Accelerate vSAN Deployments with Broadcom NetXtreme
Ethernet Adapters
Tech Note by:
Seamus Jones Dell EMC
Robert Lusinsky Broadcom
SUMMARY
Dell EMC PowerEdge servers
equipped with Broadcom
NetXtreme 10/25Gb Ethernet
solutions provide the building
blocks to simplify deployment
and speed scaling with
unmatched performance.
Within this paper we discuss
the impact 10/25Gb
NetXtreme Ethernet Adapters
can have on a PowerEdge
R740xd vSAN Cluster
Proof of concept performance
testing and results discussed
were achieved utilizing
industry standard HCIBench
on a PowerEdge R740xd
vSAN Cluster at Broadcom
laboratories
Improve vSAN Performance with 10/25Gb Ethernet
When considering performance reliant applications within the datacenter customers
are always considering server and adapter choices that will have the broadest impact
for dollar spend. Often times customers want to verify that the changes made will
impact the application requirements for high speed network performance. As more
applications become optimized for a vSAN distributed layer of software included in
the ESCi hypervisor. The features such as High Availability (HA), vMotion, and
Distributed Resource Scheduler (DRS) require efficiency within the stack. Since
each host in a vSAN cluster can contribute storage to the cluster it is essential to
evaluate and eliminate any potential throttle points in the architecture which could
reduce application performance.
Dell EMC PowerEdge R740, R640 and R940 servers include Broadcom NetXtreme
10Gb Ethernet adapters in the default server configurations. Enterprise customers
have moved from 1Gb to 10/25Gb at an accelerated pace since 10/25Gb provides
clear benefits to accelerate customers’ use case deployments, which translates to
better value, better service and lower TCO for the customer.
To determine the full impact Broadcom have conducted some testing utilizing Hyper-
converged Infrastructure Benchmark (HCIBench) to determine testing in a consistent
and controlled manner. The results of which will give us an excellent performance
comparison between network speeds. The results here are key indicators for
expected performance gain from a 10/25Gb Ethernet deployment
vSAN Test Node Configuration
PowerEdge R740xd Node Configuration
2 x Intel Xeon Gold 6134
8C/16T 3.2GHz
12 x 32GB RDIMM 2666MT/s Dual Rank
HBA330 12Gbps
Boot: BOSS controller card 2x M.2 240G RAID 1
Cache Tier: 4 x Dell 800GB NVMe PM1725a
Capacity Tier: 8 x 1.92TB SSD SAS Read Intensive 12Gbps
Physical Topology
Logical Topology

Summary of content (2 pages)