Dell EMC Networking Virtual Edge Platform 1405 Series Getting Started Guide July 2021 Rev.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents Chapter 1: About this Guide...........................................................................................................4 Related documents............................................................................................................................................................. 4 Information symbols............................................................................................................................................................
1 About this Guide This guide provides site preparation recommendations, step-by-step procedures for rack and desk mounting, inserting modules, and connecting to a power source for the Dell EMC Networking Virtual Edge Platform (VEP) 1405 series of systems. CAUTION: To avoid electrostatic discharge (ESD) damage, wear grounding wrist straps when handling this equipment. WARNING: Only trained and qualified personnel can install this equipment. Read this guide before you install and power up this equipment.
Information symbols This book uses the following information symbols: NOTE: The Note icon signals important operational information. CAUTION: The Caution icon signals information about situations that could result in equipment damage or loss of data. NOTE: The Warning icon signals information about hardware handling that could result in injury. NOTE: The ESD Warning icon requires that you take electrostatic precautions when handling the device.
2 Site Preparations The Virtual Edge Platform 1405 series of systems, or VEP1405, are a universal customer premise equipment (uCPE) devices. The VEP1405 series connects the service provider edge or small to medium branch locations to the cloud, to host virtual network functions. For more information about VEP1405 series specifications, see the Chassis physical design section.
Wall mount installation The VEP1405 series includes the hardware that is required for wall mount installation. Using a torque screwdriver, affix the wall mount brackets to the VEP1405 series using the four M3 screws included. NOTE: When driving the screws into the bracket and VEP1405 series unit, verify that 5 lb-in is the achieved torque setting.
Figure 4. VEP1405 series wall mount, installation anchor, and screw dimensions NOTE: Before mounting the VEP1405 series to the wall, verify that the wall surface is strong enough to support a firm installation of the unit and can withstand the weight of the unit, power cable, and network cabling. Using the measurements provided in the following diagram, use the measurement in the red box to mark the distance between the two installation points: Figure 5.
Figure 6. VEP1405 series wall mount bracket installation - cross-shaped cutout Rack-mounted installation As an option, the VEP1405 series can be mounted to a dual rack mount tray. Purchased separately, you can install the VEP1405 series to the dual rack mount tray using a torque screwdriver and the eight M3 screws included. NOTE: When driving the screws into the bracket and VEP1405 series unit, verify that 5 lb-in is the achieved torque setting.
Fans and airflow Fan installation is done as part of the factory install and is based on the stock keeping unit (SKU) type. The VEP1405 series of systems support a DC fan unit with fan airflow starting from the bottom of the unit: ● Four core unit with single fan ● Eight core unit with two fans ● Sixteen core unit with two fans Position the unit in a well ventilated environment with clearance around the exhaust vents. The fan speed varies based on internal temperature monitoring.
3 VEP1405 Series Installation To install the VEP1405 series unit, complete the installation procedures in the order that is presented in this section. Always handle the platform and its components with care. NOTE: ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when handling the platform and its components. As with all electrical devices of this type, take all the necessary safety precautions to prevent injury when installing this platform.
4 Specifications This section lists the specifications for the VEP1405 series of systems. CAUTION: Operate the product at an ambient temperature between 0-40°C (32–104°F). WARNING: There is a danger of explosion if the lithium battery is incorrectly replaced. Replace only with the same or equivalent type of battery. Dispose of the battery according to the manufacturer's instructions. NOTE: For RoHS information, see https://www.dell.com/learn/tw/zh/twcorp1/envt-info-materials.
NOTE: For a listing of the supported optics guidelines for the VEP1405 series, see the Virtual Edge Platform 1405 Series Technology Guide. Figure 9. VEP1405 series front view 1. Security lock port 2. USB port NOTE: An additional USB port is located on the opposite side of the system. 3. System status indicator LED Table 3.
Figure 11. VEP1405 series back view (without port cover) 1. Micro USB serial console port 2. Reset button NOTE: See the Reset button behavior table below for more information. 3. 4. 5. 6. LED status indicators for SFP+ ports SFP+ ports Ethernet ports and LED status indicators Power connection port Table 4.
Table 6. Chassis physical design Parameter Configuration option 1 Configuration option 2 Height 5.2 cm (2.0 in) 5.2 cm (2.0 in) Width 20.8 cm (8.1 in) 20.8 cm (8.1 in) Depth 20.0 cm (7.9 in) 20.0 cm (7.9 in) Chassis weight with factoryinstalled components ● 4-core: 1.44 kg (3.17 lb) ● 8-core: 1.42 kg (3.13 lb) ● 16-core: 1.44 kg (3.17 lb) ● 8-core: 1.42 kg (3.13 lb) ● 16-core: 1.44 kg (3.17 lb) NOTE: Chassis weight does not include the weight of the power supply. Table 7.
● ● ● ● ● ● ● ● ○ Meets or exceeds Hi Pot and Ground Continuity testing per UL 60950-1. CSA 60950-1-03, 2nd Edition EN 60950-1, 2nd Edition EN 60825-1, 1st Edition EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification Requirements and User’s Guide EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems FDA Regulation 21CFR 1040.10 and 1040.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Caution: 1. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems; 2.
Figure 15. Brasil – Aviso da Anatel certificate European Union EMC directive conformance statement This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. Dell EMC cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of this product, including the fitting of non-Dell EMC option cards.
この場合には使用者が適切な対策を講ずるよう要求されることがあります。 This is Class A product based on the standard of the Voluntary Control Council For Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. WARNING: Use the AC power cables with Dell EMC equipment only. Do not use Dell EMC AC power cables with any unauthorized hardware.
Mexico certification of compliance La operación de este equipo está sujeta a las siguientes dos condiciones: 1. Es posible que este equipo o dispositivo no cause interferencia perjudicial y 2. Este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.
5 Support The support site provides documents and tools to help you effectively use your equipment and mitigate network outages. Through the support site you can obtain technical information, access software upgrades and patches, download available management software, and manage your open cases. The support site provides integrated, secure access to these services. To access the support site, go to https://www.dell.com/support/.