Dell EMC OpenManage Enterprise Modular Edition Version 1.00.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2018 2019 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction....................................................................................................................................................5 Supported RACADM Interfaces....................................................................................................................................... 5 RACADM Command Options...........................................................................................................................................
cfgDNSRegisterRac (Read or Write)...................................................................................................................... 25 cfgDNSRacName (Read or Write)...........................................................................................................................25 cfgDNSDomainName (Read or Write).................................................................................................................... 25 cfgDNSDomainNameFromDHCP (Read or Write)..........
1 Introduction This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions for Dell EMC OpenManage Enterprise Modular (OME – Modular). Topics: • Supported RACADM Interfaces • RACADM Command Options • Other documents you may need Supported RACADM Interfaces The RACADM command-line utility provides a scriptable interface that allows you to configure your OME - Modular.
Option Description -m objectname Specifies the module. Table 2. Supported RACADM interfaces Type Local RACADM Address SSH RACADM Remote RACADM OME-Modular No Yes Yes NOTE: Multiple instances of remote RACADM can be run on a management station. Displayable Characters Displayable characters include the following set: • abcdefghijklmnopqrstuvwxwz • ABCDEFGHIJKLMNOPQRSTUVWXYZ • 0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/ Other documents you may need Table 3.
2 RACADM sub command details This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries.
• " (double quotation mark) • ` (backward quotation mark) • \ (backward slash) • ~ (tilde) • ; (semicolon) • | (vertical bar) • ( (left parentheses) • ) (right parentheses) • # (pound) • ASCII code 32 (space) NOTE: The - (dash) character cannot be the first character of the string, regardless of whether the string is quoted. There are different escaping rules for double quotation marks. There are different escaping rules for using single quotation mark and double quotation marks.
Synopsis Input • racadm ? • racadm ? racadm ? racadm ? Example Example for RACADM ? The following output example shows only part of the actual output for the racadm ? command. Descriptions shown in this example may vary slightly from the descriptions in your racadm session.
arp Description Displays the networking ARP table. Synopsis racadm arp Input racadm arp Example Table 4. racadm arp Address HWtype HWaddress Flags Mask Iface 192.168.0.120 ether 00:00:5e:00:01:01 C pub 192.168.1.120 ether 90:b1:1c:f4:32:09 C pub 192.168.0.121 ether 90:b1:1c:f4:34:f4 C pub chassisaction Description Executes the turn on, turn off, power cycle, or reset operation.
Synopsis Input Examples • racadm chassisgroup help add • racadm chassisgroup help view • racadm chassisgroup help admit • racadm chassisgroup help deny racadm chassisgroup • -m—IPv4 address of standalone chassis. • -l—IPv4 address of leader chassis. • -g—Name of the chassis group. • Executes on a leader, adds a standalone chassis to the group: racadm chassisgroup add -m 192.168.0.
Synopsis racadm cmcchangeover Input racadm cmcchangeover Example NA NOTE: During a failover, the chassis power state on the OME - Modular GUI is displayed as "off". The original power state is displayed after the inventory is refreshed. config Description Modifies RAC configuration properties.
deploy Description Deploys blade or IOM by specifying required properties. NOTE: The quick deploy command is not supported in RACADM.
• Set password for all switches racadm deploy -a switch -u root -p faultlist Description Displays the active error message in the chassis subsystem. Synopsis racadm faultlist view $ racadm faultlist view Example SubSystem = System.Modular.7 Message = CPU 1 is absent InstanceId = Fault#02200004#1 Severity = Critical MessageId = CPU0003 SubSystem = PowerSupply Message = The power input of power supply 1 is lost.
• Display a single object from a particular group: racadm getconfig -g cfgLanNetworking -o cfgDNSRacName • Display an indexed group: racadm getconfig -g cfgUserAdmin -o cfgUserAdminPassword -i 2 • Display information about the service tag of the storage module: racadm getconfig -g cfgStorageModule -mm storage-<1 to 8> -o cfgStorageModuleServiceTag • Display all available configuration groups: racadm getconfig -h getmodinfo Description Gets module configuration and status information.
getpbinfo Description Gets power budget status information. If there is no power supply to the PSU, the output of the command is displayed as "failed". If there is a mismatch in the power source, for example, a PSU of 220 volts and PSU of 110 volts are combined, then the output of the command is displayed as "Configuration Error".
Absent A N/A N/A [Server Module Power Allocation Table] ON SLOT-7 OFF 1 SLOT-3 1 lade Type> N/ ll EMC PowerEdge MX5016s 192 werEdge MX740c getpminfo Description Gets power management status information.
getsensorinfo Description Displays system sensors.
Sensor Type: Temp 1 Chassis Inlet Temperature OK Sensor Type: Power 1 PS-1 2 PS-2 3 PS-3 4 PS-4 5 PS-5 6 PS-6 Offline Slot Empty Slot Empty Online Slot Empty Slot Empty 27 C -7 47 Not OK N/A N/A OK N/A N/A getsysinfo Description Displays general RAC and system information.
Synopsis racadm ping6 Input —The IPv6 address of the remote endpoint to ping. Example To ping ipaddress FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racadm ping6 FE80:0000:0000:0000:0202:B3FF:FE1E:8329 racreset Description Resets the RAC. Synopsis racadm racreset racresetcfg Description Restores the RAC configuration to factory defaults.
Input Example • -m—The must be server-, where n = 1 to 8 • -a—Performs power action on all servers • Power action on a single server: racadm serveraction -m server-1 powerdown • Power action on all servers: racadm serveraction -a powerup • Reseat action on a single storage: racadm serveraction -m storage-2 -f reseat setniccfg Description Modifies network configuration properties.
Synopsis racadm swinventory Input racadm swinventory Example To view the software inventory: racadm swinventory traceroute Description Prints the route packets trace to the network host. Synopsis racadm traceroute Input —The IPv4 address or hostname of the remote endpoint to trace. Example To execute a trace route for IP address 192.168.0.2: racadm traceroute 192.168.0.2 traceroute6 Description Prints the route packets trace to the network host.
3 OME Modular property database group and object descriptions Replace this text with your content. Topics: • cfgLanNetworking • cfgStorageModule • cfgUserAdmin • cfgRacTuning cfgLanNetworking This group contains parameters to configure OME Modular NIC for IPv4. One instance of the group is allowed. Some objects in this group may require management module NIC to be reset, which may cause a brief loss in connectivity.
1 racadm config -g cfglannetworking -o cfgDNSRegisterRac 0 If Register with DNS is currently enabled. 2 racadm config -g cfglannetworking -o cfgDNSServersFromDHCP 0 3 racadm config -g cfglannetworking -o cfgDNSServer1 100.69.112.5 For Alternate DNS Server name use cfgDNSServer2. 4 racadm config -g cfglannetworking -o cfgDNSRegisterRac 1 To return to the original state if step 1 is applied. NOTE: You can modify the cfgDNSServer1 and cfgDNSServer2 only when cfgDNSServersFromDHCP is 0.
Legal Values String representing a valid IPv4 address. For example: 192.168.0.20. Default 0.0.0.0 cfgDNSRegisterRac (Read or Write) Description Legal Values Default Registers the iDRAC or management module name on the DNS server. When you set this parameter, the management module registers its DNS name for its IPv4 and IPv6 addresses with the DNS server. • 1 — True • 0 — False 0 NOTE: For IPv6, only the DHCPv6 address or static address is registered.
Default cfgDNSDomainNameFromDHCP (Read or Write) Description Legal Values Default Specifies that management module DNS domain name must be assigned from the network DHCP server. • 1 — True • 0 — False 0 This property is used only if cfgNicUseDhcp is set to 1(true), or if both cfgIPv6Enable and cfgIPv6AutoConfig are set to 1(true).
cfgStorageModuleStorageMode Description Displays the storage module. Synopsis cfgStorageModuleStorageMode= Input cfgStorageModuleStorageMode= NOTE: Example • If the storage mode is 1, then cfgConnectedSlots will be list of all connected slots to that particular enclosure. • If the storage mode is 2, then cfgConnectedSlots shows the assignment for each drive. cfgStorageModuleStorageMode=2 cfgStorageModuleServiceTag Description Displays the service tag.
Input cfgConnectedSlots= Example cfgConnectedSlots=2,2,2,2,2,2,2,2 cfgUserAdmin Description This group provides configuration information about the users who are allowed to access management module through the available remote interfaces. Up to 64 instances of the user group are allowed. Each instance represents the configuration for an individual user.
cfgRacTuneWebserverEnable (Read or Write) Description Legal Values Default Enables or disables the web server. If this property is disabled then it is not accessible using client web browsers. This property has no effect on the Telnet/SSH or racadm interfaces. • 1 (TRUE) • 0 (FALSE) 1 cfgRacTuneServiceTag Description Displays the service tag.