Dell Chassis Management Controller Version 1.
Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2015 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction......................................................................................................... 11 Supported RACADM Interfaces........................................................................................................... 11 RACADM Syntax Usage.................................................................................................................. 11 SSH or Telnet RACADM.....................................................................................
getled...................................................................................................................................................40 getmacaddress.................................................................................................................................... 41 getmodinfo..........................................................................................................................................46 getniccfg...............................................
sslkeyupload........................................................................................................................................ 85 sslcertupload....................................................................................................................................... 85 sslcertview...........................................................................................................................................86 sslcsrgen..............................................
cfgEmailAlert..................................................................................................................................... 103 cfgEmailAlertIndex (Read Only)..................................................................................................104 cfgEmailAlertEnable (Read/Write).............................................................................................. 104 cfgEmailAlertAddress (Read/Write).................................................................
cfgRacTuneTimezoneOffset ...................................................................................................... 113 cfgRacTuneSledNetworkUplink.................................................................................................. 114 cfgRacTuneUserBlkEnable.......................................................................................................... 114 cfgRacTuneWebserverEnable (Read/Write)..............................................................................
cfgADGlobalCatalog1 (Read/Write).............................................................................................121 cfgADGlobalCatalog2 (Read/Write)............................................................................................ 122 cfgADGlobalCatalog3 (Read/Write)............................................................................................ 122 cfgADType (Read/Write).......................................................................................................
cfgChassisPeakPowerTimestamp (Read Only)........................................................................... 131 cfgChassisMinPower (Read Only)............................................................................................... 131 cfgChassisMinPowerTimestamp (Read Only)............................................................................ 132 cfgChassisPowerStatus (Read Only)...........................................................................................
cfgNicCurrentVlanEnable (Read Only)........................................................................................141 cfgNicCurrentVlanID (Read Only)............................................................................................... 141 cfgNicCurrentVlanPriority (Read Only)....................................................................................... 141 cfgDNSCurrentServer1.........................................................................................................
Introduction 1 This document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups and object definitions of CMC for PowerEdge FX2/FX2s. NOTE: The terms “storage sled” and “storage module” are used interchangeably in this document. Supported RACADM Interfaces The RACADM command-line utility provides a scriptable interface that allows you to remotely configure your Remote Access Controller (RAC).
Example racadm -r -u -p getconfig -g idracinfo racadm -r -u -p getsysinfo RACADM Command Options The following table lists the options for the RACADM command. Option Description -r Specifies the controller’s remote IP address. -u Specifies the user name that is used to authenticate the command transaction. If the -u option is used, the -p option must be used, and the -i option (interactive) is not allowed.
Supported RACADM Subcommands The following table provides the list of RACADM subcommands and their corresponding interface support. For more information about the RACADM sub-commands including syntax and valid entries, see RACADM Subcommand Details.
Subcommand CMC getpciecfg Yes Yes getpminfo Yes Yes getraclog Yes Yes getractime Yes Yes getredundancymode No No getsel Yes Yes getsleduplinkstatus Yes Yes getsensorinfo Yes Yes getslotname Yes Yes getssninfo Yes Yes getsvctag Yes Yes getsysinfo Yes Yes getversion Yes Yes help and help Yes Yes ifconfig Yes Yes jobqueue Yes Yes krbkeytabupload No Yes license No Yes netstat Yes Yes ping Yes Yes ping6 Yes Yes racdump Yes Yes racre
Subcommand CMC setractime Yes Yes setslotname Yes Yes setsysinfo Yes Yes sshpkauth Yes Yes sslkeyupload No Yes sslcertview Yes Yes sslcsrgen Yes Yes sslresetcfg Yes Yes testemail Yes Yes testfeature Yes Yes testtrap Yes Yes traceroute Yes Yes traceroute6 Yes Yes Other Documents You May Need To access the documents from the Dell Support site. Along with this Reference Guide, you can access the following guides available at dell.com/support/manuals.
• The server module's Owner's Manual provides information about the server module's features and describes how to troubleshoot the server module and install or replace the server module's components. This document is available online at dell.com/poweredgemanuals. • The rack documentation included with your rack solution describes how to install your system into a rack, if required. • For the full name of an abbreviation or acronym used in this document, see the Glossary at dell.com/ support/manuals.
RACADM Subcommand Details 2 This section provides detailed descriptions about the RACADM subcommands, including the syntax and valid entries.
• ` (back quotation marks) • \ (backslash) For example, use the following for a string that contains the special characters, $, ",',`and \. For single quotation marks: • No character escaping is necessary. • A single quotation mark cannot be used even with a backslash escaped. NOTE: An empty string may be specified as either "" (using double quotation marks) or '' (using single quotation mark).
testtrap traceroute traceroute6 -- test CMC SNMP trap notifications -- determine the route of a packet -- determine the route of a packet Example for RACADM ? racadm ? getsysinfo getsysinfo -- display general CMC and system information Usage: racadm getsysinfo [-d] [-c] [-A] [-4] [-6] ----------------------------------------------------------Valid Options: -d : show CMC information -c : show chassis information -A : do not show headers or labels -4 : show CMC IPv4 information -6 : show CMC IP
NOTE: It is recommended that you use Firmware RACADM to run this subcommand. Synopsis racadm chassislog view -i -c -s -q -n -r -e Input • • • • • • • -i — Displays the number of records present in the active log. You cannot use this option with any other option. -c — The log type to filter the records. Provide multiple categories using a "," as the delimiter. The value is case-insensitive.
chassislog export Description Exports the Chassis log to a remote share. To export the chassis log, you must have the Clear Logs Administrator privilege.
chassisaction Description Executes a power action on the chassis or a server. To use this subcommand, you must have the Chassis Control Administrator privilege. Synopsis racadm chassisaction [-m ] Input • -m — Module on which you want to carry out the action. Values are: – chassis - this is the default value, if -m is not specified. – switch-n, where n=1 to 2 • — Action that you want to execute on the specified module.
– Remote RACADM: -u option or -i option Output None Example • • • racadm closessn -i 1234 Closes the session 1234. racadm closessn –u root Closes all the sessions for root user. racadm closessn –a Closes all the sessions. clrsel Description Deletes all existing records from the System Event Log (SEL). To use this subcommand, you must have the Clear Logs privilege.
• Output indexes a particular group supports. If -i < index > is not specified, a value of 1 is assumed for groups, which are tables that have multiple entries. The index is specified by the index value, not a named value. -c — The -c, or check option, is used with the config subcommand and allows the user to parse the .cfg file to locate syntax errors. If issues are found, the line number and a short description about the issue is displayed. This option is a check-only.
To use this subcommand, you must have the Server Administrator privilege. NOTE: You can also use setniccfg to configure static IP address, subnet mask, gateway, DHCP, speed, and duplex properties. Synopsis Input • • racadm deploy -m -u root -p -s -b -o racadm deploy -m -u root -p -s -6 -b -o where is a number between 0 and 128.
NOTE: This input is available in IOA only. • • -q— Displays or modifies the quick deploy parameters. -n— Specifies the number of reserved IP addresses for quick deploy. The valid values are 2 and 4. Output None Example • • • racadm deploy -m server-8 -s 192.168.0.20 255.255.255.0 192.168.0.1 The server was deployed successfully. The deploy command generates an error when used on the extension slot of a multi-slot server. racadm deploy -m server-9 192.168.0.11 255.255.255.0 192.168.0.
• Input cmc.alert.audit • cmc.alert.audit.lic • cmc.alert.audit.warning • cmc.alert.audit.lic.critical • • get - Displays the list of event filter settings. set - Configures the actions and notifications for a given event filter configuration. -c - Alert descriptor of the specific event filter. -n - The notification to be sent when the event occurs. Valid values are all, snmp, ipmi, email, or none. You can append multiple notifications separated by a comma.
• Configure the event generation interval and notifications for temperature statistics: racadm eventfilters set -c cmc.alert.system.tmps -r 5 n snmp fanoffset Description Configures the internal fans to run at a higher speed than the normal speed. To use this subcommand, you must have the Chassis Configuration Administrator privilege. Synopsis racadm fanoffset [-s Valid category values are: • off • low • medium • high Input s — Sets the fan speed.
Input • racadm feature -r -c ExtendedStorage • • -s — Displays the status of active features. -d — Deactivates the feature specified in -c option. NOTE: When the FlexAddress and FlexAddressPlus features are active, deactivating one of them results in deactivation of the other feature also. However, ExtendedStorage is not affected by the deactivation of FlexAddress or FlexAddresPlus. • -r — Repair damaged/unformatted ExtendedStorage media.
• • Update the firmware from the local file system using remote RACADM. The subcommand updates one or more devices of a single type at a time. To use this subcommand, you must have the Chassis Configuration Administrator privilege. NOTE: Running the subcommand to update the CMC firmware resets the CMC, causing all network connections to get logged off. NOTE: The subcommand generates an error, when used on the extension slot of a multi-slot server.
• • • • • • • -f — The FTP is used to download the firmware. -g — For CMC, the firmware is downloaded using the TFTP server. -u — The firmware update operation is performed. -a — Specifies the TFTP server IP address or FQDN used for the firmware image (used with -g). NOTE: CMC accepts IPv4, IPv6, or fully qualified domain names (FQDN) for both FTP and TFTP servers. -d — Specifies the source path where the firmware image is stored.
• Signed CMC Firmware Image: racadm fwupdate –g –u –a -d m Firmware update has been initiated. This update process may take Several minutes to complete. racadm fwupdate –s –m cmc-active Invalid firmware: The uploaded firmware image does not contain A verification signature. The following table describes the firmware update methods supported for each interface.
To run this subcommand, you must have the CMC Login User privilege.
Example racadm getchassisname CMC-1 getconfig Description Retrieves CMC configuration parameters individually, or all CMC configuration groups may be retrieved and saved to a file.
• • Output -u — The -u , or user name option, can be used to display the configuration for the specified user. The option is the login name for the user. -v — The -v option displays additional details with the display of the properties and is used with the -g option.
Input -n — Displays the model names for the daughter cards in servers. Example The following example is for a system with multi-slot servers.
A1 Link Status A2 Link Status Sled No : 3 Port No A1 Link Status A2 Link Status Port No A1 Link Status A2 Link Status = Up = Up = 5 = Up = Down = 4 = Up = Up getflexaddr Description Displays enabled or disabled status for the entire chassis. If used with -i, the command displays MACs/WWN on a per-slot–basis.
2 Enabled Present 3a Disabled Present 3b Disabled Present 3c Disabled Present 3d Disabled Present 4 Disabled Present idrac System Disabled Display the current FlexAddress setting for slot 1.
slot1 A2 10 GbE KR 10:00:00:90:FA: 51:31:E5 20:01:F0:1F:AF:88:22:75(active) 10 GbE KR 00:90:FA: 51:31:E7 F0:1F:AF:88:22:77(active) 10 GbE KR 00:90:FA: 51:31:E7 F0:1F:AF:88:22:7B(active) 10 GbE KR 00:90:FA: 51:31:E9 F0:1F:AF:88:22:7D(active) 10 GbE KR 00:90:FA: 51:31:EA F0:1F:AF:88:21:A2(active) 10 GbE KR 00:90:FA:51:31:EB F0:1F:AF:88:21:A4(active) 10 GbE KR/ 3 00:90:FA: 51:31:EB F0:1F:AF:88:21:A4(active) FCoEWWN 10:00:00:90:FA: 51:31:EB 20:01:F0:1F:AF:88:21:A4(active) 10 GbE KR/ 3
10 GbE KR 00:90:FA: 51:31:F1 F0:1F:AF:88:22:7E(active) NOTE: 10 GbE KR/3 — The value 3 indicates the protocol type. getioinfo Description Displays general information about the I/O modules on the chassis. To use this subcommand, you must have the CMC Login User privilege. NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fiber Channel, and Infiniband.
• • • server-4 Blinking racadm getled -m chassis server-4 Not blinking racadm getled -m server-1 server-1 ON racadm getled -m server-1 server-1 Extension(1) getmacaddress Description Displays the MAC/WWN addresses for all modules or for a specified module. The decoder values in the Type column indicate the protocols of the network cards.
– FlexAddress — Displays the chassis assigned WWN/MAC addresses. – Factory — Displays the MAC/WWN addresses for all LOMs or mezzanine cards. – all — Displays the console assigned MAC/WWN of all LOMs or mezzanine cards. Example • Displays the NDC or LOM MAC address. racadm getmacaddress • Display iSCSI MAC addresses for all servers. racadm getmacaddress -t iscsi • Display iSCSI MAC for server-1. racadm getmacaddress -m server-1 -t iscsi • Display extra iSCSI MACs for server-1 (if available).
Displays the MAC address for switch –1 racadm getmacaddress -m server-1 Server-1a Present F8:DB:88:3E: 01:80 F8:DB:88:3E: 01:81 F8:DB:88:3E: 01:84 Server-1b Present F8:DB:88:3E: 02:50 F8:DB:88:3E: 02:6F F8:DB:88:3E: 02:72 Server-1c Present F8:DB:88:3E: 08:09 F8:DB:88:3E: 01:E9 F8:DB:88:3E: 01:EC Server-1b Not Present Not Installed Not Installed Not Installed Display extr
Server-4 Not Installed Not Present Not Installed Not Installed Not Installed Switch-1 Gigabit Ethernet Present Not Installed 00:00:00:00:00 :00 Not Installed Displays Ethernet and iSCSI MAC address of all LOMs or mezzanine cards.
> > > Present 5C:F9:DD:D6:1 C:CE N/A Factory Gigabit Ethernet Present 84:8F: 69:FC:E8:F0 Unknown IO-Identity Gigabit Ethernet Present 84:8F: 69:FC:E8:F1 Unknown IO-Identity 10 GbE KR Present F8:B1:56:45:D D:BD N/A Factory Server-3-A IDRACController Switch-1 Displays the chassis assigned WWN/MAC address.
getmodinfo Description Displays configuration and status information for all modules or a specified module (server, storage sled, switch, CMC, fan unit, blower, power supply unit, chassis, mainboard, IO cable, and FPC cable) in the chassis. To use this subcommand, you must have CMC Login User privilege. NOTE: The Service Tag field is blank for modules that do not have Service Tags.
Fan-1 Present ON OK N/A N/A Fan-2 Present ON Unknown N/A N/A Fan-3 Present ON Unknown N/A N/A Fan-4 Present ON Unknown N/A N/A Fan-5 Present ON OK N/A N/A Fan-6 Present ON Unknown N/A N/A Fan-7 Present ON Unknown N/A N/A Fan-8 Present ON Unknown N/A N/A PS-1 Present Online OK N/A N/A PS-2 Present Online OK N/A N/A CMC Present Primary OK N/A N/A Switch-1 Present ON OK 0000000 N/A Switch-2 Present ON OK N/A N/A Server-1 Present OF
• chassis • : default state if -m is not specified server-n • : where n = 1 to 4 switch-n : where n = 1 or 2 Example racadm getniccfg NIC Enabled = 1 IPv4 Enabled = 1 DHCP Enabled = 1 Static IP Address = 192.168.0.120 Static Subnet Mask = 255.255.255.0 Static Gateway = 192.168.0.1 Current IP Address = 10.36.0.12 Current Subnet Mask = 255.255.254.0 Current Gateway = 10.36.0.
LOM Fabric Type = 10 GbE KR IPv4 Enabled = 1 DHCP Enabled = 1 IP Address = 10.35.0.159 Subnet Mask = 255.255.255.0 Gateway = 10.35.0.1 IPv6 Enabled = 0 Autoconfiguration Enabled = 0 Link local Address = IPv6 Gateway = :: VLAN Enable = 0 VLAN ID = 1 VLAN priority = 0 racadm getniccfg -m switch-1 DHCP Enabled = 1 IP Address = 10.35.155.223 Subnet Mask = 255.255.255.0 Gateway = 0.0.0.0 Output The getniccfg subcommand displays an appropriate error message if the operation is not successful.
IPv6 settings: IPv6 Enabled = 0 DHCP6 Enabled = 1 IP Address 1 = :: Gateway = :: Link Local Address = :: IP Address 2 = :: IP Address 3 = :: IP Address 4 = :: IP Address 5 = :: IP Address 6 = :: IP Address 7 = :: IP Address 8 = :: IP Address 9 = :: IP Address 10 = :: IP Address 11 = :: IP Address 12 = :: IP Address 13 = :: IP Address 14 = :: IP Address 15 = :: LOM Status: NIC Selection = Dedicated Link Detected = Yes Speed = 10Mb/s Duplex Mode = Half Duplex getpbi
Minimum System Power Minimum System Power Timestamp Overall Power Health Redundancy System Input Power Cap Redundancy Policy System Input Max Power Capacity Input Redundancy Reserve Max Power Conservation Mode Power Available for Server Power-on = = = = = = = = = = 83 W 20:28:02 03/04/2014 OK Yes 3371 W Redundancy Alerting Only 2382 W 0 W 11:20:08 02/27/2014 1965 W [Chassis Power Supply Status Table]
• PCIe slot-5 OFF PCIe Card 5 SLOT-02 PCIe slot-6 A Not Present UNMAPPED N/A PCIe slot-7 ON PCIe Card 7 localhost PCIe slot-8 A Not Present UNMAPPED N/A 2 N/ 1 N/ Displays the properties of a PCIe slot selected using FQDD: racadm getpciecfg -c pcie.chassisslot.1 getpminfo Description Displays power management status information. To use this subcommand, you must have CMC Login User privilege.
gettracelog Description Lists all the trace log entries in CMC. Synopsis • racadm gettracelog -i [-A] • racadm gettracelog [-s ] [-c ] [--more] [A] [-o] • • -i - Displays the number of entries in CMC trace log. --more - Displays one screen at a time and prompts the user to continue (similar to the UNIX more command). -o - Displays each entry in a single line. -c - Specifies the number of records to display. -s - Specifies the starting record to display.
20051208201542.000000 getsel Description Displays all sensor event log entries in the DRAC. Synopsis • • racadm getsel -i [-A] racadm getsel [-s ] [-c ] [-A] [-o] [-E] [-R] [--more] If no arguments are specified, the entire log is displayed. Input • • • • • • • • -A — Specifies output with no display headers or labels. -c — Provides the number of records to be displayed. -o — Displays each entry in the SEL in a single line. -s — Specifies the starting record used for the display.
• • Example • Displays the slot name for all the four slots in the chassis. -i < slotNum > - specifies the slot number. Values: 1 to 4 -h - Specifies whether to display the slot name or the host name (if available). 1 displays host names and 0 displays slot names. Display all slots names. racadm getslotname 1 SLOT-01 2 Webserver01 3 Webserver3 4 SLOT-04 WXP-8GRB221 WXP-319QWEecet5 • Display the name of the third slot.
CPU1 M23 VDDQ PG OK 0 600 N/A CPU1 M23 VTT PG OK 0 600 N/A CPU1 VSA PG OK 0 600 N/A CPU1 M01 VDDQ PG OK 0 600 N/A NDC PG OK 0 600 N/A CPU1 VTT PG OK 0 600 N/A MEZZB PG OK 0 600 N/A MEZZC PG OK 0 600 N/A PERC1 PG OK 0 600 N/A Sensor Type : Current System Board Current OK 22 3 -7 42 47 Sensor Type : Processor CPU1 Status OK Presence Detected N/A CPU2 Status
Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent DIMM SLOT Absent A12 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A OK N/A Sensor Type : Battery System Board CMOS Battery Present N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A <
racadm getssninfo SSNID Type User IP Address Login Date/Time 6 GUI root 192.168.0.10 04/07/2010 12:00:34 racadm getssninfo -A "root" "192.68.174.19" "Telnet" "NONE" racadm getssninfo -A -u * "root" "192.68.174.19" "Telnet" "NONE" "bob" "192.68.174.19" "GUI" "NONE" getstoragemoduleinfo Description Synopsis Displays the storage module configuration and status information.
FQDD = RAID.Modular.2-1 Physical Disk Slots = 0-15 Connected Server = SLOT-01 Controller Mode Capability = HBA and RAID Display format of storage sled information when the storage mode is “split single host”. racadm getstoragemoduleinfo -c System.Modular.03 Storage-2 FQDD = System.Modular.03 Chassis Slot = 3 Name = SLOT-03 Model = PowerEdge FD332 Status = Not OK Service Tag = 8748596 Asset Tag = KLOP98656 Intrusion State = Closed Storage Mode = Split single host Number of Controllers = 2 FQDD = RAID.
getsvctag Description Displays the Service Tag of the host system. Synopsis racadm getsvctag Input getsvctag Output Chassis Switch-1 Switch-2 Server-1 Server-2 Storage-3 Storage-4 Example racadm getsvctag STPST02 0000000 N/A FC830 Extension(1) 7647563 7654321 N/A N/A N/A FC830 N/A N/A N/A getsysinfo Description Displays information related to CMC and chassis.
VLAN Priority VLAN Enabled = 0 = 0 CMC IPv4 Information: IPv4 Enabled Current IP Address Current IP Gateway Current IP Netmask DHCP Enabled Current DNS Server 1 Current DNS Server 2 DNS Servers from DHCP = = = = = = = = 1 192.168.164.115 192.168.164.1 255.255.255.0 1 192.168.165.80 0.0.0.
• • • • -o - Displays each entry in a single line. -c - Specifies the number of records to display. -s - Specifies the starting record to display. -A - Does not display headers or labels. NOTE: The -A and -o options are deprecated. Output The default output display shows the record number, timestamp, source, and description. The timestamp begins at midnight, January 1 and increases until the system boots. After the system boots, the system’s timestamp is used.
• Example – bios: BIOS – idrac: iDRAC – usc: Unified Server Configurator (Lifecycle Controller) – diag: 32-bit Diagnostics – drivers: OS Driver Package – nic-x: Network Interface card. See -l output for possible values of x. -m < module > - Specifies the module or device for which you must retrieve the version information. < module > is one of the following: – server-n , where n = 1 to 4. – switch-n , where n = 1 to 2.
Example $ racadm ifconfig eth0 Link encap:Ethernet HWaddr 00:1D:09:FF:DA:23 inet addr:10.35.155.136 Mask:255.255.255.0 Metric:1 overruns:0 frame:0 carrier:0 Bcast:10.35.155.255 UP BROADCAST RUNNING MULTICAST MTU:1500 RX packets:2550665 errors:0 dropped:0 TX packets:0 errors:0 dropped:0 overruns:0 collisions:0 txqueuelen:1000 (0.0 B) RX bytes:272532097 (259.9 MiB) TX bytes:0 jobqueue Description Displays the jobs in that are currently being run, delete the jobs, and create a job.
-[Job ID=RID_852218430518] Job Name=Reboot4 Status=New Start Time=[NOW] Expiration Time=[NOW] --------------------------------------------------------[Job ID=RID_852215634901] Job Name=Reboot4 Status=New Start Time=[NOW] Expiration Time=[NOW] --------------------------------------------------------• Delete the specified job: racadm jobqueue delete -i RID_860202993201 • racadm jobqueue delete -i krbkeytabupload Description Uploads a Kerberos keytab file.
• Export the license using the following options: • – racadm license export [-u ] [-p ] [-f ] [-1 ] [—t ] – racadm license export [-u ] [-p ] [-f ] [-1 ] [—e ] – racadm license export [-u ] [-p ] [-f ] [-1 ] [—c ] – racadm license export [-u ] [-p ] [-f ] [-1
– View all the license information in the chassis. racadm license view CMC.Integrated.1 Status = OK Device = CMC.Integrated.1 Device Description = Chassis Management Controller for PowerEdge FX2/FX2s Unique Identifier = License #1 Status = OK Transaction ID = 8 License Description = CMC Enterprise Evaluation License EVALUATION A2Wir6lJ1MoP8iBAtqsEKDv8 1982-04-07T21:00:00 License Type = Entitlement ID = Expiration = – View the storage sled license information in the chassis.
– Import a storage sled license racadm license import -f nfs/"8YYGCVtSMcHDZ79crzqfZmvb_xyz_single raid.xml" -| 192.168.2.140:/nfs -c System.Modular.04 • Export a license file: – Export license to an NFS share using transaction ID (for example, transaction 27). racadm license export -f License.xml -l 192.168.2.140:/licshare -t 27 – Export the license to a CIFS share specifying the entitlement ID (for example, abcdxyz): racadm license export -u admin -p passwd -f License.xml -l //192.168.2.
netstat Description Displays the routing table and the current connections. To use this subcommand, you must have the Execute Diagnostic Commands permission. Synopsis racadm netstat Input racadm netstat Output Kernel IPv6 routing table Destination Hop Use Iface :: 1/128 U fe80::200:ff:fe00:d01/128 fe80::/64 ff00::/8 Next Flags Metric Ref 0 :: 30 U 0 0 U 256 0 U 256 0 Kernel IP routing table Destination Gateway MSS Window irtt Iface 192.168.161.0 0.0.0.0 0 0 0 bond0 0.0.0.0 198.168.161.
ping Description Verifies that the destination IP address is reachable from CMC with the current routing-table contents. A destination IP address is required. An ICMP echo packet is sent to the destination IP address based on the current routing-table contents. To use this subcommand for CMC, you must have the Administrator privilege for CMC.
• • • • • • • • • • • • Output Session information - getssinfo Sensor information - getsensorinfo Switches information (IO Module) - getioinfo Mezzanine card information (Daughter card) - getdcinfo All modules information - getmodinfo Power budget information - getpbinfo KVM information - getkvminfo NIC information (CMC module) - getniccfg Redundancy information - getredundancymode Trace log information - gettracelog RAC event log - getraclog System event log - getsel The following information is displaye
Session Information =============================================================================== Type SSH KVM User root root IP Address 10.9.72.252 169.254.31.
• Reset servers 1 and 3. racadm racreset -m server-1 -m server-3 racresetcfg Description Resets CMC configuration to factory default settings. NOTE: To use this, you must have the Chassis Administrator privilege. Synopsis racadm racresetcfg [-m ] [-c ] Input • -m : — Must be one of the following values: • – chassis — default state, if -m is not specified.
To use this subcommand, you must have the Administrator permission. Synopsis racadm remoteimage Input • • • • • • Example • -c - Connect the image. -d - Disconnect the image. -u - Username to access the network share. -p - Password to access the network share. -l - Image location on the network share; use double quotation marks with a location. -s - Display current status; –a is assumed, if not specified. racadm remoteimage -c -u "user" -p "pass" -l //shrloc/ foo.
— powerdown — Turns off the managed system. — powerup — Turns on the managed system. — powerstatus — Displays the current power status of the server (ON or OFF). — reseat — Performs a virtual reseat of the server. This operation simulates reseating the server by resettig the iDRAC on a server. NOTE: The reseat option is not available for individual FM120 servers. NOTE: The action powerstatus is not allowed with an -a option.
set Description Import saved CMC Event Filter configuration from a file. NOTE: Currently, these commands are supported only in remote racadm. Synopsis racadm set -f Input –f : Configure event filter configurations from a configuration file. Example –Import event filter configuration from a file. racadm -r 10.94.161.119 -u root -p set -f config.txt setassettag Description Sets the N-byte ASCII asset tag for the chassis.
NOTE: Chassis name is a maximum of 64 non-extended ASCII characters. Example racadm setchassisname dellchassis-1 The chassis name was set successfully.root setflexaddr Description Enables or disables FlexAddress on a particular slot or fabric. To use this subcommand, you must have the Chassis Configuration Administrator privilege. If the fabric type is determined to be Infiniband, the operation is canceled and the command returns an error.
unblink, you must have the Server Administrator or Debug Administrator privilege on CMC. Synopsis racadm setled -m -l Input • -m - Specifies the module whose LED you want to configure. can be one of the following: — server-n, where n=1–4 — switch-n, where n=1–2 — cmc-active — chassis • -l - Specifies whether the LED should blink.
• • • • • • Input • • • • • • • • racadm setniccfg gateway> racadm setniccfg racadm setniccfg racadm setniccfg racadm setniccfg racadm setniccfg ] -s -o —p [-6} [-m ] —k [ ] [-i ] —v [ -d — Enables DHCP for the NIC (default is “DHCP disabled”.) -d6 — Enables AutoConfig for the NIC. It is enabled by default. -s — Enables static IP settings.
– Disables IPv6 (w/ -p option) – Can be specified for chassis or servers Example • racadm setniccfg -s 192.168.0.120 255.255.255.0 192.168.0.
— mm is the minutes — ss is the seconds — mmmmmm is the number of microseconds — s is a + (plus) sign or a - (minus) sign, which indicates the sign of the offset. — off is the offset in minutes NOTE: 'Off' is the offset in minutes from GMT and must be in 15-minute increments. The timezone is represented as an offset from GMT, and the clock does not automatically adjust to daylight savings time (for the '-d' option). • -z - Sets the time zone by name or index, or lists possible time zones.
setslotname Description Sets the name of the slot and enables the feature to display the host name (if available) of all the four slots, or of a specified slot (indicated by the slot number) in the chassis. Optionally, use this command to set whether the slot name or host name is displayed in the CMC Web interface or with the getslotname -i command. If the host name is not available, the static slot name is used. To use this subcommand, you must have the Administrator privilege.
Example racadm setsysinfo -c chassisname "Dell Rack System" The chassis name was set successfully. SSH or Telnet RACADM • racadm getconfig -g [-o ][-i ] • racadm Example • racadm getconfig -g idracinfo • racadm getsysinfo sshpkauth Description Enables you to upload and manage up to four different SSH public keys per user. You can upload a key file or key text, view keys, or delete keys.
The delete mode allows the user to delete a key specified by the user or all keys. racadm sshpkauth -i <2 to 16> -d -k <1 to 4> racadm sshpkauth -i <2 to 16> -d -k all Synopsis racadm sshpkauth NOTE: For DSA keys greater than 2048, use the following racadm command. CMC accepts RSA keys up to key strength 4096, but the recommended key strength is 1024. racadm -r 192.168.8.14 -u root -p sshpkauth -i svcacct -k 1 -p 0xfff -f dsa_2048.
wilU2VLw/iRH1ZymUFnut8ggbPQgqV2L8bsUaMqb5PooIIvV6hy4isCNJU= 1024-bit RSA, converted from OpenSSH by xx_xx@xx.xx Key ID 2: Key ID 3: Key ID 4: sslkeyupload Description Uploads SSL key from the client to CMC. To use this subcommand, you must have Server Administrator permission. Synopsis racadm sslkeyupload -t -f Input • • -t — Specifies the key to upload. 1 = SSL key used to generate the server certificate -f — Specifies the file name of the SSL key to be uploaded.
Output The sslcertupload command returns 0 when successful, and returns a nonzero number when unsuccessful. Example racadm sslcertupload -t 1 -f c:\cert\cert.txt sslcertview Description Displays the SSL server or CA certificate that exists on CMC.. To use this subcommand, you must have the CMC Login User privilege. Synopsis racadm sslcertview -t [-A] Input • -t — Specifies the type of certificate to view, either the CA certificate or server certificate.
Organizational Unit (OU) Remote Access Group Common Name (CN) CMC Default certificate Common Name (CN) CMC Default certificate Valid From Jul 8 16:21:56 2005 GMT Valid To Jul 7 16:21:56 2010 GMT racadm sslcertview -t 1 -A 00 US Texas Round Rock Dell Inc. Remote Access Group CMC default certificate US Texas Round Rock Dell Inc.
NOTE: If the -f option is not specified, the filename defaults to sslcsr in your current directory. Output If no options are specified, a CSR is generated and downloaded to the local file system as sslcsr by default. The -g option cannot be used with the -s option, and the -f option can only be used with the -g option. The sslcsrgen -s subcommand returns one of the following status codes: • • Example CSR was generated successfully. CSR does not exist. racadm sslcsrgen -s or racadm sslcsrgen -g -f c:\csr
Example Commands for the cfgEmailAlert group: • Enable the alert — racadm config -g cfgEmailAlert -o cfgEmailAlertEnable i 1 • Set the destination e-mail address — racadm config -g cfgEmailAlert -o cfgEmailAlertAddress i 1 user1@mycompany.
• • • • • • Verifies whether the required system resources are available. Validates Active Directory configuration. Verifies the SSL certificate and if the certificate signing request (key) exists. Acquires LDAP and Global Catalog Service records from DNS. Acquires user privileges from the Active Directory server. Checks the time to acquire user privileges with the allotted time to login.
Description Tests LDAP configuration and operation, and reports success as each stage of the authentication process proceeds. After successful completion, this command prints the CMC privileges assumed by the specified . If a failure occurs, the command stops with an error message that displays the required corrective action. Use the optional -d switch to obtain additional diagnostic information, as needed.
Output traceroute to 192.168.0.1 (192.168.0.1), 30 hops max, 40 byte packets 1 192.168.0.1 (192.168.0.1) 0.801 ms 0.246 ms 0.253 ms traceroute6 Description Traces the network path of routers that packets take as they are forwarded from your system to a destination IPv6 address. To use this subcommand, you must have the Administrator permission.
CMC Property Database Group and Object Descriptions 3 The CMC property database contains the configuration information for CMC. Data is organized by associated object, and objects are organized by object group. The IDs for the groups and objects that the property database supports are listed in this section for CMC. Use the group and object IDs with the RACADM subcommands to configure CMC. NOTE: RACADM sets the value of objects without performing any functional validation on them.
idRacDescriptionInfo (Read Only) Description A text description of the RAC type. Legal Values A string of up to 255 ASCII characters. Default This system component provides a complete set of remote management functions for Dell PowerEdge servers. idRacVersionInfo (Read Only) Description String containing the current product firmware version. Legal Values A string of up to 63 ASCII characters. Default The current version number.
The following sections provide information about the objects in the cfgLanNetworking group. cfgNicIPv4Enable (Read or Write) Description Enables or disables the IPv4 stack. Legal Values • • 1 (TRUE) 0 (FALSE) Default • For iDRAC: 0 • For CMC: 1 cfgNicVLanEnable (Read or Write) Description Enables or disables the VLAN capabilities. All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when enabled.
Example racadm config -g cfgLanNetworking -o cfgNicVLanPriority 7 cfgDNSDomainNameFromDHCP (Read/Write) Description Specifies that the DNS domain name should be assigned from the network DHCP server. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) This property is used only if cfgNicUseDhcp is set to 1 (true), or if both cfgCurrentIPv6Enabled and cfgIPv6AutoConfig are set to 1 (true).
cfgDNSRacName (Read/Write) Description Displays the CMC name, which is rac-service tag by default. This parameter is only valid if cfgDNSRegisterRac is set to 1 (TRUE). Legal Values A string of up to 63 ASCII characters. At least one character must be alphabetic. NOTE: Some DNS servers only register names of 31 characters or fewer. Default cmc- cfgDNSRegisterRac (Read/Write) Description Registers the CMC name on the DNS server.
Example: racadm getconfig -g cfgLanNetworking cfgNicEnable=1 cfgNicIPv4Enable=1 cfgNicIpAddress=192.168.22.101 cfgNicNetmask=255.255.255.0 cfgNicGateway=192.168.22.101 cfgNicUseDhcp=1 # cfgNicMacAddress=00:00:00:00:00:01 cfgNicVLanEnable=0 cfgNicVLanID=1 cfgNicVLanPriority=0 cfgDNSServersFromDHCP=1 cfgDNSServer1=192.168.0.5 cfgDNSServer2=192.168.0.6 cfgDNSRacName=cmc-frankly cfgDNSDomainName=fwad.
cfgDNSServer2 (Read/Write) Description Retrieves the IPv4 address for DNS server 2. This parameter is only valid if cfgDNSServersFromDHCP is set to 0 (FALSE). NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while swapping addresses. Legal Values String representing a valid IPv4 address. For example: 192.168.0.20. Default 0.0.0.0 cfgNicEnable (Read/Write) Description Enables or disables CMC network interface controller.
cfgNicGateway (Read/Write) Description CMC gateway IPv4 address. The gateway IPv4 address used for static assignment of the RAC IP address. This property is only valid if cfgNicUseDhcp is set to 0 (FALSE). NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set to 0 (FALSE). Legal Values String representing a valid gateway IPv4 address. For example: 192.168.0.1. Default 192.168.0.
NOTE: In the current CMC firmware version, the objects cfgUserAdminEnable and cfgUserAdminPrivilege are interrelated; changing the value of one property causes the value of the other property to change. For example, if a user does not have login privilege, the user is disabled by default. When you enable the user by changing the value of UserAdminEnable to 1, the right most digit of the UserAdminPrivilege also becomes 1.
Configure iDRAC 0x00000002 Configure Users 0x00000004 Clear Logs 0x00000008 Execute Server Control Commands 0x00000010 Access Virtual Console 0x00000020 Access Virtual Media 0x00000040 Test Alerts 0x00000080 Execute Debug Commands 0x00000100 CMC Specific User Privilege CMC Login User 0x0000001 Chassis Configuration Administrator 0x0000002 User Configuration Administrator 0x0000004 Clear Logs Administrator 0x0000008 Chassis Control Administrator 0x0000010 Super User 0x0000020 Serv
The user may only log in to CMC and view CMC and server configuration information. 0x00000001 The user may log in to CMC and change configuration. 0x00000001 + 0x00000002 = 0x00000003 The user may log in, access Virtual Media, and Virtual Console. 0x00000001 + 0x00000040 + 0x00000080 = 0x000000C1 cfgUserAdminUserName (Read/Write) Description The name of the user for this index. The user index is created by writing a string into this name field if the index is empty.
Use this object with the getconfig and config subcommands. To use this object property for, you must have Chassis Configuration Administrator privileges. The following sections provide information about the objects in the cfgEmailAlert group. cfgEmailAlertIndex (Read Only) Description The unique index of an alert instance. Legal Values 1-4 Default cfgEmailAlertEnable (Read/Write) Description Enables or disables the alert instance.
cfgSessionManagement This group contains parameters to configure the number of sessions that can connect to CMC or iDRAC. One instance of the group is allowed. Displays current settings for and configures idle timeout properties for Web server, Telnet, SSH, and RACADM sessions. Changes to idle timeout settings take effect at the next login. To disable idle timeout for a connection, set this property to 0. The following sections provide information about the objects in the cfgSessionManagement group.
The following sections provide information about the objects in the cfgSerial group. cfgSerialBaudRate (Read/Write) Description Sets the baud rate on the serial port. Legal Values 2400, 4800, 9600, 19200, 28800, 38400, 57600,115200 Default 115200 cfgSerialConsoleEnable (Read/Write) Description Enables or disables the RAC or CMC serial console interface.
cfgSerialConsoleColumns Description Specifies the number of columns in the terminal window command line connected to the serial port. You must log out, then log in again for the changes to take effect. NOTE: The prompt counts as two characters. NOTE: The terminal emulator must be configured with the line wrap mode ON, if a terminal emulator is used. Legal Values 0–256 Default 0 (equivalent to 80) cfgSerialHistorySize (Read/Write) Description Specifies the maximum size of the serial history buffer.
Use this object with the config or getconfig subcommands. To use this object property, you must have Chassis Configuration Administrator privilege. The following sections provide information about the objects in the cfgOobSnmp group. cfgOobSnmpAgentCommunity (Read/Write) Description Specifies the SNMP Community Name (identical to community string) used for SNMP traps. The community string acts as a password shared between different hosts over the network.
cfgTrapsEnable Description Enables or disables event traps. Legal Values • • Default None 1 (TRUE) 0 (FALSE) cfgTrapsAlertDestIpAddr Description Sets the IP address that receives the alert. Legal Values A string representing a valid IP address. For example, 192.168.0.20. Default None cfgTrapsCommunityName Description Sets the community string (identical to the community name) used for authentication. The community string acts as a password shared between different hosts over the network.
cfgRacTuneDefCredentialWarningEnable Description Enables or disables the display of the default password warning message. Legal Values 0 and 1 Default 1 cfgRacTuneRemoteRacadmEnable (Read/Write) Description Enables or disables the Remote RACADM interface.
Default 443 cfgRacTuneIpRangeEnable (Read/Write) Description Enables or disables the IPv4 Address Range validation feature. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgRacTuneIpRangeAddr (Read/Write) Description Specifies the acceptable IPv4 address bit pattern in positions determined by the 1s in the range mask property (cfgRacTuneIpRangeMask).
Default 0 cfgRacTuneIpBlkFailCount (Read/Write) Description The maximum number of login failures to occur within the window (cfgRacTuneIpBlkFailWindow) before login attempts from the IP address are rejected. Legal Values 2 – 16 Default 5 cfgRacTuneIpBlkFailWindow (Read/Write) Description Defines the time span in seconds that the failed attempts are counted. When failure attempts age beyond this limit, they are dropped from the count.
NOTE: For CMC, the following port numbers are reserved and cannot be used: 21, 68, 69, 111, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106. Legal Values • • Default 23 For CMC: 10 – 65535 For iDRAC: 1 – 65535 cfgRacTuneDaylightOffset (Read Only) Description Specifies the daylight savings offset (in minutes) to use for the RAC Time. This value is 0 if the time zone is not a Daylight Saving time zone.
For CMC: This object property is read only. Specifies the difference in number of seconds, from the UTC/GMT. This value is negative if the current time zone is west of Greenwich. Legal Values - 720–7800 Default 0 cfgRacTuneSledNetworkUplink Description Configuration of all the sleds that contain an internal network switch (for example, the FM120).
# cfgRacTuneTimezoneOffset=-18000 # cfgRacTuneDaylightOffset=3600 cfgRacTuneWebserverEnable (Read/Write) Description Enables or disables the Web server. If this property is disabled, CMC is not accessible using client Web browsers. This property has no effect on the Telnet/SSH or RACADM interfaces. Legal Values • • Default 1 1 (TRUE) 0 (FALSE) cfgServerInfo For CMC, this group allows you to displays information for and configure a server in the chassis.
cfgServerFW (Read Only) Description Displays the server's CMC management firmware revision. cfgServerBIOS (Read Only) Description Displays the server's BIOS revision. cfgServerBmcMacAddress (Read Only) Description Displays the BMC MAC address of the specified server. cfgServerNic1MacAddress (Read Only) Description Displays the MAC address of the server NIC 1. cfgServerNic2MacAddress (Read Only) Description Displays the MAC address of the server NIC 2.
cfgServerIPMIOverLanEnable (Read/Write) Description Enables or disables IPMI LAN channel. Legal Values • • 1 (enable) 0 (disable) cfgServerDNSRegisterIMC (Read/Write) Description Enables or disables DNS name registration for the CMC. Legal Values • • 1 (enable) 0 (disable) cfgServerDNSIMCName (Read/Write) Description Displays the DNS domain name for the CMC. cfgServerRootPassword (Write Only) Description Displays the password for CMC as a series of asterisks (*).
Default • 52 = F10 • 60 = FDD 0 = None cfgServerBootOnce (Read/Write) Description Enables or disables the server boot once feature. This object is read-write. Legal Values • • Default 0 1 = TRUE 0 = FALSE cfgStorageModule This group contains the parameters to configure storage sleds. Use this command with the config and getconfig commands. To use this object property, you must have the Chassis Configuration Administrator privilege.
ConnectedServer (Read Only) Description Displays the name of the compute sled to which storage sled is connected. Legal Values None Default Value None RAID-EnabledControllers (Read Only) Description Displays the name of the RAID-enabled controller. This property is updated when the single RAID or dual RAID license is applied. Legal Values None Default Values None cfgActiveDirectory This group contains parameters to configure the Active Directory feature.
cfgADRacDomain (Read or Write) Description Active Directory Domain in which CMC resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADRootDomain Description Specifies the root domain of the domain forest. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgADEnable (Read/Write) Description Enables or disables Active Directory user authentication on CMC.
cfgADSSOEnable (Read/Write) Description Enables or disables Active Directory single sign-on authentication on CMC. Legal Values • • Default 0 1 (TRUE) 0 (FALSE) cfgADDomainController Description Specifies the AD server from which you want the CMC to obtain user names. Must be used with cfgADSpecifyServerEnable. Legal Values Valid IP address or fully qualified domain name (FQDN).
cfgADGlobalCatalog2 (Read/Write) Description Specifies the Global Catalog server from which you want the CMC to obtain user names. Legal Values A string of up to 254 ASCII characters representing a valid IP address or a fully qualified domain name (FQDN). cfgADGlobalCatalog3 (Read/Write) Description Specifies the Global Catalog server from which you want the CMC to obtain user names.
cfgADDcSRVLookupEnable (Read/Write) Description Configures CMC to use pre‑configured domain controllers or to use DNS to find the domain controller. If using pre‑configured domain controllers, then the domain controllers to use are specified under cfgAdDomainController1, cfgAdDomainController2, and cfgAdDomainController3. CMC does not fail over to the specified domain controllers when DNS lookup fails or none of the servers returned by the DNS lookup works.
cfgLdapServer (Read/Write) Description Configures the address of the LDAP Server. IPv4 and IPv6 are supported. NOTE: You can specify multiple servers by separating each server with a comma. For example, example.com, sub1.example.com Legal Values String. Maximum length = 254 Default Null cfgLdapPort (Read/Write) Description Port of LDAP over SSL. Non-SSL port is not supported.
cfgLdapGroupAttribute (Read/Write) Description Specifies which LDAP attribute is used to check for group membership. This should be an attribute of the group class. If not specified, then CMC uses the member and unique member attributes. Legal Values String. Maximum length = 254 Default Null cfgLdapGroupAttributeIsDN (Read/Write) Description If enabled, the CMC performs DN matching; otherwise, the CMC uses the username provided at login for matching.
cfgLdapSearchFilter (Read/Write) Description A valid LDAP search filter. This is used if the user attribute cannot uniquely identify the login user within the chosen baseDN. The search filter only applies to userDN search and not the group membership search. Legal Values String of maximum length = 1024 characters Default (objectclass=*) Searches for all objects in tree. cfgLDAPCertValidationEnable (Read/Write) Description Controls certificate validation during SSL handshake.
cfgLDAPSRVLookupEnable Description Configures the CMC to query a DNS server for SRV records. Legal Values • • Default 0 1 (true) 0 (false) cfgLDAPSRVLookupServiceName (Read/Write) Description Configures the service name to be used in the SRV lookup. Legal Values String of maximum length of 254 characters. Default ldap cfgLdapRoleGroup Use this object with the getconfig or config subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege.
Default None Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupDN -i 1 cn=everyone,ou=groups,dc=openldap,dc=com cfgLdapRoleGroupPrivilege (Read/Write) Description A bit–mask defining the privileges associated with this particular group. Legal Values 0x00000000 to 0x000001ff Default 0x000 Example racadm getconfig -g cfgLDAPRoleGroup -o cfgLDAPRoleGroupPrivilege -i 1 0x0 cfgLocation This group defines objects that support physical location properties.
Default 0 cfgLocationRackslot (Read/Write) Description Indicates the slot where a server is located. Legal Values Values from 1 - 255 (1 Byte) Default 0 cfgLocationDevicesize (Read Only) Description Indicates server chassis size. Legal Values Values from 1 - 255 Default 2U cfgStandardSchema This group contains parameters to configure the Active Directory standard schema settings. Use this object with thegetconfig or config subcommands.
cfgSSADRoleGroupDomain (Read/Write) Description Active Directory Domain in which the Role Group resides. Legal Values Any printable text string of up to 254 characters, with no white space. Default cfgSSADRoleGroupPrivilege (Read/Write) Description Use the bit mask numbers listed in the table below to set role-based authority privileges for a Role Group.
cfgChassisPower This group is applicable only to CMC and contains parameters to display or configure power for the chassis. Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege. The following sections provide information about the objects in the cfgChassisPower group.
cfgChassisMinPowerTimestamp (Read Only) Description The timestamp recorded when the minimum system power occurred. Legal Values None Default None cfgChassisPowerStatus (Read Only) Description Indicates the power status of the chassis. Legal Values • • • • • • Default None 1 (other) 2 (unknown) 3 (OK) 4 (non-critical) 5 (critical) 6 (non-recoverable) cfgChassisRedundantState (Read Only) Description Indicates the power supply redundancy status.
cfgChassisPowerCapUpperBound (Read Only) Description Indicates the minimum chassis thermal capacity, power supply capacity, and server maximum input. Legal Values Default cfgChassisPowerCapLowerBound (Read Only) Description Indicates the minimum power required to operate the chassis with the servers running. Legal Values Default cfgChassisSledPowerButtonEnable Description Permits to use the power button on all multi-node Sleds (such as the FM120).
cfgChassisPowerCapBTU (Read/Write) Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command generates an error if server throttling is necessary to achieve the power goal based on the value for this setting. Legal Values 1839-11501 BTU/hr Default 11501 BTU/hr cfgChassisPowerCapFBTU (Read/Write) Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis.
Default 100 cfgChassisRedundancyPolicy (Read/Write) Description Sets the redundancy policy of the chassis. Legal Values • • • Default 3 ( Redundancy Alerting Only) 0 (no redundancy) 1 (Grid redundancy) 3 ( Redundancy Alerting Only) cfgChassisInMaxPowerCapacity (Read Only) Description Indicates the total chassis power budget (in watts) available for chassis operation.
cfgChassisPowerClearTimestamp (Read Only) Description Time stamp when cfgChassisMinPower and cfgChassisMaxPowerCapacity were reset. Legal Values None Default None cfgChassisPowerButtonEnable (Read/Write) Description Indicates if the chassis power button is enabled or disabled. Legal Values • • Default None 0 (disabled) 1 (enabled) cfgChassisPowerCapBTU (Read/Write) Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis.
cfgKvmMapping Description Selects the server to which the KVM connects Legal Values 1[a-d]-4[a-d] Default 0 (Unmapped) cfgAlerting This group is enables or disables SNMP event trap alerting and sets the event filter. Use this object with the config or getconfig subcommands. To use this object property, you must have the Chassis Configuration Administrator privilege. cfgAlertingEnable Description Enables or disables event traps on the CMC.
Use this object with the config or getconfig subcommands. To use this object property for CMC, you must have Chassis Configuration Administrator privilege. NOTE: To apply this setting to iDRAC, use the -m option. The following sections provide information about the objects in the cfgIPv6LanNetworking group. cfgIPv6Enable (Read or Write) Description Enables or disables CMC IPv6 stack.
NOTE: This property is used only if cfgIPv6AutoConfig is set to 0 (false) Legal Values 0–128 Default 64 cfgIPv6Gateway (Read/Write) Description CMC gateway IPv6 address. NOTE: This property is used only if cfgIPv6AutoConfig is set to 0 (false.) Legal Values Specifies string representing a valid IPv6 entry. Default :: cfgCurrentIPv6DNSServersFromDHCP6 Description Indicates whether the DNS server addresses are assigned from the DHCPv6 server.
Example $ racadm getconfig -g cfgIPv6LanNetworking cfgCurrentIPv6Enabled=1 cfgIPv6AutoConfig=1 cfgIPv6Address=:: cfgIPv6PrefixLength=64 cfgIPv6Gateway=:: cfgIPv6DNSServersFromDHCP6=1 cfgIPv6DNSServer1=:: cfgIPv6DNSServer2=:: If both IPv4 and IPv6 are enabled on the CMC, IPv6 DNS servers take priority.
cfgNicCurrentGateway Description Displays the Gateway address the CMC is currently using. Legal Values Valid IPv4 addresses. For example: 192.168.0.20. cfgNicCurrentDhcpWasUsed Description Indicates whether DHCP is used to configure the NIC. Legal Values 0 – address is static. 1– address was obtained from the DHCP server. Default None cfgNicCurrentVlanEnable (Read Only) Description Indicates whether the VLAN is enabled.
cfgDNSCurrentDomainName Description Displays the DNS domain name. cfgNicCurrentIPv4Enabled Description Indicates whether IPv4 is enabled on the CMC. If the current property value is set to 0 (false), the remote network interfaces to the CMC are not accessible over IPv4. Example racadm getconfig -g cfgCurrentLanNetworking # cfgNicCurrentIPv4Enabled=1 # cfgNicCurrentIpAddress=192.68.152.116 # cfgNicCurrentNetmask=255.255.255.0 # cfgNicCurrentGateway=192.68.152.
1 (address is obtained from the DHCPv6 server and/or stateless auto configuration) Default None cfgCurrentLinkLocalAddress Description Displays the current IPv6 link-local address of the CMC. cfgCurrentIPv6Address Description Displays the current IPv6 addresses. This property displays up to 15 global IPv6 addresses, including stateful and stateless addresses. cfgCurrentIPv6Gateway Description Displays the current IPv6 gateway.
cfgNetTuningNicSpeed Description Specifies the speed for the CMC NIC. This property is used only if cfgNetTuningNicAutoNeg is set to 0. Legal Values 10, 100, or 1000 Default 100 cfgNetTuningNicAutoneg (Read/Write) Description Enables autonegotiation of physical link speed and duplex. If enabled, autonegotiation takes priority over other values set in this group.
cfgNetTuningNicRedunadant Description Specifies either Stacking or Redundant mode for CMC Management Port 2. Legal Values • • Default 0 – Stacking 0 – Stacking 1 – Redundant NOTE: When Management Port 2 is set for Redundant but is cabled for Stacking, the downstream CMCs (further from the top-of-rack switch) will not have a network link. NOTE: When Management Port 2 is set for Stacking but is cabled for Redundant (two connections to the TOR switch), routing loops could cause a network storm.
cfgRacSecCsrOrganizationUnit (Read/Write) Description Specifies the CSR Organization Unit (OU). Legal Values A string of up to 254 characters. Default cfgRacSecCsrLocalityName (Read/Write) Description Specifies the CSR Locality (L). Legal Values A string of up to 254 characters. Default cfgRacSecCsrStateName (Read/Write) Description Specifies the CSR State Name (S). Legal Values A string of up to 254 characters.
cfgRacSecStateName= cfgRacSecCountryCode= cfgRacSecEmailAddr= cfgRacSecCsrKeySize (Read/Write) Description Specifies the SSL asymmetric key size for the CSRs. Legal Values 1024, 2048, 4096 Default 2048 cfgPCIe Displays the PCIe reassignment information. Use this sub command with the getconfig and config commands. The following section provides information about the objects in the cfgPCIe group.