Wiring and Installation Instructions PRM 5 PRM 5 Wiring and Installation Instructions V 1.0 03.01.
Wiring and Installation Instructions PRM 5 FCC Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Wiring and Installation Instructions PRM 5 Contents 1 2 Technical Data Wiring Diagram 2.1 PRM 5 Wiegand 2-wire 2.2 PRM 5 Magstripe Emulation 2.3 PRM 5 RS 232 2.4 PRM 5 RS 485 2.5 Supervised F2F 3 Mechanical Dimensions 3.1 PRM 5 Reader 3.2 Surface Spacer AP5 3.3 Flush Mounting Bezel FM5 4 Communications Protocol 4.1 Wiegand Standard 4.2 Data/Clock 4.3 Magstripe Emulation 4.3.1 Magstripe Interface according to ISO 7811/2-1995 - Track 2 4.
Wiring and Installation Instructions PRM 5 1 Technical Data Mounting: 1. Flush mounting in non-metallic surfaces 2. Surface mounting using an AP5 spacer 3. Mounting on single-gang electrical box using fixing plate FM 5 Material: ASA plastic housing; polyurethane encapsulated electronics Housing dimensions: 80 x 80 x 16 mm Temperature range: -25...+70 °C Power supply: 8...
Wiring and Installation Instructions PRM 5 2 Wiring Diagram Rear view of the reader 2.1 PRM 5 Wiegand 2-wire 2.2 PRM 5 Magstripe Emulation 03.01.
Wiring and Installation Instructions PRM 5 2.3 PRM 5 RS 232 RXD can be connected to Pin 5, but without any function. 2.4 03.01.
Wiring and Installation Instructions PRM 5 2.5 03.01.
Wiring and Installation Instructions PRM 5 3 Mechanical Dimensions 3.1 PRM 5 Reader 30 30 26 ° 11,50 0 R2 R 12,50 7,50 2,50 52 80 R5 R4 , 69,50 80 3.2 75 15,80 All dimensions in mm Surface Spacer AP5 All dimensions in mm 03.01.
Wiring and Installation Instructions PRM 5 3.3 Flush Mounting Bezel FM5 All dimensions in mm 03.01.
Wiring and Installation Instructions PRM 5 4 Communications Protocol 4.1 Wiegand Standard 4.2 Data/Clock 4.3 Magstripe Emulation 03.01.
Wiring and Installation Instructions PRM 5 4.3.
Wiring and Installation Instructions PRM 5 The parity bits, the start and end characters, the LRC and the zero bits at the edge are generated automatically by the reader. On the one hand, they do not require space in the transponders (therefore we can encode 16 digits for the user), on the other hand this means that there will be a problem if one of the fields is missing.
Wiring and Installation Instructions PRM 5 Calculation of the parity: LRC = 80h OR [52h Å 45h Å 30h Å 43h Å 35h Å 35h Å 37h Å 30h] = E3h (‘‘Å’’ means Exlusive-OR) 5 Installation 5.1 PRM 5 Reader The PRM 5 reader can be surface mounted using an AP 5 spacer, or flush mounted direct to an European round style back box. Flush mounted with FM5 bezel 03.01.
Wiring and Installation Instructions PRM 5 6 Installation 6.1 Indicators Function of LED’s and beeper (except Supervised F2F protocol): Yellow LED: Reader is operational. Momentarily flashes during the reading of a card. Green LED, red LED, beeper: The function of these indicators is dependant on how they are connected to the controller. 6.2 03.01.
Wiring and Installation Instructions PRM 5 6.3 ) Wiegand/Data/Clock Note: For all interfaces except RS 232/485 the pull-ups must be connected to the clock and data lines. 7 Appendix 7.1 Supervised F2F It is possible to switch between native and compatible mode using special programming cards. 03.01.