SNMP Reference Guide for iDRAC and Chassis Management Controller
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2017 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries.
Contents 1 Introduction..................................................................................................................... 5 Supported SNMP Versions.................................................................................................................................................5 Managed Object Used in This Document...........................................................................................................................
RAC Information Group.............................................................................................................................................. 48 Chassis Information Group......................................................................................................................................... 50 System Information Group......................................................................................................................................... 50 Status Group..
1 Introduction This reference guide provides information about Simple Network Management Protocol (SNMP) Management Information Base (MIB) which are released with the current version of Dell iDRAC and Chassis Management Controller. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects. All essential Simple Network Management Protocol (SNMP) terms are defined in this guide.
MIB Name Agent / Hardware Supported Purpose of the MIB rac_host.mib Remote access out-of-band agent Provides information about the components monitored by the remote access out-of-band software agent. DELL-RAC-MIB.txt Chassis Management Controller (CMC) Provides information about components monitored by the Chassis Management Controller for modular chassis. This MIB is the legacy iDRAC MIB. Changes made in this MIB are not for iDRAC.
Table 4. Dell RAC Out-of-Band MIB Topics MIB Group Number The Dell RAC Out-of-Band 2 MIB consists of information for the following groups: • • • • • • • Product Information Chassis Status Chassis Power CMC Power Information CMC PSU Information Chassis Alerts Legacy Alerting Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs.
a type and a value that uniquely identifies an object such as a chassis. The table defines all of the variables that comprise the managed object UUID. The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value. These objects comprise the Server Administrator definitions for the UUID. Table 5. UUID Table Name uUIDTable Object ID 1.3.6.1.4.
Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 10. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Read-only Other Documents You May Need In addition to this guide, you can access the following guides available on the Dell Support website at dell.com/support/manuals.
2 Chassis Management Controller Group Table 11. Chassis Management Controller Group Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes provide product information for the chassis management controller: Table 12. DRsProductName Name drsProductName Object ID 1.
Access Read-only Table 16. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 17. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis. Syntax DellString Access Read-only Table 18. DRsProductURL Name drsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Access Read-only Table 22. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 23. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only Table 24. DRsProductSystemSlot Name drsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Access Read-only Table 28. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis. Syntax DellString Access Read-only Table 29. DRsProductChassisRackSlot Name drsProductChassisRackSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.18 Description Defines the rack slot locator of the chassis. Syntax DellString Access Read-only Table 30. DRsProductChassisModel Name drsProductChassisModel Object ID 1.3.6.
Syntax INTEGER Access Read-only Table 34. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller 1. Syntax DellString Access Read-only Table 35. DRsiKVMFirmwareVersion Name drsiKVMFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.2 Description Defines the firmware version of the iKVM. Syntax DellString Access Read-only Table 36.
Table 39. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 40. DRsKVMCurrStatus Name drsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 41.
Access Read-only Table 45. DRsTempCurrStatus Name drsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 46. DRsCMCCurrStatus Name drsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 47.
Description Defines the previous chassis status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 51. DRsIOMPrevStatus Name drsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 52. DRsKVMPrevStatus Name drsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.
Table 56. DRsBladePrevStatus Name drsBladePrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.7 Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 57. DRsTempPrevStatus Name drsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 58.
Access Read-only Table 62. DRsRedChangeTime Name drsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 63. DRsPowerChangeTime Name drsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.5 Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 64.
Access Read-only Chassis Power The following MIB tables provide power information for the chassis being monitored by the chassis management controller. Table 68. DRsCMC Power Table Name drsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible Table 69. DRsCMC Power Table Entry Name drsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry.
Table 73. DRsPotentialPower Name drsPotentialPower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.2 Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only Table 74. DRsIdlePower Name drsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Access Read-only Table 79. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 80. DRsWattsPeakTime Name drsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9 Description Defines the timestamp of the most recent chassis peak power usage. Syntax DellTimestamp Access Read-only Table 81.
Syntax DellPowerReading Access Read-only Table 85. DRsAmpsReading Name drsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in watts). Syntax DellPowerReading Access Read-only CMC PSU Information The following MIB tables provide information on the chassis power supply units. Table 86. DRsPSUChassisIndex Name drsPSUChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.
Table 90. DRsPSUVoltsReading Name drsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5 Description Defines the instantaneous PSU voltage reading. Syntax DellPowerReading Access Read-only Table 91. DRsPSUAmpsReading Name drsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU current reading. Syntax DellPowerReading Access Read-only Table 92. DRsPSUWattsReading Name drsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.
Table 95. DRsServerIndex Name drsServerIndex Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.1 Description Defines the index (one-based) of the associated CMC server. Syntax DellCMCServerIndexRange Access Read-only Table 96. DRsServerMonitoringCapable Name drsServerMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.2 Description Defines the monitoring capabilities, or the absence of a server in this location. Syntax DellCMCServerCapable Access Read-only Table 97.
Description Defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server. Syntax DellString Access Read-only Table 101. DRsServerModel Name drsServerModel Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.7 Description This attribute defines the Model of the CMC server. Syntax DellString Access Read-only Table 102. DRsServerAssetTag Name drsServerAssetTag Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.
Access Read-only Table 106. DRsServerAssignedServerSlots Name drsServerAssignedServerSlots Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.12 Description This attribute defines the server slots to which a storage sled is assigned. If this is a storage sled that is assigned to one more or more server slots, the value will be a comma-separated list of one or more server slot names. If the storage sled is not assigned to a server slot, the value will be an empty string.
Table 111. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 112. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 Description Defines the message ID of the alert. Syntax DisplayString Access Read-only Table 113. DrsCA2Message Name drsCA2Message Object ID 1.3.6.1.4.1.674.10892.2.21.10.
Table 116. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 117. DRsAlertSystem Name drsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String Access Read-only Table 118.
Syntax DellStatus Access Read-only Table 122. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
3 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
NOTE: The PowerEdge M1000e CMC, PowerEdge VRTX CMC and PowerEdge FX2 CMC do not generate the traps in this section. They generate the traps documented in the CMC Traps. Table 123. RAC Traps TrapID Name Description Severity Category Cause Supported by RAC Platform 0 CodeStart SNMP agent is initializing itself Information Status RAC power on or reset. All 1 Authentication Failure Request Critical received with an invalid community name Error SNMP request with an invalid community name.
TrapID Name Description Severity Category Cause Supported by RAC Platform with Severity: Normal BMC Traps The BMC monitors the system for critical events by communicating with various sensors on the system board and by sending alerts and log events when certain parameters exceed their preset thresholds. All the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.3183.1.1.1. Table 124.
TrapID Description Severity 131465 Over-Voltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Cleared Information 356096 Chassis Intrusion - Physical Security Violation Critical 356224 Chassis Intrusion (Physical Security Violation) Event Cleared Information 262400 Generic Predictive Fan Failure (predictive failure asserted) Minor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical F
TrapID Description Severity 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cleared Information 552707 Power Supply AC Lost Critical 552835 P
Table 125. PowerEdge M1000e CMC traps TrapID Name Description Severity Category 2000 alertCMCTestTrap CMC has generated a test trap. Informational Error Events 2002 alertCMCNormalTrap CMC reported a return-tonormal or informational event. Error Events 2003 alertCMCWarningTrap CMC reported a warning event. Warning Error Events 2004 alertCMCCriticalTrap CMC reported a critical event. Critical Error Events 2005 alertCMCNonRecoverable Trap CMC reported a catastrophic event.
TrapID Description Category SubCategory Severity 2225 Battery has failed or battery is absent. Error Events Battery Critical Description Category SubCategory Severity Cable failure. Error Events Cable Critical Description Category SubCategory Severity Chassis Management Controller detected a warning. Status Events CMC Minor Chassis Management Controller detected an error. Error Events CMC Critical Description Category SubCategory Severity Fan information.
Table 132. IO Virtualization Traps TrapID Description Category SubCategory Severity IO Virtualization information. Status Events IO Virtualization Informational IO Virtualization warning. Status Events IO Virtualization Minor IO Virtualization failure or critical event. Error Events IO Virtualization Critical Description Category SubCategory Severity Link status information. Status Events Link Status Informational Link status warning.
Table 136. Power Supply Absent Trap TrapID Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Description Category SubCategory Severity Power usage information. Status Events Power Usage Informational Power usage warning. Status Events Power Usage Minor Power usage failure. Error Events Power Usage Critical Description Category SubCategory Severity Redundancy information.
TrapID Description Category SubCategory Severity 2377 System Event Log failure or critical event. Error Events System Event Log Critical Category SubCategory Severity Status Events Software Configuration Informational Status Events Software Configuration Minor Error Events Software Configuration Critical Description Category SubCategory Severity Temperature sensor value is within range. Status Events Temperature Informational Temperature sensor has detected a warning value.
Table 144. Storage Battery Traps TrapID Description Category Subcategory Severity Storage battery information. Error Events Battery Informational Storage battery warning. Error Events Battery Minor Storage battery failure. Error Events Battery Critical Description Category Subcategory Severity Storage controller information. Error Events Controller Informational Storage controller warning. Error Events Controller Minor Storage controller failure.
Table 148. Storage Physical Disk Traps TrapID Description Category Subcategory Severity Storage physical disk information. Error Events Physical Disk Informational Storage physical disk warning. Error Events Physical Disk Minor Storage physical disk failure. Error Events Physical Disk Critical alert2StoragePhysicalDiskInformation 4347 alert2StoragePhysicalDiskWarning 4346 alert2StoragePhysicalDiskFailure 4345 Table 149.
TrapID Description Category Subcategory Severity 4177 Storage Management has detected a device independent error condition. There is no global status change associated with this trap. Error Events Storage Management Critical Category Subcategory Severity Error Events Temperature Probe Informational Table 152. Storage Temperature Probe Traps TrapID Description alert2StorageTemperatureProbeInformation 4211 Storage temperature probe information.
Table 155. Audit IO Virtualization Traps TrapID Description Category SubCategory Severity IO Virtualization audit warning. Status Events IO Virtualization Minor Description Category SubCategory Severity License information. Status Events License Informational License warning. Status Events License Minor License failure. Error Events License Critical Description Category SubCategory Severity PCI device audit warning.
Table 160. Audit Software Change Traps TrapID Description Category SubCategory Severity Error Events Software Change Critical Category SubCategory Severity IO virtualization configuration information. Status Events IO Virtualization Informational IO Virtualization configuration warning. Status Events IO Virtualization Minor Category SubCategory Severity Status Events PCI Device Informational Description Category SubCategory Severity Software configuration warning.
Table 165. Software Change Traps TrapID Description Category Subcategory Severity Status Events Software Change Minor alert2SoftwareChangeUpdateWarning 6314 46 Software change update warning.
4 iDRAC MIB The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 and 8 (iDRAC7 and iDRAC8). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 and iDRAC8 of a system. NOTE: From iDRAC7 firmware release r1.30.
NOTE: iDRAC7 firmware release r1.30.30 or later and iDRAC8 supports SNMP query operations (GET, GETNEXT, GETBULK) through the SNMPv3 protocol. In addition to supporting query operations through the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported. iDRAC SNMP Data Security Features iDRAC firmware supports the following data security features: • SNMP security lockout feature – iDRAC supports a simply, non-configurable SNMP security lockout feature.
Access Read-only Table 169. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card. Syntax StringType Access Read-only Table 170. RAC Manufacturer Name racManufacturer Object ID 1.3.6.1.4.1.674.10892.5.1.1.4.0 Description This attribute defines the product manufacturer of a remote access card. Syntax StringType Access Read-only Table 171.
Access Read-only Chassis Information Group The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group. Table 175. Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.
Syntax StringType Access Read-only Table 180. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 181. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system. Syntax StringType Access Read-only Table 182.
Syntax StringType Access Read-only Table 186. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 187. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.10892.5.1.3.10.0 Description This attribute defines the Rack locator of the system. Syntax StringType Access Read-only Table 188.
Syntax StringType Access Read-only Table 192. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.0 Description This attribute defines the Room locator of the system. Syntax StringType Access Read-only Table 193. System Chassis System Height Name systemChassisSystemHeight Object ID 1.3.6.1.4.1.674.10892.5.1.3.16.0 Description This attribute defines the height of the system, in 'U's.
Table 197. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 198. System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.0 Description This attribute defines the system status as it is reflected by the LCD front panel.
Storage Details Group The Storage Details Group contains tables that provide detailed information about the external storage subsystem of the system in which iDRAC resides. Battery Table The objects provide information about the Battery storage group. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.
6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 205. Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.10 Description This entry is obsolete. Use the battery Component Status or battery State instead. Syntax INTEGER Access read-only Table 206. Battery FQDD Name batteryFQDD Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.15.1.
Description The controller's name as represented in Storage Management. Syntax DisplayString Access read-only Table 210. Controller Rebuild Rate Name controllerRebuildRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.7 Description The rebuild rate is the percentage of the controller's resources dedicated to rebuilding a failed disk when a rebuild is necessary. Syntax INTEGER Access read-only Table 211. Controller FW Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10892.5.
Description The status of the controller itself without the propagation of any contained component status. Possible values: 1. Other 2. Unknown 3. OK 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 215. Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.41 Description Currently installed driver version for this controller on the host. Syntax DisplayString Access read-only Table 216.
Table 219. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.50 Description The background initialization (BGI) rate is the percentage of the controller's resources dedicated to performing the background initialization of a redundant virtual disk after it is created. Syntax INTEGER Access read-only Table 220. Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.
Description Indicates whether hot spare drives would be restored on insertion into the same slot. Syntax BooleanType Access read-only Table 224. Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.60 Description Indicates whether un-configured drives would be put in power save mode by the controller. Syntax BooleanType Access read-only Table 225.
Syntax INTEGER Access read-only Table 229. Controller Copy Back Mode Name controllerCopyBackMode Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.71 Description The current copy back mode setting for the controller. Possible values: 1. Not one of the following. 2. Not supported on this controller. 3. Disks assigned as spares could revert back to spare status. 4.
Access read-only Table 233. Controller Load Balance Setting Name controllerLoadBalanceSetting Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.75 Description The ability of the controller to automatically use both controller ports (or connectors) connected to the same enclosure in order to route I/O requests. Possible values: 1. Not one of the following. 2. Not supported. 3. Automatic load balancing is active. 4. Load balancing is inactive. Syntax INTEGER Access read-only Table 234.
Table 237. Controller Display Name Name controllerDisplayName Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.79 Description The controller's friendly FQDD as represented in Storage Management. Syntax DisplayString Access read-only Table 238. Controller T10 PI Capability Name controllerT10PICapability Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.80 Description Description Indicates whether the controller supports the T10 PI (Protection Information).
Syntax BooleanType Access read-only Table 242. Controller Boot Mode Name controllerBootMode Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.1.1.84 Description Indicates the boot mode of the controller. Possible values: 1. Not applicable for this controller. 2. User mode: User interaction required for all boot messages (not applicable for uEFI environments). 3. Continue Boot On Error. User interaction only required for critical messages. 4. Headless Mode Continue On Error.
NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892.2.6.1.20.130.4.1.1. Table 245. Physical Disk Number Name physicalDiskNumber Object ID 1.3.6.1.4.1.
Table 249. Physical Disk Product ID Name physicalDiskProductID Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.6 Description The model number of the physical disk. Syntax DisplayString Access read-only Table 250. Physical Disk Serial No Name physicalDiskSerialNo Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.7 Description The physical disk's unique identification number from the manufacturer. Syntax DisplayString Access read-only Table 251.
Access read-only Table 255. Physical Disk Bus Type Name physicalDiskBusType Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.21 Description The bus type of the physical disk. Possible values: 1. The bus type could not be determined. 2. Small Computer System Interface (SCSI). 3. Serial Attached SCSI (SAS). 4. Serial Advanced Technology Attachment (SATA). 5. Fibre channel. 6. PCIe. Syntax INTEGER Access read-only Table 256.
Description The part number of the disk. Syntax DisplayString Access read-only Table 259. Physical Disk SAS Address Name physicalDiskSASAddress Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.28 Description The SAS address of the physical disk. Syntax DisplayString Access read-only Table 260. Physical Disk Negotiated Speed Name physicalDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 262. Physical Disk Smart Alert Indication Name physicalDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.31 Description Indicates whether the physical disk has received a predictive failure alert. Syntax BooleanType Access read-only Table 263. Physical Disk Manufacture Day Name physicalDiskManufactureDay Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.32 Description The day of the week on which the physical disk was manufactured.
Description This property is applicable to SSD media type only. This indicates the wear-out percentage of the SSD. Typically it is a value between 0 to 100. However, if the value is not available or not applicable (in the case of HDD media type) the value will be 255. Syntax INTEGER Access read-only Table 268. Physical Disk Power State Name physicalDiskPowerState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.49 Description The power state of the physical disk. Possible Values: 1.
Table 271. Physical Disk Security Status Name physicalDiskSecurityStatus Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.52 Description The security/encryption status of the physical disk. Possible Values: 1. The physical disk supports encryption. 2. The physical disk does not support encryption 3. The physical disk is encrypted. 4. The physical disk is locked by a key. 5. The physical disk is locked by a foreign key. Syntax INTEGER Access read-only Table 272.
Description Indicates whether the physical disk supports the T10 PI (Protection Information). These protection fields are known as DIF (Data Integrity Fields). Possible values: 1. Not one of the following. 2. Capable of supporting T10 PI. 3. Not capable of supporting T10 PI. Syntax INTEGER Access read-only Table 276. Physical Disk Block Size In Bytes Name physicalDiskBlockSizeInBytes Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
Table 280. Physical Disk Current Active Controller Name physicalDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.62 Description Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. Syntax FQDDString Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 281. Physical Disk Failover Controller Name physicalDiskFailoverController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.130.4.1.
2. The virtual disk is operating normally or optimally. 3. The virtual disk has encountered a failure. The data on disk is lost or is about to be lost. 4. The virtual disk encountered a failure with one or all of the constituent redundant physical disks. The data on the virtual disk might no longer be fault tolerant. Syntax INTEGER Access read-only Table 285. Virtual Disk Size In MB Name virtualDiskSizeInMB Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
1. Not one of the following 2. RAID-0 3. RAID-1 4. RAID-5 5. RAID-6 6. RAID-10 7. RAID-50 8. RAID-60 9. Concatenated RAID 1 10. Concatenated RAID 5 Syntax INTEGER Access read-only Table 289. Virtual Disk Stripe Size Name virtualDiskStripeSize Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.14 Description The stripe size of this virtual disk. Possible values: 1. Not one of the following 2. Default 3. 512 bytes 4. 1 kB 5. 2 kB 6. 4 kB 7. 8 kB 8. 16 kB 9.
2. Unknown 3. OK 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 291. Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.23 Description Indicates whether the virtual disk has bad blocks. Syntax BooleanType Access read-only Table 292. Virtual Disk Secured Name virtualDiskSecured Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 295. Virtual Disk Operational State Name virtualDiskOperationalState Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.30 Description The state of the virtual disk when there are progressive operations ongoing. Possible values: 1. There is no active operation running. 2. The virtual disk configuration has changed. The physical disks included in the virtual disk are being modified to support the new configuration. 3. A Consistency Check (CC) is being performed on the virtual disk. 4.
Access read-only Table 300. Virtual Disk FQDD Name virtualDiskFQDD Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.35 Description The virtual disk's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 301. Virtual Disk Display Name Name virtualDiskDisplayName Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.36 Description The virtual disk's friendly FQDD as represented in Storage Management.
1. No Access. 2. Full Access. Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 305. Virtual Disk Adapter 2 Access Policy Name virtualDiskAdapter2AccessPolicy Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.40 Description Indicates the Access policy of the virtual disk with the virtual adapters. Possible values: 1. No Access. 2. Full Access. Syntax INTEGER Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 306.
Table 308. Virtual Disk Current Active Controller Name virtualDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.43 Description Indicates the Fully Qualified Device Descriptor (FQDD) of the current active controller. Syntax FQDDString Access read-only NOTE: This attribute is applicable for VRTX CMC only. Table 309. Virtual Disk Current Active Controller Name virtualDiskCurrentActiveController Object ID 1.3.6.1.4.1.674.10892.5.5.1.20.140.1.1.
Table 312. Enclosure Name Name enclosureName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.2 Description The enclosure/backplane's name as represented in Storage Management. Syntax DisplayString Access read-only Table 313. Enclosure State Name enclosureState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.4 Description The current state of this enclosure/backplane. Possible states: 1. The current state could not be determined. 2. The enclosure is operating normally. 3.
Syntax DisplayString Access read-only Table 317. Enclosure Roll Up Status Name enclosureRollUpStatus Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.23 Description Severity of the enclosure/backplane state. This is the combined status of the enclosure and its sub-components. Possible values: 1. Other 2. Unknown 3. OK 4. Non-critical 5. Critical 6. Non-recoverable Syntax ObjectStatusEnum Access read-only Table 318.
Syntax INTEGER Access read-only Table 322. Enclosure Fan Count Name enclosureFanCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.40 Description The number of fans present in the storage enclosure. Syntax DisplayString Access read-only Table 323. Enclosure PSU Count Name enclosurePSUCount Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.41 Description The number of Power Supply Units (PSU) present in the storage enclosure. Syntax DisplayString Access read-only Table 324.
Description The position of the storage enclosure within a daisy chain. Syntax DisplayString Access read-only Table 328. Enclosure Backplane Bay ID Name enclosureBackplaneBayID Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.46 Description The unique bay ID of the backplane. Syntax DisplayString Access read-only Table 329. Enclosure FQDD Name enclosureFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.3.1.
NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.1 for the table group are attributes for checking on iDRAC. To check the corresponding set of attributes for VRTX CMC systems, use the Object ID example: 1.3.6.1.4.1.674.10892.2.6.1.20.130.13.1.1. Table 332.
Description Firmware version of the enclosure management module. Syntax DisplayString Access read-only Table 337. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.13.1.11 Description The status of the enclosure management module itself without the propagation of any contained component status. Possible values: 1. Other 2. Unknown 3. OK 4. Non-critical 5. Critical 6.
Description Instance number of this fan. Syntax INTEGER Access read-only Table 341. Enclosure Fan Name Name enclosureFanName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.2 Description The fan's name as represented in Storage Management. Syntax DisplayString Access read-only Table 342. Enclosure Fan State Name enclosureFanState Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.3 Description The current state of this fan. Possible states: 1.
Syntax ObjectStatusEnum Access read-only Table 345. Enclosure Fan FQDD Name enclosureFanFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.20 Description The fan's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 346. Enclosure Fan Display Name Name enclosureFanDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.7.1.21 Description The fan's friendly FQDD as represented in Storage Management.
2. The power supply unit is operating normally 3. The power supply unit has encountered a hardware problem or is not responding 4. The power supply unit is no longer connected to the enclosure or there exists a problem communicating to it 5. The power supply unit is unstable Syntax INTEGER Access read-only Table 350. Enclosure Power Supply Part Number Name enclosurePowerSupplyPartNumber Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.9.1.7 Description The part number of the power supply unit.
Access read-only Enclosure Temperature Probe Table The objects provide information about the Enclosure Temperature Probe Table group in storage. NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same Storage attributes with some modification in CMC. The Object ID mentioned example: 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1 for the table group are attributes for checking on iDRAC.
Syntax INTEGER Access read-only Table 358. Enclosure Temperature Probe Min Critical Value Name enclosureTemperatureProbeMinCriticalValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.8 Description The maximum temperature that will force the probe into a warning state. Syntax INTEGER Access read-only Table 359. Enclosure Temperature Probe Max Warning Value Name enclosureTemperatureProbeMaxWarningValue Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.
Syntax ObjectStatusEnum Access read-only Table 363. Enclosure Temperature Probe FQDD Name enclosureTemperatureProbeFQDD Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.15 Description The temperature probe's Fully Qualified Device Descriptor (FQDD) as represented in Storage Management. Syntax FQDDString Access read-only Table 364. Enclosure Temperature Probe Display Name Name enclosureTemperatureProbeDisplayName Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.
Trap Variables This section lists the six variables that are sent with iDRAC traps to provide additional information about a trap or alert generated by some event on the system. The trap variables presented here apply to all iDRAC7 and iDRAC8 traps. The trap variables are sent in the order listed and are reserved for use only in traps. Table 365. Alert Message ID Variable Name alertMessageID Object ID 1.3.6.1.4.1.674.10892.5.3.1.1.0 Description Message ID of the event.
Table 371. Alert Device Display Name Variable Name alertDeviceDisplayName Object ID 1.3.6.1.4.1.674.10892.5.3.1.7.0 Description Display name of the device/FQDD Syntax DisplayString Table 372. Alert Message Arguments Variable Name alertMessageArguments Object ID 1.3.6.1.4.1.674.10892.5.3.1.8.0 Description Concatenated set of strings representing the message arguments of the event.
TrapID Description Category SubCategory Severity Current sensor has detected a warning value. System Health Amperage Minor Current sensor has detected a failure value. System Health Amperage Critical Description Category SubCategory Severity Automatic system recovery (ASR) was performed. System Health Auto Sys Reset Critical Description Category SubCategory Severity Battery state has returned to normal; or battery presence had been detected.
Table 381. Processor Device Status Traps TrapID Description Category SubCategory Severity Processor device status has returned to normal. System Health Processor Informational Processor device status has detected a warning. System Health Processor Minor Processor device status has detected a failure. System Health Processor Critical Description Category SubCategory Severity Processor device is absent.
TrapID Description Category SubCategory Severity Hardware configuration warning. System Health Hardware Config Minor Hardware configuration failure or critical event. System Health Hardware Config Critical Description Category SubCategory Severity IO Virtualization failure or critical event. System Health IO Virtualization Critical Description Category SubCategory Severity Link status information. System Health Link Status Informational Link status warning.
Table 390. Operation System ("OS") Event Traps TrapID Description Category SubCategory Severity An OS graceful stop occurred; or an System Health OS graceful shut-down occurred. OS Event Informational A critical stop occurred during OS load; or a runtime critical stop occurred. System Health OS Event Critical Description Category SubCategory Severity An informational event was detected for a PCI device.
TrapID Description Category SubCategory Severity Power supply has detected a warning. System Health Power Supply Minor Power supply has detected a failure. System Health Power Supply Critical Power Supply Warning 2186 Power Supply Failure 2185 Table 395. Power Supply Absent Trap TrapID Description Category SubCategory Severity Power supply is absent. System Health PSU Absent Critical Description Category SubCategory Severity System performance restored.
TrapID Description Category SubCategory Severity System Health IDSDM Media Critical Category SubCategory Severity System Health IDSDM Absent Critical Category SubCategory Severity System Health IDSDM Redundancy Informational System Health IDSDM Redundancy Minor Integrated Dual SD Module redundancy is lost. System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security warning.
Table 403. Software Configuration Traps TrapID Description Category SubCategory Severity Software Configuration information. System Health Software Config Informational Software Configuration warning. System Health Software Config Minor Software Configuration failure or critical event. System Health Software Config Critical Description Category SubCategory Severity Temperature sensor value is within range.
TrapID Description Category SubCategory Severity 2505 vFlash Media device failure. System Health vFlash Event Critical Description Category SubCategory Severity vFlash Media device is absent. System Health vFlash Absent Informational Description Category SubCategory Severity RAC information. System Health RAC Informational Description Category SubCategory Severity Voltage sensor reading is within range.
TrapID Description Category SubCategory Severity 4273 Battery has failed or battery is absent. Storage Battery Event Critical Description Category SubCategory Severity Controller information. Storage Storage Contr Informational Controller warning. Storage Storage Contr Minor Controller failure. Storage Storage Contr Critical Description Category SubCategory Severity Enclosure information. Storage Storage Enclosr Informational Enclosure warning.
Table 416. Power Supply Traps TrapID Description Category SubCategory Severity Power supply information. Storage Power Supply Informational Power supply warning. Storage Power Supply Minor Power supply failure. Storage Power Supply Critical Description Category SubCategory Severity Security event information. Storage Security Event Informational Security event warning. Storage Security Event Minor Security event failure or critical event.
Table 420. Virtual Disk Trap TrapID Description Category SubCategory Severity Virtual disk information. Storage Virtual Disk Informational Virtual disk warning. Storage Virtual Disk Minor Virtual disk failure. Storage Virtual Disk Critical Storage VirtualDisk Information 4355 Storage Virtual Disk Warning 4354 Storage Virtual Disk Failure 4353 Updates Trap Group The Updates Trap Group contains traps that fall under the Updates event category of iDRAC.
TrapID Description Category SubCategory Severity 8594 Debug authorization failed. Audit Debug Minor Description Category SubCategory Severity User tracking warning. Audit User Tracking Minor Description Category SubCategory Severity iDRAC IP address has changed. Audit DRAC IP Address Informational Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure.
TrapID Description Category SubCategory Severity 8417 Power usage audit failure or critical event. Audit Power Usage Critical Category SubCategory Severity System Info Informational Table 431. System Power State Change Trap TrapID Description System Power State Change Information 8579 Host is going through a power state Audit change (powering on or powering off).
Table 437. Security Event Traps TrapID Description Category SubCategory Severity Configuration Security Event Minor Description Category SubCategory Severity Software configuration warning. Configuration Software Config Minor Software configuration failure. Configuration Software Config Critical Description Category SubCategory Severity The iDRAC generated a test trap event in response to a user request.