Power Supply Profile Document Number: DCIM1047 Document Type: Specification Document Status: Published Document Language: E Date: 2011-08-09 Version: 2.0.
THIS PROFILE IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND. ABSENT A SEPARATE AGREEMENT BETWEEN YOU AND DELL™ WITH REGARD TO FEEDBACK TO DELL ON THIS PROFILE SPECIFICATION, YOU AGREE ANY FEEDBACK YOU PROVIDE TO DELL REGARDING THIS PROFILE SPECIFICATION WILL BE OWNED AND CAN BE FREELY USED BY DELL. © 2010 Dell Inc. All rights reserved.
CONTENTS 1 2 3 4 5 6 7 Scope .................................................................................................................................................... 5 Normative References........................................................................................................................... 5 Terms and Definitions ........................................................................................................................... 5 Symbols and Abbreviated Terms .......
Figures Figure 1 – Power Supply Profile Implementation .......................................................................................... 8 Tables Table 1 – Related Profiles ............................................................................................................................. 7 Table 2 – Class Requirements: Power Supply Profile .................................................................................. 9 Table 3 – DCIM_PowerSupplyView - Operations .....................
Power Supply Profile 1 Scope The DCIM Power Supply Profile describes the properties and interfaces for executing system management tasks related to the management of power supplies within a system. The profile standardizes and aggregates the description for the power supply properties into a power supply view representation as well as provides static methodology for the clients to query the power supply views without substantial traversal of the model.
3.6 shall indicates requirements to be followed strictly in order to conform to the document and from which no deviation is permitted 3.7 FQDD Fully Qualified Device Descriptor is used to identify a particular component in a system. 3.8 Interop Namespace Interop Namespace is where instrumentation instantiates classes to advertise its capabilities for client discovery. 3.
5 Synopsis Profile Name: Power Supply Version: 2.0.0 Organization: Dell CIM Schema Version: 2.21.0 Experimental Dell Schema Version: 1.0.0 Interop Namespace: root/interop Implementation Namespace: root/dcim Central Class: DCIM_PowerSupplyView Scoping Class: DCIM_ComputerSystem The Dell Power Supply Profile is a component profile that contains the Dell specific implementation requirements for power supply view. DCIM_PowerSupplyView shall be the Central Class.
6 Description The Dell Power Supply Profile describes platform’s power supply information. Each platform power supply is represented by an instance of DCIM_PowerSupplyView class. Figure 1 details typical Dell Power Supply Profile implementation for a platform containing two power supplies. In order for client to discover the instrumentation’s support of this profile, PowerSupplyProfile is instantiated in the Interop Namespace.
7 Implementation Description This section describes the requirements and guidelines for implementing Dell Power Supply Profile. Table 2 – Class Requirements: Power Supply Profile Element Name Requirement Description DCIM_PowerSupplyView Mandatory The class shall be implemented in the Implementation Namespace. See section7.1. DCIM_LCElementConformsToProfile Mandatory The class shall be implemented in the Implementation Namespace.
7.1.3 Properties The following table details the implemented properties for DCIM_PowerSupplyView instance representing a power supply in a system. The “Requirements” column shall denote the implementation requirement for the corresponding property.
7.2 Power Supply Profile Profile Registration This section describes the implementation for the DCIM_LCRegisteredProfile class. This class shall be instantiated in the Interop Namespace. The DCIM_LCElementConformsToProfile association(s) shall reference the DCIM_LCRegisteredProfile instance. 7.2.1 Resource URIs for WinRM® The class Resource URI shall be "http://schemas.dmtf.
8 Methods This section details the requirements for supporting extrinsic methods for the CIM elements defined by this profile. No additional details specified. 9 Use Cases This section contains use cases for the Dell PowerSupply Profile. Note that URIs in this section are in form of Resource URIs for WinRM®. 9.
RegisteredName = Power Supply, OtherRegisteredOrganization = DCIM, RegisteredVersion = 2.0.0 9.2 Inventory of power supplies in system Enumerate the DCIM_PowerSupplyView class to view all available instances of the class Class URI: http://schemas.dell.com/wbem/wscim/1/cimschema/2/DCIM_PowerSupplyView?__cimnamespace=root/dcim The instance information of all available power supplies will be returned 9.
ANNEX A (informative) Related MOF Files Dell Tech Center MOF Library: http://www.delltechcenter.com/page/DCIM.Library.MOF Related Managed Object Format (MOF) files: DCIM_PowerSupplyView.mof DCIM_LCEnumeration.mof DCIM_LCRegisteredProfile.mof 14 Version 2.0.
ANNEX B (informative) Change Log Version 2.0.1 Version 2.0.1 Date 2011-08-09 Description Removed the RedTypeOfSet property from DCIM_PowerSupplyView class as the property was never implemented.