3 1 Acknowledge the license request Wait for the installation end. Select Finish.
USE AND FUNCTIONING 3 Select the DLdcu package Click on Configure Select JOYA Configuration then click on the Launch button DLdcu application will start.
DATALOGIC JOYA™ X2 3 1 From the File menu select Clone from file, browse up to the previously created JOYAa.cfg file (see Datalogic Configuration Utility chapter). Close the application. Confirm the pop-up request by clicking on the Yes button. This procedure is required to create a JOYA™ X2 profile in the DLdcu.AVA package. The existing JOYA profile refers to an incompatible device. 3.5 AVALANCHE PACKAGE BUILDER 3.5.
USE AND FUNCTIONING • • • • 3 Retrievable Files. These are files you want to retrieve from the JOYA™ X2 and copy to the Avalanche Agent. Retrievable files are supported in the 3x Enabler. Post Install File. This feature allows you to create script files using the Package Builder. Uninstall Command. This is an executable that may be added to perform specific uninstall instructions, such as the removal of registry settings. Custom EULA.
DATALOGIC JOYA™ X2 3 1 Full description of this tool is beyond the scope of this document; a detailed help is embedded in the program. Nevertheless a specific usage description, involving the Avalanche application, will follow; since it’s not documented elsewhere. In order to use the DLdcu, your computer must have the Microsoft Active Sync or Windows Mobile Device Center installed. 3.6.
USE AND FUNCTIONING 3 Once configuration is loaded it can be edited then reloaded to the device and/or saved. Select Save as from the File menu, enter JOYA as filename; program will add automatically the CFG extension. Use this file to modify the DLdcu.AVA package as stated above. 3.7 USING THE STYLUS (AVAILABLE ONLY ON JOYA™ X2 PLUS) The stylus selects items and enters information. The stylus functions like a mouse. Double Tap: Touch the screen twice with the stylus to open items and select options.
DATALOGIC JOYA™ X2 3 1 To capture data first of all select the Decoding icon on the Control Panel and open the applet. To configure and enable data capture parameters refer to par. 3.11. 3.8.1 Imager Data Capture The device captures a picture of the entire bar code. The omnidirectional scanning does not require that the operator orient the bar code to align with the scan pattern. To read a 1D or 2D code, simply point the JOYA™ X2 onto the code and press the “Up” key.
USE AND FUNCTIONING 3 45
3 1 DATALOGIC JOYA™ X2 The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the device is closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit. Symbologies with larger bars or elements (mil size) should be read farther from the unit. (See par. 5.1 for further details).
USE AND FUNCTIONING 3.9 3 DESCRIPTION OF THE KEYS The Datalogic JOYA™ X2 provides a 6-key keyboard. The following image shows this keyboard. Main Keys Function + ”: it corresponds to ArrowUp Key. Key “ - ”: it corresponds to ArrowDown Key. Key “ Key “ Left Key “ Right ”: it corresponds to F1 (Function1) Key. ”: it corresponds to F2 (Function2) Key. = ”: it corresponds to ESC Key. Key “ e ” : it corresponds to ENTER Key.
DATALOGIC JOYA™ X2 3 1 3.9.1 Resetting the JOYA™ X2 There are three reset methods for the JOYA™ X2 A “warm boot” terminates an unresponsive application and clears the working RAM, but preserves both the file system and the registry. A “cold boot” forces all applications to close and clears working RAM and files not resident on the persistent flash memory. Registry is restored from persistent memory if available or returned to factory default. A “clean boot” restore the JOYA™ X2 to factory default.
USE AND FUNCTIONING 3 Clean boot may require a considerable amount of time, even a few minutes.
DATALOGIC JOYA™ X2 3 1 3.10 STATUS INDICATORS 3.10.1 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS DESCRIPTION Time and Battery Icons It displays the time. They are representative of different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. It indicates that the battery is charging.
USE AND FUNCTIONING 3 Bluetooth Status Icon It indicates the Bluetooth status: disabled, enabled not connected, enabled connected. Scanner Icon Give access to the scanner control tools. 3.11 DATA CAPTURE CONFIGURATION Decoding can be accessed from the Control Panel. There are two sections in the Decoding control panel, each containing additional pages. There are seven General Configuration pages and multiple 1D/2D Barcode symbology pages. 3.11.
3 1 DATALOGIC JOYA™ X2 NOTIFICATION From the Decoding menu, tap Configure > General > Notification. Use to set volume, tone, duration, and number of various types of beeps. GOOD READ From the Decoding menu, tap Configure > General > Good Read. Select from Automatic good read, Enable Green Spot, enable LED and Timeout.
USE AND FUNCTIONING 3 FORMATTING From the Decoding menu, tap Configure > General > Formatting. Select from Label Prefix, Suffix and data separator. In the Edit window enter the required value according to the previous choice. GENERAL OPTIONS From the Decoding menu, tap Configure > General > General Options. Select from Label Programming Enable, Symbology IDs, and Group Separator.
3 1 DATALOGIC JOYA™ X2 DECODING OPTIONS From the Decoding menu, tap Configure > General > Decoding Options. Use to customize identification of different barcode symbology. IMAGER OPTIONS From the Decoding menu, tap Configure > General > Imager Options. Modify the Imager related feature accordig to your needs.
USE AND FUNCTIONING 3 KEYBOARD WEDGE From the Decoding menu, tap Configure > General > Keyboard Wedge. Select Bar code to enable the wedge mode. 1D BARCODE SYMBOLOGY PAGES Use the drop-down menus from Configure > 1D Barcode, or tap the left and right arrow keys to navigate the different pages of the 1D barcode symbology pages.
3 1 DATALOGIC JOYA™ X2 Each barcode symbology opens to its own page, as shown in the figure below. Refer to the sample symbology control panels for examples of the types of fields and options you can modify. Example: Code 39: Enable, Min/Max Lengths = 2/50, not Enable Checksum, not Send Checksum, Full ASCII Conversion disabled.
USE AND FUNCTIONING 3 2D BARCODE SYMBOLOGY PAGES Use the drop-down menus from Configure > 2D Barcode, or tap the left and right arrow keys to navigate the different pages of the 2D barcode symbology pages. Each barcode symbology opens to its own page, as shown in the figure below. Refer to the sample symbology control panels for examples of the types of fields and options you can modify. Example: PDF417: Enabled, Min/Max Lengths = 1/2710.
3 1 DATALOGIC JOYA™ X2 DECODING SETTINGS Select from the Decoding Properties Settings menu to restore previous configurations and/or other available default settings. Choose from: • Factory Defaults • Minimum Settings • Maximum Settings • Save (New Settings) • Revert to Saved Settings The settings are saved when you tap OK.
USE AND FUNCTIONING 3 DECODED DATA Clicking on the barcode icon on the taskbar opens the decoded data applet. Press the “+” key and scan a code, Data and barcode type will be displayed.
3 1 DATALOGIC JOYA™ X2 3.12 CONTROL PANEL From the Desktop, double tap on the "My Device" icon and then double tap on the "Control Panel" icon to open the control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel. Applet programs are displayed as icons; one icon corresponds to each applet. 3.12.1 Registry The PERSISTENT REGISTRY applet provides management of Windows CE 6.0 registry.
USE AND FUNCTIONING 3 3.12.2 Using Summit Radio Card Utility The JOYA Summit WiFi card provides a useful client utility suitable for radio configuration and site survey purposes. 3.12.
3 1 DATALOGIC JOYA™ X2 3.12.4 Summit Radio Card : Main screen The following picture shows the screen when Summit Client is started The Active Profile window displays the current profile and lets user to change it. The Disable Radio button turns off the radio card; after deactivation the same button changes to Enable Radio so the radio can be reactivated. To close the application, press the close button at upper-right corner of window.
USE AND FUNCTIONING 3 3.12.5 Summit Radio Card : Profile screen Radio card is managed through radio profiles. User can rename, delete, create and save any changes by the Rename, Delete, New and Commit buttons. The name chosen for the profile is also his identifier. Profile is defined by a set of parameter that user can customize. The following is a simple profile for testing.
3 1 DATALOGIC JOYA™ X2 User can read current profile name, client device name, IP address and MAC address. The Access Point to which the terminal is currently associated t is specified by name, IP address and MAC address. User can also read the signal strength (dBm), the transmission power percentage, the WiFi channel, the rate (Mbps).
USE AND FUNCTIONING 3 3.12.7 Summit Radio Card : Diagnostic screen This screen allows user to interact with radio card to perform simple and useful functionalities. The (Re)connect button disables and re-connects radio card. The Release/Renew button releases and renews the radio interface IP address. In order to test the radio link, user can ping the associated access point by pressing the Start Ping button.
3 1 DATALOGIC JOYA™ X2 The Diagnostic button displays the radio configuration and dumps available profiles Site Survey functionality is not available. 3.12.8 Summit Radio Card : Global Settings screen There are many other parameters used to configure the radio card and they do not depend on used profile, nevertheless for good working it’s recommended do not change the default values.
USE AND FUNCTIONING 3 3.13 STYLUS CALIBRATION You might need to recalibrate the touch screen (i.e. when you attempt to select one item with the stylus, another item is erroneously selected). To recalibrate the touch screen, complete the following steps: 1. Select Start > Settings > Control Panel > Stylus to open the Stylus Properties dialog as shown in Figure 1. 2. Select the Double-Tap tab to adjust the sensitivity, if needed or desired. 3. Select the Calibration tab to open the Calibration application.
DATALOGIC JOYA™ X2 3 1 3.14 WINDOWS CONNECTIONS To connect the Datalogic JOYA™ X2 to another device (i.e. Host PC) from Windows, several programs are available. 3.14.1 Microsoft® ActiveSync® Microsoft® ActiveSync® gives you the possibility to connect your desktop computer to your Datalogic JOYA™ X2 and move files and folders back and forth. With ActiveSync®, it is possible to: - Back up and restore Datalogic JOYA™ X2 data. - Copy files between Datalogic JOYA™ X2 and desktop computer.
USE AND FUNCTIONING NOTE 3 Server and connecting to an FTP Client. See par.3.14.5. 3.14.4 Bluetooth® Manager Device Setup In order to enable a Bluetooth device for communication with the Datalogic Joya™ you must perform the discovery procedure and enable the device as follows: 1. Place the Bluetooth device within the range of the Datalogic Joya™ (10 meters). 2. From the “Control Panel” main window double tap on the “Bluetooth” applet to open the Bluetooth® Manager Device window: 3.