Dell Chassis Management Controller Version 5.
Release Notes Dell Chassis Management Controller The Dell Chassis Management Controller (CMC) is a hot-pluggable systems management hardware and software solution designed to provide the following functions for Dell PowerEdge M1000e chassis system: • Remote management capabilities • Power control • Cooling control Version Dell Chassis Management Controller 5.0 Release Date December 2014 Previous Version Dell Chassis Management Controller Version 4.
What is Supported? Supported Web Browsers CMC version 5.0 is supported on the following Web browsers: • Microsoft Internet Explorer 9 • Microsoft Internet Explorer 10 • Microsoft Internet Explorer 11 • Safari version 6.0 • Safari version 7.0 • Mozilla Firefox version 29 • Mozilla Firefox version 30 • Google Chrome version 33 • Google Chrome version 34 What’s New • Includes features released in CMC version 4.5.
Known Issues Issue 1: Description XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device Page and OS. Resolution Virtual reseat or Physical reseat of the server. Versions/Systems Affected All CMC versions including CMC 5.0 and PowerEdge servers with iDRAC7 or earlier. Issue 2: Description Io-Identity values are displayed partially in the cmc getmacaddress -c all for 8F6NV(Intel). Resolution None Versions/Systems Affected CMC 5.
Issue 5: Description CMC GUI displays alerting choices for PCI alerts, but CMC does not support PCI. Resolution None. Versions/Systems Affected CMC 5.0 Limitations Issue 1: Description While executing WSMAN commands continuously, WSMAN timeouts can occur occassionally, but get resolved quickly without CMC failover or reboots. Resolution None Versions/Systems Affected All CMC versions including CMC 5.0. Issue 2: Description The remote racadm testfeature command (racadm -r testfeature..
Versions/Systems Affected All CMC versions including CMC 5.0. Issue 4: Description When you add a member chassis to a chassis group using the Multi-Chassis Management feature, you cannot specify the group members with an IPv6 address. Resolution None Versions/Systems Affected All CMC versions including CMC 5.0. Issue 5: Description While running "racadm getactiveerrors" command, module ID for server errors is displayed as a slot number, for example 1,2,3, and so on.
Upgrading Dell PowerEdge M1000e I/O Aggregator I/O Aggregator must first be updated to version 8.3.17.4 before updating to version 9.2.0.0 or greater. Contacting Dell NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area.
Information in this document is subject to change without notice. © 2014 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell(TM), the DELL logo, PowerEdge(TM), PowerVault(TM), Compellent(TM) and OpenManage(TM) are trademarks of Dell Inc. Intel(R) is a registered trademark of Intel Corporation in the U.S. and other countries.