Dell EqualLogic PS4210 Storage Arrays Installation and Setup Guide
Dell EqualLogic PS4210 Storage Arrays Installation and Setup Guide Version 1.
© Copyright 2014 Dell Inc. All rights reserved. Dell™ and EqualLogic® are trademarks of Dell Inc. All trademarks and registered trademarks mentioned herein are the property of their respective owners. Information in this document is subject to change without notice. Reproduction of this material in any manner whatsoever without the written permission of Dell is strictly forbidden.
Table of Contents Preface 1 Understanding the Array Installation Procedure 2 Rack Mounting the Array Before You Begin Protecting Hardware Steps for Mounting an Array in a Rack 3 Connecting the Array Cables Network Requirements and Recommendations Minimum and Recommended Cable Configurations Connect and Secure the Power Cables Connect the Array to the Network Set Up a Serial Connection to the Array 4 Software Configuration Choose a Configuration Method Collect Configuration Information Start the Software C
Installation and Setup Guide iv Table of Contents
Preface Dell™ EqualLogic® PS Series arrays optimize resources by automating capacity, performance, and network load balancing. Additionally, PS Series arrays offer all-inclusive array management software and firmware updates. Dell EqualLogic FS Series appliances, combined with PS Series arrays, offer a high-performance, highavailability, scalable NAS solution. Audience The information in this guide is intended for hardware administrators.
Installation and Setup Guide Preface Contacting Dell Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services might not be available in your area. To contact Dell EqualLogic Technical Support by phone, if you are located in the United States, call 800-9453355. For a listing of International Dell EqualLogic support numbers, visit dell.com/support/home.
1 Understanding the Array Installation Procedure To set up your array and start using the iSCSI SAN array, follow these steps: 1. Install the array in a rack. See Rack Mounting the Array on page 3. 2. Connect the array to power and the network. See Connect and Secure the Power Cables on page 11 and Connect the Array to the Network on page 12. 3. Configure the PS Series software. First, initialize an array to make it accessible on the network.
PS4210 Hardware Owner's Manual 2 1 Understanding the Array Installation Procedure
2 Rack Mounting the Array For proper operation, a PS Series storage array must be properly installed in a rack. This section contains general electrostatic, safety, network, and installation information for PS Series arrays. After installing the array in a rack, connect the power and network cables, as described in Chapter 3. Before You Begin Before installing the array: • Register for a Dell™ EqualLogic® Customer Support Account. If you do not have a customer service support account, go to eqlsupport.
PS4210 Installation Guide • • • • • • 2 Rack Mounting the Array For the ReadyRails™ II rail kits, the distance between the outside surfaces of the front and rear rack posts (the mounting surfaces) can range from 595 mm to 914 mm (23.4” to 36.0”) for square-hole racks, 581 mm to 907 mm (22.9” to 35.7”) for round-hole racks, and 595 mm to 929 mm (23.4” to 36.6”) for threaded-hole racks. The rack is secured to the floor for added stability. Load a rack with arrays from the bottom to the top.
PS4210 Installation Guide 2 Rack Mounting the Array 3. Connect the band to ground. You can either plug the banana connector into a matching grounded receptacle, or attach it to the matching alligator clip and connect the clip to a grounded device. Examples of an appropriate ground would be an ESD mat or the metal frame of a grounded piece of equipment. Shipping Box Contents and Required Hardware Make sure you have all the items supplied in the shipping box, described in Table 1.
PS4210 Installation Guide 2 Rack Mounting the Array Optional Hardware You can optionally use an uninterruptible power supply system (UPS) to provide a highly available source of power to an array. Each UPS (not included) should be on a different circuit and must provide the correct type of voltage for an adequate amount of time. Steps for Mounting an Array in a Rack To mount an array in a rack, follow these steps: 1. Determine where to place the mounting rails in the rack. 2.
PS4210 Installation Guide 2 Rack Mounting the Array Figure 2: Installing the Array Into the Rack Figure 3 shows the front view of the 3.5-inch drive array. Figure 3: 3.5-Inch Drive Array - Front View (Without Bezel) Figure 4 shows the front view of the 2.5-inch drive array. Figure 4: 2.5-Inch Drive Array - Front View (Without Bezel) With assistance, lift the array, keeping the array level, and slide it onto the mounting rails until the array engages.
PS4210 Installation Guide 2 Rack Mounting the Array Installing the Bezel The steps for installing the bezel are the same for all array models: 1. Hook the right end of the bezel onto the right side of the chassis. 2. Swing the left end of the bezel toward the left side of the chassis. 3. Press the bezel into place until the release latch closes. 4. Using the key provided, lock the bezel and store the key in a safe place as shown in Figure 5.
3 Connecting the Array Cables After you install the array in a rack, you must connect the network and power cables and, optionally, the serial cables. First, review the network recommendations in Minimum and Recommended Cable Configurations on page 10. The following list describes the general steps for connecting the array to power and the network: 1. Connect the power cables. Do not turn on power to the array at this time. See Connect and Secure the Power Cables on page 11. 2.
PS4210 Installation Guide Recommendation Management network (optional) 3 Connecting the Array Cables Description Connect the management ports on both control modules to a 10/100Mbps network switch to keep management traffic separate from iSCSI traffic. Access to the group IP address (Hosts) In a multi-subnet group, each configured network interface should have access to the subnet on which the group IP address resides.
PS4210 Installation Guide 3 Connecting the Array Cables Figure 6: Recommended Network Configurations Connect and Secure the Power Cables Obtain the power cables that were shipped with the array. If the array was not shipped with power cables, contact your PS Series support provider or reseller for power cable information. 1. Make sure that the power switch is in the OFF (O) position before connecting the power cables. 2. Connect the power cables to the power supplies as shown in . 3.
PS4210 Installation Guide 3 Connecting the Array Cables – Plug the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).The bottom LED of the power supply will be illuminated green (indicating power is present) when power cables are connected. – Each UPS (not included) should be on a different circuit and must provide the correct type of voltage for an adequate amount of time.
PS4210 Installation Guide 3 Connecting the Array Cables 1. Find the power switch, located either below the power plug. See Figure 8. 2. Press the power switch to the ON position. The power indicators will light. Batteries will start to charge and some hardware components will start to synchronize. LEDs will indicate these normal activities. The battery backup unit installed in each controller is shipped in a partially discharged state.
PS4210 Installation Guide 3 Connecting the Array Cables See Figure 9 (not to scale). The serial connection must have the following characteristics: • 9600 baud • One STOP bit • No parity • 8 data bits • No flow control Note: Keep the serial cable. You need the serial cable to manage the group, or a specific array, if there is no network access.
PS4210 Installation Guide 3 Connecting the Array Cables Serial Cable Pinout Information Figure 10 shows the pin locations on the DB9 connectors on the serial cable shipped with the array, and Table 5 lists the pinout information for the cable.
PS4210 Installation Guide 16 3 Connecting the Array Cables
4 Software Configuration After you complete the array hardware installation, you can initialize the array and create a PS Series group with the array as the first group member. Alternately, you can add the array to an existing group. When you expand a group, capacity and performance scale automatically with no impact on users. After completing the software configuration, you can allocate storage and start using the iSCSI SAN array. See Storage Allocation on page 23.
PS4210 Installation Guide Prompt Default gateway (optional) RAID policy 4 Software Configuration Description Network address for the device used to connect subnets and forward network traffic beyond the local network. A default gateway is needed only if you want the array network interface to communicate outside the local network (for example, to allow access to volumes from computers outside the local network). The default gateway must be on the same subnet as the array network interface.
PS4210 Installation Guide 4 Software Configuration After you complete the software configuration, the array becomes a member of a group and its disk storage is available for use. Using the Setup Utility to Configure the Software To use the setup utility to initialize an array and create or expand a group: 1. On the console or terminal emulator that has the serial connection to the array, press the Enter key.
PS4210 Installation Guide 4 Software Configuration Searching to see if the group exists. This may take a few minutes. The group does not exist or currently cannot be reached. Make sure you have entered the correct group IP address and group name. Do you want to create a new group (yes | no) [yes]? yes Group Configuration Group Name: group1 Group IP address: 192.17.2.
PS4210 Installation Guide 4 Software Configuration Set the Member RAID Policy The storage space in a new group member (array) is not available until you configure a RAID policy on the member. A RAID policy consists of a RAID level and a spare disk configuration. When you select a RAID policy, the member’s disks are automatically configured with the selected RAID level and the appropriate number of spare disks.
PS4210 Installation Guide 4 Software Configuration 3. Click Yes in the warning dialog box to open the Configure Member – General Settings dialog box. 4. Select the pool and click Next. If prompted, confirm you want to assign the member to the pool. 5. Select the RAID policy on the Configure Member – RAID Configuration dialog box. 6. (Optional) Select Wait until the member storage initialization completes. 7. Click Next. 8. Click Finish in the Configure Member – Summary dialog box.
5 Storage Allocation Allocating group storage space to users involves the following steps: 1. Create a Volume on page 23. 2. Connect a Computer to a Volume on page 27. After allocating storage, you can customize the group and use its more advanced features. See Where to Go After Setting Up a Group on page 29. Create a Volume To allocate group storage space to users and applications, use the Group Manager CLI or GUI to create volumes. A volume appears on the network as an iSCSI target.
PS4210 Installation Guide 5 Storage Allocation • ipaddress ip_address You can create a maximum of 16 access control records for a volume. The following example creates a 50GB volume and one access control record. Only a computer with the specified initiator name will be able to access the volume. group1> volume create staff1 50GB group1> volume select staff1 access create initiator iqn.199105.com.microsoft:WIN2008Server.company.
PS4210 Installation Guide Field Description 5 Storage Allocation Shortcut Key Create volume in folder If the group has volume folders, check this checkbox and select a folder from the drop-down list to create the volume in this folder. Folders help you organize large collections of volumes into logical groups. Volumes can also be moved into folders after they are created. Alt+F Storage pool assignment If the group has multiple storage pools, select the storage pool you want to create the volume in.
PS4210 Installation Guide 5 Storage Allocation Field Shortcut Key Description Estimated This table estimates how the currently proposed volume size changes in and snapshot settings affect the existing space in the storage pool designated storage pool. default None Step 3: Configure iSCSI Access Field What kind of access type do you want for this volume? Description Allows you to set the access controls for the volume.
PS4210 Installation Guide Field Description 5 Storage Allocation Shortcut Key New Click New to define a new access policy or policy group. None Edit From either the Available list or the Selected list, select an access policy or policy group and click Edit to change it. None Step 4: Sector Size Field Description Shortcut Key You can create volumes that use either 512-byte or 4KB sectors. The sector size of a volume has no dependency on the sector size of the physical drives in the array.
PS4210 Installation Guide 5 Storage Allocation 1. Install and configure an iSCSI initiator on the computer. Hardware and software initiators are available from different vendors. Configure your initiator using the instructions provided by the vendor. Note: Dell recommends that you visit the Technical Support website to obtain important information about using initiators to access PS Series group volumes. 2. Make sure that the computer matches one of the volume’s access control records.
6 Where to Go After Setting Up a Group After setting up a group, you can customize the group in order to more effectively manage your storage environment. You can also begin to use the full set of product features. The following documentation and additional products are included in the purchase of your array and are available at any time. • The Hardware Owner's Manual provides basic storage array information, maintenance information, and troubleshooting information for your PS Series storage array hardware.
PS4210 Installation Guide Task 6 Where to Go After Setting Up a Group Description such as firmware upgrades. Accounts can be configured to be authenticated through the PS Series group, RADIUS, or by using LDAP or Active Directory authentication. Set up event notification To be informed of significant events in a timely manner, set up email or syslog notification. Configure SNMP To monitor traps from the group, you can use SNMP.
7 Other Information You Might Need See the safety and regulatory information that shipped with your system. Warranty information might be included within this document or as a separate document. • The rack documentation included with your rack solution describes how to install your system into a rack. • The Hardware Owner's Manual provides information about system features and describes how to troubleshoot the system and install or replace system components. This document is available online at eqlsupport.
PS4210 Installation Guide 7 Other Information You Might Need Power Supplies Under typical line conditions and over the entire system ambient operating range, the inrush current might reach 55A per power supply for 10 ms or less. Physical Height 2U: 8.68 cm (3.41 inches) 8.68 cm (3.41 inches) Width 44.63 cm (17.57 inches) Depth PS4210 E (3.5-inch drives): 57.5 cm (22.6 inches) PS4210 X, XV (2.5-inch drives) 54.1 cm (21.3 inches) Weight (fully loaded array) PS4210X, XV (2.5-inch drives), S, XS: 24.
PS4210 Installation Guide 7 Other Information You Might Need Environmental level Acoustics • Active mode: 7.
PS4210 Installation Guide 34 7 Other Information You Might Need
Index G A access control records creating 24 access controls setting up with CLI 23 accounts configuring after setup 29 array choosing where to mount 6 initializing 17 mounting in rack 6 network address 17 RAID policy 21 software configuration 17 Gigabit Ethernet recommendation 9 group accessing volumes from a computer 28 advanced tasks 29 creating 17 customizing after setup 29 expanding 17 IP address 18 logging in to CLI 21 logging in to GUI 21 name 18 GUI setting RAID policy 21 H B hardware require
Index: netmask – volumes S N safety precautions netmask member setting 17 installation 3 serial cable network array IP address 17 configuring multiple interfaces 29 group IP address 18 improving performance 9 recommendations 9 requirements 9 network cables 12 network interfaces configuring 17 NTP server characteristics 15 connecting 13 pin locations 15 pinout information 15 setup utility configuring the software 19 description 17 requirements 17 shipping box contents 5 snapshots configuring 30