OM-DRAGON™ SERIES QUICK REFERENCE
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy OM-DRAGON™ Ed.: 11/2005 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
CONTENTS Updates and Language Availability.....................................................................iv Using OM-DRAGON™ Radio Cradle.................................................................. 1 Installation ........................................................................................................... 2 System Connections ........................................................................................... 5 Connecting and Disconnecting the OM-DRAGON™ Interface Cable.....
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a : www.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française.
OM-DRAGON™ USING OM-DRAGON™ RADIO CRADLE The OM-DRAGON™ cradle, paired with one or more DRAGON™ M series laser guns, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. It can be connected to a Host PC through an RS232, Wedge or Pen cable and is suited for both single-cradle and multi-cradle layouts. It can also be connected to a C-Box and therefore integrated into a fixed scanner application. To setup your OM-DRAGON™ cradle you must: 1.
DATALOGIC INSTALLATION The OM-DRAGON™ can be mounted for portable or fixed desktop usage, or it can be fixed to a wall. In all cases, the mounting base must be used. The OM-DRAGON™ package contains the following: OM-DRAGON™ This Quick Reference Manual 2 adhesive strips 4 rubber feet 3 screws 3 threaded dowels 1 alignment plate 1 Antenna Figure 1 - OM-DRAGON™ Mounting Base bottom view PORTABLE DESKTOP USE For desktop use, the OM-DRAGON™ is already correctly positioned on the base. 1. 2. 3.
OM-DRAGON™ FIXED DESKTOP USE For fixed desktop installation use the adhesive strips referring to Figure 1. 1. 2. 3. 4. 5. If you are installing several cradles and you desire to align them, you can use the alignment plate (see Alignment Plate Installation), otherwise continue with step 2. Carefully clean the adhesive strip seat of the base to remove any impurities that could reduce adhesion. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.
DATALOGIC For wall mounting, the cradle is positioned as shown in Figure 3: Figure 3 - OM-DRAGON™ Base 1. 2. 3. 4. 5. 6. 7. 8. If you are installing several cradles and you desire to align them, you can use the alignment plate (see Alignment Plate Installation), otherwise continue with step 2. Using the mounting holes on the base as a pattern mark the wall where you desire to mount the OM-DRAGON™. Drill three appropriate size holes. Insert the threaded dowels into the holes.
OM-DRAGON™ SYSTEM CONNECTIONS Connections should always be made with power off! CAUTION You can connect the OM-DRAGON™ cradle to the Host through the dedicated connector, using the cable corresponding to the desired interface type. CONNECTING AND DISCONNECTING OM-DRAGON™ INTERFACE CABLE THE The OM-DRAGON™ can be connected to a Host by means of an RS232, Wedge or Pen cable which must be simply plugged into the Host connector, visible on the rear panel of the cradle.
DATALOGIC RS232 CONNECTION WEDGE CONNECTION PEN CONNECTION 6
OM-DRAGON™ C-BOX CONNECTION OM-DRAGON™ CONFIGURATION The OM-DRAGON™ configuration can be performed in three ways: by using the DL Sm@rtSet software configuration program, by sending configuration strings from the Host PC via the RS232 interface or by reading configuration barcodes with the DRAGON™ M reader. DL SM@RTSET DL Sm@rtSet is a Windows-based utility program providing a quick and userfriendly configuration method via the RS232 interface.
DATALOGIC 1. Read the OM-DRAGON™ restore default code, then read the interface selection code for your application: RESTORE OM-DRAGON™ DEFAULT Ì$+RX0$-qÎ 2.
OM-DRAGON™ WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct key transmission code. Select the keyboard type if necessary (default = advanced keyboard).
DATALOGIC WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î 10
OM-DRAGON™ WEDGE KEYBOARD NATIONALITY If you selected the Wedge interface, you should also read among the following codes the one that matches your Keyboard Nationality: Belge Ì$+FJ7$-8Î Deutsch Ì$+FJ3$-$Î English Ì$+FJ4$-)Î Español Ì$+FJ6$-3Î Français Ì$+FJ2$-ÊÎ Italiano Ì$+FJ1$-ÅÎ Svenskt Ì$+FJ5$-.
DATALOGIC The following Keyboard Nationality selections are only valid for IBM AT compatible PCs: Japanese Ì$+FJ8$-=Î Russian (Latin) Ì$+FJ9$-BÎ Russian (Cyrillic) Ì$+FJA$-jÎ Hungarian Ì$+FJB$-oÎ Yugoslavian Ì$+FJC$-tÎ Romanian Ì$+FJD$-yÎ Czechoslovakian Ì$+FJE$-~Î 12
OM-DRAGON™ OPERATING TEST Read the TEST codes below. EAN-8 1234 5670 EAN-13 1 234567 000992 Code 39 (Normal) 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0123456784 PDF417 DATALOGIC PDF417 Test Code YOUR SYSTEM IS NOW READY TO READ CODES AND TO SEND THE DATA TO THE HOST. To change the defaults refer to the "Dragon™ Reference Manual", part number 90ACC1855, or to the DL Sm@rtSet™ Configuration program, both downloadable from the website.
DATALOGIC OM-DRAGON™ DEFAULT CONFIGURATION RS232 DEFAULT SETTINGS 9600 baud, parity disabled, 8 data bits, 1 stop bit, handshaking disabled, ack/nack protocol disabled, FIFO enabled, delay disabled, 5 sec.
OM-DRAGON™ TECHNICAL FEATURES OM-DRAGON™ Electrical Features Supply voltage Power consumption Indicators Time of recharge Radio Features 9..28 Vdc max. 8 W (charging) * Charger on LED (red) Charge completed LED (green) Power / Data LED (yellow) NiMh / NiCd batteries: 2 hours European Models USA Models Working Frequency 433.
DATALOGIC WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
OM-DRAGON™ FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This device contains FCC ID OMJ0015.
DATALOGIC S.p.A.