Dell EMC PowerEdge T150 Technical Specifications Part Number: E80S Regulatory Type: E80S001 March 2022 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: Technical specifications............................................................................................... 4 Chassis dimensions..............................................................................................................................................................4 System weight......................................................................................................................................................................
1 Technical specifications The technical and environmental specifications of your system are outlined in this section.
Table 1. Chassis dimension for the PowerEdge T150 system Drives Xa Xb Ya Yb Yc Za Zb Zc 4 x 3.5inch 175 mm (6.88 inches) NA 360 mm (14.17 inches) 362.9 mm (14.28 inches) NA With bezel : 35 mm (17 inches) 400 mm (15.74 inches) 418.75 mm (16.48 inches) Without bezel : NA NOTE: Zb is the nominal rear wall external surface where the system board I/O connectors reside. System weight Table 2. PowerEdge T150 system weight System configuration Maximum weight (with all drives/SSDs) 4 x 3.
Supported operating systems The PowerEdge T150 system supports the following operating systems: ● ● ● ● ● Canonical Ubuntu Server LTS VMware ESXi Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Server For more information, go to www.dell.com/ossupport. Cooling fans specifications The PowerEdge T150 system supports the following: ● One system cooling fan located at the back of the system. ● One processor cooling fan located on the heat sink.
Table 6. Memory specifications Single processor DIMM type DIMM rank DIMM capacity Single rank UDIMM Dual rank Minimum DIMM capacity Maximum DIMM capacity 8 GB 8 GB 32 GB 16 GB 16 GB 64 GB 32 GB 32 GB 128 GB Table 7. Memory module sockets Memory module sockets Speed 4, 288-pin 3200 MT/s, 2933 MT/s, 2666 MT/s NOTE: 32 GB x 4 supports 2933 MT/s. NOTE: For Pentium processor, maximum memory speed supported is 2666 MT/s.
NOTE: The micro-AB USB 2.0-compliant port can only be used as an iDRAC Direct or a management port. NIC port specifications The PowerEdge T150 system supports up to two Onboard LOM 1GbE. Serial connector specifications The PowerEdge T150 system supports one serial connector on rear of the system, which is a 9-pin connector, Data Terminal Equipment (DTE), 16550-compliant . VGA ports specifications The PowerEdge T150 system supports one DB-15 VGA port on the rear panel of the system.
Table 11. Operational climatic range category A2 (continued) Temperature Specifications Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft) Table 12.
Table 16. Particulate contamination specifications Particulate contamination Specifications Air filtration Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. NOTE: Air entering the data center must have MERV11 or MERV13 filtration.