Dell EMC SD-WAN Edge 600 Series Installation Guide
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 About this guide........................................................................................................................... 5 Related documents............................................................................................................................................................... 5 Information symbols..............................................................................................................................................................
Taiwanese certification of compliance........................................................................................................................26 Singapore certification of compliance.........................................................................................................................26 Product recycling and disposal.......................................................................................................................................... 27 7 Dell EMC support.
1 About this guide This guide provides site preparation recommendations, step-by-step procedures for installing your device, and connecting to a power source. CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. NOTE: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment. This equipment contains two power cables. Disconnect both power cables before servicing.
NOTE: The Warning icon signals information about hardware handling that could result in injury. NOTE: The ESD Warning icon requires that you take electrostatic precautions when handling the device.
2 SD-WAN Edge 600 Series The Dell EMC SD-WAN Edge 600 Series (610, 620, 640, and 680) simplifies SD-WAN integration into your IT solution. It connects the service provider edge or small-to-medium branch locations to the cloud to host virtual network functions. The Edge 600 Series with 10/30/50/100/200/500 Mbps and 1/5/10 Gbps comes with VeloCloud software preinstalled. • • • Dell EMC SD-WAN Edge—a hardware device with VeloCloud/VMware software preinstalled.
3. Reset button 5. Two 1 GbE GE1/GE2 default LAN connections 7. DC Power connection 4. SFP/SFP+ ports 6. Four 1 GbE GE3-6 or SFP1-2 default WAN connections The Edge 600 Series includes two USB 3.0 Type-A console ports on the right and left sides of the platform.
• • • • Red—there is no WAN connection. Yellow—the platform has an Internet connection but the device is either not activated or the VeloCloud service is not active. Green—one of the WAN ports detects a valid Internet connection. Blue—the platform is in standby mode. As the system functions are in process, the service indicator displays: • • • • White—initial power-on and boot is in progress. Flashing blue—system reset or software update is in progress.
Prerequisites The following is a list of components that are required for successful platform installation: NOTE: For detailed installation instructions, see Site preparations and Edge 600 Series installation.
3 Site preparations The Edge 600 Series platform connects the service provider edge or small-to-medium branch locations to the cloud, to host virtual network functions. Use the platform on a desktop or optionally install the platform in a wall or rack. NOTE: If you optionally install the platform into a rack or cabinet, install the platform first, and then install any additional components such as cables or optics.
Fans and airflow Fan installation is done at the factory. The Edge 600 Series supports forced airflow from the sides and back of the enclosure. • • • • Two-core—no fan Four-core—single fans Eight-core—two fans Sixteen-core—two fans Position the platform in a well-ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring. The platform never intentionally turns off the fans. NOTE: The Edge 600 Series fans are not field-replaceable.
4 Edge 600 Series installation To install the Edge 600 Series platform, complete the installation procedures in the order that is presented in this chapter. Always handle the platform and components with care. NOTE: For thermal considerations, do not stack the Edge 600 Series platforms on top of each other. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and components.
WARNING: When mounting the Edge 640 or Edge 680 platform to the wall, face the Ethernet ports up towards the ceiling and the system status LED panel down, facing the floor. NOTE: When driving the screws into the bracket and platform, verify that you torque to 5 lb-in. NOTE: When mounting the platform to the wall using the included wall mount brackets, you do not need to remove the rubber pads from the bottom of the platform.
Keyhole-shaped bracket installation 4. Using a torque screwdriver, attach the wall mount brackets to the platform using the four M3 screws included. 5. Anchor the screws into the wall surface. 6. Place the pre-installed platform brackets over the wall-mounted screws. Slide the platform to one side to secure the platform in place. WARNING: When mounting the Edge 640 or Edge 680 platform to the wall, face the Ethernet ports up towards the ceiling and the system status LED panel down, facing the floor.
NOTE: Ensure the platform is in a well-ventilated environment with clearance around the exhaust vents. 1. Place one or two Edge 600 Series platforms in the dual rackmount tray. 2. Use the eight included M3 screws to attach the platforms to the dual rackmount tray. Use four screws for each platform. 3. Install the rackmount tray in to your rack using the installation instructions included with the tray. Optics modules The Edge 610 and Edge 620 platforms have SFP ports.
Start up sequence When the platform powers up, the fans immediately come on at high speed. The fan speed slows as the platform continues to boot. Platform setup WARNING: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. Install the device in an area that meets the following safety requirements: • • • • Near a properly grounded AC power outlet. In a temperature-controlled room with a temperature range from 0°C to 40°C (32°F to 104°F).
4. Connect local devices such as computers and switches to the GE1 or GE2 ports, or through the Edge WiFi. • GE1 or GE2 After following these instructions, if you are still unable to activate the Edge, contact your Dell EMC sales representative.
5 User interface You can activate and troubleshoot basic functionality of the Edge 600 series by connecting your laptop or mobile device using one of the default LAN ports (GE1 or GE2) or through the Wi-Fi connection. For additional information about initial activation, activation steps, or how to troubleshoot basic functionality of the Dell EMC Edge 600 series of systems, see the Advanced Activation Guide for your system: System URL Dell EMC Edge 610 Advanced Activation Guide https://infohub.
6 Specifications This section lists the Edge 600 Series specifications. NOTE: For RoHS information, see Restricted Material Compliance. Topics: • • • • • Chassis physical design IEEE standards Safety standards and compliance agency certifications Agency compliance Product recycling and disposal Chassis physical design Table 4. Edge 600 Series specifications Feature Specification Size 8.1 in x 7.9 in x 2.0 in (W x D x H) 20.8 cm x 20.0 cm x 5.
Feature Specification 5% to 90% (RH), non-condensing short term (< 1% of operational hour per year) Storage relative humidity 5% to 90% (RH) Operating altitude Maximum: 10,000 feet (3,048 meters) No performance degradation up to 3,117 feet (950 meters) IEEE standards The Edge 600 Series complies with the following IEEE standards: • • • • 802.1ab—LLDP 802.1ax—Layer 2 802.1d, 802.1w, 802.1s, 802.1x—Mgmt/Security; 802.3x—Layer 2 802.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Caution: 1. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to cochannel mobile satellite systems; 2.
Brasil – Aviso da Anatel Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
Japan VCCI compliance for class A equipment Figure 4. Japan: VCCI compliance for class A equipment This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. NOTE: Use the AC power cords with Dell EMC equipment only.
Japanese BTE compliance certificate Korean certification of compliance Korean certification of compliance Figure 6. Korean package label Radio compliance certificate Korea (Korean warning statement is only required for devices contain 2400~2483 and/or 5725~5825 MHz radios) 해당 무선설비는 운용 중 전파혼신 가능성이 있음 Korean radio compliance certificate Mexican certification of compliance Mexican compliance. La operación de este equipo está sujeta a las siguientes dos condiciones: 1.
Certification pending. Product recycling and disposal You must recycle or discard this appliance according to applicable local and national regulations. Dell EMC encourages owners of information technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell EMC offers a variety of product return programs and services in several countries to assist equipment owners in recycling their IT products.
7 Dell EMC support The Dell EMC support site provides documents and tools to help you effectively use Dell EMC equipment and mitigate network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The Dell EMC support site provides integrated, secure access to these services. To access the Dell EMC support site, go to www.dell.com/support/.