Gryphon™ I GBT4100 General Purpose Handheld Linear Imager Barcode Reader with Bluetooth® Wireless Technology Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Software Product Policy .............................................................................. 4 Customers Under Software Support ........................................... 4 Configuring the Base Station .................................................................... 5 Changing the Base Station Position ................................. 5 Connecting the Base Station .....................................................................
NOTES
Datalogic Scanning, Inc. GRYPHON™ PRODUCT SERIES END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
3.2 3.3 logic may elect not to terminate this Agreement or the granted licenses, but instead may elect to notify End User that End User is deemed to have ordered and accepted a license for each breaching use. End User shall pay Datalogic the applicable list price for such licenses as of the date of such breach.
.2 7.3 7.4 provided, that 1) End User notifies Datalogic promptly in writing of the claim, 2) Datalogic controls the defense or settlement of the claim, and 3) End User cooperates fully with Datalogic in such defense or settlement. All notices of a claim should be sent to Datalogic Scanning, Inc., Legal Department, 959 Terry Street, Eugene, OR 97402.
Software Product Policy writing, and shall be effective when received, with evidence of receipt. Notices to Datalogic shall be sent to the attention of Contract Administration, Datalogic Scanning, Inc., 959 Terry Street, Eugene, OR 97402, or such other address as may be specified by Datalogic in writing. 11.3 Waiver. A party's failure to enforce any of the terms and conditions of this Agreement shall not prevent the party's later enforcement of such terms and conditions. 11.
Setting Up the Reader Follow the steps below to connect and get your reader up and communicating with its host. 1. Configure the Base Station starting on this page. 2. Charge the Batteries (see page 11). 3. Link to the Base Station (see page 16). 4. Select the Interface Type (see page 16). 5. Configure the Reader starting on page 17 (optional, depends on settings needed).
Configuring the Base Station mounting, with lower retention of the scanner. The different parts may be interchanged to customize retention preferences. A tool such as a rigid pen or a flat screwdriver can be used to change the mounts. Do not allow it to touch the contacts. 1. Insert the appropriate parts for the desired base station position, as shown below. Standing, Horizontal or Vertical 2.
Connecting the Base Station 3. The stand can now be repositioned in either horizontal or standing position. Horizontal Standing Connecting the Base Station Figure 1 shows how to connect the Base Station to a terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding. Connect the interface cable before applying power to the Base Station. NOTE Gryphon BT can also be Powered by the Terminal.
Connecting the Base Station Figure 1. Connecting the Base Station Wall plug Connector I/F Cable AC/DC Adapter DC Power Cord Base Station Securing the DC Power Cord (Optional) The DC power cord for the adapter can be secured to the bottom of the base in order to maximize the mechanical retention of the cable itself. The routing of the power cord can be changed to accommodate the base station positioning: horizontal, stand or wall mounting.
Connecting the Base Station Figure 3. Arrows showing routing Host Connection: Verify before connection that the reader’s cable type is compatible with your host equipment. Most connections plug directly into the host device as shown in Figure 4 on page 9. Keyboard Wedge interface cables have a ‘Y’ connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal/PC. B Figure 4. Connecting to the Host Wa Ke W nd US or...
Connecting the Base Station NOTE Gryphon BT can also be Powered by the Terminal. The external power supply is recommended but not necessary. When powered by the Terminal, the battery charger is automatically set as Slow charge. Disconnecting the Cable: To detach the cable, insert a paper clip or similar object into the hole on the base, as shown in Figure 5. Figure 5.
Charging the Batteries Table 1. Radio Base LEDs LED STATUS Power on / Data Yellow On = Base is powered Yellow Blinking = Base receives data and commands from the Host or the Reader. Charging Red On = the Battery is charging. Charge completed Green On = the Battery is completely charged. Charging + Red and Green Blinking together = the Reader Charge completed is not correctly placed onto the Base.
Charging the Batteries Battery Safety To install, charge and/or do any other action on the battery, follow the instructions in this manual. WARNING Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury.
Charging the Batteries CAUTION CAUTION Do not place the battery in or near fire, on stoves or other high temperature locations. Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy. Do not place the battery in microwave ovens, high-pressure containers or on induction cookware.
Charging the Batteries Replacing the Batteries NOTE Before proceeding, read “Battery Safety” on the preceding pages. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. Use the following procedure to change the reader’s battery: 1. With a screwdriver, unscrew the battery cover screw. 2. Unplug the three screws securing the battery holder, and unplug the white connector.
Charging the Batteries 3. Carefully lift out the gold contacts circuit, and remove the battery holder while letting the white connector pass through the hole in the battery holder (as shown below). Pass-through hole Gold contacts circuit 4. Remove the old battery from its place (if present), and insert the new battery in the same position. 5. Replace the battery holder, plug in the connector and return the contacts circuit to its previous location.
Linking the Reader to the Base Station Linking the Reader to the Base Station RF Devices For RF devices, before configuring the interface it is necessary to link the handheld with the base. To link the handheld and the base, press the trigger to wake it and place it on the base. If the reader was previously linked to another base, you must first scan the Unlink action command before relinking to the new base. Unlink System and Network Layout Typical Setup with Cradle and Host Figure 7.
Selecting the Interface Type Using the Programming Barcodes The reader is factory-configured with a set of standard default features. After scanning the interface barcode from the Interfaces section, you can select other options and customize your reader through use of the instructions and programming barcodes available in the Gryphon™ I Product Reference Guide (PRG). Check the corresponding features section for your interface, and also the Data Editing and Symbologies chapters of the PRG.
Selecting the Interface Type Interface Selection Each reader model will support one of the following sets of host interfaces: General Purpose Models: RS-232, RS-232 OPOS, USB, Key- board Wedge, Wand. Retail Point of Sale Models : RS-232, RS-232 OPOS, USB, IBM 46XX. Information and programming options for each interface type are provided in this section. Configuring the Interface Scan the programming barcode which selects the appropriate interface type matching the system the reader will be connected to.
Selecting the Interface Type RS-232 (continued) RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS USB Com to simulate RS-232 standard interface Select USB-COM-STDa IBM IBM-46xx Port 5B reader interface Select IBM-P5B IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM a. Download the correct USB Com driver from www.datalogic.
Selecting the Interface Type Keyboard Interface Use the programming barcodes to select options for USB Keyboard and Wedge Interfaces.
Selecting the Interface Type KEYBOARD (continued) PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153 Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Select USB Keyboard Quick Reference Guide 21
Selecting the Interface Type KEYBOARD (continued) USB Keyboard with alternate key encoding Select USB Alternate Keyboard USB Keyboard for Apple computers Select USB-KBD-APPLE WAND EMULATION Wand Emulation Select WAND Scancode Tables Reference the Gryphon™ I PRG for information about control character emulation which applies to keyboard interfaces. Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes.
Selecting the Interface Type COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S.
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Czechoslovakia* Country Mode = Denmark* Country Mode = France Country Mode = Germany Country Mode = Hungary* Country Mode = Italy *Supports only the interfaces listed in the Country Mode feature description 24 Gryphon™ I GBT4100
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Japanese 106-key* Country Mode = Norway* Country Mode = Poland* Country Mode = Portugal* Country Mode = Romania* Country Mode = Slovakia* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide 25
Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Spain Country Mode = Sweden Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description 26 Gryphon™ I GBT4100
Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.
Selecting the Interface Type Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.
Technical Specifications Technical Specifications The following table contains Physical and Performance Characteristics, User Environment and Regulatory information. Item Description Physical Characteristics Color White/Gray Black/Gray Dimensions Height 7.1”/181 mm Length 3.9”/100 mm Width 2.8”/71 mm Weight (without cable) Approximately 8.7 ounces/246 g (reader with display) 8.
Technical Specifications Item Description Print Contrast Minimum 15% minimum reflectance Decode Capability UPC/EAN/JAN, P2 /P5 add-ons; Code 39; Italian Pharmacode 39; Code 128; C128 ISBT; Code 128 add-ons; I 2 of 5; Standard 2 of 5; Code 11;Codabar; EAN 128; Code 93; MSI; GS1 DataBar™ Omnidirectional, GS1 DataBar™ Limited, GS1 DataBar™ Expanded; Code4, Code5. Interfaces Supportedd RS-232 Std, RS-232 Wincor-Nixdorf, RS-232 OPOS, IBM 46xx (ports5B and 9B), USB Com Std.
Technical Specifications Item Description Regulatory Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950 EMI/RFI Pending: Europe - CE, Russia - GOST, Australia - C-tick, USA/CANADA - FCC/IC, Japan - JRF/VCCI, Mexico - NOM + Cofetel, South Korea - KCC, Brazil - ANATEL, Argentina - CNC LED class safety IEC Class 1 Radio Features Frequency Range 2400 to 2483.
LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming barcode labels.
LED and Beeper Indications INDICATION DESCRIPTION LED BEEPER Reader Disabled The reader has been disabled by the host. The LED blinks continuously N/A Green Spot is on continuously While in Stand Mode or Trigger Stand Mode the green spot shall be on while in stand watch state. N/A N/A Green Spota flashes momentarily Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value.
Error Codes INDICATION DESCRIPTION Label Programming Mode Acceptance of Programming Configuration option(s) have been successfully programmed via labels and the reader has exited Programming Mode. Label Programming Mode Cancel Item Entry Cancel label has been scanned. LED BEEPER N/A Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps. N/A Reader sounds two times at low frequency and current volume. a.
Base Station Indications Base Station Indications INDICATION LEDS Power-up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is not established Yellow LED blinking ~1Hz Data/labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly Configuration alignment with the HH is in progress Red LED blinks quickly Battery charger in progress Red LED on Battery charger complete Green LED on Battery charger error Gr
Regulatory Information All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules.
Statement of Agency Compliance FCC RF Radiation Exposure Statement This equipment complies with FCC radiation exposure limits under Specific Absorption Rate (SAR) tests for portable devices operating closer than 20 cm to nearby persons, set forth in an uncontrolled environment. The Gryphon BT4100 cordless imaging reader has been demonstrated to meet these RF emissions safety limits.
Statement of Agency Compliance Imager Labeling Sample labels are shown here to illustrate their location only. Please view the labels on your product for actual details. Scanner Regulatory Label C R US 10 239045 N263 INC.
Statement of Agency Compliance WEEE Statement Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
Warranty Warranty Datalogic warrants to Customer that Datalogic's products will be free from defects in materials and workmanship for a period of one year from product shipment. This warranty does not extend to batteries and cables. As consumable items batteries and cables carry a 90 day warranty from time of purchase for DOA (dead on arrival) defects.
Ergonomic Recommendations Ergonomic Recommendations CAUTION • • • • • • • • • • • In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Services and Support Services and Support Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.com and click on the links indicated for further information. Products Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities, including: Datalogic Aladdin™, a multi-platform utility program • that allows device configuration using a PC.
DECLARATION OF CONFORMITY EC-056 Rev.: 0 Pag.: 1 di 1 09 Datalogic Scanning Group Srl Via S.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.