Contents: 1 DESCRIPTION ................................................................................................................................ 4 1.1 1.2 1.3 1.4 1.5 1.6 2 USER INTERFACE .......................................................................................................................... 5 2.1 2.2 2.3 2.4 2.5 2.6 3 A DESCRIPTION OF THE XTEND MAX UNIVERSAL STICK SCANNER ................................................... 4 SWITCH ON THE SCANNER .............................
10.1 10.2 10.3 THE READING DISTANCE IS TOO SHORT ................................................................................... 18 THE SCANNER DOES NOT READ THE TRANSPONDER ................................................................. 18 THE SCANNER DOES NOT WORK ............................................................................................. 18 11 ADVANCED MODE PACK ............................................................................................................
1 Description 1.1 A description of the XTend Max universal stick scanner Datamars’ XTend Max is a portable, universal stick scanner used for scanning companion animal microchips. It reads all prevalent microchips available in North America. It is ideal for scanning aggressive, stressed or feral animals without direct contact by placing added distance between you and the animal for added safety.
1.4 Scanning a microchip Hold the XTend Max in close proximity to the animal to be scanned, and then press the red “On” button located on the control panel in order to start scanning. You can also press the grey button at the base of the stick to begin scanning. XTend Max will give an audible sound and you will hear a “beep* when the scanner successfully detects a microchip. To cancel or stop scanning, press the red “On” button located on the control panel, or the grey button at the base of the stick 1.
2 User interface 2.1 Keypad SELECT LEFT button SELECT RIGHT button ON button 2.2 Stick antenna STICK button XTend Max Reader User Manual – v. 0.
2.3 ON button There is more than one possibility to use the ON button, in fact with him you are able to turn on the XTend Max scanner, and when the scanner is turned on you have the possibility to start and stop a reading session. Moreover when you are surfing in the menu the ON button is used to select and confirm the various available settings, the settings are described in later chapters of this manual. 2.
3 Menu management A number of different settings can be customized to the user’s preference. Press the SELECT LEFT button from the scanner’s control panel in order to open the settings menu. Press the SELECT RIGHT button from the scanner’s control panel in order to exit the settings menu. 3.1 Settings Setup Icon Continue to press SELECT LEFT button until the green selection is on the setup icon, and then press the ON button in the center of the control panel to confirm your selection.
3.3 Date and Time Date & Time Icon The Date & Time setting allows you to adjust the date and the time, as well as the date format. Press the left navigation button from scanner’s control panel to open the menu. Continue to press the left navigation button until the green selection is on the Date & Time icon, and then press the red “On” button in the center of the control panel to confirm your selection.
3.4.1 Backlight Timeout The Backlight Timeout defines the maximum amount of time that the display remains on while the unit is inactive. The following values are available: Default: Maximum: Minimum: 3.4.2 40 sec. 60 sec. (1 min.) 1 sec. Brightness Brightness defines the level of the brightness of the display.
3.5.3 Start-Up Sound Start-up sound enables or disables the audio signal given when the scanner is powered on. When the feature is set to OFF, the sound is disabled and will not be heard. When it is ON, the sound is enabled and will be heard. 3.5.4 Shut-Down Sound Shut-down sound enables or disables the audio signal given when the scanner is powered down. When the feature is set to OFF, the sound is disabled and will not be heard. When it is ON, the sound is enabled and will be heard. 3.5.
4 Connect your XTend Max to a PC 4.1 Basic Mode When the scanner is configured as basic mode you are able to use the PC for three functionality, the first is for recharge the battery from the scanner; and with the second you are able to connect it to the Softmax in order to have the possibility to update the version of the firmware, or for upgrade the level of the reader with charging new functionality.
5 Battery management Xtend Max can be charged in two ways. You can connect the USB cable to the wall-mounted adapter or you can connect the USB cable to a USB port on your Windows PC. When the Xtend Max Scanner is in charging mode, the scanner functions are disabled. 5.
Indicates unit is plugged into the wall XTend Max Reader User Manual – v. 0.
6 Take care of your scanner Ensure that the scanner does not get damaged. Do not drop it onto a hard surface or subject it to wet conditions. If the outer casing of the scanner becomes soiled, it can be cleaned with a damp cloth. First ensure that it is not connected to the charger. If for any reason the scanner is not working, please do not attempt to repair it, but return it for repair to your local dealer.
7 Specifications 7.
8 Softmax XTend Max Reader User Manual – v. 0.
9 Information to user 9.1 FCC Part 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules.
Do you have a problem identifying an animal? 9.3 The reading distance is too short The maximum reading distance is obtained with the transponder (tag) perpendicular to the antenna and aimed at the center of the antenna coil. If the tag is implanted into an animal its orientation may not be optimal and therefore the reading distance may be reduced. You might be close to a source of electromagnetic disturbances like video or TV. Move a few meters away and try again. Do not use the scanner on a steel table.
10 Advanced Mode Pack XTend Max Reader User Manual – v. 0.
11 Bluetooth In order to use the functionality explained below you have to be sure that your scanner has the Bluetooth pack. The pack is composed about a physical Bluetooth module into the scanner and equipped with a dedicated firmware. 11.1 Turn ON Bluetooth module Press the right Select button in order to open the action menu, move the left Select button as long as you are with the cursor over the Bluetooth icon.
Return to the start page of the dialog window with pressing the Device tap, as shown in the following picture: Double check that the Xtend Max Scanner is switched ON and the Bluetooth enabled, and then press the Add… button on the bottom of the dialog window. 11.
After the selection of the device you have to be pressed the Next > button, as shown in the following picture: Select the option: Let me choose my own passkey and the password is 0. This is for all Datamars scanners the same, just one 0 characters, and then press the Next > button to continue, as shown in the following picture: The connecting window will be appear, sometimes is it possible that this operation do not go at the first attempt.
11.5 Bluetooth COM Port The installation of the Bluetooth module will be creating on the PC two new COM Ports, in order to see this new ports you have to be selected the COM Ports tab. You find listed all port for your new Bluetooth device, one is an outgoing and the other is an incoming port, as shown in the following picture: You have to be selected the outgoing COM when you will use the Xtend Max in the server mode.
12 Certifications 12.1 European directives Datamars SA, Via ai Prati, CH-6930 Bedano declares, under its own responsibility, that the product Xtend Max is in accordance with the following standards: ETSI EN 300 330-1 / ETSI EN 300 330-2 Electromagnetic compatibility and Radio spectrum matters (ERM) - Short Range Devices. ETSI EN 301 489-1 / ETSI EN 301 489-3 Electromagnetic compatibility (EMC) standard for radio equipment and services.
13 End of life 13.1 Disassembly Instructions for Xtend Max scanner Product Name / Model Description Extend Max / Any models Universal portable scanner Only authorized recyclers are permitted to use these disassembly instructions. Any attempted disassembly by a user or unauthorized party will void the product warranty and may irreparably damage the product. 13.2 13.