book.book Page 2 Tuesday, August 5, 2008 9:15 AM Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. ____________________ Information in this document is subject to change without notice. © 2003–2008 Dell Inc. All rights reserved. Reproduction in any manner whatsoever without the written permission of Dell Inc.
book.book Page 3 Tuesday, August 5, 2008 9:15 AM Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 17 Audience . . . . . . . . . . . . . . . . . . . . . . 17 What’s New in this Release . . . . . . . . . . . . . . . SNMP Versions supported for OpenManage 5.5 This section lists changes to the Server Administrator MIBs in this release of Server Administrator. . . . . . . . . . . . . . . . . . . 17 . . . 17 . . . . . 18 . . . . . . 18 . . . . . . . . . . . . . . . . . .
book.book Page 4 Tuesday, August 5, 2008 9:15 AM Introduction to the Server Administrator SNMP Subagent . . . . . . . . . . . . . . . . . . . . . . . . . 34 . . . . . . . . . . . . . . . . . . 35 . . . . . . . . . . . . . . . . . . . 37 SNMP MIB OIDs SNMP Security . . . . . . . . . . . . . . . 38 . . . . . . . . . . . . . . . . . . . . 38 Management Actions SNMP Traps 2 Instrumentation MIB Version Group . . . . 39 MIB Major Version Number . . . . . . . . . . . . . . .
book.book Page 5 Tuesday, August 5, 2008 9:15 AM Systems Management Software SNMP Agent Feature Flags . . . . . . . . . . . . . . . . . . Systems Management Software Manufacturer Name . . . . . . . . 45 . . . . . . . . . . 45 Systems Management Software Variable Values 4 . . . 45 System State Group . . . . . . . . . . . . . . . . . 47 System State Group Table . . . . . . . . . . . . . . . . 47 . . . . . . . . . . . . . . . . . 47 System State Table 5 Chassis Information Group . . . . .
book.book Page 6 Tuesday, August 5, 2008 9:15 AM System Resource Input/Output (I/O) Port Table . . . 128 System Resource Memory Table . . . . . . . . . . 131 System Resource Interrupt Table . . . . . . . . . 134 System Resource Direct Memory Access (DMA) Table . . . . . . . . . . . . . . . System Resource Group Variable Values 8 Power Group 140 . . . . . . . . . . . . . . . . . . 145 145 145 Power Supply Table . . . . . . . . . . . . . . . . 148 Voltage Probe Table . . . . . . . . . . .
book.book Page 7 Tuesday, August 5, 2008 9:15 AM 11 Remote Flash BIOS Group . Remote Flash BIOS Group Table Remote Flash BIOS Table 207 . . . . . . . . . . . . . 207 213 219 . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 . . . . . . . . . . . . . . . . . 225 Memory Device Port Table . Small Computer System Interface (SCSI) Port Table . . . . . . . . . . . . . . . . . . . . . . 228 . . . . . . . . . . . . . . . . . 230 . . . . . . . . . . . . . . . . . .
book.book Page 8 Tuesday, August 5, 2008 9:15 AM PCI Device Configuration Space Table . Network Device Table . . . . . . 285 . . . . . . . . . . . . . . . 288 Device Group Variable Values 14 Slot Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Slot Group Table . System Slot Table . 317 . . . . . . . . . . . . . . . . . 317 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Physical Memory Tables . . . . . . . . . . . . . . . .
book.book Page 9 Tuesday, August 5, 2008 9:15 AM 17 Local Response Agent Group LRA Group Tables . . . . . . . . 389 389 . . . . . . . . . . . . . . . . . . . . LRA Global Settings LRA Action Table 389 . . . . . . . . . . . . . . . . LRA Global Settings Table . . . . . . . . . . . . . 390 . . . . . . . . . . . . . . . . . . 392 Local Response Agent Variable Values . 18 Cost of Ownership Group . . . . . . . . . . . Cost of Ownership Group Tables Cost of Ownership Table 397 . . . . . . . . .
book.book Page 10 Tuesday, August 5, 2008 9:15 AM Remote User Dial-In Configuration Table Remote Dial-Out Table . . . . . 464 . . . . . . . . . . . . . . . 467 Remote Access Variable Values 20 Cluster Group Cluster Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cluster Table . . . . . . . . . . . . . . . . . . . . Cluster Group Variable Values . . . . . . . . . . . . . 21 Baseboard Management Controller Group . . . . . . . . .
book.book Page 11 Tuesday, August 5, 2008 9:15 AM Global Data Group . 514 . . . . . . . . . . . . . . . . . . . Physical Devices Group Controller Table . . . . . . . . . . . . . . . . . 520 . . . . . . . . . . . . . . . . . . 521 . . . . . . . . . . . . . . . . . . . 538 Enclosure Table . . . . . . . . . . . . . . . . . . 543 Array Disk Table . . . . . . . . . . . . . . . . . . 553 Channel Table . . . . . . 565 . . . . . . . 567 . . . . . . . . . . . . . . . . . . . . . .
book.book Page 12 Tuesday, August 5, 2008 9:15 AM Operating System Group . . . . . . . . . . . . . . . . . Inventory Collector Product Information 25 Dell RAC Out-of-Band Group . Product Information . . . . . . . . . . . . . . . . . 630 633 633 633 DRsProductShortName . . . . . . . . . . . . . . 633 DRsProductDescription . . . . . . . . . . . . . . 634 . . . . . . . . . . . . . 634 . . . . . . . . . . . . . . . . 634 DRsProductManufacturer DRsProductVersion . . . . . . . . . . . . . . . .
book.book Page 13 Tuesday, August 5, 2008 9:15 AM DRsIOMPrevStatus . . . . . . . . . . . . . . . . . 640 DRsKVMPrevStatus . . . . . . . . . . . . . . . . 640 . . . . . . . . . . . . . . . . . 640 DRsRedPrevStatus . . . . . . . . . . . . . . . 641 . . . . . . . . . . . . . . . . . 641 DRsPowerPrevStatus DRsFanPrevStatus DRsBladePrevStatus . . . . . . . . . . . . . . . . 641 DRsTempPrevStatus . . . . . . . . . . . . . . . . 641 DRsCMCPrevStatus . . . . . . . . . . . . . . . .
book.book Page 14 Tuesday, August 5, 2008 9:15 AM DRsWattsMinTime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648 DRsWattsReading . . . . . . . . . . . . . . . . . 649 DRsAmpsReading . . . . . . . . . . . . . . . . . 649 . . . . . . . . . . . . . . . . . . 649 DRsWattsResetTime CMC PSU Information DRsPSUChassisIndex DRsPSUIndex . . . . . . . . . . . . . . . . 649 . . . . . . . . . . . . . . . . . . . 650 DRsPSULocation . . . . . . . . . . . . . . . . . . . . . . . .
book.book Page 15 Tuesday, August 5, 2008 9:15 AM Current Status . . . . . . . . . . . . . . . . . . . 657 . . . . . . . . . . . . . . . . . . 657 . . . . . . . . . . . . . . . . . . . . . . . . 657 Previous Status Data . . . . . . . . . . 658 . . . . . . . . . . . . . . 662 . . . . . . . . . . . . . . . . . . 662 Understanding the Trap Description Understanding Trap Severity Instrumentation Traps Miscellaneous Traps . . . . . . . . . . . . . 664 . . . . . . . . . . . . . . . 666 . . .
book.book Page 16 Tuesday, August 5, 2008 9:15 AM SNMP Support for Storage Management Alerts . . . . 701 . . . . . . . . . . . . . . 701 SNMP Trap Definitions . . . . . . . . . . . . . . . 701 SNMP Trap Variables . . . . . . . . . . . . . . . . 702 . . . . . . . . . . . . . . . . . . 702 SNMP Trap Forwarding Viewing SNMP Traps Alert Descriptions and Corrective Actions A Standard Data Type Definitions Common Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
book.book Page 17 Tuesday, August 5, 2008 9:15 AM Introduction This introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide," explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time.
book.book Page 18 Tuesday, August 5, 2008 9:15 AM What's New in the Instrumentation MIB • • Added the MIB objects to the Chassis Information Table: – Chassis System Properties – Chassis System Revision Number – Chassis System Revision Name Added the enumeration to the Chassis Information Table: – System Properties What's New in the Dell RAC Out-of-Band MIB NOTE: The Dell™ RAC Out-of-Band MIB also defines the Chassis Management Controller (CMC) objects and traps.
book.book Page 19 Tuesday, August 5, 2008 9:15 AM General Content Table 1-1 describes the sections that provide general information about the MIBs documented in this guide. Table 1-1.
book.book Page 20 Tuesday, August 5, 2008 9:15 AM The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-2 describes each Server Administrator Instrumentation MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.
book.book Page 21 Tuesday, August 5, 2008 9:15 AM Table 1-2.
book.book Page 22 Tuesday, August 5, 2008 9:15 AM Server Administrator Remote Access MIB The Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information about remote access hardware that may be present in your system. The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information.
book.book Page 23 Tuesday, August 5, 2008 9:15 AM The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-4 describes each Server Administrator Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.
book.book Page 24 Tuesday, August 5, 2008 9:15 AM Table 1-5.
book.book Page 25 Tuesday, August 5, 2008 9:15 AM Table 1-6. Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change Management Group - describes the inventory 10899 data provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis Dell RAC Out-of-Band MIB The Dell RAC Out-of-Band MIB (filename dellRAC.
book.book Page 26 Tuesday, August 5, 2008 9:15 AM Table 1-8. Where to Find Definitions for Technical Terms Type of Definition See Basic SNMP vocabulary. Introduction MIB-group-specific variable values. MIB-groupspecific MIB variables contain links to the tables that define these values in the last section of the section in which these variables are used. Sections 3, 5, 7, 8, 9, and 11 through 18.
book.book Page 27 Tuesday, August 5, 2008 9:15 AM On supported operating systems, the SNMP master agent is provided with the operating system. For example, on supported Microsoft® Windows® operating systems, the Windows SNMP service is the SNMP master agent. For information on the versions of the SNMP protocol supported by the SNMP master agent, see the operating system documentation.
book.book Page 28 Tuesday, August 5, 2008 9:15 AM One-Based Index When an index is one-based, counting starts at 1. One-based indexing counts the first instance as 1, the second index as 2, and so on. Zero-Based Index When an index is zero-based, counting starts at 0. Zero-based indexing counts the first instance as 0, the second index as 1, and so on. Fields Managed object variables contain fields.
book.book Page 29 Tuesday, August 5, 2008 9:15 AM temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the temperatureProbeLocation. For more information about the structure of OIDs, see "SNMP MIB OIDs." Description is a brief explanation of what a particular managed object does. Syntax defines the data type in which the values of the variable must be expressed. Most variables in this reference guide use standard data types such as string or boolean.
book.book Page 30 Tuesday, August 5, 2008 9:15 AM Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays.
book.book Page 31 Tuesday, August 5, 2008 9:15 AM UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.
book.book Page 32 Tuesday, August 5, 2008 9:15 AM UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax OCTET STRING (SIZE[16]) Access Read-only Reference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administratorspecific. Industry-standard variable definitions are documented in "Standard Data Type Definitions.
book.book Page 33 Tuesday, August 5, 2008 9:15 AM Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group. If the group is defined by one or more tables, the second section lists these tables. The third section documents the variables that comprise the group, and if applicable, the variables that comprise the tables.
book.book Page 34 Tuesday, August 5, 2008 9:15 AM Other Documents You May Need In addition to this Server Administrator SNMP Reference Guide, you can find the following guides on your Dell Systems Management Tools and Documentation DVD: • The Server Administrator Messages Reference Guide lists the messages that you can receive on your systems management console or on your operating system’s event viewer.
book.book Page 35 Tuesday, August 5, 2008 9:15 AM SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems. SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was published in August 1988 and is the most commonly supported version of SNMP.
book.book Page 36 Tuesday, August 5, 2008 9:15 AM The first component, 011, is the country code for the United States. The second component, 512, identifies the area code for central Texas. The third component, 471, is the phone exchange for a large state university in the city of Austin. The final component, 0000, is the main switchboard. There are two main differences between the phone number example and an actual OID. The first difference is that there are many more components in an OID, up to 128.
book.book Page 37 Tuesday, August 5, 2008 9:15 AM In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
book.book Page 38 Tuesday, August 5, 2008 9:15 AM Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security," for limitations on Set operations. SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on.
book.book Page 39 Tuesday, August 5, 2008 9:15 AM Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.
book.book Page 40 Tuesday, August 5, 2008 9:15 AM MIB Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes.
book.book Page 41 Tuesday, August 5, 2008 9:15 AM Systems Management Software Group The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
book.book Page 42 Tuesday, August 5, 2008 9:15 AM Systems Management Software The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table. Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 43 Tuesday, August 5, 2008 9:15 AM Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software. Syntax DellString Access Read-only Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 44 Tuesday, August 5, 2008 9:15 AM Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 45 Tuesday, August 5, 2008 9:15 AM Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.12 Description Defines the features of the SNMP agent software provided by the operating system. Syntax SMSSNMPAgentFeatureFlags (See Table 3-3) Access Read-only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.
book.book Page 46 Tuesday, August 5, 2008 9:15 AM Table 3-2. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementPreferred(1) The web 1:1 management preferred feature is enabled. Table 3-3.
book.book Page 47 Tuesday, August 5, 2008 9:15 AM System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.
book.book Page 48 Tuesday, August 5, 2008 9:15 AM System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance.
book.book Page 49 Tuesday, August 5, 2008 9:15 AM System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit.
book.book Page 50 Tuesday, August 5, 2008 9:15 AM System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply.
book.book Page 51 Tuesday, August 5, 2008 9:15 AM System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe.
book.book Page 52 Tuesday, August 5, 2008 9:15 AM System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe.
book.book Page 53 Tuesday, August 5, 2008 9:15 AM System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit.
book.book Page 54 Tuesday, August 5, 2008 9:15 AM System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device.
book.book Page 55 Tuesday, August 5, 2008 9:15 AM System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe.
book.book Page 56 Tuesday, August 5, 2008 9:15 AM System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device.
book.book Page 57 Tuesday, August 5, 2008 9:15 AM System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
book.book Page 58 Tuesday, August 5, 2008 9:15 AM System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax OCTET STRING (SIZE(1..
book.book Page 59 Tuesday, August 5, 2008 9:15 AM System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax OCTET STRING (SIZE(1..
book.book Page 60 Tuesday, August 5, 2008 9:15 AM System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on.
book.book Page 61 Tuesday, August 5, 2008 9:15 AM System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
book.book Page 62 Tuesday, August 5, 2008 9:15 AM System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis.
book.book Page 63 Tuesday, August 5, 2008 9:15 AM System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on.
book.book Page 64 Tuesday, August 5, 2008 9:15 AM System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
book.book Page 65 Tuesday, August 5, 2008 9:15 AM System State Battery Status List Name systemStateBatteryStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.53 Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus.
book.
book.book Page 67 Tuesday, August 5, 2008 9:15 AM Chassis Information Group The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
book.book Page 68 Tuesday, August 5, 2008 9:15 AM Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 69 Tuesday, August 5, 2008 9:15 AM Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any.
book.book Page 70 Tuesday, August 5, 2008 9:15 AM Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.
book.book Page 71 Tuesday, August 5, 2008 9:15 AM Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.
book.book Page 72 Tuesday, August 5, 2008 9:15 AM Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system.
book.book Page 73 Tuesday, August 5, 2008 9:15 AM Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 74 Tuesday, August 5, 2008 9:15 AM Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 5-5.) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 75 Tuesday, August 5, 2008 9:15 AM Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 5-9.) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 76 Tuesday, August 5, 2008 9:15 AM Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 5-12.) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 77 Tuesday, August 5, 2008 9:15 AM Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 78 Tuesday, August 5, 2008 9:15 AM Chassis Power Button Control Settings Unique Name chassisPowerButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.39 Description Defines the current reading and allows setting of the power button control hardware. Syntax DellPowerButtonControlSettings (See Table 5-17) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 79 Tuesday, August 5, 2008 9:15 AM Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. Syntax DellUnsigned16BitRange Access Read-only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
book.book Page 80 Tuesday, August 5, 2008 9:15 AM Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
book.book Page 81 Tuesday, August 5, 2008 9:15 AM UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.
book.book Page 82 Tuesday, August 5, 2008 9:15 AM UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax OCTET STRING (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads.
book.book Page 83 Tuesday, August 5, 2008 9:15 AM POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log.
book.book Page 84 Tuesday, August 5, 2008 9:15 AM POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Table 5-1.
book.book Page 85 Tuesday, August 5, 2008 9:15 AM Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log.
book.book Page 86 Tuesday, August 5, 2008 9:15 AM Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Event Log Format Name eventLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6 Description Defines the format of the event log. Syntax DellLogFormat (See Table 5-1.
book.book Page 87 Tuesday, August 5, 2008 9:15 AM System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table. Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible System BIOS Table Entry Name systemBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.50.1 Description Defines the System BIOS Table entry.
book.book Page 88 Tuesday, August 5, 2008 9:15 AM System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object. Syntax DellStateCapabilities Access Read-only System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object.
book.book Page 89 Tuesday, August 5, 2008 9:15 AM System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8 Description Defines the version name of the system BIOS.
book.book Page 90 Tuesday, August 5, 2008 9:15 AM System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS.
book.book Page 91 Tuesday, August 5, 2008 9:15 AM Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card (PCMCIA) is supported Bit 19EDD (Enhanced Disk Drive) Specification is supported Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.
book.book Page 92 Tuesday, August 5, 2008 9:15 AM System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 93 Tuesday, August 5, 2008 9:15 AM Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry.
book.book Page 94 Tuesday, August 5, 2008 9:15 AM Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware.
book.book Page 95 Tuesday, August 5, 2008 9:15 AM Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
book.book Page 96 Tuesday, August 5, 2008 9:15 AM Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.
book.book Page 97 Tuesday, August 5, 2008 9:15 AM Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object.
book.book Page 98 Tuesday, August 5, 2008 9:15 AM Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.
book.book Page 99 Tuesday, August 5, 2008 9:15 AM Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex, baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 100 Tuesday, August 5, 2008 9:15 AM Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-write Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.
book.book Page 101 Tuesday, August 5, 2008 9:15 AM Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard. Syntax DellString Access Read-only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.
book.book Page 102 Tuesday, August 5, 2008 9:15 AM Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name. Syntax DellString Access Read-only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name.
book.book Page 103 Tuesday, August 5, 2008 9:15 AM Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 5-1. Log Format Variable Name: DellLogFormat Data Type: Integer Possible Data Values Meaning of Data Value raw(1) The log is in the format received from the firmware. ascii(2) The log is in ASCII format. uniCode(3) The log is in Unicode format. Table 5-2.
book.book Page 104 Tuesday, August 5, 2008 9:15 AM Table 5-2. Chassis Type (continued) Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value subNoteBook(14) The chassis type is a subnotebook. spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassis(17) The chassis type is the main system chassis. expansionChassis(18) The chassis type is an expansion chassis.
book.book Page 105 Tuesday, August 5, 2008 9:15 AM Table 5-4. Fan Control Capabilities Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrHighSpeedCapable(6) The fan can be set to low or high speed. Table 5-5.
book.book Page 106 Tuesday, August 5, 2008 9:15 AM Table 5-7. Hard-Drive Fault LED Control Capabilities Variable Name: DellHDFaultLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilities(1) The hard-drive fault LED capabilities are unknown. enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
book.book Page 107 Tuesday, August 5, 2008 9:15 AM Table 5-9. Chassis Identification Control Capabilities Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities(1) The chassis identification control’s capabilities are unknown.
book.book Page 108 Tuesday, August 5, 2008 9:15 AM Table 5-10. Chassis Identification Control Settings (continued) Variable Name: DellChassisIdentifyControlSettings Data Type: Integer Possible Data Values Meaning of Data Value identifyChassis(8) The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1.
book.book Page 109 Tuesday, August 5, 2008 9:15 AM Table 5-12. Host Control Settings Variable Name: DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualReboot(1) The operator can reboot the host. manualPowerOFF(2) The operator can power off the host. manualPowerCycle(4) Power cycle the host. manualOperatingSystemShutdown The operator can shut down the (8) operating system on the host.
book.book Page 110 Tuesday, August 5, 2008 9:15 AM Table 5-13. Watchdog Control Capabilities (continued) Variable Name: DellWatchDogControlCapabilities NOTE: When the system determines that the operating system is not responding, it will automatically perform the selected action without operator intervention. Data Type: Integer Possible Data Values Meaning of Data Value automaticWatchDogTimerCapable Watchdog controls can be set to (8) function automatically.
book.book Page 111 Tuesday, August 5, 2008 9:15 AM Table 5-15. Watchdog Timer Capabilities Variable Name: DellWatchDogTimerCapabilities Data Type: Integer Possible Data Values Meaning of Data Value type1Capable(1) Watchdog timer can time in intervals from 20–480 seconds. type2Capable(2) Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals. type3Capable(4) Watchdog timer can time in 60-second intervals. Table 5-16.
book.book Page 112 Tuesday, August 5, 2008 9:15 AM Table 5-18. NMI Button Control Capabilities Variable Name: DellNMIButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no capabilities. unknownCapabilities(1) The NMI button capabilities are unknown. The NMI button can be enabled (online) or disabled (offline). enableCapable(2) Table 5-19.
book.book Page 113 Tuesday, August 5, 2008 9:15 AM Table 5-21. Chassis System Class Variable Name: DellChassisSystemClass Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis system class is not one of the following: unknown(2) The chassis system class is unknown. workstationClass(3) The chassis system class is a workstation. serverClass(4) The chassis system class is a server. desktopClass(5) The chassis system class is a desktop.
book.book Page 114 Tuesday, August 5, 2008 9:15 AM Table 5-22. Firmware Type (continued) Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value frontPanel(9) The firmware type is Front Panel Controller. baseboardManagementController The firmware type is Baseboard (10) Management Controller. hotPlugPCI(11) The firmware type is Hot Plug Peripheral Component Interconnect (PCI) Controller. sensorData(12) The firmware type is Sensor Data Records.
book.book Page 115 Tuesday, August 5, 2008 9:15 AM Table 5-23. Baseboard Type (continued) Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value systemManagementModule(5) The baseboard type is a system management module. processorModule(6) The baseboard type is a processor module. ioModule(7) The baseboard type is an I/O module. memoryModule(8) The baseboard type is a memory module daughterBoard(9) The baseboard type is a daughter board.
book.
book.book Page 117 Tuesday, August 5, 2008 9:15 AM Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.
book.book Page 118 Tuesday, August 5, 2008 9:15 AM Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system.
book.book Page 119 Tuesday, August 5, 2008 9:15 AM Operating System Is Primary Name operatingSystemIsPrimary Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5 Description Specifies whether this operating system is the primary operating system. Syntax DellBoolean Access Read-only Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DisplayString (SIZE (0..
book.book Page 120 Tuesday, August 5, 2008 9:15 AM Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.
book.book Page 121 Tuesday, August 5, 2008 9:15 AM Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in bytes.
book.book Page 122 Tuesday, August 5, 2008 9:15 AM Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in bytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in bytes.
book.book Page 123 Tuesday, August 5, 2008 9:15 AM System Resource Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
book.book Page 124 Tuesday, August 5, 2008 9:15 AM System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex, systemResourceMapIndex System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.
book.book Page 125 Tuesday, August 5, 2008 9:15 AM System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-write System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map.
book.book Page 126 Tuesday, August 5, 2008 9:15 AM System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex, systemResourceOwnerIndex System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.
book.book Page 127 Tuesday, August 5, 2008 9:15 AM System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner. Syntax DellStateSettings Access Read-write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner.
book.book Page 128 Tuesday, August 5, 2008 9:15 AM System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner. Syntax DellString Access Read-only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
book.book Page 129 Tuesday, August 5, 2008 9:15 AM System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis.
book.book Page 130 Tuesday, August 5, 2008 9:15 AM System Resource I/O Port Status Name systemResourceIOPortStatus Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5 Description Defines the status of the system resource I/O port. Syntax DellStateSettings Access Read-only System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis.
book.book Page 131 Tuesday, August 5, 2008 9:15 AM System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table.
book.book Page 132 Tuesday, August 5, 2008 9:15 AM System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory.
book.book Page 133 Tuesday, August 5, 2008 9:15 AM System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
book.book Page 134 Tuesday, August 5, 2008 9:15 AM System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (See Table 7-4.) Access Read-only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table.
book.book Page 135 Tuesday, August 5, 2008 9:15 AM System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt.
book.book Page 136 Tuesday, August 5, 2008 9:15 AM System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
book.book Page 137 Tuesday, August 5, 2008 9:15 AM System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (See Table 7-6.) Access Read-only System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table.
book.book Page 138 Tuesday, August 5, 2008 9:15 AM System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA.
book.book Page 139 Tuesday, August 5, 2008 9:15 AM System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.
book.book Page 140 Tuesday, August 5, 2008 9:15 AM System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10 Description Defines the bus mastering capabilities of the system resource DMA. Syntax DellResourceDMABusMaster (See Table 7-7.) Access Read-only System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 7-1.
book.book Page 141 Tuesday, August 5, 2008 9:15 AM Table 7-2. Resource Owner Interface Type (continued) Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 7-3.
book.book Page 142 Tuesday, August 5, 2008 9:15 AM Table 7-5. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1) The interrupt type is level sensitive. The interrupt type is latched. interruptIsLatched(2) Table 7-6.
book.book Page 143 Tuesday, August 5, 2008 9:15 AM Table 7-8. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2) The DMA transfer width is unknown. dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits. dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.
book.
book.book Page 145 Tuesday, August 5, 2008 9:15 AM Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.
book.book Page 146 Tuesday, August 5, 2008 9:15 AM Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 147 Tuesday, August 5, 2008 9:15 AM Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-write Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit.
book.book Page 148 Tuesday, August 5, 2008 9:15 AM Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.
book.book Page 149 Tuesday, August 5, 2008 9:15 AM Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (See Table 8-1.
book.book Page 150 Tuesday, August 5, 2008 9:15 AM Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (See Table 8-3.
book.book Page 151 Tuesday, August 5, 2008 9:15 AM Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis. Syntax DellObjectRange Access Read-only Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
book.book Page 152 Tuesday, August 5, 2008 9:15 AM Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table. Syntax VoltageProbeTableEntry Access Not accessible Voltage Probe Table Entry Name voltageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.20.1 Description Defines the Voltage Probe Table entry.
book.book Page 153 Tuesday, August 5, 2008 9:15 AM Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.4 Description Defines the state and settings of the voltage probe.
book.book Page 154 Tuesday, August 5, 2008 9:15 AM Voltage Probe Type Name voltageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.7 Description Defines the type of the voltage probe. Syntax DellVoltageType Access Read-only Voltage Probe Location Name Name voltageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.8 Description Defines the location of the voltage probe in this chassis.
book.book Page 155 Tuesday, August 5, 2008 9:15 AM Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
book.book Page 156 Tuesday, August 5, 2008 9:15 AM Voltage Probe Probe Capabilities Name voltageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.15 Description Defines the probe capabilities of the voltage probe. Syntax DellProbeCapabilities Access Read-only Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete.
book.book Page 157 Tuesday, August 5, 2008 9:15 AM Amperage Probe Table Entry Name amperageProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.30.1 Description Defines the Amperage Probe Table entry. Syntax AmperageProbeTableEntry Access Not accessible Index amperageProbechassisIndex, amperageProbeIndex Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 158 Tuesday, August 5, 2008 9:15 AM Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe. Syntax DellStateSettings Access Read-write Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe.
book.book Page 159 Tuesday, August 5, 2008 9:15 AM Name amperageProbeReading When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, amperageProbeTypeIsPowerSupplyAmps, amperageProbeTypeIsPowerSupplyWatts, amperageProbeTypeIsSystemAmps, or amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 160 Tuesday, August 5, 2008 9:15 AM Amperage Probe Upper Nonrecoverable Threshold Name amperageProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.9 Description Defines the value of the amperage probe’s upper nonrecoverable threshold. The value is an integer representing the amperage in milliamperes that the probe is reading.
book.book Page 161 Tuesday, August 5, 2008 9:15 AM Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.13 Description Defines the value of the amperage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
book.book Page 162 Tuesday, August 5, 2008 9:15 AM Amperage Probe Discrete Reading Name amperageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.16 Description Defines the reading for a amperage probe of type amperageProbeTypeIsDiscrete. When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute.
book.book Page 163 Tuesday, August 5, 2008 9:15 AM AC Power Switch Chassis Index Name aCPowerSwitchChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.1 Description Defines the index (one-based) of the chassis containing this AC power switch. Syntax DellObjectRange Access Read-only AC Power Switch Index Name aCPowerSwitchIndex Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.2 Description Defines the index (one-based) of this AC power switch.
book.book Page 164 Tuesday, August 5, 2008 9:15 AM AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch. Syntax DellStatusRedundancy Access Read-only AC Power Cord Count for Redundancy Name aCPowerCordCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.
book.book Page 165 Tuesday, August 5, 2008 9:15 AM AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table.
book.book Page 166 Tuesday, August 5, 2008 9:15 AM AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord.
book.book Page 167 Tuesday, August 5, 2008 9:15 AM AC Power Cord AC Power Switch Index Reference Name aCPowerCordaCPowerSwitchIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.6 Description Defines the index (one-based) to the associated AC power switch for this AC power cord. Syntax DellObjectRange Access Read-only AC Power Cord Location Name Name aCPowerCordLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.7 Description Defines the location name of this AC power cord.
book.book Page 168 Tuesday, August 5, 2008 9:15 AM Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery.
book.book Page 169 Tuesday, August 5, 2008 9:15 AM Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (see Table 8-15) Access Read-only Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.
book.book Page 170 Tuesday, August 5, 2008 9:15 AM Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex, powerUsageIndex Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 171 Tuesday, August 5, 2008 9:15 AM Power Usage State Settings Name powerUsageStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.4 Description Defines the state settings of the power usage information. Syntax DellStateSettings Access Read-write Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information.
book.book Page 172 Tuesday, August 5, 2008 9:15 AM Power Usage Cumulative Wattage Start Date Name Name powerUsageCumulativeWattageStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.8 Description Defines the date and time at which the data collection started for the value reported by the powerUsageCumulativeWattage attribute. Syntax DellDateName Access Read-only Power Usage Peak Watts Name powerUsagePeakWatts Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 173 Tuesday, August 5, 2008 9:15 AM Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.11 Description Defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. Syntax DellDateName Access Read-only Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
book.book Page 174 Tuesday, August 5, 2008 9:15 AM Power Usage Peak Amps Reading Date Name Name powerUsagePeakAmpsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.14 Description Defines the date and time at which the value reported by the powerUsagePeakAmps attribute was measured. Syntax DellDateName Access Read-only Power Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 8-1.
book.book Page 175 Tuesday, August 5, 2008 9:15 AM Table 8-2. Power Supply State Settings Unique (continued) Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working. powerSupplyIsON(16) The power supply is indicating that it is on. powerSupplyIsOk(32) The power supply is indicating that it is OK.
book.book Page 176 Tuesday, August 5, 2008 9:15 AM Table 8-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply.
book.book Page 177 Tuesday, August 5, 2008 9:15 AM Table 8-4. Power Supply Sensor State (continued) Variable Name: DellPowerSupplySensorState Data Type: Integer Possible Data Values Meaning of Data Value acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range. configurationError(64) Table 8-5. The power supply sensor detects a configuration error.
book.book Page 178 Tuesday, August 5, 2008 9:15 AM Table 8-6. Voltage Probe Type (continued) Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe. (4) voltageProbeTypeIs5Volt(5) The voltage probe type is a 5-V probe. voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe. (6) voltageProbeTypeIs12Volt(7) The voltage probe type is a 12-V probe.
book.book Page 179 Tuesday, August 5, 2008 9:15 AM Table 8-7. Voltage Probe Discrete Reading Variable Name: DellVoltageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value voltageIsGood(1) The voltage probe discrete reading is good. voltageIsBad(2) The voltage probe discrete reading is bad. Table 8-8.
book.book Page 180 Tuesday, August 5, 2008 9:15 AM Table 8-8. Amperage Probe Definitions (continued) Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsFLEA(11) The amperage probe type is a FLEA (standby) amperage probe. amperageProbeTypeIsBattery(12) The amperage probe type is a battery amperage probe. amperageProbeTypeIsTerminator(13) The amperage probe type is a Small Computer System Interface (SCSI) termination amperage probe.
book.book Page 181 Tuesday, August 5, 2008 9:15 AM Table 8-9. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. Table 8-10.
book.book Page 182 Tuesday, August 5, 2008 9:15 AM Table 8-11. AC Power Switch Settings (continued) Variable Name: DellACPowerSwitchSettings Data Type: Integer Possible Data Values Meaning of Data Value inputSourceCord1Return(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return. inputSourceCord2Return(16) Input source is AC power cord 2, with return. inputSourceShared(32) Input source is shared. Table 8-12.
book.book Page 183 Tuesday, August 5, 2008 9:15 AM Table 8-14. AC Power Cord State Settings Variable Name: DellACPowerCordStateSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s state is unknown. online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1. notReady(4) The AC power cord’s state is not ready. acPowerCordHasPower The AC power cord has power.
book.
book.book Page 185 Tuesday, August 5, 2008 9:15 AM Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
book.book Page 186 Tuesday, August 5, 2008 9:15 AM Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units.
book.book Page 187 Tuesday, August 5, 2008 9:15 AM Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy.
book.book Page 188 Tuesday, August 5, 2008 9:15 AM Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
book.book Page 189 Tuesday, August 5, 2008 9:15 AM Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device.
book.book Page 190 Tuesday, August 5, 2008 9:15 AM Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device.
book.book Page 191 Tuesday, August 5, 2008 9:15 AM Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 192 Tuesday, August 5, 2008 9:15 AM Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
book.book Page 193 Tuesday, August 5, 2008 9:15 AM Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17 Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete.
book.book Page 194 Tuesday, August 5, 2008 9:15 AM Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex, temperatureProbeIndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 195 Tuesday, August 5, 2008 9:15 AM Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
book.book Page 196 Tuesday, August 5, 2008 9:15 AM Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 9-4.) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis.
book.book Page 197 Tuesday, August 5, 2008 9:15 AM Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 198 Tuesday, August 5, 2008 9:15 AM Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
book.book Page 199 Tuesday, August 5, 2008 9:15 AM Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 9-1. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored).
book.book Page 200 Tuesday, August 5, 2008 9:15 AM Table 9-2. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM(3) fan that reads in RPMs.
book.book Page 201 Tuesday, August 5, 2008 9:15 AM Table 9-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
book.
book.book Page 203 Tuesday, August 5, 2008 9:15 AM User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 204 Tuesday, August 5, 2008 9:15 AM User Security Chassis Index Name userSecuritychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.1 Description Defines the user security index (one-based) of this chassis. Syntax DellObjectRange Access Read-only User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index.
book.book Page 205 Tuesday, August 5, 2008 9:15 AM User Security Request Name Name userSecurityRequestName Object ID 1.3.6.1.4.1.674.10892.1.800.1.5 Description Defines a request name used for creating, deleting, and editing users.
book.
book.book Page 207 Tuesday, August 5, 2008 9:15 AM Remote Flash BIOS Group The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Name remoteFlashBIOSTable Object ID 1.3.
book.book Page 208 Tuesday, August 5, 2008 9:15 AM Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
book.book Page 209 Tuesday, August 5, 2008 9:15 AM Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update.
book.book Page 210 Tuesday, August 5, 2008 9:15 AM Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 11-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown.
book.book Page 211 Tuesday, August 5, 2008 9:15 AM Table 11-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully.
book.
book.book Page 213 Tuesday, August 5, 2008 9:15 AM Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
book.book Page 214 Tuesday, August 5, 2008 9:15 AM Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 215 Tuesday, August 5, 2008 9:15 AM Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port.
book.book Page 216 Tuesday, August 5, 2008 9:15 AM Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port.
book.book Page 217 Tuesday, August 5, 2008 9:15 AM Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis.
book.book Page 218 Tuesday, August 5, 2008 9:15 AM Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port.
book.book Page 219 Tuesday, August 5, 2008 9:15 AM Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
book.book Page 220 Tuesday, August 5, 2008 9:15 AM Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port.
book.book Page 221 Tuesday, August 5, 2008 9:15 AM Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port. Syntax DellProcessorPortConnectorType (See Table 12-3.
book.book Page 222 Tuesday, August 5, 2008 9:15 AM Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
book.book Page 223 Tuesday, August 5, 2008 9:15 AM Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port.
book.book Page 224 Tuesday, August 5, 2008 9:15 AM Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 12-4.) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
book.book Page 225 Tuesday, August 5, 2008 9:15 AM Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any).
book.book Page 226 Tuesday, August 5, 2008 9:15 AM Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port.
book.book Page 227 Tuesday, August 5, 2008 9:15 AM Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Table 12-5.
book.book Page 228 Tuesday, August 5, 2008 9:15 AM Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry.
book.book Page 229 Tuesday, August 5, 2008 9:15 AM SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port.
book.book Page 230 Tuesday, August 5, 2008 9:15 AM SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 12-6.) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port.
book.book Page 231 Tuesday, August 5, 2008 9:15 AM Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 232 Tuesday, August 5, 2008 9:15 AM Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port.
book.book Page 233 Tuesday, August 5, 2008 9:15 AM Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port.
book.book Page 234 Tuesday, August 5, 2008 9:15 AM Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
book.book Page 235 Tuesday, August 5, 2008 9:15 AM Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis.
book.book Page 236 Tuesday, August 5, 2008 9:15 AM Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port.
book.book Page 237 Tuesday, August 5, 2008 9:15 AM Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
book.book Page 238 Tuesday, August 5, 2008 9:15 AM Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry.
book.book Page 239 Tuesday, August 5, 2008 9:15 AM USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port.
book.book Page 240 Tuesday, August 5, 2008 9:15 AM USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1.3.6.1.
book.book Page 241 Tuesday, August 5, 2008 9:15 AM Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.
book.book Page 242 Tuesday, August 5, 2008 9:15 AM Table 12-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN.
book.book Page 243 Tuesday, August 5, 2008 9:15 AM Table 12-3. Processor Port Connector Types Variable Name: DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
book.book Page 244 Tuesday, August 5, 2008 9:15 AM Table 12-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM).
book.book Page 245 Tuesday, August 5, 2008 9:15 AM Table 12-4. Memory Device Port Connector Types (continued) Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM). connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM).
book.book Page 246 Tuesday, August 5, 2008 9:15 AM Table 12-6. SCSI Port Connector Types Variable Name: DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin. connectorPortTypeIsDIN50pin(4) The SCSI port connector type is a DIN 50-pin.
book.book Page 247 Tuesday, August 5, 2008 9:15 AM Device Group The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
book.book Page 248 Tuesday, August 5, 2008 9:15 AM Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry. Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex, pointingDeviceIndex Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 249 Tuesday, August 5, 2008 9:15 AM Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device. Syntax DellStateSettings Access Read-write Pointing Device Status Name pointingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.5 Description Defines the status of the pointing device.
book.book Page 250 Tuesday, August 5, 2008 9:15 AM Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device. Syntax DellUnsigned8BitRange Access Read-only Keyboard Device Table Name keyboardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.20 Description Defines the Keyboard Device Table. This table references the Keyboard Port Index (See Section 12).
book.book Page 251 Tuesday, August 5, 2008 9:15 AM Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis. Syntax DellObjectRange Access Read-only Keyboard Device State Capabilities Name keyboardDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.3 Description Defines the capabilities of the keyboard device.
book.book Page 252 Tuesday, August 5, 2008 9:15 AM Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type.
book.book Page 253 Tuesday, August 5, 2008 9:15 AM Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry. Syntax ProcessorDeviceTableEntry Access Not accessible Index processorDevicechassisIndex, processorDeviceIndex Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 254 Tuesday, August 5, 2008 9:15 AM Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device. Syntax DellStateSettings Access Read-write Processor Device Status Name processorDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.5 Description Defines the status of the processor device.
book.book Page 255 Tuesday, August 5, 2008 9:15 AM Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device. Syntax DellString Access Read-only Processor Device Status State Name processorDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.9 Description Defines the status state of the processor device.
book.book Page 256 Tuesday, August 5, 2008 9:15 AM Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 257 Tuesday, August 5, 2008 9:15 AM Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.15 Description Defines the processor upgrade information for the processor device. Syntax DellProcessorUpgradeInformation (See Table 13-5.) Access Read-only Processor Device Version Name Name processorDeviceVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
book.book Page 258 Tuesday, August 5, 2008 9:15 AM Processor Device Thread Count Name processorDeviceThreadCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.19 Description Defines the number of processor threads detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device.
book.book Page 259 Tuesday, August 5, 2008 9:15 AM Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
book.book Page 260 Tuesday, August 5, 2008 9:15 AM Processor Device Brand Name Name processorDeviceBrandName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.23 Description Defines the brand of the processor device. Syntax DellString Access Read-only Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device.
book.book Page 261 Tuesday, August 5, 2008 9:15 AM Processor Device Status Table Entry Name processorDeviceStatusTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1 Description Defines the Processor Device Status Table Entry. Syntax ProcessorDeviceStatusTableEntry Access Not accessible Index processorDeviceStatusChassisIndex, processorDeviceStatusIndex Processor Device Status Chassis Index Name processorDeviceStatusChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.
book.book Page 262 Tuesday, August 5, 2008 9:15 AM Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe. Syntax DellStateCapabilities Access Read-only Processor Device Status State Settings Name processorDeviceStatusStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.
book.book Page 263 Tuesday, August 5, 2008 9:15 AM Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.
book.book Page 264 Tuesday, August 5, 2008 9:15 AM Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis.
book.book Page 265 Tuesday, August 5, 2008 9:15 AM Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device. Syntax DellStatus Access Read-only Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.6 Description Defines the index number of the processor device with which this cache device is associated.
book.book Page 266 Tuesday, August 5, 2008 9:15 AM Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device. Syntax DellCacheDeviceStatusState (See Table 13-10.) Access Read-only Cache Device External Socket Name Name cacheDeviceExternalSocketName Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.10 Description Defines the external socket name of the cache device, if the cache is socketed.
book.book Page 267 Tuesday, August 5, 2008 9:15 AM Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Speed Name cacheDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14 Description Defines the speed of the cache device in nanoseconds.
book.book Page 268 Tuesday, August 5, 2008 9:15 AM Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Table 13-11.) Access Read-only Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device.
book.book Page 269 Tuesday, August 5, 2008 9:15 AM Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table. Syntax SEQUENCE OF MemoryDeviceTableEntry Access Not accessible Memory Device Table Entry Name memoryDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1 Description Defines the Memory Device Table entry.
book.book Page 270 Tuesday, August 5, 2008 9:15 AM Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Memory Device State Settings Name memoryDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.4 Description Defines the state of the memory device.
book.book Page 271 Tuesday, August 5, 2008 9:15 AM Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device. Syntax DellMemoryDeviceType (See Table 13-16.) Access Read-only Memory Device Location Name Name memoryDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.8 Description Defines the location name of the memory device.
book.book Page 272 Tuesday, August 5, 2008 9:15 AM Memory Device Bank Location Name Name memoryDeviceBankLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.10 Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Table 13-17.
book.book Page 273 Tuesday, August 5, 2008 9:15 AM Memory Device Size Name memoryDeviceSize Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.14 Description Defines the size in KB of the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Speed Name memoryDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.15 Description Defines the speed in nanoseconds of the memory device. A zero (0) indicates that the speed is unknown.
book.book Page 274 Tuesday, August 5, 2008 9:15 AM Memory Device Correctable Memory Event Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Correctable Memory Event Count should no longer be used. If you use the Memory Device Correctable Memory Event Count attribute, the value returned is always zero, and using the attribute will have no effect. Name memoryDeviceSingleBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
book.book Page 275 Tuesday, August 5, 2008 9:15 AM Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks.
book.book Page 276 Tuesday, August 5, 2008 9:15 AM Memory Device Asset Tag Name Name memoryDeviceAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.24 Description Defines the asset tag of the memory device. Syntax DellString Access Read-only Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string.
book.book Page 277 Tuesday, August 5, 2008 9:15 AM Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis.
book.book Page 278 Tuesday, August 5, 2008 9:15 AM Memory Device Mapped Address Status Name memoryDeviceMappedAddressStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5 Description Defines the status of the memory device mapped address. Syntax DellStatus Access Read-only Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address.
book.book Page 279 Tuesday, August 5, 2008 9:15 AM Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address.
book.book Page 280 Tuesday, August 5, 2008 9:15 AM Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex, genericDeviceIndex Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 281 Tuesday, August 5, 2008 9:15 AM Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-write Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device.
book.book Page 282 Tuesday, August 5, 2008 9:15 AM Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.
book.book Page 283 Tuesday, August 5, 2008 9:15 AM PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device.
book.book Page 284 Tuesday, August 5, 2008 9:15 AM PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis.
book.book Page 285 Tuesday, August 5, 2008 9:15 AM PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault.
book.book Page 286 Tuesday, August 5, 2008 9:15 AM PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
book.book Page 287 Tuesday, August 5, 2008 9:15 AM PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to.
book.book Page 288 Tuesday, August 5, 2008 9:15 AM PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.
book.book Page 289 Tuesday, August 5, 2008 9:15 AM Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1 Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device.
book.book Page 290 Tuesday, August 5, 2008 9:15 AM Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device. Syntax DellString Access Read-only Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device.
book.book Page 291 Tuesday, August 5, 2008 9:15 AM Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device.
book.book Page 292 Tuesday, August 5, 2008 9:15 AM Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 293 Tuesday, August 5, 2008 9:15 AM Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device.
book.book Page 294 Tuesday, August 5, 2008 9:15 AM Network Device Base IO Port Address Name networkDeviceBaseIOPortAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21 Description Defines the base input/outport port address of the network device. Syntax DellUnsigned32BitRange Access Read-only Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device.
book.book Page 295 Tuesday, August 5, 2008 9:15 AM Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 13-23) Access Read-only Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
book.book Page 296 Tuesday, August 5, 2008 9:15 AM Device Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 13-1. Pointing Device Type Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse.
book.book Page 297 Tuesday, August 5, 2008 9:15 AM Table 13-3. Processor Device Status Reading Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible.
book.book Page 298 Tuesday, August 5, 2008 9:15 AM Table 13-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board.
book.book Page 299 Tuesday, August 5, 2008 9:15 AM Table 13-5. Processor Upgrade Information (continued) Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket939(18) Upgrade is by Socket 939. processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket LGA775. Table 13-6.
book.book Page 300 Tuesday, August 5, 2008 9:15 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsPentium2(13) The processor family is Pentium II. deviceFamilyIsPentiumMMX(14) The processor family is Pentium MMX™. deviceFamilyIsCeleron(15) The processor family is Celeron®. deviceFamilyIsXeon(16) The processor family is Xeon™.
book.book Page 301 Tuesday, August 5, 2008 9:15 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsPowerPC603(34) The processor family is Power PC 603. deviceFamilyIsPowerPC603Plus The processor family is Power PC 603+. (35) deviceFamilyIsPowerPC604(36) The processor family is Power PC 604. deviceFamilyIsPowerPC620(37) The processor family is Power PC 620.
book.book Page 302 Tuesday, August 5, 2008 9:15 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsmicroSPARCIIep The processor family is microSPARC IIep. (83) deviceFamilyIsUltraSPARC(84) The processor family is UltraSPARC. deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II. deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi.
book.book Page 303 Tuesday, August 5, 2008 9:15 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreAMDOpter The processor family is Dual-Core AMD on(135) Opteron. deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon 64 Core(136) X2 Dual-Core. deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64 ile(137) X2 Mobile Technology.
book.book Page 304 Tuesday, August 5, 2008 9:15 AM Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M. deviceFamilyIsIntelCeleronD(186) The processor family is Intel Celeron D. deviceFamilyIsIntelPentiumD(187) The processor family is Intel Pentium D.
book.book Page 305 Tuesday, August 5, 2008 9:15 AM Table 13-8. Cache Device Level Variable Name: DellCacheDeviceLevel Data Type: Integer Possible Data Values Meaning of Data Value deviceLevelIsOther(1) Device level is not one of the following: deviceLevelIsUnknown(2) Device level is unknown. deviceLevelIsPrimary(3) Device level is primary. deviceLevelIsSecondary(4) Device level is secondary. deviceLevelIsTertiary(5) Device level is tertiary. Table 13-9.
book.book Page 306 Tuesday, August 5, 2008 9:15 AM Table 13-10. Cache Device Status State Variable Name: DellCacheDeviceStatusState Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 13-11.
book.book Page 307 Tuesday, August 5, 2008 9:15 AM Table 13-12. Cache Device Associativity Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsOther(1) Device associativity is not one of the following: deviceAssociativityIsUnknown(2) Device associativity is unknown. deviceAssociativityIsDirectMapped(3) Device is direct mapped. deviceAssociativityIsTwoWaySetAsso ciative(4) Device is two-way set associative.
book.book Page 308 Tuesday, August 5, 2008 9:15 AM Table 13-14. Cache Device Static Random-Access Memory (SRAM) Type Variable Name: DellCacheDeviceSRAMType Data Type: Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsOther(1) Device SRAM type is not one of the following: deviceSRAMTypeIsUnknown(2) Device SRAM type is unknown. deviceSRAMTypeIsNonBurst(3) Device SRAM type is nonburst. deviceSRAMTypeIsBurst(4) Device SRAM type is burst.
book.book Page 309 Tuesday, August 5, 2008 9:15 AM Table 13-15. Memory Device Type Form Factor (continued) Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsARowOfChips(11) Device form factor is a row of chips. deviceFormFactorIsRIMM(12) Device form factor is RIMM. deviceFormFactorIsSODIMM(13) Device form factor is SODIMM. deviceFormFactorIsSRIMM(14) Device form factor is SRIMM.
book.book Page 310 Tuesday, August 5, 2008 9:15 AM Table 13-16. Memory Device Type (continued) Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsSDRAM(15) Device type is SDRAM. deviceTypeIsSGRAM(16) Device type is SGRAM. deviceTypeIsRDRAM(17) Device type is RDRAM. deviceTypeIsDDR(18) Device type is DDR. deviceTypeIsDDR2(19) Device type is DDR2. deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM. Table 13-17.
book.book Page 311 Tuesday, August 5, 2008 9:15 AM Table 13-17. Memory Device Type Details (continued) Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsEDO(9) The detailed device type is EDO. deviceTypeDetailIsWindowDRAM(10) The detailed device type is "Window" DRAM. deviceTypeDetailIsCacheDRAM(11) The detailed device type is Cache DRAM. deviceTypeDetailIsNonVolatile(12) The detailed device type is nonvolatile.
book.book Page 312 Tuesday, August 5, 2008 9:15 AM Table 13-19. Memory Device Failure Modes Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value (0) Memory device has no faults. eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate.
book.book Page 313 Tuesday, August 5, 2008 9:15 AM Table 13-20. Network Device Connection Status Variable Name: DellNetworkDeviceConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value unknown(0) Unable to determine connection status. connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled.
book.book Page 314 Tuesday, August 5, 2008 9:15 AM Table 13-22. Network Device TOE Capability Flags Variable Name: DellNetworkDeviceTOECapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for TOE capability is not supported. unknown(1) Querying for TOE capability is supported but query returned an error. available(2) Device has TOE capability.
book.book Page 315 Tuesday, August 5, 2008 9:15 AM Table 13-24. Network Device iSCSI Capability Flags Variable Name: DellNetworkDeviceiSCSICapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for iSCSI capability is not supported. unknown(1) Querying for iSCSI capability is supported but query returned an error. available(2) Device has iSCSI capability.
book.
book.book Page 317 Tuesday, August 5, 2008 9:15 AM Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. System Slot Table The following object sets up the System Slot Table: Name systemSlotTable Object ID 1.
book.book Page 318 Tuesday, August 5, 2008 9:15 AM System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis.
book.book Page 319 Tuesday, August 5, 2008 9:15 AM System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.
book.book Page 320 Tuesday, August 5, 2008 9:15 AM System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 14-5.) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.
book.book Page 321 Tuesday, August 5, 2008 9:15 AM System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
book.book Page 322 Tuesday, August 5, 2008 9:15 AM Table 14-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal The system slot attention state Attention(8) (and corresponding LED) can be set. systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can PowerFault(16) be detected due to a short or overcurrent.
book.book Page 323 Tuesday, August 5, 2008 9:15 AM Table 14-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on.
book.book Page 324 Tuesday, August 5, 2008 9:15 AM Table 14-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video. systemSlotSupportsModemRingResume The system slot supports modem (8192) ring resume.
book.book Page 325 Tuesday, August 5, 2008 9:15 AM Table 14-3. System Slot Type Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsOther(1) The system slot type is not one of following: systemSlotIsUnknown(2) The system slot type is unknown. systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA).
book.book Page 326 Tuesday, August 5, 2008 9:15 AM Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card.
book.book Page 327 Tuesday, August 5, 2008 9:15 AM Table 14-5. System Slot Length Variable Name: DellSystemSlotLength Data Type: Integer Possible Data Values Meaning of Data Value systemSlotLengthIsOther(1) The system slot length is not one of following: systemSlotLengthIsUnknown(2) The system slot length is unknown. systemSlotLengthIsShort(3) The system slot length is short. systemSlotLengthIsLong(4) The system slot length is long. Table 14-6.
book.book Page 328 Tuesday, August 5, 2008 9:15 AM Table 14-7. Hot-Plug Bus Width Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIsOther(1) The system slot bus width is not one of following: busWidthIsUnknown(2) The system slot bus width is unknown. busWidthIs8bits(3) The system slot bus width is 8 bits. busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits.
book.book Page 329 Tuesday, August 5, 2008 9:15 AM Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
book.book Page 330 Tuesday, August 5, 2008 9:15 AM The following object sets up the Physical Memory Array Table: Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry.
book.book Page 331 Tuesday, August 5, 2008 9:15 AM Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array.
book.book Page 332 Tuesday, August 5, 2008 9:15 AM Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Table 15-2.) Access Read-only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 333 Tuesday, August 5, 2008 9:15 AM Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
book.book Page 334 Tuesday, August 5, 2008 9:15 AM Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15 Description Defines the index to the associated Redundant Memory Unit in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses.
book.book Page 335 Tuesday, August 5, 2008 9:15 AM Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
book.book Page 336 Tuesday, August 5, 2008 9:15 AM Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
book.book Page 337 Tuesday, August 5, 2008 9:15 AM Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.
book.book Page 338 Tuesday, August 5, 2008 9:15 AM Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
book.book Page 339 Tuesday, August 5, 2008 9:15 AM Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory.
book.book Page 340 Tuesday, August 5, 2008 9:15 AM Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1 Description Defines the Physical Memory Logging Table entry. Syntax PhysicalMemoryLoggingTableEntry Access Not accessible Index physicalMemoryLoggingChassisIndex, physicalMemoryLoggingIndex Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.
book.book Page 341 Tuesday, August 5, 2008 9:15 AM Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4 Description Defines the settings of the physical memory logging. Syntax DellPhysicalMemoryLoggingSettings Access Read-write Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5 Description Defines the status of the physical memory logging.
book.book Page 342 Tuesday, August 5, 2008 9:15 AM Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
book.book Page 343 Tuesday, August 5, 2008 9:15 AM Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
book.book Page 344 Tuesday, August 5, 2008 9:15 AM Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card. The following objects set up the Physical Memory Card Table: Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table.
book.book Page 345 Tuesday, August 5, 2008 9:15 AM Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
book.book Page 346 Tuesday, August 5, 2008 9:15 AM Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card.
book.book Page 347 Tuesday, August 5, 2008 9:15 AM Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
book.book Page 348 Tuesday, August 5, 2008 9:15 AM Table 15-1. Physical Memory Array Location (continued) Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card.
book.book Page 349 Tuesday, August 5, 2008 9:15 AM Table 15-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
book.book Page 350 Tuesday, August 5, 2008 9:15 AM Table 15-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object "not ready.
book.book Page 351 Tuesday, August 5, 2008 9:15 AM Table 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled.
book.book Page 352 Tuesday, August 5, 2008 9:15 AM Table 15-8. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) 352 Memory Group Logging is disabled (0), or enabled (1).
book.book Page 353 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
book.book Page 354 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 355 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device.
book.book Page 356 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock.
book.book Page 357 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 358 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control.
book.book Page 359 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN. Syntax DellStatus Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN.
book.book Page 360 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence. Syntax DellStatus Access Read-only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25 Description Defines the control name of the boot sequence.
book.book Page 361 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 362 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 16-9.) Access Read-write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 363 Tuesday, August 5, 2008 9:15 AM BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlCapabilities Access Read-only BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
book.book Page 364 Tuesday, August 5, 2008 9:15 AM SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description Defines the SCSI Control Table entry.
book.book Page 365 Tuesday, August 5, 2008 9:15 AM SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller.
book.book Page 366 Tuesday, August 5, 2008 9:15 AM Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry.
book.book Page 367 Tuesday, August 5, 2008 9:15 AM Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port. Syntax DellParallelPortControlCapabilitiesUnique (See Table 16-12.) Access Read-only Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
book.book Page 368 Tuesday, August 5, 2008 9:15 AM Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 16-14.) Access Read-only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
book.book Page 369 Tuesday, August 5, 2008 9:15 AM Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
book.book Page 370 Tuesday, August 5, 2008 9:15 AM Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port.
book.book Page 371 Tuesday, August 5, 2008 9:15 AM USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis.
book.book Page 372 Tuesday, August 5, 2008 9:15 AM USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6 Description Defines the setup BIOS name of the USB.
book.book Page 373 Tuesday, August 5, 2008 9:15 AM IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only IDE Control Index Name ideControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.2 Description Defines the index (one-based) of the IDE controller in this chassis.
book.book Page 374 Tuesday, August 5, 2008 9:15 AM IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Name disketteControlTable Object ID 1.3.6.1.4.1.674.
book.book Page 375 Tuesday, August 5, 2008 9:15 AM Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis.
book.book Page 376 Tuesday, August 5, 2008 9:15 AM Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller. Syntax DellStatus Access Read-only Diskette Control Name Name disketteControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.6 Description Defines the setup BIOS name of the diskette controller.
book.book Page 377 Tuesday, August 5, 2008 9:15 AM Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex, networkInterfaceControlIndex Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
book.book Page 378 Tuesday, August 5, 2008 9:15 AM Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3 Description Defines the capabilities of the NIC. Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 16-19.) Access Read-only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
book.book Page 379 Tuesday, August 5, 2008 9:15 AM BIOS Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 16-1. Speaker Control Capabilities Unique Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control capabilities are unknown. enableCapable(2) Setup BIOS can enable speaker control.
book.book Page 380 Tuesday, August 5, 2008 9:15 AM Table 16-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card.
book.book Page 381 Tuesday, August 5, 2008 9:15 AM Table 16-5. Boot Sequence Control Capabilities Unique Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence capabilities are unknown. bootFromDisketteFirstCapable Setup BIOS can boot from a diskette (2) first. bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard (4) drive first.
book.book Page 382 Tuesday, August 5, 2008 9:15 AM Table 16-7. BIOS Password Control Capabilities Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known(1) unknown. passwordControlEnableCapable (2) Setup BIOS is capable of enabling password changes. passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled.
book.book Page 383 Tuesday, August 5, 2008 9:15 AM Table 16-9. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 16-10.
book.book Page 384 Tuesday, August 5, 2008 9:15 AM Table 16-12. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown. enableCapable(2) Setup BIOS can enable the parallel port. lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.
book.book Page 385 Tuesday, August 5, 2008 9:15 AM Table 16-14. Parallel Port Control Mode Settings Variable Name: DellParallelPortControlModeSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port mode is unknown. atModeEnabled(2) Setup BIOS has set the parallel port to AT mode. ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode.
book.book Page 386 Tuesday, August 5, 2008 9:15 AM Table 16-15. Serial Port Control Capabilities (continued) Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(86) COM1 and COM3 serial ports. com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(106) COM2 and COM4 serial ports.
book.book Page 387 Tuesday, August 5, 2008 9:15 AM Table 16-17. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable(2) enable capable. Table 16-18.
book.book Page 388 Tuesday, August 5, 2008 9:15 AM Table 16-20. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE.
book.book Page 389 Tuesday, August 5, 2008 9:15 AM Local Response Agent Group The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator will respond to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis.
book.book Page 390 Tuesday, August 5, 2008 9:15 AM LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry.
book.book Page 391 Tuesday, August 5, 2008 9:15 AM LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings will be disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.
book.book Page 392 Tuesday, August 5, 2008 9:15 AM LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table.
book.book Page 393 Tuesday, August 5, 2008 9:15 AM LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
book.book Page 394 Tuesday, August 5, 2008 9:15 AM LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the "execute application value" is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256)) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.
book.book Page 395 Tuesday, August 5, 2008 9:15 AM Table 17-1. LRA Capabilities Definitions (continued) Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application.
book.book Page 396 Tuesday, August 5, 2008 9:15 AM Table 17-2. LRA Thermal Shutdown Capabilities Unique (continued) Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected. The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected.
book.book Page 397 Tuesday, August 5, 2008 9:15 AM Cost of Ownership Group The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
book.book Page 398 Tuesday, August 5, 2008 9:15 AM Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.6.
book.book Page 399 Tuesday, August 5, 2008 9:15 AM COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system.
book.book Page 400 Tuesday, August 5, 2008 9:15 AM COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 401 Tuesday, August 5, 2008 9:15 AM COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system.
book.book Page 402 Tuesday, August 5, 2008 9:15 AM COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system. Syntax DellCooOwnershipCodes (See Table 18-1.
book.book Page 403 Tuesday, August 5, 2008 9:15 AM COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See Table 18-2.
book.book Page 404 Tuesday, August 5, 2008 9:15 AM COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 405 Tuesday, August 5, 2008 9:15 AM COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag.
book.book Page 406 Tuesday, August 5, 2008 9:15 AM COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
book.book Page 407 Tuesday, August 5, 2008 9:15 AM COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
book.book Page 408 Tuesday, August 5, 2008 9:15 AM COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.
book.book Page 409 Tuesday, August 5, 2008 9:15 AM COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed.
book.book Page 410 Tuesday, August 5, 2008 9:15 AM COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.674.
book.book Page 411 Tuesday, August 5, 2008 9:15 AM COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
book.book Page 412 Tuesday, August 5, 2008 9:15 AM COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.
book.book Page 413 Tuesday, August 5, 2008 9:15 AM COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty.
book.book Page 414 Tuesday, August 5, 2008 9:15 AM COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
book.book Page 415 Tuesday, August 5, 2008 9:15 AM COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system.
book.book Page 416 Tuesday, August 5, 2008 9:15 AM COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
book.book Page 417 Tuesday, August 5, 2008 9:15 AM COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry.
book.book Page 418 Tuesday, August 5, 2008 9:15 AM COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
book.book Page 419 Tuesday, August 5, 2008 9:15 AM COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex, cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 420 Tuesday, August 5, 2008 9:15 AM COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name.
book.book Page 421 Tuesday, August 5, 2008 9:15 AM COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information.
book.book Page 422 Tuesday, August 5, 2008 9:15 AM COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name.
book.book Page 423 Tuesday, August 5, 2008 9:15 AM COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis.
book.book Page 424 Tuesday, August 5, 2008 9:15 AM COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system.
book.book Page 425 Tuesday, August 5, 2008 9:15 AM COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information.
book.book Page 426 Tuesday, August 5, 2008 9:15 AM COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
book.book Page 427 Tuesday, August 5, 2008 9:15 AM COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry. Syntax cooTroubleTicketTableEntry Access Not accessible Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 428 Tuesday, August 5, 2008 9:15 AM COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
book.book Page 429 Tuesday, August 5, 2008 9:15 AM Table 18-2. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 18-3.
book.
book.book Page 431 Tuesday, August 5, 2008 9:15 AM Remote Access Group The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
book.book Page 432 Tuesday, August 5, 2008 9:15 AM Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
book.book Page 433 Tuesday, August 5, 2008 9:15 AM Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware.
book.book Page 434 Tuesday, August 5, 2008 9:15 AM Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 435 Tuesday, August 5, 2008 9:15 AM Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 436 Tuesday, August 5, 2008 9:15 AM Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 437 Tuesday, August 5, 2008 9:15 AM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.
book.book Page 438 Tuesday, August 5, 2008 9:15 AM Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry.
book.book Page 439 Tuesday, August 5, 2008 9:15 AM Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 19-1.) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware.
book.book Page 440 Tuesday, August 5, 2008 9:15 AM Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 441 Tuesday, August 5, 2008 9:15 AM Remote Access Control Settings Name remoteAccessControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11 Description Defines the control settings of the remote access hardware. Syntax DellRemoteAccessControlSettings (See Table 19-3.) Access Read-write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 442 Tuesday, August 5, 2008 9:15 AM Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 19-7.) Access Read-write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16 Description Defines the host capabilities of the remote access hardware.
book.book Page 443 Tuesday, August 5, 2008 9:15 AM Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 19-11.) Access Read-write Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address Name remoteAccessSMTPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.
book.book Page 444 Tuesday, August 5, 2008 9:15 AM Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 445 Tuesday, August 5, 2008 9:15 AM Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware.
book.book Page 446 Tuesday, August 5, 2008 9:15 AM Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
book.book Page 447 Tuesday, August 5, 2008 9:15 AM Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.
book.book Page 448 Tuesday, August 5, 2008 9:15 AM Remote User Admin Chassis Index Name remoteUserAdminChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 449 Tuesday, August 5, 2008 9:15 AM Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5 Description Defines the state settings for this remote access user. Syntax DellRemoteUserAdminStateSettings (See Table 19-13.) Access Read-write Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user.
book.book Page 450 Tuesday, August 5, 2008 9:15 AM Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10 Description Defines the privilege capabilities for this remote access user.
book.book Page 451 Tuesday, August 5, 2008 9:15 AM Remote User Admin Alert Filter DRS Capabilities Name remoteUserAdminAlertFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13 Description Defines the DRS events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 452 Tuesday, August 5, 2008 9:15 AM Remote User Admin Pager Numeric Hang-up Delay Name remoteUserAdminPagerNumericHangupDelay Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17 Description Defines the numeric pager hang-up delay for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 453 Tuesday, August 5, 2008 9:15 AM Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.1.
book.book Page 454 Tuesday, August 5, 2008 9:15 AM Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 455 Tuesday, August 5, 2008 9:15 AM Remote User Admin Control Capabilities Name remoteUserAdminControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29 Description Defines the control capabilities for this remote access user. Syntax DellRemoteUserAdminControlCapabilities (See Table 19-14.) Access Read-only Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
book.book Page 456 Tuesday, August 5, 2008 9:15 AM Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1 Description Defines the Remote Access SNMP Trap Destination Table entry. Syntax RemoteSNMPTrapTableEntry Access Not accessible Index remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 457 Tuesday, August 5, 2008 9:15 AM Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3 Description Defines the index (one-based) of this remote access SNMP trap destination. Syntax DellObjectRange Access Read-only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4 Description Defines the state capabilities of this remote access SNMP trap destination.
book.book Page 458 Tuesday, August 5, 2008 9:15 AM Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 459 Tuesday, August 5, 2008 9:15 AM Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
book.book Page 460 Tuesday, August 5, 2008 9:15 AM Remote Dial-Up Table Name remoteDialUpTable Object ID 1.3.6.1.4.1.674.10892.1.1700.40 Description Defines the Remote Access Dial-Up Table. Syntax SEQUENCE OF RemoteDialUpTableEntry Access Not accessible Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry.
book.book Page 461 Tuesday, August 5, 2008 9:15 AM Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up Index Name remoteDialUpIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 462 Tuesday, August 5, 2008 9:15 AM Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality. Syntax DellStatus Access Read-only Remote Dial-Up PPP Dial-In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7 Description Defines the base IP address of the PPP server for this remote access dial-up functionality.
book.book Page 463 Tuesday, August 5, 2008 9:15 AM Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
book.book Page 464 Tuesday, August 5, 2008 9:15 AM Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table.
book.book Page 465 Tuesday, August 5, 2008 9:15 AM Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 466 Tuesday, August 5, 2008 9:15 AM Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 19-26.) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
book.book Page 467 Tuesday, August 5, 2008 9:15 AM Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table.
book.book Page 468 Tuesday, August 5, 2008 9:15 AM Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.
book.book Page 469 Tuesday, August 5, 2008 9:15 AM Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination.
book.book Page 470 Tuesday, August 5, 2008 9:15 AM Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 19-1.
book.book Page 471 Tuesday, August 5, 2008 9:15 AM Table 19-2. Remote Access Control Capabilities (continued) Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value logResetCapable(2) The remote access hardware can reset its integrated logs. hardResetCapable(4) The remote access hardware can perform a hard reset. softResetCapable(8) The remote access hardware can perform a soft reset.
book.book Page 472 Tuesday, August 5, 2008 9:15 AM Table 19-3. Remote Access Control Settings (continued) Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value gracefulReset(16) The remote access hardware will gracefully shut down and perform a soft reset. defaultConfigReset(32) The remote access hardware will reset to its default settings. shutdown(64) The remote access hardware will shut down. Table 19-4.
book.book Page 473 Tuesday, August 5, 2008 9:15 AM Table 19-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConn The remote access hardware will monitor the ectedEnabled(2) external power supply, if connected.
book.book Page 474 Tuesday, August 5, 2008 9:15 AM Table 19-7. Remote Access LAN Settings Variable Name: DellRemoteAccessLANSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4) The remote access hardware NIC will use DHCP to obtain an IP address. Table 19-8.
book.book Page 475 Tuesday, August 5, 2008 9:15 AM Table 19-9. Remote Access Host Settings Variable Name: DellRemoteAccessHostSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host settings. unknown(1) The remote access hardware host settings are unknown. smtpEmailEnabled(2) The remote access hardware SMTP client is enabled for sending e-mail.
book.book Page 476 Tuesday, August 5, 2008 9:15 AM Table 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings Variable Name: DellRemoteAccessOutOfBandSNMPSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP settings. unknown(1) The remote access hardware out-of-band SNMP settings are unknown. oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP agent is enabled.
book.book Page 477 Tuesday, August 5, 2008 9:15 AM Table 19-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the "not ready" state. numericPagerEnabled(8) Numeric paging is enabled for the admin user.
book.book Page 478 Tuesday, August 5, 2008 9:15 AM Table 19-15. Remote User Admin Control Settings Variable Name: DellRemoteUserAdminControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control settings. unknown(1) The admin user control settings are unknown. numericPagerTest(2) A numeric pager test will be performed for the admin user. alphaPagerTest(4) An alphanumeric pager test will be performed for the admin user.
book.book Page 479 Tuesday, August 5, 2008 9:15 AM Table 19-17. Remote User Admin Alpha Baud Type Variable Name: DellRemoteUserAdminAlphaBaudType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user alphanumeric baud rate is not one of the following: unknown(2) The remote user alphanumeric baud rate is unknown. alphaBaud300(3) The remote user alphanumeric baud rate is 300. alphaBaud1200(4) The remote user alphanumeric baud rate is 1200. Table 19-18.
book.book Page 480 Tuesday, August 5, 2008 9:15 AM Table 19-20. Remote SNMP Trap Control Capabilities Variable Name: DellRemoteSNMPTrapControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilities The SNMP trap destination control capabilities are (1) unknown. trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap destination. Table 19-21.
book.book Page 481 Tuesday, August 5, 2008 9:15 AM Table 19-22. Remote Dial-Up State Capabilities (continued) Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value notReadyCapable(4) The dial-up functionality can be in the "not ready" state. dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(16) The dial-up functionality can support the dial-out feature.
book.book Page 482 Tuesday, August 5, 2008 9:15 AM Table 19-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled The dial-up functionality accepts any authentication (64) type (including clear text) for the dial-in feature.
book.book Page 483 Tuesday, August 5, 2008 9:15 AM Table 19-25. Remote User Dial-In State Capabilities Variable Name: DellRemoteUserDialInStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilities(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled. notReadyCapable(4) The dial-in user can be in the "not ready" state.
book.book Page 484 Tuesday, August 5, 2008 9:15 AM Table 19-27. Remote Dial-Out State Capabilities Variable Name: DellRemoteDialOutStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilities(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable(4) The dial-out destination can be in the "not ready" state.
book.book Page 485 Tuesday, August 5, 2008 9:15 AM Table 19-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the "not ready" state.
book.
book.book Page 487 Tuesday, August 5, 2008 9:15 AM Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using "failover" clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
book.book Page 488 Tuesday, August 5, 2008 9:15 AM Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Cluster State Capabilities Name clusterStateCapabilities Object ID 1.
book.book Page 489 Tuesday, August 5, 2008 9:15 AM Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
book.book Page 490 Tuesday, August 5, 2008 9:15 AM Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 20-1. Cluster Type Variable Name: DellClusterType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster.
book.book Page 491 Tuesday, August 5, 2008 9:15 AM Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
book.book Page 492 Tuesday, August 5, 2008 9:15 AM BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis.
book.book Page 493 Tuesday, August 5, 2008 9:15 AM BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
book.book Page 494 Tuesday, August 5, 2008 9:15 AM BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC.
book.book Page 495 Tuesday, August 5, 2008 9:15 AM Baseboard Management Controller Serial Interface Table Name bmcSerialInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table. Syntax SEQUENCE OF BmcSerialInterfaceTableEntry Access Not accessible BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry.
book.book Page 496 Tuesday, August 5, 2008 9:15 AM BMC Serial Interface Index Name bmcSerialInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.3 Description Defines the index (one-based) of the BMC serial interface. Syntax DellObjectRange Access Read-only BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface.
book.book Page 497 Tuesday, August 5, 2008 9:15 AM BMC Serial Interface Channel Number Name bmcSerialInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7 Description Defines the BMC channel number of the BMC serial interface. Syntax DellUnsigned8BitRange Access Read-only BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
book.book Page 498 Tuesday, August 5, 2008 9:15 AM BMC Serial Interface Bit Rate Name bmcSerialInterfaceBitRate Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.11 Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table.
book.book Page 499 Tuesday, August 5, 2008 9:15 AM BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC.
book.book Page 500 Tuesday, August 5, 2008 9:15 AM BMC LAN Interface State Settings Name bmcLANInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.5 Description Defines the state settings of the BMC LAN interface. Syntax DellStateSettings Access Read-write BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface.
book.book Page 501 Tuesday, August 5, 2008 9:15 AM BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface.
book.book Page 502 Tuesday, August 5, 2008 9:15 AM BMC LAN Interface Alert Community Name Name bmcLANInterfaceAlertCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.13 Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section.
book.book Page 503 Tuesday, August 5, 2008 9:15 AM Table 21-2. BMC Serial Connection Mode Settings Variable Name: DellBMCSerialConnectionModeSettings Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No modes enabled. modemBasic(1) Modem Basic mode is enabled. modemPPP(2) Modem PPP mode is enabled. modemTerminal(4) Modem Terminal mode is enabled. directBasic(8) Direct Basic mode is enabled.
book.book Page 504 Tuesday, August 5, 2008 9:15 AM Table 21-4. BMC Serial Bit Rate Type Variable Name: DellBMCSerialBitRateType Data Type: Integer Possible Data Values Meaning of Data Value bps9600(6) Bit rate is 9600 bps (bits per second) bps19200(7) Bit rate is 19200 bps bps38400(8) Bit rate is 38400 bps bps57600(9) Bit rate is 57600 bps bps115200(10) Bit rate is 115200 bps Table 21-5.
book.book Page 505 Tuesday, August 5, 2008 9:15 AM Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units.
book.book Page 506 Tuesday, August 5, 2008 9:15 AM FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.
book.book Page 507 Tuesday, August 5, 2008 9:15 AM FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Serial Number Name Name fruSerialNumberName Object ID 1.
book.book Page 508 Tuesday, August 5, 2008 9:15 AM FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.
book.book Page 509 Tuesday, August 5, 2008 9:15 AM FRU Group Variable Values This section includes definitions for server administrator-specific variable values. Table 22-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid.
book.
book.book Page 511 Tuesday, August 5, 2008 9:15 AM Storage Management Group The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software.
book.book Page 512 Tuesday, August 5, 2008 9:15 AM Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group.
book.book Page 513 Tuesday, August 5, 2008 9:15 AM Software Description Name softwareDescription Object ID 1.3.6.1.4.1.674.10893.1.20.5 Description Identifies the product description for the Storage Management software. Syntax DisplayString Access Read-only Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.
book.book Page 514 Tuesday, August 5, 2008 9:15 AM Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
book.book Page 515 Tuesday, August 5, 2008 9:15 AM Agent Last Global Status Name agentLastGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.2 Description This entry is obsolete. Use the value agentLastGlobalSystemStatus. Syntax Integer Access Read-only Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in sec since UTC 1/1/70.
book.book Page 516 Tuesday, August 5, 2008 9:15 AM Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 517 Tuesday, August 5, 2008 9:15 AM Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.
book.book Page 518 Tuesday, August 5, 2008 9:15 AM Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 519 Tuesday, August 5, 2008 9:15 AM Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.
book.book Page 520 Tuesday, August 5, 2008 9:15 AM Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. 520 • Controller Table—describes available properties for each controller on the managed system. • Channel Table—describes available properties for each channel on the managed system.
book.book Page 521 Tuesday, August 5, 2008 9:15 AM • Temperature Probe Table—describes available properties for each temperature probe on the managed system. • Temperature Probe Connection Table—describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the Enclosure Table. • EMM Table—describes available properties for each Enclosure Management Module (EMM) on the managed system.
book.book Page 522 Tuesday, August 5, 2008 9:15 AM Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 523 Tuesday, August 5, 2008 9:15 AM Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 524 Tuesday, August 5, 2008 9:15 AM Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 525 Tuesday, August 5, 2008 9:15 AM Controller Firmware Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.8 Description Identifies the controller's current firmware version. Syntax DisplayString Access Read-only Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 Description Identifies the controller's current amount of cache memory in megabytes.
book.book Page 526 Tuesday, August 5, 2008 9:15 AM Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller. Syntax Integer Access Read-only Controller Partner Status Name controllerPartnerStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.13 Description This entry is obsolete for Storage Management.
book.book Page 527 Tuesday, August 5, 2008 9:15 AM Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB will be the total size of the memory. This attribute is only supported on Adaptec controllers.
book.book Page 528 Tuesday, August 5, 2008 9:15 AM Controller C0 Port 0 World Wide Name Name controllerC0Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.19 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 529 Tuesday, August 5, 2008 9:15 AM Controller C0 Channel Name controllerC0Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Operating System Controller Name controllerC0OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 530 Tuesday, August 5, 2008 9:15 AM Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 531 Tuesday, August 5, 2008 9:15 AM Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 532 Tuesday, August 5, 2008 9:15 AM Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
book.book Page 533 Tuesday, August 5, 2008 9:15 AM Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 Description Indicates the status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 534 Tuesday, August 5, 2008 9:15 AM Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.41 Description Indicates currently installed driver version of the controller Syntax DisplayString Access Read-only Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
book.book Page 535 Tuesday, August 5, 2008 9:15 AM Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.45 Description The minimum driver version for Storage Management to support the controller.
book.book Page 536 Tuesday, August 5, 2008 9:15 AM Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description The rate for patrol read on the controller.
book.book Page 537 Tuesday, August 5, 2008 9:15 AM Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual (enabled) 3: Disabled Syntax Integer Access Read-only Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read.
book.book Page 538 Tuesday, August 5, 2008 9:15 AM Channel Table This table describes available properties for each channel on the managed system. The following object sets up the Channel Table. Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry.
book.book Page 539 Tuesday, August 5, 2008 9:15 AM Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Description Identifies the name of the channel as represented in Storage Management. The name will include the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of this channel.
book.book Page 540 Tuesday, August 5, 2008 9:15 AM Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 541 Tuesday, August 5, 2008 9:15 AM Channel Roll-Up Status Name channelRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 Description Identifies the severity of the channel state. This is the combined status of the channel and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 542 Tuesday, August 5, 2008 9:15 AM Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel. Syntax DisplayString Access Read-only Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 Description Identifies the data rate of this channel. Syntax DisplayString Access Read-only Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
book.book Page 543 Tuesday, August 5, 2008 9:15 AM Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry.
book.book Page 544 Tuesday, August 5, 2008 9:15 AM Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Enclosure State Name enclosureState Object ID 1.3.6.1.
book.book Page 545 Tuesday, August 5, 2008 9:15 AM Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Identifies the SCSI address of the processor.
book.book Page 546 Tuesday, August 5, 2008 9:15 AM Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure.
book.book Page 547 Tuesday, August 5, 2008 9:15 AM Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management.
book.book Page 548 Tuesday, August 5, 2008 9:15 AM Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure.
book.book Page 549 Tuesday, August 5, 2008 9:15 AM Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 550 Tuesday, August 5, 2008 9:15 AM Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 Description Identifies the SCSI ID of the controller to which this enclosure is attached.
book.book Page 551 Tuesday, August 5, 2008 9:15 AM Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
book.book Page 552 Tuesday, August 5, 2008 9:15 AM Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.
book.book Page 553 Tuesday, August 5, 2008 9:15 AM Array Disk Table This table describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.
book.book Page 554 Tuesday, August 5, 2008 9:15 AM Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name.
book.book Page 555 Tuesday, August 5, 2008 9:15 AM Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller.
book.book Page 556 Tuesday, August 5, 2008 9:15 AM Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk.
book.book Page 557 Tuesday, August 5, 2008 9:15 AM Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
book.book Page 558 Tuesday, August 5, 2008 9:15 AM Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.
book.book Page 559 Tuesday, August 5, 2008 9:15 AM Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 560 Tuesday, August 5, 2008 9:15 AM Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 561 Tuesday, August 5, 2008 9:15 AM Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.
book.book Page 562 Tuesday, August 5, 2008 9:15 AM Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description The status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
book.book Page 563 Tuesday, August 5, 2008 9:15 AM Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.28 Description Indicates the specified SAS address if this is a SAS disk.
book.book Page 564 Tuesday, August 5, 2008 9:15 AM Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert Syntax Integer Access Read-only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 565 Tuesday, August 5, 2008 9:15 AM Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description The four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Table This table describes the connections among array disks, their enclosure, and their associated controller.
book.book Page 566 Tuesday, August 5, 2008 9:15 AM Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1 Description Identifies the instance number of the array disk enclosure connection entry. Syntax Integer Access Read-only Array Disk Enclosure Connection Array Disk Name Name arrayDiskEnclosureConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
book.book Page 567 Tuesday, August 5, 2008 9:15 AM Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs. Syntax Integer Access Read-only Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
book.book Page 568 Tuesday, August 5, 2008 9:15 AM The following object sets up the Array Disk Channel Connection Table. Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.
book.book Page 569 Tuesday, August 5, 2008 9:15 AM Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer Access Read-only Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
book.book Page 570 Tuesday, August 5, 2008 9:15 AM Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected. Syntax Integer Access Read-only Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table.
book.book Page 571 Tuesday, August 5, 2008 9:15 AM Fan Number Name fanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.1 Description Identifies the instance number of the fan entry. Syntax Integer Access Read-only Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
book.book Page 572 Tuesday, August 5, 2008 9:15 AM Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management.
book.book Page 573 Tuesday, August 5, 2008 9:15 AM Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete.
book.book Page 574 Tuesday, August 5, 2008 9:15 AM Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.
book.book Page 575 Tuesday, August 5, 2008 9:15 AM Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
book.book Page 576 Tuesday, August 5, 2008 9:15 AM Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
book.book Page 577 Tuesday, August 5, 2008 9:15 AM Fan Connection Entry Name fanConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1 Description Defines the fan connection table entry. Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry.
book.book Page 578 Tuesday, August 5, 2008 9:15 AM Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs. Syntax DisplayString Access Read-only Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.
book.book Page 579 Tuesday, August 5, 2008 9:15 AM Power Supply Entry Name powerSupplyEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1 Description Defines the power supply table entry. Syntax PowerSupplyEntry Access Not accessible Index powerSupplyNumber Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry.
book.book Page 580 Tuesday, August 5, 2008 9:15 AM Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 Description Identifies the current state of the power supply. Possible states: 0: Unknown 1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 Description This entry is obsolete for Storage Management.
book.book Page 581 Tuesday, August 5, 2008 9:15 AM Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete. This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read-only Power Supply Roll-Up Status Name powerSupplyRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.8 Description Severity of the power supply state.
book.book Page 582 Tuesday, August 5, 2008 9:15 AM Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
book.book Page 583 Tuesday, August 5, 2008 9:15 AM Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table.
book.book Page 584 Tuesday, August 5, 2008 9:15 AM Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
book.book Page 585 Tuesday, August 5, 2008 9:15 AM Temperature Probe Table This table describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.11 Description A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent.
book.book Page 586 Tuesday, August 5, 2008 9:15 AM Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 Description Identifies the temperature probe's name as represented in Storage Management. Syntax DisplayString Access Read-only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name.
book.book Page 587 Tuesday, August 5, 2008 9:15 AM Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Temperature Probe Unit Name temperatureProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
book.book Page 588 Tuesday, August 5, 2008 9:15 AM Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that will force the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
book.book Page 589 Tuesday, August 5, 2008 9:15 AM Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 Description Severity of the temperature probe state. This is the combined status of the temperature probe and its components.
book.book Page 590 Tuesday, August 5, 2008 9:15 AM Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.14 Description Durable unique ID for this temperature probe. Syntax DisplayString Access Read-only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table.
book.book Page 591 Tuesday, August 5, 2008 9:15 AM Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry. Syntax Integer Access Read-only Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
book.book Page 592 Tuesday, August 5, 2008 9:15 AM Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system.
book.book Page 593 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
book.book Page 594 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.
book.book Page 595 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
book.book Page 596 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state. This is the combined status of the EMM and its components.
book.book Page 597 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module.
book.book Page 598 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.
book.book Page 599 Tuesday, August 5, 2008 9:15 AM Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection. Syntax Integer Access Read-only Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1.3.6.1.4.1.674.
book.book Page 600 Tuesday, August 5, 2008 9:15 AM Battery Table This table describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry.
book.book Page 601 Tuesday, August 5, 2008 9:15 AM Battery Name Name batteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 Description Identifies the battery's name as represented in Storage Management. Syntax DisplayString Access Read-only Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.
book.book Page 602 Tuesday, August 5, 2008 9:15 AM Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 603 Tuesday, August 5, 2008 9:15 AM Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 Description The number of charges that have been applied to the battery. Syntax Integer Access Read-only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 Description The maximum number of charges that can be applied to the battery.
book.book Page 604 Tuesday, August 5, 2008 9:15 AM Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
book.book Page 605 Tuesday, August 5, 2008 9:15 AM Battery Learn State Name batteryLearnState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 Description Specifies the learn state activity of the battery. Possible values: 1: Failed 2: Active 4: Timed out 8: Requested 16: Idle Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
book.book Page 606 Tuesday, August 5, 2008 9:15 AM Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller. Each controller "number" in the table corresponds to that controller instance in the controller Table. The following object sets up the Battery Connection Table. Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table.
book.book Page 607 Tuesday, August 5, 2008 9:15 AM Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
book.book Page 608 Tuesday, August 5, 2008 9:15 AM Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other. This group and all of its associated tables and objects are not supported on Microsoft® Windows® Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge™ 7150.
book.book Page 609 Tuesday, August 5, 2008 9:15 AM Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 Description Identifies the instance number of the virtual disk entry.
book.book Page 610 Tuesday, August 5, 2008 9:15 AM Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible.
book.book Page 611 Tuesday, August 5, 2008 9:15 AM Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes.
book.book Page 612 Tuesday, August 5, 2008 9:15 AM Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete.
book.book Page 613 Tuesday, August 5, 2008 9:15 AM Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 Description Indicates whether the controller's read cache will be used when reading from a virtual disk.
book.book Page 614 Tuesday, August 5, 2008 9:15 AM Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 Syntax Integer Access Read-only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 615 Tuesday, August 5, 2008 9:15 AM Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. Syntax Integer Access Read-only Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
book.book Page 616 Tuesday, August 5, 2008 9:15 AM Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.
book.book Page 617 Tuesday, August 5, 2008 9:15 AM Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk.
book.book Page 618 Tuesday, August 5, 2008 9:15 AM Name arrayDiskLogicalConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.3 Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry.
book.book Page 619 Tuesday, August 5, 2008 9:15 AM Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 Description Identifies the instance number of the array disk in this logical connection. Syntax Integer Access Read-only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
book.book Page 620 Tuesday, August 5, 2008 9:15 AM Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that will be sent with SNMP traps.
book.book Page 621 Tuesday, August 5, 2008 9:15 AM Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.4 Description Name of the object as represented in Storage Management causing the alert.
book.book Page 622 Tuesday, August 5, 2008 9:15 AM Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable.
book.book Page 623 Tuesday, August 5, 2008 9:15 AM Change Management Group The Change Management Group lets you monitor information about the Dell™ devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
book.book Page 624 Tuesday, August 5, 2008 9:15 AM Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table.
book.book Page 625 Tuesday, August 5, 2008 9:15 AM Device Component ID Name deviceComponentID Object ID 1.3.6.1.4.1.674.10899.1.5.1.2 Description Defines an optional component ID field for the device. Syntax Integer Access Read-only Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.
book.book Page 626 Tuesday, August 5, 2008 9:15 AM Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification.
book.book Page 627 Tuesday, August 5, 2008 9:15 AM Application Group Table The following object sets up the Application Group Table. Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry.
book.book Page 628 Tuesday, August 5, 2008 9:15 AM Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application.
book.book Page 629 Tuesday, August 5, 2008 9:15 AM Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Vendor Name operatingSystemVendor Object ID 1.3.6.1.4.1.674.10899.2.1 Description Defines the vendor of the Operating System.
book.book Page 630 Tuesday, August 5, 2008 9:15 AM Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version. Syntax DisplayString Access Read-only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.6 Description Defines the Operating System's Service Pack minor version.
book.book Page 631 Tuesday, August 5, 2008 9:15 AM Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product. Syntax DisplayString Access Read-only Product ID Description Name productIDDescription Object ID 1.3.6.1.4.1.674.10899.100.2 Description Provides a description of the product. Syntax DisplayString Access Read-only Product ID Vendor Name productIDVendor Object ID 1.3.6.1.4.1.674.10899.100.
book.book Page 632 Tuesday, August 5, 2008 9:15 AM Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product.
book.book Page 633 Tuesday, August 5, 2008 9:15 AM Dell RAC Out-of-Band Group The Dell RAC Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and Remote Access Controller (RAC) Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 634 Tuesday, August 5, 2008 9:15 AM DRsProductDescription Name DRsProductDescription Object ID 1.3.6.1.4.1.674.10892.2.1.1.3 Description Defines the product description of a chassis management controller. Syntax DellString Access Read-only DRsProductManufacturer Name DRsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller.
book.book Page 635 Tuesday, August 5, 2008 9:15 AM DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.7 Description Defines the out-of-band UI URL of a chassis management controller. Syntax DellString Access Read-only DRsProductChassisAssetTag Name DRsProductChassisAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.8 Description Defines the Asset Tag of the chassis.
book.book Page 636 Tuesday, August 5, 2008 9:15 AM DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
book.book Page 637 Tuesday, August 5, 2008 9:15 AM DRsFirmwareVersion Name DRsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.
book.book Page 638 Tuesday, August 5, 2008 9:15 AM DRsIOMCurrStatus Name DRsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card.
book.book Page 639 Tuesday, August 5, 2008 9:15 AM DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsBladeCurrStatus Name DRsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card.
book.book Page 640 Tuesday, August 5, 2008 9:15 AM DRsGlobalPrevStatus Name DRsGlobalPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.1 Description Defines the previous chassis status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card.
book.book Page 641 Tuesday, August 5, 2008 9:15 AM DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card.
book.book Page 642 Tuesday, August 5, 2008 9:15 AM DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsGlobalChangeTime Name DRsGlobalChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.1 Description Defines the timestamp of the most recent global status change.
book.book Page 643 Tuesday, August 5, 2008 9:15 AM DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only DRsPowerChangeTime Name DrsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.5 Description Defines the timestamp of the most recent power health status change.
book.book Page 644 Tuesday, August 5, 2008 9:15 AM DRsTempChangeTime Name DRsTempChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.8 Description Defines the timestamp of the most recent temperature sensor health status change. Syntax TimeTicks Access Read-only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change.
book.book Page 645 Tuesday, August 5, 2008 9:15 AM DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry. Syntax DrsCMCPowerTableEntry Access Not-accessible DRsCMC PSUTable Name DrsCMCPSUTable Object ID 1.3.6.1.4.1.674.10892.2.4.2 Description Defines the CMC PSU table. Syntax SEQUENCE OF DrsCMCPSUTableEntry Access Not-accessible DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.
book.book Page 646 Tuesday, August 5, 2008 9:15 AM DRsPotentialPower Name DRsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2 Description Defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only DRsIdlePower Name DRsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
book.book Page 647 Tuesday, August 5, 2008 9:15 AM DRsPowerSurplus Name DRsPowerSurplus Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5 Description Defines the power surplus (in Watts) remaining above the drsPotentialPower reading. Syntax DellPowerReading Access Read-only DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset.
book.book Page 648 Tuesday, August 5, 2008 9:15 AM DRsWattsPeakTime Name DRsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9 Description Defines the timestamp of the most recent chassis peak power usage. Syntax DellTimestamp Access Read-only DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10 Description Defines the chassis minimum power usage (in Watts) since last reset.
book.book Page 649 Tuesday, August 5, 2008 9:15 AM DRsWattsReading Name DRsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in Watts) Syntax DellPowerReading Access Read-only DRsAmpsReading Name DRsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in Watts).
book.book Page 650 Tuesday, August 5, 2008 9:15 AM DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.
book.book Page 651 Tuesday, August 5, 2008 9:15 AM DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU Current reading. Syntax DellPowerReading Access Read-only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading.
book.book Page 652 Tuesday, August 5, 2008 9:15 AM DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the Current Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.3 Description Defines the Previous Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1.3.6.1.4.1.
book.book Page 653 Tuesday, August 5, 2008 9:15 AM Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax OCTET STRING (SIZE (0..255)) Access Read-only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier.
book.book Page 654 Tuesday, August 5, 2008 9:15 AM DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.2.
book.book Page 655 Tuesday, August 5, 2008 9:15 AM Traps The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management Controller (BMC) also can generate SNMP traps in response to hardware events. This section describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC.
book.book Page 656 Tuesday, August 5, 2008 9:15 AM Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system. The trap variables presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed and are reserved for use only in traps.
book.book Page 657 Tuesday, August 5, 2008 9:15 AM Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.4 Description Gives the current status of the object causing the alert. Syntax DellStatus Previous Status Variable Name alertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5 Description Gives the previous status of the object causing the alert. Syntax DellStatus Data Variable Name alertData Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
book.book Page 658 Tuesday, August 5, 2008 9:15 AM Understanding the Trap Description Table 26-1 lists in alphabetical order each line item that may appear in the trap description. Table 26-1.
book.book Page 659 Tuesday, August 5, 2008 9:15 AM Table 26-1.
book.book Page 660 Tuesday, August 5, 2008 9:15 AM Table 26-1.
book.book Page 661 Tuesday, August 5, 2008 9:15 AM Table 26-1.
book.book Page 662 Tuesday, August 5, 2008 9:15 AM Understanding Trap Severity Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values such as amperage, voltage, and temperature.
book.book Page 663 Tuesday, August 5, 2008 9:15 AM Table 26-2. Miscellaneous Traps Trap Description ID Severity Cause System Up 1001 Server Administrator startup complete Information Server Administrator completed its initialization. Thermal Shutdown 1004 Thermal shutdown protection has been initiated Error This message is generated when a system is configured for thermal shutdown due to an error event.
book.book Page 664 Tuesday, August 5, 2008 9:15 AM Temperature Probe Traps Temperature probes help protect critical components by alerting the systems management console when temperatures become too high inside a chassis. The temperature probe traps use additional variables: sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius. Table 26-3.
book.book Page 665 Tuesday, August 5, 2008 9:15 AM Table 26-3. Temperature Probe Traps (continued) Trap ID Description Severity Cause Warning A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided.
book.book Page 666 Tuesday, August 5, 2008 9:15 AM Table 26-3. Temperature Probe Traps (continued) Trap ID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and temperature sensor value are provided.
book.book Page 667 Tuesday, August 5, 2008 9:15 AM Table 26-4. Cooling Device Traps (continued) Trap ID Description Severity Cause Warning A fan sensor reading in the specified system exceeded a warning threshold. The sensor location, chassis location, previous state, and fan sensor value are provided. Error A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value are provided.
book.book Page 668 Tuesday, August 5, 2008 9:15 AM Voltage Probe Traps Voltage probes monitor the number of volts across critical components. Table 26-5. Voltage Probe Traps Trap ID Description Severity Cause Voltage Probe Normal 1152 Voltage sensor returned to Information A voltage sensor in the specified system a normal value returned to a valid range Sensor location: after crossing a failure threshold.
book.book Page 669 Tuesday, August 5, 2008 9:15 AM Table 26-5. Voltage Probe Traps (continued) Trap ID Description Severity Cause Warning A voltage sensor in the specified system exceeded its warning threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Error A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided.
book.book Page 670 Tuesday, August 5, 2008 9:15 AM Table 26-5. Voltage Probe Traps (continued) Trap ID Description Severity Cause Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided.
book.book Page 671 Tuesday, August 5, 2008 9:15 AM Table 26-6. Amperage Probe Traps Trap ID Description Severity Cause Amperage Probe Normal 1202 Current sensor returned to Information A current sensor on the a normal value power supply for the specified system Sensor location: returned to a valid range after crossing a failure Chassis location:
book.book Page 672 Tuesday, August 5, 2008 9:15 AM Table 26-6. Amperage Probe Traps (continued) Trap ID Description Severity Cause Error A current sensor on the power supply for the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Error A current sensor in the specified system detected an error from which it cannot recover.
book.book Page 673 Tuesday, August 5, 2008 9:15 AM Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis. Table 26-7.
book.book Page 674 Tuesday, August 5, 2008 9:15 AM Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have "extra" fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed.
book.book Page 675 Tuesday, August 5, 2008 9:15 AM Table 26-8. Redundancy Unit Traps (continued) Trap ID Description Severity Cause Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, and previous redundancy state are provided.
book.book Page 676 Tuesday, August 5, 2008 9:15 AM Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. Table 26-9.
book.book Page 677 Tuesday, August 5, 2008 9:15 AM Table 26-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Warning 1353 Power supply detected a Warning warning Sensor location: Chassis location: Previous state was: A power supply sensor has detected a warning condition. The sensor location, chassis location, previous state, and additional power supply status information are provided.
book.book Page 678 Tuesday, August 5, 2008 9:15 AM Table 26-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Failure 1354 Power supply detected a Error failure Sensor location: Chassis location: A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided.
book.book Page 679 Tuesday, August 5, 2008 9:15 AM Table 26-10. Memory Device Messages Trap ID Description 1403 Severity Memory device status is Warning Memory device location: Possible memory module event cause: 1404 Memory device status is Error Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value.
book.book Page 680 Tuesday, August 5, 2008 9:15 AM Fan Enclosure Traps Some systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures for whether foreign objects are present and for how long a fan enclosure is absent from a chassis. Table 26-11.
book.book Page 681 Tuesday, August 5, 2008 9:15 AM AC Power Cord Traps The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord traps provide status and warning information for power cords that are part of an AC power switch, if your system supports AC switching. Table 26-12.
book.book Page 682 Tuesday, August 5, 2008 9:15 AM Hardware Log Traps Hardware logs provide hardware status messages to systems management software. On certain systems, the hardware log is implemented as a circular queue. When the log becomes full, the oldest status messages are overwritten when new status messages are logged. On some systems, the log is not circular. On these systems, when the log becomes full, subsequent hardware status messages are lost.
book.book Page 683 Tuesday, August 5, 2008 9:15 AM Processor Device Status Traps The BMC on some systems reports the status of processor devices. Processor device status traps provide status and warning information for processor devices present in a system with a BMC that reports the status of processor devices. Table 26-14.
book.book Page 684 Tuesday, August 5, 2008 9:15 AM Table 26-14. Processor Device Status Traps (continued) Trap ID Description Severity Cause Error A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided.
book.book Page 685 Tuesday, August 5, 2008 9:15 AM Table 26-15. Pluggable Device Traps (continued) Trap ID Description Severity Cause Pluggable Device Removal 1652 Device removed from system Information A device was removed from the specified system. The Device Location: device location, chassis location, and additional Chassis Location: are provided.
book.book Page 686 Tuesday, August 5, 2008 9:15 AM Battery Traps The BMC on some systems reports the status of batteries. Battery traps provide status and warning information for batteries present in a system with a BMC that reports the status of batteries. Table 26-16.
book.book Page 687 Tuesday, August 5, 2008 9:15 AM Table 26-16. Battery Traps (continued) Trap ID Description Severity Cause Battery Failure 1704 Battery sensor detected Critical a failure value Sensor Location: Chassis Location: A battery sensor in the specified system detected that a battery has failed. The sensor location, chassis location, previous state, and battery sensor status are provided.
book.book Page 688 Tuesday, August 5, 2008 9:15 AM Table 26-18.
book.book Page 689 Tuesday, August 5, 2008 9:15 AM Table 26-18. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause 1004 alertDrscFound The RAC is Information Error ESM communicat ing normally with the baseboard management controller (ESM) RAC DRAC III recovered communicati on with ESM. 1005 alertDrscPower The RAC Critical Off has detected a system power state change to poweredoff Error RAC DRAC III detected a system power state change to power-off.
book.book Page 690 Tuesday, August 5, 2008 9:15 AM Table 26-18. Enterprise-specific Traps (continued) Trap ID Name Description 1007 alertDrsc Watchdog Expired The RAC Critical has detected that the system watchdog has expired indicating a system hang Event RAC has DRAC III detected the system watchdog expired (normally indicating a system hang).
book.book Page 691 Tuesday, August 5, 2008 9:15 AM Table 26-18. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause 1010 alertDrscTemp The RAC Minor Temperature Warning probe has detected a Warning value Status RAC DRAC III temperature probe reading exceeded warning threshold. 1011 Critical alertDrscTemp The RAC Temperature Critical probe has detected a failure (or critical) value Error RAC DRAC III temperature probe reading exceeded critical threshold.
book.book Page 692 Tuesday, August 5, 2008 9:15 AM Table 26-18. Enterprise-specific Traps (continued) Trap ID Name Description 1015 alertDrscSEL Warning The RAC Major has detected a new event in the System Event Log with Severity: Warning Error RAC All detected a new system event log with warning severity (detailed log info is in drsAlert Message varbind).
book.book Page 693 Tuesday, August 5, 2008 9:15 AM Table 26-18. Enterprise-specific Traps (continued) Trap ID Name Description 1019 alertDrscSEL The RAC 100 system percentFull event log is 100% full 1020 alertDrscSEL Normal Severity Category Cause Major Status The RAC Information Error has detected a new event in the System Event Log with Severity: Normal Supported by RAC Platform RAC All detected system event log is 100% full.
book.book Page 694 Tuesday, August 5, 2008 9:15 AM Table 26-19.
book.book Page 695 Tuesday, August 5, 2008 9:15 AM Table 26-19.
book.book Page 696 Tuesday, August 5, 2008 9:15 AM Table 26-19.
book.book Page 697 Tuesday, August 5, 2008 9:15 AM Table 26-19.
book.
book.book Page 699 Tuesday, August 5, 2008 9:15 AM Storage Management Alert Reference Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up.
book.book Page 700 Tuesday, August 5, 2008 9:15 AM NOTE: You can also view these alerts in the Windows Event Viewer. Every alert consists of the following: • Severity — Shows the severity of alert. • Date and Time — Date and time when Storage Management logged the alert. • Description — A brief description of the alert. To expand or collapse the alert description, click the Description column heading. Alert Severity Levels Each alert message in the Storage Management alert log has a severity level.
book.book Page 701 Tuesday, August 5, 2008 9:15 AM SNMP Support for Storage Management Alerts By default, Storage Management installs SNMP trap forwarding support. For this support to function, you should have SNMP installed on the managed system prior to installing Storage Management. NOTE: For more information on installation requirements and SNMP, see the Server Administrator documentation.
book.book Page 702 Tuesday, August 5, 2008 9:15 AM SNMP Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. These variables are the following: • messageIDEvent • descriptionEvent • locationEvent • objectNameEvent • objectOIDEvent • objectNexusEvent • currentStatusEvent • previousStatusEvent Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console.
book.book Page 703 Tuesday, August 5, 2008 9:15 AM Standard Data Type Definitions This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
book.book Page 704 Tuesday, August 5, 2008 9:15 AM Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex.
book.book Page 705 Tuesday, August 5, 2008 9:15 AM Table A-3. Dell State Settings (continued) Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready. enableAndNotReady(6) The object is enabled and not ready. Table A-4.
book.book Page 706 Tuesday, August 5, 2008 9:15 AM Dell Status Data Types Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe. Table A-5. Dell Status Variable Name: DellStatus Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical.
book.book Page 707 Tuesday, August 5, 2008 9:15 AM Table A-7. Dell Status Probe Variable Name: DellStatusProbe Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The status of the object is unknown. ok(3) The status of the object is OK. nonCriticalUpper(4) The object is at the noncritical upper limit. CriticalUpper(5) The object is at the critical upper limit.
book.book Page 708 Tuesday, August 5, 2008 9:15 AM Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes.
book.book Page 709 Tuesday, August 5, 2008 9:15 AM SNMP Sample Output This sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB). Values are shown for each object identifier (OID) in the Instrumentation MIB Version Group, the Systems Management Software Group, the System State Group, the Chassis Information Table, and Event Log Table. The data is from a Dell™ PowerEdge™ 2650 system. Walk .1.3.6.1.4.1.674.
book.book Page 710 Tuesday, August 5, 2008 9:15 AM 1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0' 1.3.6.1.4.1.674.10892.1.100.11.0 = 0 1.3.6.1.4.1.674.10892.1.100.12.0 = 1 1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3 1.3.6.1.4.1.674.
book.book Page 711 Tuesday, August 5, 2008 9:15 AM 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 '\03\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 '\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 '\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.
book.book Page 712 Tuesday, August 5, 2008 9:15 AM 1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289 1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4 1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01' 1.3.6.1.4.1.674.10892.1.300.10.1.16.1 '20050513095213.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.17.1 '20050513100052.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.18.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.19.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.20.
book.book Page 713 Tuesday, August 5, 2008 9:15 AM 1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.45.1 = 0 1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 8 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 2 1.3.
book.
book.book Page 715 Tuesday, August 5, 2008 9:15 AM Glossary The following list defines or identifies technical terms, abbreviations, and acronyms used in Dell™ user documents. A Abbreviation for ampere(s). AC Abbreviation for alternating current. AC power switch A switch with two AC power inputs that provides AC power redundancy by failing over to a standby AC input in the event of a failure to the primary AC input. access Refers to the actions a user can take on a variable value.
book.book Page 716 Tuesday, August 5, 2008 9:15 AM ASIC Acronym for application-specific integrated circuit. ASPI Advanced SCSI programming interface. ASR Abbreviation for automatic system recovery. asset tag code An individual code assigned to a computer, usually by a system administrator, for security or tracking purposes. attribute An attribute, or property, contains a specific piece of information related to a component. Attributes can be combined to form groups.
book.book Page 717 Tuesday, August 5, 2008 9:15 AM BGA Abbreviation for Ball Grid Array, an IC package that uses an array of solder balls, instead of pins, to connect to a PC board. binary A base-2 numbering system that uses 0 and 1 to represent information. The computer performs operations based on the ordering and calculation of these numbers. BIOS Acronym for basic input/output system. Your computer’s BIOS contains programs stored on a flash memory chip.
book.book Page 718 Tuesday, August 5, 2008 9:15 AM bps Abbreviation for bits per second. BTU Abbreviation for British thermal unit. bus An information pathway between the components of a computer. Your computer contains an expansion bus that allows the microprocessor to communicate with controllers for all the various peripheral devices connected to the computer. Your computer also contains an address bus and a data bus for communications between the microprocessor and RAM.
book.book Page 719 Tuesday, August 5, 2008 9:15 AM chip A set of microminiaturized, electronic circuits that are designed for use as processors and memory in computers. Small chips can hold from a handful to tens of thousands of transistors. They look like tiny chips of aluminum, no more than 1/16" square by 1/30" thick, which is where the term "chip" came from. Large chips, which can be more than a half inch square, hold millions of transistors.
book.book Page 720 Tuesday, August 5, 2008 9:15 AM config.sys file The config.sys file is executed when you boot your computer (before running any commands in the autoexec.bat file). This start-up file contains commands that specify which devices to install and which drivers to use. This file also contains commands that determine how the operating system uses memory and controls files.
book.book Page 721 Tuesday, August 5, 2008 9:15 AM cursor A marker, such as a block, underscore, or pointer that represents the position at which the next keyboard or mouse action will occur. DAT Acronym for digital audio tape. dB Abbreviation for decibel(s). dBA Abbreviation for adjusted decibel(s). DC Abbreviation for direct current. device driver A program that allows the operating system or some other program to interface correctly with a peripheral device, such as a printer.
book.book Page 722 Tuesday, August 5, 2008 9:15 AM directory Directories help keep related files organized on a disk in a hierarchical, "inverted tree" structure. Each disk has a "root" directory; for example, a C:\> prompt normally indicates that you are at the root directory of hard-drive C. Additional directories that branch off of the root directory are called subdirectories. Subdirectories may contain additional directories branching off of them. display adapter See video adapter.
book.book Page 723 Tuesday, August 5, 2008 9:15 AM DRAM Acronym for dynamic random-access memory. A computer’s RAM is usually made up entirely of DRAM chips. Because DRAM chips cannot store an electrical charge indefinitely, your computer continually refreshes each DRAM chip in the computer. drive-type number Your computer can recognize a number of specific hard drives. Each is assigned a drive-type number that is stored in NVRAM.
book.book Page 724 Tuesday, August 5, 2008 9:15 AM EIDE Abbreviation for enhanced integrated drive electronics.
book.book Page 725 Tuesday, August 5, 2008 9:15 AM ESD Abbreviation for electrostatic discharge. ESM Abbreviation for Embedded Systems Management. expanded memory A technique for accessing RAM above 1 MB. To enable expanded memory on your computer, you must use an EMM. You should configure your system to support expanded memory only if you run application programs that can use (or require) expanded memory.
book.book Page 726 Tuesday, August 5, 2008 9:15 AM FEPROM Acronym for Flash Erasable Programmable Read-Only Memory. Flash memory is a kind of non-volatile storage device similar to EEPROM, but the erasing is done only in blocks or the entire chip. flash BIOS A PC BIOS that is stored in flash memory rather than in a ROM. A flash BIOS chip can be updated in place, whereas a ROM BIOS must be replaced with a newer chip.
book.book Page 727 Tuesday, August 5, 2008 9:15 AM graphics coprocessor See coprocessor. graphics mode A video mode that can be defined as x horizontal by y vertical pixels by z colors. group As it relates to DMI, a group is a data structure that defines common information, or attributes, about a manageable component. GTL Abbreviation for ground termination logic. GUI Acronym for graphical user interface. h Abbreviation for hexadecimal.
book.book Page 728 Tuesday, August 5, 2008 9:15 AM hot plug The ability to remove and replace a redundant part while the system is being used. Also called a "hot spare." HPFS Abbreviation for the High Performance File System option in the Windows NT operating systems. Hz Abbreviation for hertz. ICES Abbreviation for Interface-Causing Equipment Standard (in Canada). ICU Abbreviation for ISA Configuration Utility. IDE Abbreviation for Integrated Device Electronics.
book.book Page 729 Tuesday, August 5, 2008 9:15 AM internal microprocessor cache An instruction and data cache built in to the microprocessor. The Intel Pentium microprocessor includes a 16-KB internal cache, which is set up as an 8-KB readonly instruction cache and an 8-KB read/write data cache. IP Address Abbreviation for Internet Protocol address. See TCP/IP.
book.book Page 730 Tuesday, August 5, 2008 9:15 AM K Abbreviation for kilo-, indicating 1,000. KB Abbreviation for kilobyte(s), 1,024 bytes. KB/sec Abbreviation for kilobyte(s) per second. Kbit(s) Abbreviation for kilobit(s), 1,024 bits. Kbit(s)/sec Abbreviation for kilobit(s) per second. key combination A command requiring you to press multiple keys at the same time. For example, you can reboot your computer by pressing the key combination.
book.book Page 731 Tuesday, August 5, 2008 9:15 AM LED Abbreviation for light-emitting diode. An electronic device that lights up when a current is passed through it. local bus On a computer with local-bus expansion capability, certain peripheral devices (such as the video adapter circuitry) can be designed to run much faster than they would with a traditional expansion bus.
book.book Page 732 Tuesday, August 5, 2008 9:15 AM Mbps Abbreviation for megabits per second. MBR Abbreviation for master boot record. MCA Abbreviation for Micro Channel Architecture, which is designed for multiprocessing. MCA eliminates potential conflicts that arise when installing new peripheral devices. MCA is not compatible with either EISA or XT bus architecture, so older cards cannot be used with it.
book.book Page 733 Tuesday, August 5, 2008 9:15 AM MIDI Abbreviation for musical instrument digital interface. MIF Acronym for management information format. A MIF file contains information, status, and links to component instrumentation. MIF files are installed into the MIF database by the DMI service layer. The content of a MIF is defined by a DTMF working committee and is published in the form of a MIF definition document.
book.book Page 734 Tuesday, August 5, 2008 9:15 AM mV Abbreviation for millivolt(s). name The name of an object or variable is the exact string that identifies it in an SNMP Management Information Base (MIB) file, or in a DMI Management Information Format (MIF) file, or in a CIM Management Object File (MOF). NDIS Abbreviation for Network Driver Interface Specification. NIC Acronym for network interface controller. NIF Acronym for network interface function. This term is equivalent to NIC.
book.book Page 735 Tuesday, August 5, 2008 9:15 AM OID Abbreviation for object identifier. An implementation-specific integer or pointer that uniquely identifies an object. online access service A service that typically provides access to the Internet, E-mail, bulletin boards, chat rooms, and file libraries. OTP Abbreviation for one-time programmable. parallel port An I/O port used most often to connect a parallel printer to your computer.
book.book Page 736 Tuesday, August 5, 2008 9:15 AM PCI Abbreviation for Peripheral Component Interconnect. A standard for local-bus implementation developed by Intel Corporation. PCIX Abbreviation for PCI extended. PCMCIA Personal Computer Memory Card International Association. An international trade association that has developed standards for devices, such as modems and external hard drives, that can be plugged into portable computers. PERC Acronym for PowerEdge™ Expandable RAID controller.
book.book Page 737 Tuesday, August 5, 2008 9:15 AM pixel A single point on a video display. Pixels are arranged in rows and columns to create an image. A video resolution, such as 640 x 480, is expressed as the number of pixels across by the number of pixels up and down. PLCC Acronym for plastic leaded chip carrier. Plug and Play An industry-standard specification that makes it easier to add hardware devices to personal computers.
book.book Page 738 Tuesday, August 5, 2008 9:15 AM protected mode An operating mode supported by 80286 or higher microprocessors, protected mode allows operating systems to implement: • A memory address space of 16 MB (80286 microprocessor) to 4 GB (Intel386 or higher microprocessor) • Multitasking • Virtual memory, a method for increasing addressable memory by using the hard drive Windows, OS/2, and UNIX® 32-bit operating systems run in protected mode.
book.book Page 739 Tuesday, August 5, 2008 9:15 AM RAW Unprocessed. The term refers to data that is passed along to an I/O device without being interpreted. In contrast, cooked refers to data that is processed before being passed to the I/O device. It often refers to uncompressed text that is not stored in any proprietary format. The term comes from UNIX, which supports cooked and raw modes for data output to a terminal. RDRAM Acronym for Rambus DRAM. A dynamic RAM chip technology from Rambus, Inc.
book.book Page 740 Tuesday, August 5, 2008 9:15 AM refresh rate The rate at which the monitor redraws the video image on the monitor screen. More precisely, the refresh rate is the frequency, measured in Hz, at which the screen’s horizontal lines are recharged (sometimes also referred to as its vertical frequency). The higher the refresh rate, the less video flicker can be seen by the human eye. The higher refresh rates are also noninterlaced. RFI Abbreviation for radio frequency interference.
book.book Page 741 Tuesday, August 5, 2008 9:15 AM SCSI Acronym for small computer system interface. An I/O bus interface with faster data transmission rates than standard ports. You can connect up to seven devices (15 for some newer SCSI types) to one SCSI interface. SDMS Abbreviation for SCSI device management system. sec Abbreviation for second(s). SEC Abbreviation for single-edge contact. serial port An I/O port used most often to connect a modem to your computer.
book.book Page 742 Tuesday, August 5, 2008 9:15 AM SIMD Abbreviation for Single Instruction Multiple Data. SIMM Acronym for single in-line memory module. A small circuit board containing DRAM chips that connects to the system board. SIP Acronym for single in-line package, which is a type of housing for electronic components in which the connecting pins protrude from one side. A SIP is also called a Single In-line Pin Package (SIPP). SKU Acronym for stock keeping unit.
book.book Page 743 Tuesday, August 5, 2008 9:15 AM SOJ Acronym for small outline package J-lead, a small-dimension, plastic, rectangular surface mount chip package with j-shaped pins on its two long sides. SRAM Abbreviation for static random-access memory. Because SRAM chips do not require continual refreshing, they are substantially faster than DRAM chips. state Refers to the condition of an object that can have more than one condition. For example, an object may be in the "not ready" state.
book.book Page 744 Tuesday, August 5, 2008 9:15 AM system board As the main circuit board, the system board usually contains most of your computer’s integral components, such as the following: • Microprocessor • RAM • Controllers for standard peripheral devices, such as the keyboard • Various ROM chips Frequently used synonyms for system board are motherboard and logic board.
book.book Page 745 Tuesday, August 5, 2008 9:15 AM table In SNMP MIBs, a table is a two dimensional array that describes the variables that make up a managed object. TCP/IP Abbreviation for Transmission Control Protocol/Internet Protocol. A system for transferring information over a computer network containing dissimilar systems, such as systems running Windows and UNIX.
book.book Page 746 Tuesday, August 5, 2008 9:15 AM time-out A specified period of system inactivity that must occur before an energy conservation feature is activated. tpi Abbreviation for tracks per inch. TQFP Acronym for thin quad flat pack. TSR Abbreviation for terminate-and-stay-resident. A TSR program runs "in the background.
book.book Page 747 Tuesday, August 5, 2008 9:15 AM unicode A fixed width, 16-bit world wide character encoding, developed and maintained by the Unicode Consortium. upper memory area The 384 KB of RAM located between 640 KB and 1 MB. If the computer has an Intel386 or higher microprocessor, a utility called a memory manager can create UMBs in the upper memory area, in which you can load device drivers and memory-resident programs. UPS Abbreviation for uninterruptible power supply.
book.book Page 748 Tuesday, August 5, 2008 9:15 AM variable A component of a managed object. A temperature probe, for example, has a variable to describe its capabilities, its health or status, and certain indexes that you can use to help you in locating the right temperature probe. VCCI Abbreviation for Voluntary Control Council for Interference. VCR Abbreviation for video cassette recorder. VDC Abbreviation for volt(s) direct current. VESA Acronym for Video Electronics Standards Association.
book.book Page 749 Tuesday, August 5, 2008 9:15 AM video adapter The logical circuitry that provides—in combination with the monitor—your computer’s video capabilities. A video adapter may support more or fewer features than a specific monitor offers. Typically, a video adapter comes with video drivers for displaying popular application programs and operating systems in a variety of video modes. On some Dell computers, a video adapter is integrated into the system board.
book.book Page 750 Tuesday, August 5, 2008 9:15 AM virtual memory A method for increasing addressable RAM by using the hard drive. For example, in a computer with 16 MB of RAM and 16 MB of virtual memory set up on the hard drive, the operating system would manage the system as though it had 32 MB of physical RAM. virus A self-starting program designed to inconvenience you.
book.book Page 751 Tuesday, August 5, 2008 9:15 AM Wakeup on LAN The ability for the power in a client station to be turned on by the network. Remote wake-up enables software upgrading and other management tasks to be performed on users' machines after the work day is over. It also enables remote users to gain access to machines that have been turned off. Intel calls remote wake-up "Wakeon-LAN." WH Abbreviation for watt-hour(s). win.ini file A start-up file for the Windows operating system.
book.book Page 752 Tuesday, August 5, 2008 9:15 AM XMS Abbreviation for eXtended Memory Specification. ZIF Acronym for zero insertion force. Some computers use ZIF sockets and connectors to allow devices such as the microprocessor chip to be installed or removed with no stress applied to the device. ZIP A 3.5 inch removable disk drive from Iomega. Originally, it provided a 100 MB removable cartridges. The drive is bundled with software that can catalog the disks and lock the files for security.
book.
book.
book.
book.
book.
book.