Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
CONTENTS Updates and Language Availability.....................................................................iv Using Quickscan™ M Gun and Cradle ............................................................... 1 System Connections ........................................................................................... 5 QuickScan™ M Cradle Configuration ................................................................. 7 QuickScan™ M Reader Configuration .................................................
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.scanning.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.scanning.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet.
QUICKSCAN™ MOBILE USING QUICKSCAN™ M GUN AND CRADLE The QuickScan™ M gun and cradle build a Cordless Reading System for the collection, decoding and transmission of barcoded data. Standard models can be connected to a Host PC through a USB, RS232, Wedge or Pen emulation cable. All models are suited for single-cradle layouts. The LEDs signal the QuickScan™ M cradle status, as described in the following table: LED BEEPER STATUS - Yellow On = QuickScan™ M cradle is powered.
DATALOGIC READING ANGLE QuickScan™ M readers automatically scan barcodes at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. Successful scanning is obtained by tilting the reader with respect to the barcode to avoid direct reflections, which could impair the reading performance. See the figures below. Successful reading is obtained by an audible tone.
QUICKSCAN™ MOBILE USING YOUR QUICKSCAN™ M READING SYSTEM Follow the procedure below to start using your QuickScan™ M reading system: 1. Connect a QuickScan™ M cradle to the Host. For installation and connection information see page 5. 2. Insert the QuickScan™ M gun into the cradle to start the battery charging. A full charge of the Lithium battery takes 3.5 – 6 hours. To achieve the best battery life, it is recommended to perform a full battery charge before using the gun in hand-held mode.
DATALOGIC 4. Insert the cover in the handle and screw it back into place. Figure 4 WARNING 4 Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
QUICKSCAN™ MOBILE SYSTEM CONNECTIONS Connections should always be made with power off! CAUTION You can connect the QuickScan™ M cradle to the Host through the dedicated connector, using the cable corresponding to the desired interface type. 1. Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle.
DATALOGIC IBM USB POS CAB-413 WEDGE CAB-391 or CAB-321 + CAB-431 WEDGE CAB-431 POWER SUPPLY ADAPTER PEN CAB-431 POWER SUPPLY ADAPTER 6
QUICKSCAN™ MOBILE QUICKSCAN™ M CRADLE CONFIGURATION The QuickScan™ M cradle configuration can be performed in two ways: either by sending configuration strings from the Host via the RS232 or USB-COM interface or by reading configuration barcodes with the reader. Serial/USB COM Configuration By connecting the QuickScan™ M cradle to a PC through an RS232 or USB cable (only USB-COM interface) it is possible to send configuration strings from the PC to the reader.
DATALOGIC 5. Read the Bind code to pair the QuickScan™ M gun to the cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. Bind Ì$+RN0$-IÎ The green LED on the QuickScan™ M reader will blink: the reader is ready to be positioned onto the cradle. 6. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the QuickScan™ M cradle has been paired to the QuickScan™ M gun. YOUR READER IS NOW READY TO READ CODES. 7.
QUICKSCAN™ MOBILE USB INTERFACE CONFIGURATION The USB interface is compatible with: - Windows 98 (and later) Mac SO 8.0 (and later) 4690 Operating System START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the cradle. Before the cradle is ready, the correct USB driver must be loaded.
DATALOGIC USB INTERFACE SELECTION USB-KBD (default) Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì$+UA00$-(Î USB-IBM-Hand Held Ì$+UA01$-.Î * When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web site http://www.scanning.datalogic.com. Select one keyboard nationality code from the table at page 15.
QUICKSCAN™ MOBILE RS232 INTERFACE SELECTION Read the QuickScan™ M cradle restore default code, and then read the interface selection code for your application: RESTORE QUICKSCAN™ M CRADLE DEFAULT Ì$+RX0$-qÎ RS232 INTERFACE Standard Ì$+CP0$-$Î POS TERMINALS Nixdorf Mode A Ì$+CM2EC0$->Î Fujitsu Ì$+CM1$-ÈÎ ICL Mode Ì$+CM0$-ÃÎ 11
DATALOGIC WEDGE INTERFACE SELECTION Read the QuickScan™ M cradle restore default code, then read the interface selection code for your application: RESTORE QUICKSCAN™ M CRADLE DEFAULT Ì$+RX0$-qÎ WEDGE INTERFACE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT Ì$+CP503$-vÎ PC Notebook Ì$+CP505$-ÈÎ IBM SURE1 Ì$+CP506$-$Î IBM Terminal 3153 Ì$+CP504$-}Î 12
QUICKSCAN™ MOBILE WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard).
DATALOGIC WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î 14
QUICKSCAN™ MOBILE USB / WEDGE KEYBOARD NATIONALITY USB/Wedge interface users should select one of the following KEYBOARD NATIONALITY codes. Belge Ì$+FJ7$-8Î Deutsch Ì$+FJ3$-$Î English Ì$+FJ4$-)Î Español Ì$+FJ6$-3Î Français Ì$+FJ2$-ÊÎ Italiano Ì$+FJ1$-ÅÎ Svenskt Ì$+FJ5$-.
DATALOGIC PEN INTERFACE SELECTION Read the QuickScan™ M cradle restore default code, then read the interface selection code for your application: RESTORE QUICKSCAN™ M CRADLE DEFAULT Ì$+RX0$-qÎ PEN INTERFACE Ì$+CP6$-BÎ 16
QUICKSCAN™ MOBILE OPERATING TEST Read the TEST codes below. EAN-8 1234 5670 EAN-13 1 234567 000992 Code 39 (Normal) 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0123456784 YOUR SYSTEM IS READY TO READ CODES AND TO SEND THE DATA TO THE HOST. To change the defaults, refer to the "QuickScan™ Mobile Reference Manual", part number 820001970, or to the Datalogic Aladdin™ Configuration program, both downloadable from the website.
DATALOGIC READER DEFAULT CONFIGURATION DATA FORMAT code identifier disabled (enabled for POS terminals), field adjustment disabled, code length tx not transmitted, character replacement disabled, address stamping disabled; address delimiter disabled POWER SAVE sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec READING PARAMETERS hand-held operation = hardware trigger, stand operation = automatic, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.
QUICKSCAN™ MOBILE CRADLE DEFAULT CONFIGURATION USB DEFAULT SETTINGS DATA FORMAT: code identifier disabled, code length not transmitted, character replacement disabled, address stamping disabled, address delimiter disabled. USB KEYBOARD: USA keyboard, FIFO enabled, inter-character and inter-code delays disabled. USB COM: handshaking disabled, delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.
DATALOGIC WEDGE DEFAULT SETTINGS USA keyboard, caps lock off, caps lock auto-recognition enabled; num lock unchanged, inter-character and inter-code delay disabled. DATA FORMAT: code identifier disabled, code length not transmitted, no header, terminator = ENTER, character replacement disabled, address stamping disabled, address delimiter disabled.
QUICKSCAN™ MOBILE Environmental Features – GUN Working Temperature Storage Temperature (without battery) Humidity Drop resistance Protection class 0°to + 40 °C (32° to 104 °F) -20° to 70 °C (-4° to 158 °F) 90% non condensing IEC 68-2-32 Test ED 1.
DATALOGIC WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 36 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
QUICKSCAN™ MOBILE COMPLIANCE This device must be opened by qualified personnel only. The batteries must be removed before opening the device. POWER SUPPLY This device is intended to be supplied by a UL Listed/CSA Certified Power Unit marked "Class 2" or LPS power source rated 5 V, minimum 0.8 A and having a cable length <3 m. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
DATALOGIC LED CLASS EN60825-1:(2001) QuickScan™ M Product Label Class 1 LED product. RADIO COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information.
QUICKSCAN™ MOBILE WEEE COMPLIANCE Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
DATALOGIC READING DIAGRAM Reading diagram at 25 °C and 300 lux ambient lighting Reading Zones (10° skew angle) (cm) -15 CODE39 0.50 mm (20 mils) 10 5 EAN13 M=1 0.33 mm (13 mils) 0.
QUICKSCAN™ MOBILE NUMERIC TABLE Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 27
Datalogic Scanning, Inc.
Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.