PRM15 Wiring & Installation Instructions V10/09/08
PRM15 © Copyright 2008 by deister electronic GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes.
PRM15 Contents 1. General.......................................................................4 2. Technical Data............................................................5 3. Mechanical Dimensions..............................................6 3.1 Rear view (opened housing).................................................................................7 4. Wiring Diagram..........................................................8 4.1 2-Wire Wiegand.....................................................
PRM15 1. General The PRM15 is a compact proximity reader with integrated antenna from the deister electronic HF product family. It has been designed for reading distances as used in door control applications.
PRM15 2. Technical Data Dimensions (mm): 300 x 300 x 30 mm Housing material: ABS Protection class: IP 54 (according to IEC 529) Electrical protection: Reverse polarity diode protection on power lines; high-speed transient voltage suppressor diodes on data lines Temperature range: +5 ...+60 °C (indoor use, non-condensing) -25 ...+60 °C (available for outdoor use) Power supply: 9...
PRM15 3. Mechanical Dimensions All dimension in mm.
PRM15 3.1 Rear view (opened housing) The switches S1, S2 and S3 will be explained in 7.1 “Easy Trim Function”.
PRM15 4. Wiring Diagram 4.1 2-Wire Wiegand 4.2 Magstripe Emulation/Data/Clock 4.
PRM15 5. Interfaces 5.1 Wiegand / Data/Clock max. 30 V max. 20 mA Pull-up resistor see above 5.2 Magstripe Emulation Pull-up resistor see above Pull-up resistor see above Pull-up resistor see above 5.3 Indicators 5 Function of LEDs and Beeper: Yellow LED: Reader is ready to operate. LED momentarily flashes during the reading of a card. Green LED, red LED, Beeper: The function of these indicators depends on how they are connected to the host system.
PRM15 5.4 RS485 Interface Most RS485 buses require termination resistors across the conductor pair. The need for termination has to be checked for each installation. Especially for high data rates, steep edges or long cables termination resistors are mandatory. Only both ends of the main cable, i.e. at the first and the last device, require termination resistors, additional resistors excessively load the drivers.
PRM15 6. Communications Protocol 6.1 Wiegand Standard 6.2 Data/Clock 6.
PRM15 6.4 Tamper Switch By connecting the terminal to further electrical devices it is possible for the user to control if the cover of the PRM15 housing is open or closed. The installation can be integrated into an alarm system in order to provide protection against tampering.
PRM15 6.
PRM15 The parity bits, the start and end characters, the LRC and the zero bits at the edge are generated automatically by the reader. On the one hand, they do not require space in the transponders (therefore we can encode 16 digits for the user), on the other hand this means that there will be a problem if one of the fields is missing.
PRM15 Calculation of the parity: LRC = 80h OR [52h Å 45h Å 30h Å 43h Å 35h Å 35h Å 37h Å 30h] = E3h (“Å” means Exlusive-OR) V10/09/08 rf_prm15_wi_en 15
PRM15 7. Installation 7.1 Easy Trim Function (ETF) This function allows adjustment of the reader to its environmental conditions. The ETF is a semiautomatic function for trimming the reader to its best performance. The ETF starts after switch S1 has been pressed (see 3.1 “Rear View”, switches). In this mode only one of the three LEDs is blinking. The individual meaning of each LED is as follows: Red LED: The rotatable switch (S2) must be turned to the right.
PRM15 7.3 Mounting considerations In order to ensure proper operation and an optimum reading/writing range take the following precautions: 1.) Mount all readers before tuning any of the readers. 2.) Ensure that the back-to-back distance is at least 50 cm. 3.) Ensure that the vertical separation distance is at least 50 cm. A narrower vertical separation gap may be used in case simultaneous reading/writing of a transponder by two readers is acceptable.
PRM15 8. Regulatory notices 8.1 Europe Hereby, deister electronic GmbH declares, that this equipment - if used according to the instructions - is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EG. A full declaration of conformity can be requested at: info@deister-gmbh.de Approved for use in all European countries. 8.
PRM15 Notes: V10/09/08 rf_prm15_wi_en 19
deister worldwide Germany: deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Tel.: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 info@deister-gmbh.de www.deister.com Belgium & Luxembourg: deister electronic office Business Park E 19 Battelsesteenweg 455/A 2800 Mechelen Tel.: +32 (0) 15 - 28 09 68 Fax: +32 (0) 15 - 28 09 71 info@benelux.deister.com France: deister electronic france 101 rue Pierre Semard 92320 Chatillon Tel.