Export MODULENS O EN ® Oil-fired condensing boilers AFC 18 - AFC 24 - AFC 30 User Guide 300026440-05
Contents 1 Safety instructions .....................................................................................4 1.1 Safety instructions ...............................................4 1.2 Recommendations ................................................5 1.3 Liabilities ...............................................................5 1.3.1 1.3.2 1.3.3 2 About this manual ......................................................................................8 2.1 Symbols used ..................
Contents 5.3.6 5.3.7 6 7 8 9 10 2 Selecting a timer programme ................................23 Customising a timer programme ...........................24 5.4 Installation shutdown .........................................26 5.5 Antifreeze protection ..........................................26 Checking and maintenance .....................................................................28 6.1 General instructions ...........................................28 6.2 Periodic checks ..........
3 15/07/2015 - 300026440-05
AFC 18 - AFC 24 - AFC 30 1. Safety instructions 1 Safety instructions 1.1 Safety instructions DANGER This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
AFC 18 - AFC 24 - AFC 30 1. Safety instructions CAUTION 4 Do not neglect to service the appliance. For completely safe and optimum operation, you must have your boiler regularly serviced by an approved installer. 4 Before any work, switch off the mains supply to the appliance. 4 Avoid direct contact with the flame viewport. 1.2 Recommendations WARNING Only qualified professionals are authorised to work on the appliance and the installation.
1. Safety instructions AFC 18 - AFC 24 - AFC 30 In the interest of customers, we are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice. Our liability as the manufacturer may not be invoked in the following cases: 4 Failure to abide by the instructions on using the appliance. 4 Faulty or insufficient maintenance of the appliance. 4 Failure to abide by the instructions on installing the appliance.
1.
2. About this manual AFC 18 - AFC 24 - AFC 30 2 About this manual 2.1 Symbols used 2.1.1. Symbols used in the manual In these instructions, various danger levels are employed to draw the user’s attention to particular information. In so doing, we wish to safeguard the user’s safety, highlight hazards and guarantee correct operation of the appliance. DANGER Risk of a dangerous situation causing serious physical injury. WARNING Risk of a dangerous situation causing slight physical injury.
2. About this manual 1 AFC 18 - AFC 24 - AFC 30 Caution: danger, live parts. Disconnect the mains power prior to any operations. 2 M002628-A 2.
AFC 18 - AFC 24 - AFC 30 3. Technical specifications 3 Technical specifications 3.1 Certifications CE identification no CE : 1312 CN 5691 Type of connection Chimney: B23, B23P Flue gas outlet: C13(x), C33(x), C93(x) 3.2 Technical specifications 3.2.1. Boiler specifications Test conditions: 4 CO2 of 12% at min output and 13% at max output with oil. 4 Maximum operating pressure - Primary circuit (heating water): 3 bar (0.
3. Technical specifications AFC 18 - AFC 24 - AFC 30 Boiler LHV efficiency AFC 18 AFC 24 AFC 30 Minimum power Full power Minimum power Full power Minimum power Full power 100 % Nominal output (Pn) at 80/60°C % 96.3 97.2 96.4 97.1 95.9 97.4 Flue gas temperature °C <60 <70 <60 <70 <65 <75 100 % Nominal output (Pn) at 50/30°C % 101.5 102.1 101.4 102 101.1 101.6 Flue gas temperature °C <40 <45 <40 <45 <45 <50 100 % Nominal output (Pn) at 40/30°C % 102.9 103.
AFC 18 - AFC 24 - AFC 30 4. Product description 4 Product description 4.1 General description Floor-standing condensing oil boiler 4 Heating only (Optional domestic hot water production in combination with a DHW tank). 4 High efficiency heating. 4 Low pollutant emissions. 4 Modulating oil burner preassembled and preset. 4 Stainless steel heating body. 4 Top of the range electronic DIEMATIC iSystem control panel. 4 Flue gas discharge via a forced flue or chimney type connection. 4.
4. Product description 4.3 AFC 18 - AFC 24 - AFC 30 Control panel Description of the keys A000866-A 4.3.1.
AFC 18 - AFC 24 - AFC 30 4. Product description 4.3.2.
4.
AFC 18 - AFC 24 - AFC 30 4. Product description n System pressure bar 0 2 4 6 8 10 12 14 16 18 20 22 24 bar r j l M C002708-A p b AUTO x c g m t STD Pressure indicator: The symbol is displayed when a water pressure sensor is connected. 4 Flashing symbol: The water pressure is insufficient. 4 Steady symbol: The water pressure is sufficient.
4. Product description AFC 18 - AFC 24 - AFC 30 4.3.3. 0 4 6 8 10 12 14 16 #MEASURES #CHOICE TIME PROG. #TIME PROGRAM #SETTING c #TIME .DAY r v bar 2 18 20 22 24 a 1 2 1 2 p b AUTO x c g m ( ' r j Browsing in the menus 1. To select the desired menu, turn the rotary button. 2. To access the menu, press the rotary button. To go back to the previous display, press the key j. L t STD C002220-B-04 0 2 4 6 8 10 12 14 16 18 20 CURRENT PROG.B CURRENT PROG.
AFC 18 - AFC 24 - AFC 30 5. Operating the appliance 5 Operating the appliance 5.1 Putting the appliance into operation 1. Turn on the boiler using the on/off switch. 8 20 22 24 0 l C003159-A 0 v bar c 1 2 1 2 2 4 6 8 10 12 14 16 18 20 22 2. The first time the boiler is powered up, the LANGUAGE menu is displayed. Select the desired language by turning the rotary button. 3. To confirm, press the rotary button. 4.
5. Operating the appliance AFC 18 - AFC 24 - AFC 30 User level - #MEASURES Menu Parameter Description Unit Room temperature of circuit C °C BOILER TEMP Water temperature in the boiler °C PRESSURE Water pressure in the installation bar (MPa) OIL PRESSURE Injection nozzle oil pressure bar (MPa) Water temperature in the DHW tank °C Instant hot water temperature °C Water temperature in the storage tank °C ROOMTEMP.C (1) WATER TEMP. (1) (1) TEMP DHW INST STOR.TANK.TEMP (1) SWIMMING P.
AFC 18 - AFC 24 - AFC 30 5.3 5. Operating the appliance Changing the settings 5.3.1. Setting the set point temperatures To set the various heating, DHW and swimming pool temperatures, proceed as follows: 1. Press the C key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j. 4. To modify the parameter, turn the rotary button. 5. To confirm, press the rotary button.
5. Operating the appliance AFC 18 - AFC 24 - AFC 30 5.3.2. Selecting the operating mode To select an operating mode, proceed as follows: 1. Press the MODE key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j. 4. To modify the parameter, turn the rotary button. 5. To confirm, press the rotary button. MODE To cancel, press key h.
AFC 18 - AFC 24 - AFC 30 5. Operating the appliance 5.3.3. Forcing domestic hot water production To force domestic hot water production, proceed as follows: 1. Press the r key. 2. To select the desired parameter, turn the rotary button. 3. To modify the parameter, press the rotary button. To go back to the previous display, press the key j. 4. To modify the parameter, turn the rotary button. 5. To confirm, press the rotary button. MODE To cancel, press key h.
AFC 18 - AFC 24 - AFC 30 5. Operating the appliance 5.3.5. Setting the time and date 1. To access user level: Press the > key. 0 2 4 6 8 10 12 14 16 18 20 22 24 2. Select the menu #TIME .DAY. SUNDAY 11:45 v bar c Turn the rotary button to scroll through the menus or modify a value. 4 Press the rotary button to access the selected menu or confirm a value modification. ¼For a detailed explanation of menu browsing, refer to the chapter: "Browsing in the menus", page 17.
5. Operating the appliance AFC 18 - AFC 24 - AFC 30 User level - #CHOICE TIME PROG. Menu Parameter Adjustment range Description CURRENT PROG.A P1 / P2 / P3 / P4 Comfort programme activated (Circuit A) CURRENT PROG.B P1 / P2 / P3 / P4 Comfort programme activated (Circuit B) CURRENT PROG.C P1 / P2 / P3 / P4 Comfort programme activated (Circuit C) 5.3.7. Customising a timer programme 1. To access user level: Press the > key. 0 2 4 6 8 10 12 14 16 18 20 22 2.
5. Operating the appliance 0 v bar c 1 2 1 2 2 4 6 8 10 12 14 AFC 18 - AFC 24 - AFC 30 16 18 PROG P2 C Mo Tu We Th Fr "Select the days to program" r p b AUTO x c g m ( ' r 20 Sa j 22 24 a Su L t STD 6. b: Day selection Press key b / v until the symbol b is displayed. Turn the rotary button to the right to select the day(s) desired. v: Cancelling the day selection Press key b / v until the symbol v is displayed.
5. Operating the appliance AFC 18 - AFC 24 - AFC 30 User level - #TIME PROGRAM Menu Day Comfort periods / Filling enabled: P1 P2 _______________ P3 _______________ P4 _______________ _______________ TIME PROG.DHW Monday Tuesday Wednesday Thursday Friday Saturday Sunday TIME PROG.AUX Monday Tuesday Wednesday Thursday Friday Saturday Sunday 5.4 Installation shutdown If the central heating system is not used for a long period, we recommend switching the boiler off. 4 Switch the On/Off switch to Off.
5. Operating the appliance AFC 18 - AFC 24 - AFC 30 CAUTION 4 4 The antifreeze protection does not function if the appliance is switched off. The integrated protection system only protects the boiler, not the installation. To protect the installation, set the appliance to HOLIDAYS mode. The HOLIDAYS mode protects: 4 The installation if the outside temperature is lower than 3°C (factory setting).
AFC 18 - AFC 24 - AFC 30 6. Checking and maintenance 6 Checking and maintenance 6.1 General instructions The boiler does not require a lot of maintenance. Nevertheless, we recommend having the boiler inspected and serviced at regular intervals. 4 Maintenance and cleaning of the boiler must be carried out at least once a year by a qualified technician. 4 Have the flues swept at least once a year or more, depending on the regulations in force in your country.
AFC 18 - AFC 24 - AFC 30 6. Checking and maintenance 4 Carry out a visual check for the presence of any water leaks. T001507-B 4 Open and close the radiator valves several times a year (this prevents the valves from seizing up). 4 Clean the outside of the boiler using a damp cloth and a light detergent. 1 2 CAUTION 3 4 T000181-B 6.3 Only a qualified professional is authorised to clean the inside of the boiler. Filling the system 1.
AFC 18 - AFC 24 - AFC 30 6. Checking and maintenance 5. To add water, use the filling pipe with a valve fitting, a cloth and a venting spanner. C003835-A 6. Connect the filling tube to a (cold) water tap. T000846-A 7. Eliminate the air from the filling tube. Slowly fill the tube with water. Hold the end of the tube up, above a bucket. Turn off the tap as soon as water runs out of the pipe. C003836-A 8. Unscrew the plug from the filling/draw-off valve.
AFC 18 - AFC 24 - AFC 30 6. Checking and maintenance 9. Attach the tube to the filling/draw-off valve. Firmly tighten the nut on the filling tube. 10.Open the filling/draw-off valve on the heating system. 11.Open the running water tap. 12.Check the water pressure in the installation shown on the control panel display. 13.Close the water tap when the water pressure reaches 2 bar. C003837-A 14.Close the filling/draw-off valve on the heating system.
AFC 18 - AFC 24 - AFC 30 6. Checking and maintenance 6. Bleed the radiators. Start with the lower floors. 5 3 4 1 2 T000854-A 7. Open the bleed connection using the bleed key provided whilst keeping a rag pressed against the connection. T000217-A 8. Wait until water comes out of the bleed valve and then close the bleed connection. CAUTION The water may still be hot. 9. Switch on the boiler. 10.Check whether the pressure in the installation is still sufficient.
6. Checking and maintenance AFC 18 - AFC 24 - AFC 30 11.Set the heating set point. 6.5 Draining the installation It may become necessary to empty the water from the heating system when the radiators have to be replaced, should there be a major water leak or a risk of frost. To do this, proceed as follows: 1. Open the valves on all radiators connected to the heating system. 1 2 3 4 T000181-B 2. Switch off the boiler electrical power supply. 3. Wait around 10 minutes until the radiators are cold.
AFC 18 - AFC 24 - AFC 30 7. Troubleshooting 7 Troubleshooting 7.1 Anti-hunting When the boiler is in Anti-short-cycle operating mode, the symbol ? flashes. 1. Press the "?" key. The message Operation assured when the restart temperature will be reached is displayed. This message is not an error message but an item of information. 7.2 Messages (Code type Bxx or Mxx) In the case of failure, the control panel displays a message and a corresponding code. 1. Make a note of the code displayed.
7. Troubleshooting AFC 18 - AFC 24 - AFC 30 Code Messages Description B04 BL.SMOKE.TEMP The maximum flue gas 4 temperature has been exceeded. If this message is generated 5 times in 24 hours, the boiler locks down in L31. Checking / solution B10 B11 BL.SC.IN.OPEN The BL inlet on the PCU PCB terminal block is open Contact the professional who takes care of maintenance of the appliance.
AFC 18 - AFC 24 - AFC 30 7. Troubleshooting Code Messages Description B28 BL.BAD.CONFIG An HL tank is detected whilst the 4 boiler cannot control it. This message disappears after 4 10 seconds if the boiler can control the HL tank Checking / solution Wait for 10 seconds to see whether the error persists Contact the professional who takes care of maintenance of the appliance B29 to B34 BL.
7.
AFC 18 - AFC 24 - AFC 30 7. Troubleshooting Code Faults Cause of the fault Description Checking / solution L30 DEF.FLUE GAS PRESSURE PCU The flue gas pressure switch opened 5 times in 24 hours. L31 DEF.SMOKE.TEMP PCU The maximal smoked temperature 4 is exceeded of 5 times in 24 hours. L32 DEF.OUTLET S.
7. Troubleshooting AFC 18 - AFC 24 - AFC 30 Code Faults Cause of the fault Description Checking / solution D05 OUTSI.S.FAIL. SCU Outside temperature sensor fault Bad connection Sensor fault Remarks: The boiler operates on BOILER 4 Contact the professional who takes care of MAX temperature. maintenance of the appliance The valve setting is no longer ensured but monitoring the maximum temperature of the circuit after the valve is ensured. Valves may be manually operated.
AFC 18 - AFC 24 - AFC 30 7. Troubleshooting Code Faults Cause of the fault Description Checking / solution D27 PCU COM.FAIL SCU Communication failure between the SCU and PCU PCBs D37 TA-S SHORT-CIR SCU 4 Contact the professional who takes care of maintenance of the appliance The Titan Active System® is short-circuited 4 Contact the professional who takes care of maintenance of the appliance Remarks: Domestic hot water production has stopped but can nonetheless be restarted using key r.
AFC 18 - AFC 24 - AFC 30 8. Energy savings 8 Energy savings 8.1 Energy-saving advice 4 Keep the room in which the boiler is installed well ventilated. 4 Do not block ventilation outlets. 4 Do not cover the radiators. Do not hang curtains in front of the radiators. 4 Install reflective panels behind the radiators to prevent heat losses. 4 Insulate the pipes in rooms that are not heated (cellars and lofts). 4 Close the radiators in rooms not in use. 4 Do not run hot (or cold) water pointlessly.
9. Warranty AFC 18 - AFC 24 - AFC 30 9 Warranty 9.1 General You have just purchased one of our appliances and we thank you for the trust you have placed in our products. Please note that your appliance will provide good service for a longer period of time if it is regularly checked and maintained. Your installer and our customer support network are at your disposal at all times. 9.
en Appendix Information on the ecodesign and energy labelling directives
Contents Contents 1 Specific information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2 Ecodesign Directive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Specific information 1 Specific information 1.1 Recommendations Note Only qualified persons are authorised to assemble, install and maintain the installation. 1.2 Ecodesign Directive This product conforms to the requirements of European Directive 2009/125/EC on the ecodesign of energy-related products. 1.3 Tab.
1 Specific information 1.4 Circulation pump Note The benchmark for the most efficient circulators is EEI ≤ 0.20. 1.5 Fig.1 Disposal and Recycling Recycling Warning Removal and disposal of the boiler must be carried out by a quali fied installer in accordance with local and national regulations. MW-3000179-03 Fig.2 Proceed as follows to dismantle the boiler: Cutting the mains supply MW-0000149-1 1.6 Tab.2 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Cut the electrical power to the boiler.
1 Specific information 1.8 Fig.3 Package fiche - Boilers Package fiche for boilers indicating the space heating energy efficiency of the package Seasonal space heating energy efficiency of boiler 1 ‘I’ Temperature control % 2 from fiche of temperature control Class I = 1%, Class II = 2%, Class III = 1.5%, Class IV = 2%, Class V = 3%, Class VI = 4%, Class VII = 3.5%, Class VIII = 5% Supplementary boiler Seasonal space heating energy efficiency (in %) + % 3 from fiche of boiler ( - ‘I’ ) x 0.
1 Specific information II III IV Tab.4 The factor for weighting the heat output of preferential and supple mentary heaters of a package as set out in the following table. The value of the mathematical expression: 294/(11 · Prated), whereby ‘Prated’ is related to the preferential space heater. The value of the mathematical expression 115/(11 · Prated), whereby ‘Prated’ is related to the preferential space heater.
DE DIETRICH THERMIQUE S.A.S +49 (0)25 72 / 9161-0 +49 (0)25 72 / 9161-102 info@remeha.de DE DIETRICH THERMIQUE Iberia S.L.U. www.dedietrich-calefaccion.es ES C/Salvador Espriu, 11 08908 L’HOSPITALET de LLOBREGAT +34 935 475 850 info@dedietrich-calefaccion.es 129164, Россия, г. Москва Зубарев переулок, д. 15/1 Бизнес-центр «Чайка Плаза», офис 309 +7 (495) 221-31-51 info@dedietrich.ru DE DIETRICH SERVICE www.dedietrich-heiztechnik.com Freecall 0800 / 201608 IT BDR Thermea (Czech republic) s.r.o www.