293. Power Supply Traps (continued) TrapID Description Category SubCategory Severity 2186 Power supply has detected a warning. Status Events Power Supply Minor Power supply has detected a failure. Error Events Power Supply Critical Status Events Power Supply Informational Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Description Category SubCategory Severity Power usage information.
Table 298. System Event Log Traps TrapID Description Category SubCategory Severity System Event Log information. Status Events System Event Log Informational System Event Log warning.
Table 301. Voltage Probe Traps (continued) TrapID Description Category SubCategory Severity 2171 Voltage sensor reading is within range. Status Events Voltage Informational Voltage sensor has detected a warning value. Status Events Voltage Minor Voltage sensor has detected a failure value. Error Events Voltage Critical alert2VoltageProbeWarning 2170 alert2VoltageProbeFailure 2169 Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category.
Table 305. Storage Fan Traps TrapID Description Category Subcategory Severity Storage fan information. Error Events Fan Informational Storage fan warning. Status Events Fan Minor Storage fan failure. Error Events Fan Critical alert2StorageFanInformation 4203 alert2StorageFanWarning 4202 alert2StorageFanFailure 4201 Table 306. Storage Physical Disk Traps TrapID Description Category Subcategory Severity Error Events Physical Disk Informational Storage physical disk warning.
Table 309. Storage Management Status Traps (continued) TrapID Description Category Subcategory Severity Error Events Storage Management Minor Error Events Storage Management Critical Category Subcategory Severity Error Events Temperature Probe Informational Error Events Temperature Probe Minor Error Events Temperature Probe Critical Category Subcategory Severity Storage virtual disk information. Error Events Virtual Disk Informational Storage virtual disk warning.
Table 312. Audit CMC Traps (continued) TrapID Description Category SubCategory Severity 8690 Chassis Management Controller audit warning. Status Events CMC Minor Chassis Management Controller audit failure or critical event. Error Events CMC Critical Category SubCategory Severity Status Events IO Virtualization Minor Description Category SubCategory Severity License information. Status Events License Informational License warning. Status Events License Minor License failure.
Table 318. Audit Software Change Traps TrapID Description Category SubCategory Severity Error Events Software Change Critical alert2SoftwareChangeAuditFailure 8361 Software change audit failure or critical event. Configuration Traps The Configuration Trap group contains traps that fall under the Configuration event category. Table 319. Configuration IO Virtualization Traps TrapID Description Category SubCategory Severity IO virtualization configuration information.
5 iDRAC MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 and later versions (iDRAC7, iDRAC8 and iDRAC9). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 and later of a system. NOTE: From iDRAC7 firmware release r1.30.
iDRAC Out-of-Band Group The objects of the Integrated Dell Remote Access Controller (iDRAC) MIB ( iDRAC-SMIv1.mib and iDRAC-SMIv2.mib ) are organized into subgroups of the iDRAC Out-of-Band Group. The subgroups are: ● ● ● ● ● ● RAC Information Group Chassis Information Group System Information Group Status Group System Details Group Storage Details Group The following sections document the subgroups and the objects within each subgroup.
Table 329. RAC Version Name racVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.5.0 Description This attribute defines the product version of a remote access card. Syntax StringType Access Read-only Table 330. RAC URL Name racURL Object ID 1.3.6.1.4.1.674.10892.5.1.1.6.0 Description This attribute defines the out-of-band UI URL of a remote access card. Syntax StringType Access Read-only Table 331. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.
Table 334. Chassis Name Modular (continued) Object ID 1.3.6.1.4.1.674.10892.5.1.2.2.0 Description This attribute defines the chassis name of the modular chassis. The value is zero length if not a modular system. Syntax StringType Access Read-only Table 335. Chassis Model Modular Name chassisModelModular Object ID 1.3.6.1.4.1.674.10892.5.1.2.3.0 Description This attribute defines the model of the modular chassis. The value is zero length if not a modular system.
Table 339. Intrusion State Settings (continued) Syntax StateSettingsFlags Access Read-only Table 340. Intrusion Status Name intrusionStatus Object ID 1.3.6.1.4.1.674.10892.5.4.300.70.1.5 Description This attribute defines the status of the intrusion sensor. Syntax ObjectStatusEnum Access Read-only Table 341. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.5.4.300.70.1.6 Description This attribute defines the reading of the intrusion sensor.
Table 345. System Service Tag Name systemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.2.0 Description This attribute defines the service tag of the system. Syntax StringType Access Read-only Table 346. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 347. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.
Table 351. System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 352. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 353. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.
Table 357. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 358. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 359.
Table 362. System OEM OS Version (continued) Access Read-only Table 363. System Lockdown Mode Name systemLockdownMode Object ID 1.3.6.1.4.1.674.10892.5.1.3.20.0 Description This attribute defines the system Lockdown mode is enabled or disabled. Syntax SystemLockdownModeEnum Access Read-only Status Group The Status Group objects provide status information about the system and storage. Table 364. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.
Table 367. System Power State (continued) Access Read-only Table 368. System Power Up Time Name systemPowerUpTime Object ID 1.3.6.1.4.1.674.10892.5.2.5.0 Description This attribute defines the power-up time of the system in seconds. Syntax Unsigned32BitRange Access Read-only Systems Details Group The Systems Details Group contains objects and tables that provide detailed information about the system in which the iDRAC resides.
Table 372. Power Unit State Settings (continued) Description. This attribute defines the state settings of the power unit. Syntax StateSettingsFlags Access Read-only Table 373. Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.5 Description This attribute defines the redundancy status of the power unit. Syntax StatusRedundancyEnum Access Read-only Table 374.
Table 377. Power Supply Chassis Index (continued) Access Read-only Table 378. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.2 Description This attribute defines the index (one based) of the power supply. Syntax ObjectRange Access Read-only Table 379. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.3 Description This attribute defines the state capabilities of the power unit.
Table 383. Power Supply Type (continued) Syntax String64 Access Read-only Table 384. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.8 Description This attribute defines the location of the power supply. Syntax String64 Access Read-only Table 385. Power Supply Maximum Input Voltage Name powerSupplyMaximumInputVoltage Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.
Table 389. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.13 Description This attribute defines a boolean value that reports whether the power supply is capable of monitoring power consumption. Syntax BooleanType Access Read-only Table 390. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.
Table 394. Voltage Probe Index (continued) Description This attribute defines the index (one based) of the voltage probe. Syntax ObjectRange Access Read-only Table 395. Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.3 Description This attribute defines the state capabilities of the voltage probe. Syntax StateCapabilitiesFlags Access Read-only Table 396.
Table 400. Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.8 Description This attribute defines the location name of the voltage probe. Syntax String64 Access Read-only Table 401. Voltage Probe Upper Non Recoverable Threshold Name voltageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.9 Description This attribute defines the upper non-recoverable threshold of the voltage probe.
Table 405. Voltage Probe Lower Critical Threshold (continued) Syntax Signed32BitRange Access Read-only Table 406. Voltage Probe Lower NonRecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 Description This attribute defines the lower non-recoverable threshold of the voltage probe. The value is an integer representing the voltage of the threshold in millivolts. Syntax Signed32BitRange Access Read-only Table 407.
Table 410. Amperage Probe Index (continued) Syntax ObjectRange Access Read-only Table 411. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.3 Description This attribute defines the state capabilities of the amperage probe. Syntax StateCapabilitiesFlags Access Read-only Table 412. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.4 Description.
Table 416. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.8 Description This attribute defines the location of the amperage probe. Syntax String64 Access Read-only Table 417. Amperage Probe Upper Non Recoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.30.1.9 Description This attribute defines the upper non recoverable threshold of the amperage probe.
Table 421. Amperage Probe Lower Critical Threshold (continued) Syntax Signed32BitRange Access Read-only Table 422. Amperage Probe Lower NonRecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.14 Description This attribute defines the lower non recoverable threshold of the amperage probe. The value is an integer representing the amperage of the threshold in milliamps. Syntax Signed32BitRange Access Read-only Table 423.
Table 426. System Battery Index (continued) Syntax ObjectRange Access Read-only Table 427. System Battery State Capabilities Name systemBatteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.3 Description This attribute defines the state capabilities of the battery. Syntax StateCapabilitiesFlags Access Read-only Table 428. System Battery State Settings Name systemBatteryStateSettings Object ID 1.3.6.1.4.1.674.10892.5.4.600.50.1.4 Description.
Table 432. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.1 Description This attribute defines the index (one based) of the associated system chassis. Syntax ObjectRange Access Read-only Table 433. Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.2 Description This attribute defines the index (one based) of the power usage information. Syntax ObjectRange Access Read-only Table 434.
Table 438. Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.7 Description This attribute defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute. Syntax Unsigned32BitRange Access Read-only Table 439. Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.
Table 443. Power Usage Peak Amps (continued) Description This attribute defines the peak amperage reading (in tenths of Amps) for this entity since the date and time specified by the powerUsagePeakAmpsStartDateName attribute. Syntax Unsigned32BitRange Access Read-only Table 444. Power Usage Peak Amps Start Date Name Name powerUsagePeakAmpsStartDateName Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.
Table 449. Power Usage Power Cap Setting Name powerUsagePowerCapSetting Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.18 Description This attribute defines the system power cap setting. Syntax PowerCapSettingEnum Access Read-only Table 450. Power Usage Power Cap Value Name powerUsagePowerCapValue Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.19 Description This attribute defines the system power cap value (in Watts). Syntax Unsigned32BitRange Access Read-only Table 451.
Table 453. Battery Number Name batteryNumber Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.1 Description Instance number of this battery entry. Syntax INTEGER Access read-only Table 454. Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.4 Description Current state of battery. Possible values: 1. The current state could not be determined. 2. The battery is operating normally. 3. The battery has failed and needs to be replaced. 4.
Table 457. Battery FQDD Name batteryFQDD Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.20 Description The battery's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax DisplayString Access read-only Table 458. Battery Display Name Name batteryDisplayName Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.21 Description The battery's friendly FQDD as represented in Storage Management.
Table 462. Controller FW Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.8 Description The controller's current firmware version. Syntax DisplayString Access read-only Table 463. Controller Cache Size In MB Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.9 Description The controller's current amount of cache memory in megabytes. Syntax INTEGER Access read-only Table 464.
Table 466. Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 Description Currently installed driver version for this controller on the host. Syntax DisplayString Access read-only Table 467. Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.42 Description The PCI slot on the server where the controller is seated. This data is not reported for embedded or integrated controllers.
Table 471. Controller Check Consistency Rate (continued) Description The check consistency rate is the percentage of the controller's resources dedicated to performing a check consistency on a redundant virtual disk. Syntax INTEGER Access read-only Table 472. Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.52 Description Identifies the patrol read mode setting for the controller. Possible values: 1.
Table 476. Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.61 Description Indicates whether hot spare drives would be put in power save mode by the controller. Syntax BooleanType Access read-only Table 477. Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Table 480. Controller Copy Back Mode (continued) 5. Copyback mode is disabled Syntax INTEGER Access read-only Table 481. Controller Security Status Name controllerSecurityStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.72 Description The controller's current security/encryption status. Possible values: 1. The current status could not be determined. 2. Controller is not operating in an encryption mode. 3. Controller is operating in the Local Key Management (LKM) encryption mode.
Table 484. Controller Load Balance Setting (continued) 4. Load balancing is inactive. Syntax INTEGER Access read-only Table 485. Controller Max Cap Speed Name controllerMaxCapSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.76 Description The maximum speed of the controller.in Gigbits per second (Gbps). Possible values: 1. The speed could not be determined. 2. 1.5 Gbps 3. 3.0 Gbps 4. 6.0 Gbps 5. 12.0 Gbps Syntax INTEGER Access read-only Table 486.
Table 489. Controller T10 PI Capability (continued) Description Description Indicates whether the controller supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields).Possible values: 1. Not one of the following. 2. Capable of supporting T10 PI. 3. Not capable of supporting T10 PI. Syntax INTEGER Access read-only Table 490. Controller RAID10 Uneven Spans Supported Name controllerRAID10UnevenSpansSupported Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.
Table 493. Controller Boot Mode (continued) 2. User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3. Continue Boot On Error. User interaction only required for critical messages. 4. Headless Mode Continue On Error. User interaction is not required. Controller boot may halt on Error. 5. Headless Safe Mode. Controller shall boot to safe mode on critical errors. Syntax INTEGER Access read-only Table 494.
Table 496. Physical Disk Number (continued) Description Instance number of this physical disk entry. Syntax INTEGER Access read-only Table 497. Physical Disk Name Name physicalDiskName Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.2 Description The physical disk's name as represented in Storage Management. Syntax DisplayString Access read-only Table 498. Physical Disk Manufacturer Name physicalDiskManufacturer Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 500. Physical Disk Product ID (continued) Syntax DisplayString Access read-only Table 501. Physical Disk Serial No Name physicalDiskSerialNo Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 Description The physical disk's unique identification number from the manufacturer. Syntax DisplayString Access read-only Table 502. Physical Disk Revision Name physicalDiskRevision Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.8 Description The firmware version of the physical disk.
Table 506. Physical Disk Bus Type (continued) Description The bus type of the physical disk. Possible values: 1. The bus type could not be determined. 2. Small Computer System Interface (SCSI). 3. Serial Attached SCSI (SAS). 4. Serial Advanced Technology Attachment (SATA). 5. Fibre channel. 6. PCIe. Syntax INTEGER Access read-only Table 507. Physical Disk Spare State Name physicalDiskSpareState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.22 Description The status of the disk as a spare.
Table 509. Physical Disk Part Number (continued) Access read-only Table 510. Physical Disk SAS Address Name physicalDiskSASAddress Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 Description The SAS address of the physical disk. Syntax DisplayString Access read-only Table 511. Physical Disk Negotiated Speed Name physicalDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 513. Physical Disk Smart Alert Indication (continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 Description Indicates whether the physical disk has received a predictive failure alert. Syntax BooleanType Access read-only Table 514. Physical Disk Manufacture Day Name physicalDiskManufactureDay Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 Description The day of the week on which the physical disk was manufactured. Syntax DisplayString Access read-only Table 515.
Table 518. Physical Disk Remaining Rated Write Endurance (continued) if the value is not available or not applicable (in the case of HDD media type) the value will be 255. Syntax INTEGER Access read-only Table 519. Physical Disk Power State Name physicalDiskPowerState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 Description The power state of the physical disk. Possible Values: 1. Not one of the following. 2. The physical disk is in the spun up state. 3.
Table 522. Physical Disk Security Status (continued) Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 Description The security/encryption status of the physical disk. Possible Values: 1. The physical disk supports encryption. 2. The physical disk does not support encryption 3. The physical disk is encrypted. 4. The physical disk is locked by a key. 5. The physical disk is locked by a foreign key. Syntax INTEGER Access read-only Table 523.
Table 526. Physical Disk T10 PI Capability (continued) Description Indicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1. Not one of the following. 2. Capable of supporting T10 PI. 3. Not capable of supporting T10 PI. Syntax INTEGER Access read-only Table 527. Physical Disk Block Size In Bytes Name physicalDiskBlockSizeInBytes Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 531. Physical Disk Current Active Controller Name physicalDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.62 Description Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. Syntax FQDDString Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 532. Physical Disk Failover Controller Name physicalDiskFailoverController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 535. Virtual Disk State (continued) Description The current state of this virtual disk (which includes any member physical disks.)Possible states: 1. The current state could not be determined. 2. The virtual disk is operating normally or optimally. 3. The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4. The virtual disk encountered a failure with one or all of the constituent redundant physical disks.
Table 539. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.13 Description The virtual disk's RAID type. Possible values: 1. Not one of the following 2. RAID-0 3. RAID-1 4. RAID-5 5. RAID-6 6. RAID-10 7. RAID-50 8. RAID-60 9. Concatenated RAID 1 10. Concatenated RAID 5 Syntax INTEGER Access read-only Table 540. Virtual Disk Stripe Size Name virtualDiskStripeSize Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 540. Virtual Disk Stripe Size (continued) Syntax INTEGER Access read-only Table 541. Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.20 Description The status of the virtual disk itself without the propagation of any contained component status.Possible values: 1. Other 2. Unknown 3. OK 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 542.
Table 545. Virtual Disk Cache Policy (continued) Description The cache policy of the physical disks that are part of this virtual disk. Possible values: 1. Enabled 2. Disabled 3. Default Syntax INTEGER Access read-only Table 546. Virtual Disk Operational State Name virtualDiskOperationalState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 Description The state of the virtual disk when there are progressive operations ongoing. Possible values: 1. There is no active operation running. 2.
Table 549. Virtual Disk Media Type (continued) Description List of media types of the physical disks part of this virtual disk. For e.g. HDD for Hard Disk Drive or SSD for Solid State Device. Syntax DisplayString Access read-only Table 550. Virtual Disk Remaining Redundancy Name virtualDiskRemainingRedundancy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.34 Description The number of physical disks which can be lost before the virtual disk loses its redundancy.
Table 554. Virtual Disk Block Size In Bytes (continued) Description The block size (in bytes) of the physical disk part of the virtual disk. Possible values: 1. 512 2. 4096. Syntax INTEGER Access read-only Table 555. Virtual Disk Adapter 1 Access Policy Name virtualDiskAdapter1AccessPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.39 Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access.
Table 558. Virtual Disk Adapter 4 Access Policy Name virtualDiskAdapter4AccessPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.42 Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access. Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 559. Virtual Disk Current Active Controller Name virtualDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892. 5.5 .1.20.130.3.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892. 2.6 .1.20.130.3.1.1. Table 562. Enclosure Number Name enclosureNumber Object Id 1.3.6.1.4.1.674.
Table 566. Enclosure Asset Tag Name enclosureAssetTag Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.9 Description The asset tag information for the enclosure. Syntax DisplayString Access read-only Table 567. Enclosure Connected Port Name enclosureConnectedPort Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.19 Description The port on the controller to which the storage enclosure is connected. Syntax DisplayString Access read-only Table 568.
Table 571. Enclosure Drive Count Name enclosureDriveCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.31 Description The number of disks present in the enclosure/backplane. Syntax INTEGER Access read-only Table 572. Enclosure Total Slots Name enclosureTotalSlots Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.32 Description The total physical drive slots in a storage enclosure or server backplane. Syntax INTEGER Access read-only Table 573.
Table 577. Enclosure Redundant Path Name enclosureRedundantPath Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.44 Description Indicates whether the controller has multiply paths to reach the storage enclosure. Syntax DisplayString Access read-only Table 578. Enclosure Position Name enclosurePosition Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.45 Description The position of the storage enclosure within a daisy chain. Syntax DisplayString Access read-only Table 579.
Table 582. Enclosure Type (continued) 2. Not applicable (i.e. object is not a backplane). 3. Supports SAS/SATA. 4. Supports PCIe 5. Both SAS/SATA and PCIe Syntax INTEGER Access read-only Enclosure Management Module Table The objects provide information about the Enclosure Management Module group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.
Table 585. Enclosure Management Module State (continued) Access read-only Table 586. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.6 Description The part number of the enclosure management module. Syntax DisplayString Access read-only Table 587. Enclosure Management Module FW Version Name enclosureManagementModuleFWVersion Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.
Table 590. Enclosure Management Module Display Name (continued) Description The enclosure management module's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Enclosure Fan Table The objects provide information about the Enclosure Fan Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.
Table 594. Enclosure Fan Speed (continued) Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.11 Description Indicates the current relative speed of the fan in RPMs. Syntax INTEGER Access read-only Table 595. Enclosure Fan Component Status Name enclosureFanComponentStatus Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.15 Description The status of the fan itself without the propagation of any contained component status. Possible values: 1. Other 2. Unknown 3. OK 4. Non-critical 5. Critical 6.
Table 598. Enclosure Power Supply Number Name enclosurePowerSupplyNumber Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.1 Description Instance number of this power supply unit. Syntax INTEGER Access read-only Table 599. Enclosure Power Supply Name Name enclosurePowerSupplyName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.2 Description The power supply unit's name as represented in Storage Management. Syntax DisplayString Access read-only Table 600.
Table 602. Enclosure Power Supply Component Status (continued) 3. OK 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 603. Enclosure Power Supply FQDD Name enclosurePowerSupplyFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.15 Description The power supply unit's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 604.
Table 606. Enclosure Temperature Probe Name (continued) Syntax DisplayString Access read-only Table 607. Enclosure Temperature Probe State Name enclosureTemperatureProbeState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4 Description The current state of this temperature probe. Possible states: 1. The current state could not be determined 2. The temperature probe is operating normally 3. The temperature probe has encountered a hardware problem or is not responding 4.
Table 611. Enclosure Temperature Probe Max Critical Value (continued) Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.10 Description The maximum temperature that will force the probe into a warning state. Syntax INTEGER Access read-only Table 612. Enclosure Temperature Probe Cur Value Name enclosureTemperatureProbeCurValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.11 Description The maximum temperature that will force the probe into a warning state.
iDRAC Traps The iDRAC generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC. The iDRAC generates events in response to changes in the status of sensors and other monitored parameters. When an event with predefined characteristics occurs on your system, the SNMP subagent sends information about the event, along with trap variables, to the management console.
Table 618. Alert Current Status (continued) Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 619. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString Table 619. Alert System Service Tag Access Read-only Table 620. Alert System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.5.3.1.5.
Table 623. Alert Message Arguments (continued) quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 623. Alert Message Arguments Access Read-only Table 624. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For modular systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length).
Table 627. Amperage Probe Traps (continued) TrapID Description Category SubCategory Severity 2178 Current sensor has detected a warning value. System Health Amperage Minor Current sensor has detected a failure value. System Health Amperage Critical Description Category SubCategory Severity Automatic system recovery (ASR) was performed.
Table 632. Processor Device Status Traps (continued) TrapID Description Category SubCategory Severity 2242 Processor device status has detected a warning. System Health Processor Minor Processor device status has detected a failure. System Health Processor Critical Description Category SubCategory Severity Processor device is absent. System Health Proc Absent Critical Description Category SubCategory Severity Fan information. System Health Fan Event Informational Fan warning.
Table 637. IO Virtualization Traps TrapID Description Category SubCategory Severity IO Virtualization failure or critical event. System Health IO Virtualization Critical Description Category SubCategory Severity Link status information. System Health Link Status Informational Link status warning. System Health Link Status Minor Link status failure or critical event. System Health Link Status Critical Description Category SubCategory Severity Memory device informational event.
Table 642. PCI Device Traps TrapID Description Category SubCategory Severity An informational event was detected for a PCI device. System Health PCI Device Informational A warning event was detected for a PCI device. System Health PCI Device Minor An error was detected for a PCI device. System Health PCI Device Critical Description Category SubCategory Severity Physical disk information. System Health Physical Disk Informational Physical disk warning.
Table 647. Power Usage Traps TrapID Description Category SubCategory Severity System performance restored. System Health Power Usage Informational System performance degraded. System Health Power Usage Minor The system halted because system System Health power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. Power Usage Critical Power Usage Information 2275 Power Usage Warning 2274 Power Usage Failure 2273 Table 648.
Table 651. Integrated Dual SD Module Redundancy Traps (continued) TrapID Description Category SubCategory Severity 2490 Integrated Dual SD Module redundancy is degraded. System Health IDSDM Redundancy Minor System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security warning. System Health Security Event Minor Security failure or critical event.
Table 655. Temperature Probe Traps (continued) TrapID Description Category SubCategory Severity 2162 Temperature sensor has detected a warning value. System Health Temperature Minor Temperature sensor has detected a failure value. System Health Temperature Critical Category SubCategory Severity System Health Temperature Statistics Minor System Health Temperature Statistics Critical Category SubCategory Severity vFlash Media device information.
Table 660. Voltage Probe Traps (continued) TrapID Description Category SubCategory Severity 2170 Voltage sensor has detected a warning value. System Health Voltage Minor Voltage sensor has detected a failure value. System Health Voltage Critical Category SubCategory Severity A small leak earlier detected on the System Health device is now resolved. Liquid Cooling Informational A small leak is detected on the device.
Table 665. Battery Traps (continued) TrapID Description Category SubCategory Severity Battery warning. Storage Battery Event Minor Battery failure. Storage Battery Event Critical Category SubCategory Severity Controller information. Storage Storage Contr Informational Controller warning. Storage Storage Contr Minor Controller failure. Storage Storage Contr Critical Category SubCategory Severity Enclosure information. Storage Storage Enclosr Informational Enclosure warning.
Table 670. Power Supply Traps TrapID Description Category SubCategory Severity Storage Power Supply Informational Storage Power Supply Minor Storage Power Supply Critical Description Category SubCategory Severity Storage Security information. Storage Security Event Informational Storage Security warning. Storage Security Event Minor Storage Security failure or critical event.
Table 674. Virtual Disk Trap TrapID Description Category SubCategory Severity Storage Virtual Disk Informational Virtual disk warning. Storage Virtual Disk Minor Virtual disk failure. Storage Virtual Disk Critical Category SubCategory Severity Storage Software defined Minor Storage Software defined Critical Storage VirtualDisk Information 4355 Virtual disk information. Storage Virtual Disk Warning 4354 Storage Virtual Disk Failure 4353 Table 675.
Table 678. CMC Traps (continued) TrapID Description Category SubCategory Severity 8690 Chassis Management Controller audit warning. Audit CMC Minor Chassis Management Controller audit failure or critical event. Audit CMC Critical Description Category SubCategory Severity Debug authorized. Audit Debug Informational Debug authorization failed. Audit Debug Minor Description Category SubCategory Severity User tracking warning.
Table 684. Power SupplyTraps (continued) TrapID Description Category SubCategory Severity 8329 Power supply audit failure or critical event. Audit Power Supply Critical Category SubCategory Severity Power usage audit information. Audit Power Usage Informational Power usage audit warning. Audit Power Usage Minor Power usage audit failure or critical Audit event.
Table 690. Auto Discovery Traps TrapID Description Category SubCategory Severity Auto discovery information.
Table 697. Test Trap (continued) TrapID Description Category SubCategory Severity 10395 The iDRAC generated a test trap event in response to a user request. Configuration Test Alert Informational iDRAC Memory Unresponsive Trap The iDRAC memory unresponsive trap contains traps that fall under the iDRAC Memory Unresponsive event category of iDRAC. The notifications which an SNMP v2 entity is required to implement. Table 698.