Dell EMC OpenManage Enterprise Modular Edition Version 1.10.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction................................................................................................................................. 5 New in this release................................................................................................................................................................ 5 Supported RACADM Interfaces..........................................................................................................................................
cfgDNSDomainName (Read or Write)........................................................................................................................27 cfgDNSDomainNameFromDHCP (Read or Write)....................................................................................................27 cfgStorageModule...............................................................................................................................................................28 cfgStorageModuleStorageMode.........
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for Dell EMC OpenManage Enterprise Modular (OME – Modular). Topics: • • • • New in this release Supported RACADM Interfaces RACADM Command Options Other documents you may need New in this release • Added the attribute, switch- to the command,connect to facilitate connection to I/O module serial consoles.
Option Description -o objectname Specifies the object name, if applicable. -m objectname Specifies the module. Table 2. Supported RACADM interfaces Type Local RACADM Address SSH RACADM Remote RACADM OME-Modular No Yes Yes NOTE: Multiple instances of remote RACADM can be run on a management station. Displayable Characters Displayable characters include the following set: • • • abcdefghijklmnopqrstuvwxwz ABCDEFGHIJKLMNOPQRSTUVWXYZ 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.
2 RACADM sub command details This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries.
• ASCII code 32 (space) NOTE: The - (dash) character cannot be the first character of the string, regardless of whether the string is quoted. There are different escaping rules for double quotation marks. There are different escaping rules for using single quotation mark and double quotation marks.
? ? arp chassisaction config ...
Address HWtype HWaddress Flags Mask Iface 192.168.0.121 ether 90:b1:1c:f4:34:f4 C pub chassisaction Description Executes the turn on, turn off, power cycle, or reset operation. Synopsis Input racadm chassisaction [-m ] • -m—Must be one of the following values: • • chassis—Default state if -m is not specified. • switch-—Where n=1-6 —Must be one of the following values: • • • • • powerdown—Graceful shutdown of the module. powerup—Turns on the module.
Examples • Executes on a leader, adds a stand-alone chassis to the group: racadm chassisgroup add -m 192.168.0.
• • • • • CDEV—Devices • CAPP—Application • CTEM—Templates • CSEC—Security • CMON—Monitoring • CDPY—Deployment • CREP—Reports • CGRP—Groups • CDIS—Discovery • CINV—Inventory • CGEN—Generic • CUPD—Firmware update • CFWS—Setup • CUSR—User audit messages • CJOB—Job info • CMSC—Miscellaneous -q—The sequence number from which the records must be displayed. Records older than this sequence number are displayed. -n—Specifies the number of records that must be displayed.
Input racadm cmcchangeover Example NA NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Modifies the configuration properties of the management module.
• Connect to I/O module 1 serial console: racadm connect -m switch-1 NOTE: When you run the racadm connect -m switch- command for the first time, the option to enter the user credentials is not displayed. Press Enter again to view the option to enter the user credentials. NOTE: Use quit key that is configured on the iDRAC to quit the console. NOTE: When you run the command, racadm connect -m switch-, the first time, the option to enter the user credentials is not displayed.
NOTE: You can configure only the "root" user password for servers, using the deploy • • • • • Example • command. -s— The sets static IPV4 network configuration for server. The , , and must be typed as dotted decimal strings. -s—The attribute string, -6 , sets static IPV6 network configuration for server. The attributes, and , must be entered as colon separated IPV6 strings.
Severity MessageId = Critical = CPU0003 SubSystem = PowerSupply Message = The power input of power supply 1 is lost. InstanceId = Fault#02200005#1 Severity = Critical MessageId = PSU0003 SubSystem = PowerSupply Message = The power input of power supply 5 is lost. InstanceId = Fault#02200006#1 Severity = Critical MessageId = PSU0005 getconfig Description Displays the configuration properties of OME - Modular.
• Display all available configuration groups: racadm getconfig -h getmodinfo Description Gets module configuration and status information. NOTE: If the Power Supply Unit (PSU) is absent, the RACADM interface displays the health state and power status for the PSU as N/A.
Synopsis Input racadm getpbinfo racadm getpbinfo Example racadm getpbinfo [Power Budget Status] System Input Power Peak System Power Peak System Power Timestamp Minimum System Power Minimum System Power Timestamp Overall Power Health Redundancy System Input Power Cap Redundancy Policy Dynamic PSU Engagement Enabled System Input Max Power Capacity Input Redundancy Reserve Input Power Allocated to Servers Input Power Allocated to Chassis Infrastructure Total Input Power Available for Allocation Standby Inp
A 5 1 6 1 7 1 8 1 N/A SLOT-5 PowerEdge SLOT-6 PowerEdge SLOT-7 PowerEdge SLOT-8 PowerEdge MX740c MX740c MX740c MX740c ON 227 W ON 228 W ON 240 W ON 622 W getpminfo Description Synopsis Input Example Gets power management status information.
Synopsis racadm getsensorinfo racadm getsensorinfo -c Input racadm getsensorinfo racadm getsensorinfo -c Where, -c—Compact output format Example • racadm getsensorinfo FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A FanSpeed A N/A Temp Celsius PWR PWR OK PWR PWR PWR OK PWR • 1 Not OK N/A rpm N/ OK 17166 rpm N/ OK 17250 rpm N/ OK 17096 rpm N
9 Fan-9 OK 14479 rpm Sensor Type: Temp 1 Chassis Inlet Temperature 47 Sensor Type: Power 1 PS-1 2 PS-2 3 PS-3 4 PS-4 5 PS-5 6 PS-6 N/A OK Slot Empty Online Slot Empty Online Configuration Error Input Lost N/A 27 N/A N/A OK Not OK Not OK C -7 OK getsysinfo Description Displays general RAC and system information.
Example To ping ip address 192.168.0.1 racadm ping 192.168.0.1 ping6 Description Sends ICMP echo packets on the network. Synopsis racadm ping6 Input —The IPv6 address of the remote endpoint to ping. Example To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racreset Description Resets the RAC. Synopsis racadm racreset racresetcfg Description Restores the RAC configuration to factory defaults.
• • • • • • powerdown—perform server power off powerup—perform server power on powercycle—perform server power cycle hardreset—force hard server power reset graceshutdown—perform graceful shutdown of server reseat—perform a virtual reseat of a server/storage NOTE: This action requires -f option to force the action.
Example • Enable DHCP for a switch: racadm setniccfg -m switch-1 -d • Configuration of switch to a static IPv4 address: racadm setniccfg -m switch-1 -s 192.168.0.120 255.255.255.0 192.168.0.1 • Configuration of chassis to a static IPv4 address: racadm setniccfg -m chassis -s 192.168.0.120 255.255.255.0 192.168.0.
3 OpenManage Enterprise Modular property database group and object descriptions You can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a configurable object, use the —o option. Topics: • • • • cfgLanNetworking cfgStorageModule cfgUserAdmin cfgRacTuning cfgLanNetworking This group contains parameters to configure OME-Modular NIC for IPv4. One instance of the group is allowed.
For Alternate DNS Server name use cfgDNSServer2 4. racadm config -g cfglannetworking -o cfgDNSRegisterRac 1 If step 1 is applied, to return to the original state. NOTE: You can modify the cfgDNSServer1 and cfgDNSServer2 only when cfgDNSServersFromDHCP is 0. Else, the static DNS server settings are ignored. NOTE: Disable Use DHCP for DNS Domain Name to configure the DNS Domain Name. NOTE: Configure the DNS Name, DNS Domain Name, and DNS server address before enabling Register with DNS.
NOTE: For IPv6, only the DHCPv6 address or static address is registered. Example: racadm getconfig -g cfgLanNetworking cfgDNSServersFromDHCP=1 cfgDNSServer1=192.168.0.5 cfgDNSServer2=192.168.0.6 cfgDNSRacName=cmc-frankly cfgDNSDomainName=fwad.lab cfgDNSDomainNameFromDHCP=1 cfgDNSRegisterRac=1 cfgDNSRacName (Read or Write) Description Displays the management module name, which is Service Tag by default. This parameter is only valid if cfgDNSRegisterRac is set to 1 (TRUE).
• • • NIC Enabled IPv6 Enabled Autoconfiguration Enabled The network administrator must ensure that these DHCP servers are configured to provide the same DNS domain name to the management module. Else, the domain name becomes unpredictable. cfgStorageModule Description This command is used only with the getconfig command.
Synopsis Input Example cfgStorageModuleServiceTag= cfgStorageModuleServiceTag= cfgStorageModuleServiceTag=MX0000 cfgStorageModuleAssetTag Description Synopsis Input Example Displays the asset tag. cfgStorageModuleAssetTag= cfgStorageModuleAssetTag cfgStorageModuleAssetTag=xxxxxx cfgConnectedSlots Description Synopsis Input Example Displays the connected slots.
Legal Values A string of up to 20 ASCII characters. The following characters are supported in a password: • • • • Default Uppercase letters Lowercase letters Numbers—0-9 Special characters—/, -, _, ., :, ,, [], " ******** cfgRacTuning This group is used to configure OME-Modular configuration properties, such as service tag or web server settings. Use this object with the config or getconfig subcommands.