Model SWH-2100 Contactless Smart Card 13.
CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTRODUCTION The SWH-2100 Contactless Smart Card reader will read Smart Cards at a frequency of 13.56 MHz. The reading capability includes, for Smart Cards, both serial numbers and programmed sectors along with both encrypted and unencrypted ID data. Compatible standards include ISO 15693, ISO 14443A and MIFARE® sector. Refer to Table 1 for a complete list of compatible standards and data. TABLE 1.
FEATURES Universal compatibility with all ISO 15693 and ISO 14443A credentials (badges, disk tags and key fobs). Reads most 13.56 MHz credentials in the same reader.
MOUNTING Mount the single-gang backplate (with tamper magnet installed) onto the wall. L A I T N E D I FIGURE 1. Model SWH-2100 Reader Backplate F (includes tamper switch magnet) N O C NOTE o c y T Mounting holes fit standard U.S. single-width electrical box and standard European (EMEA) electrical box hole patterns.
Mount the reader module directly to the backplate and then snap the front cover in place as indicated in Figure 2. L A I T N E D I F N O C FIGUREo 2. Mounting Assembly c (including 1 optional isolation spacer) Ty INSTALLATION CONSIDERATIONS An isolation spacer (available from Software House, part number SWH-ISOSPC) may be used to improve the read range distance when mounting the reader to a metal surface. To optimize reader range, use the number of backplates as indicated in Table 2.
TABLE 2. Isolation spacer recommendation for mounting the SWH-2100 reader on metal. Distance Reading Distance No metal plate 100% 4.5 cm 100% 2.7 cm (3 tamper plates) 85% 1.8 cm (2 tamper plates) 70% 0.9 cm (1 tamper plate) 50% 0 cm 10% L A I Tside-by-side N Installation of two SWH-2100 readers E D I and back-to-back F N O Read range is not affected if the C center-to-center distance between two readers is greater than or equal (101.6 mm).
WIRING The Model SWH-2100 has twelve terminals as noted in Table 3. The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') and push the wire into the connector until the insulation is flush or inside the connector body. This is particularly critical for outdoor readers.
Table 4 indicates maximum wiring distances per Wiegand standard with the three most common gauges of cable. TABLE 4. Maximum cable distance for 18, 20, or 22 AWG wire Wire Gauge 18 AWG 20AWG 22 AWG Cable Distance 500 feet (152 meters) 300 feet (91 meters) 200 feet (61 meters) INSTALLATION NOTES Unless otherwise specified in this manual, please follow these guidelines: L A I T N E D I F N Oa power source with limited power 3.
TROUBLESHOOTING If the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. TABLE 5. Error Conditions and Possible Solutions Condition Possible Solutions None of the LEDs are on. Check the following: The door does not open and the green LED does not light when a qualified credential is presented.
MODEL SWH-2100 TECHNICAL SPECIFICATIONS Cable Recommendations: 4 core (minimum), shielded, 22 AWG (minimum) cable. Connectors: 12 position, 3.
Index of Protection: IP 65 (IEC 529) Read Range: 1 to 5 inches depending on credential technology and environment. Note: Read range for credentials of identical technologies may vary greatly depending on the tuning and antenna structure of each individual credential. Standard Wiegand Output including: Sector Pass-through Serial Number Read Fixed Wiegand bit stream option SmartFrame® encrypted MIFARE® Sector read and conversion to Wiegand.
FCC DIGITAL DEVICE LIMITATIONS Radio and Television Interference This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
CANADIAN RADIO EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. L A I T N E Inc.
CE MARKING Hereby, Software House declares that this equipment, if used according to the instructions, is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC. For use in all countries of the EU.
Copyrights and Trademarks This document contains proprietary information of Tyco International, Inc. and is furnished to its customer solely to assist in the installation, testing, operation and maintenance of the equipment described. This document may not be reproduced in whole or in part without the written approval of Tyco International. Copyright 2005 Tyco International All rights reserved. Printed in Germany. Software House is a trademark of Sensormatic Electronics Corporation.