Installation Manual

ETL LISTED. CONFORMS TO UL STD 1863 ANSI/UL STD 60950-1 CERTIFIED TO CAN/CSA STD C22.2 NO 60950-1
Tools Required:
• Impact Punch-Down Tool with 110 Blade
Installation:
Align the mounting pins of the Data Module with holes in the back of your Telecommunication
Enclosure and lock Data Module into place.
• Pull the Cat 5e (or higher rated) cables into your Telecommunication Enclosure from one of the side
knockouts.
• Install Cat 5e (or higher rated) cables from each location in the house to the Data Module. Match the
color-coding of the wires to the colors on the 110 IDC connectors.
• The wires should be punched down to the 110 IDC connectors using an industry standard punch-down
tool. Use the T568A wiring configuration as shown above.
CAUTION:
• Never install low voltage wiring during lightning storms.
• Never install low voltage wiring in wet locations unless the wire is specifically designed for wet
locations.
• Never touch un-insulated low voltage wires or terminals unless the wire has been disconnected at its
source.
• Do not use this product near water. For example: near a bath tub, wash bowl, kitchen sink, laundry tub,
in a wet basement or near a swimming pool.
• Consult and comply with local building and electrical codes, before and during installation of any
equipment.
• Never push objects of any kind into this product through cabinet slots as they may touch dangerous
voltages.
• Use caution when installing low voltage cables.
• Read and understand all instructions.
• Save these Instructions.
NOTE: Only Licensed Professionals Should Install this Product.
Wiring Diagram:
Instruction / Installation Sheet
8-Port Cat 5e Data Module
Part # 80-0030
DataComm Electronics, Inc.
6349 Peachtree Street
Norcross, GA 30071-1725
888.223.7977
770.662.8205
www.DataCommElectronics.com