Zhone 2800 Series FiberJACK ONT Hardware Installation Guide For software version 3.
Zhone Technologies @Zhone Way 7195 Oakport Street Oakland, CA 94621 USA 510.777.7000 www.zhone.com info@zhone.com COPYRIGHT C2000-2015 Zhone Technologies, Inc. and its licensors. All rights reserved. This publication is protected by copyright law.
TABLE OF CONTENTS About This Guide ..............................................................................................................................5 Style and notation conventions .............................................................................5 Typographical conventions.......................................................................................6 Related documentation.............................................................................................7 Acronyms.
Table of contents Chapter 2 Zhone 2800 Series FiberJACK ONT Installation ......................................37 Install the FiberJACK ONT .....................................................................................38 Installation precautions ...........................................................................................39 Providing power to the wallbox ............................................................................46 Power connections ...................................
About This Guide This guide is intended for use by installation technicians, system administrators, or network administrators. It explains how to install the Zhone 2800 Series FiberJACK ONT, electronics and cabling. Style and notation conventions This document uses the following conventions to alert users to information that is instructional, warns of potential damage to system equipment or data, and warns of potential injury or death. Carefully read and follow the instructions included in this document.
About This Guide Typographical conventions The following typographical styles are used in this guide to represent specific types of information. 6 Bold Used for names of buttons, dialog boxes, icons, menus, profiles when placed in body text, and property pages (or sheets). Also used for commands, options, parameters in body text, and user input in body text. Fixed Used in code examples for computer output, file names, path names, and the contents of online files or directories.
Related documentation Related documentation Refer to the following publication for additional information: • The FiberJACK Quick Installation Instructions for the model of ONT you are installing. These instructions are shipped with the ONT, but are also available on the Zhone website. • Zhone zNID Configuration Guide — explains how to use the ONT web interface and describes the system commands and parameters.
About This Guide Table 1: Acronyms and their descriptions (Continued) Acronym Description ONU Optical Network Unit PoE Power over Ethernet PPPoE Point-to-point protocol over Ethernet QoS Quality of service RF Radio Frequency RFoG Radio Frequency over Glass SC adaptor Subscriber connector adaptor SIP Session initiation protocol SNMP Simple network management protocol T1/E1 T1 is Trunk line 1 (or DS 1, digital signal level 1).
FCC Statement FCC Statement This device complies with Part 15 of the FCC Rules / Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
About This Guide Region Selection Limited by local law regulations, versions for North America do not have region selection options. The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite.
Important Safety Instructions Important Safety Instructions Read and follow all warning notices and instructions marked on the product and included in the manual. Veuillez lire et respecter toutes les notices d'avertissement et les instructions indiquées sur le produit et inclues dans le manuel. Laser Safety Instructions Zhone equipment and associated optical test sets use laser sources that emit light energy into fiber cables.
About This Guide • Prevent direct exposure to optical fiber ends or optical connector ends where laser signals are directly accessed. Do not handle pieces of optical fiber with fingers. Use tweezers or adhesive tape to lift and discard any loose optical fiber ends. • Wear rubber gloves to clean optical connectors. The gloves prevent direct contact with the isopropyl alcohol and prevent contamination of the ferrules with skin oils.
Important Safety Instructions • When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. • Install the ONT in accordance with national and local electric codes in order to meet all applicable requirements. Consult a qualified electrical consultant.
About This Guide 14 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
ZHONE 2800 SERIES FIBERJACK ONT This chapter describes the 2800 Series of zNIDs.
Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT components The Zhone 2800 Series FiberJACK ONTs are designed for wall mounting onto a standard 20 cubic inch electrical outlet box.
Overview Note that the 281x models do not have a power on/off switch Figure 3: LED indicators on GigE ports See Table 6, Zhone 2800 Series FiberJACK ONT GigE LEDS on page 34.
Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT features All 2800 Series ONTs are designed for indoor use. The 2800 Series share a common SW architecture with the 2400, 2600, 4200 and 9000 series of zNIDs, including the same intuitive Web interface and command line interface.
Zhone 2800 Series FiberJACK ONT models Figure 5: Zhone 2800 Series FiberJACK ONT models GPON models The GPON models have the following interfaces: Table 2: GPON models and interfaces Model Description ZNID-GPON-2804P-WAC GPON ONT, FiberJack, 4 GE w/PoE, AC powered ZNID-GPON-2804P-WDC GPON ONT, FiberJack, 4 GE w/PoE, DC powered zNID-GPON-2812P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, AC powered zNID-GPON-2812P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, DC powered zNID-GPON-2813P-WAC GPON WAN
Zhone 2800 Series FiberJACK ONT Table 2: GPON models and interfaces Model Description zNID-GPON-2815P-WAC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, WiFi, AC powered zNID-GPON-2815P-WDC GPON WAN, FiberJack, 2xGE(PoE), 1xPOTS, RFV, WiFi, DC powered Gigabit Ethernet models The Gigabit Ethernet models have the following interfaces: Table 3: Gigabit Ethernet models and interfaces 20 Model Description ZNID-GE-2804P-WAC Active Ethernet ONT (GE Uplink), FiberJack, 4 GE W/PoE, AC powered ZNID-GE-2804
Zhone 2800 Series FiberJACK ONT models Zhone 2800 Series FiberJACK ONT specifications The possible interfaces and number of interfaces depend on the specific model, see Zhone 2800 Series FiberJACK ONT models on page 18 for a list of models and their interfaces. Table 4: Zhone 2800 Series FiberJACK ONT common specifications Specifications Values Dimensions Inside wall outlet portion (all models) 2.75 in (70 mm) high x 1.75 in (45 mm) wide x 1.
Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Power • AC models – 2804P - 100-240 VAC 50/60 Hz - Max Power = 40W (ONT + 20W PoE load) - Max Power = 12W (ONT only) – 2810P Input Voltage: 90 to 240 VAC, 50-60 Hz Input Power: 35W (10W ONT plus 15W PoE load) Input Power: 10W (ONT only) • DC models – 2804P - 48 VDC (nom.
Zhone 2800 Series FiberJACK ONT models Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Interfaces Uplinks: • • GPON: – SC/APC connector – Full ITU-T G.984 compliance – 1310nm Tx (Upstream) – 1490nm Rx (Downstream) – Fixed SFF optics – Tx (Upstream) line rate 1.25 Gbps – Tx Launch Power: +0.5 to +5.0 dBm – Rx (Downstream) line rate: 2.
Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Standards Support • • • • • • • • • • • ITU-T G.984 compliant (GPON) • • • • • SIP (RFC 3261) • Various CLASS services — Caller ID, Call Waiting, Call Forwarding, Call Transfer, etc. • • • T.30 and T.38 Fax • • • • • • • • 2x2 MIMO • • 64 bit and 128 bit WEP support • • IGMP multicast POTS (Voice) Support Wireless (WiFi) Support IPTV 24 IEEE 802.
Zhone 2800 Series FiberJACK ONT models Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Protocol Support • • • • • GPON – ITU-T G.984 (GPON) – 32 T-CONTS per device – 32 GEM Ports per device – Activation with automatic discovered SN and password in conformance with ITU-T G.984.3 – AES-128 Decryption with key generation and switching – FEC (Forward Error Correction) – 802.
Zhone 2800 Series FiberJACK ONT Table 4: Zhone 2800 Series FiberJACK ONT common specifications (Continued) Specifications Values Management • • • • • • • ZMS (Zhone Management System) • • CE • • FCC Part 15, Class B Regulatory Compliance 26 OMCI Web UI Command Line Interface SNMP USP (Unified Service Provisioning) TR-069 UL FDA 21CFR1040 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
Zhone 2800 Series FiberJACK ONT dimensions Zhone 2800 Series FiberJACK ONT dimensions Figure 6: Zhone 280x Series FiberJACK ONT dimensions Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 27
Zhone 2800 Series FiberJACK ONT Figure 7: Zhone 281x Series FiberJACK ONT dimensions 28 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
Zhone 2800 Series FiberJACK ONT controls and switches Zhone 2800 Series FiberJACK ONT controls and switches This section describes the 2800 Series FiberJACK ONT controls: • Power On/Off Switch • Reset Button • LED Mode Selector Switch • Tamper Detection Switch Figure 8: 280x Series FiberJACK ONT controls and switches Zhone 2800 Series FiberJACK ONT Hardware Installation Guide 29
Zhone 2800 Series FiberJACK ONT Figure 9: 281x Series FiberJACK ONT controls and switches Power On/Off Switch zNID 280x models. The Power On/Off Switch is located on the left side of the 280x ONT faceplate. zNID 281x models. The Power On/Off Switch is located on the right side, above the Reset Switch but is under the faceplate.
Zhone 2800 Series FiberJACK ONT controls and switches Reset Button The unit can be reset by depressing the Reset Button for less than 10 seconds. Holding the Reset Button until all the LEDs illuminate (approximately 10 seconds) will reset the configuration to factory defaults and also reboot the device. zNID 280x Models The Reset Button is accessible through a hole on the top of the unit (with the Faceplate installed).
Zhone 2800 Series FiberJACK ONT Zhone 2800 Series FiberJACK ONT LEDs Figure 10: zNID-GPON-280x LEDS Figure 11: zNID-GPON-281x LEDS Table 5: zNID-GPON-2800 LEDs LED Name Color Behavoir Indicates CONFIG Green Solid On Unit is provisioned (provisioning is complete) Green Rapid blink (10/sec) OMCI provisioning is in progress* Green Slow blink (1/sec) SNMP provisioning is in progress* N/A Off Unit is not provisioned Green Solid On Ranged successfully Green: Slow blink (1/sec) Ranging in
Zhone 2800 Series FiberJACK ONT LEDs Table 5: zNID-GPON-2800 LEDs LED Name Color Behavoir Indicates STATUS Green Heartbeat (1 short blink every 5 seconds) Normal Operation Green Rapid blink Unit has been reset to Factory Defaults / is unconfigured (10/sec) WIFI VOICE Green Alternating fast blinking (1 sec rapid blink/1 sec off) EZ Touch communications in process Green Slow blink (2/second) Remote Mgt Access (OMCI, SNMP, HTTP, Telnet, or TR-069) Green Solid On Reboot or restart in proc
Zhone 2800 Series FiberJACK ONT Figure 12: Zhone 2800 Series FiberJACK ONT GigE LEDS Table 6: Zhone 2800 Series FiberJACK ONT GigE LEDS LED Name Color Indicates Right LED Off 10 BaseT Yellow 100 Base T Green 1000 Base T Left LED Off Link Down or Port Disabled (LINK/ ACTIVITY Yellow: Solid on Link up, no Tx/Rx traffic Yellow: Blinking Link up, Tx/Rx traffic present Green: Solid on Link up with PoE Power being delivered, no Tx/Rx traffic Green: Blinking Link up with PoE Power being deli
Logging in to the 2800 Series ONT Logging in to the 2800 Series ONT This section describes logging into the FiberJACK ONT locally with a browser or CLI (telnet) using the subscriber facing LAN port, GE1. This section assumes the ONT is in a default state with factory settings, including the default factory IP address. Figure 13: Log into GigE port to reach the Web UI or CLI on the zNID Note: The 2800 Series ONT may be managed by other means, however this guide only describes local management.
Zhone 2800 Series FiberJACK ONT 36 Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
ZHONE 2800 SERIES FIBERJACK ONT INSTALLATION This chapter describes the procedures for installing the FiberJACK ONT. The FiberJACK ONT comes complete with all hardware for installation into a standard single-gang electrical wallbox with 3.25 inches between vertical mounting holes. A metal wallbox should be used. This section applies to FiberJACK ONTs that are AC-powered or DC powered.
Zhone 2800 Series FiberJACK ONT Installation Install the FiberJACK ONT This section describes the procedures for installing the FiberJACK ONT. The FiberJACK ONT comes complete with all hardware for installation into a standard single-gang electrical wallbox with 3.25 inches between vertical mounting holes. A metal wallbox should be used. This installation guide applies to FiberJACK ONTs that are AC powered or DC powered.
Install the FiberJACK ONT Installation precautions WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring. Maximum operating temperature should not exceed the range of 0° C to 40° C (32° F to 104° F).
Zhone 2800 Series FiberJACK ONT Installation zNID 2800P series FiberJACK ONT installation procedure 1 Select location for the FiberJACK ONT The location for the FiberJACK ONT should be free of dust and moisture. The area in front of the FiberJACK ONT should be left open so that there is sufficient ventilation for the ONT. Select one of the mounting options, depending on the location for the wallbox: – Add a new wallbox and AC circuit.
Install the FiberJACK ONT c 4 The fiber must then be properly terminated with an SC/APC connector for GPON ONT models or with an SC/UPC connector for GE ONT models.
Zhone 2800 Series FiberJACK ONT Installation 2-wire DC source: When powering from a 2-wire DC source, strip the insulation back from the ends of the 2-wire DC cable to expose about 15mm (0.6") of bare copper wire. Connect these wires to the 2-pin connector on the back of the FiberJACK ONT. Check that the polarity is correct before connecting the wires. The positive terminal is on the right (closest to the RJ-45 connector).
Install the FiberJACK ONT Figure 16: 281x Models: Thread the fiber cable through the notch in the circuit board. Other than the connector type, fiber installation is the same for GPON and GE models. See Manage the optical cable, page 54 and page 55 for more information. h Remove the dust covers from the SC connector on the FiberJACK ONT, and from the SC/APC or SC/UPC termination on the fiber pigtail.
Zhone 2800 Series FiberJACK ONT Installation d Verify that the red Alarm LED turns on, and remains on until the GPON link successfully ranges or until the active Ethernet WAN connection is up (for Active Ethernet ONTs) If the GPON link does not range (or the GE link does not come up) troubleshoot the installation in conjunction with the staff responsible for OLT and ONT provisioning.
Install the FiberJACK ONT If the cable is not terminated, follow local practices to attach an RJ-45 connector. Connect telephone (POTS) service Figure 18: The voice port (POTS). Plug the line from the telephone into the POTS port. Connect coaxial service Figure 19: The TV port (coaxial). a Locate the premises’ coaxial cable. b If the cable is not terminated, follow local practices to attach a coaxial connector. c Screw the coaxial connector to the TV coaxial port.
Zhone 2800 Series FiberJACK ONT Installation Providing power to the wallbox WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation. Take all proper precautions or have a qualified electrician perform the tasks for installing electrical wiring.
Providing power to the wallbox 8 Connect the female, 3-pin, terminal-style connector to the stripped ends of the AC wires prepared in Step 6. Make sure that the three AC wires are connected to the correct pins by checking the wiring chart shown in Power connections on page 50. 9 Pull the heat-shrink tubing down which is closest to the connector and pull it down and stretch it so it will cover the terminal screws, then apply appropriate heat to shrink the larger diameter piece of tubing to the connector.
Zhone 2800 Series FiberJACK ONT Installation Providing power to AC powered ONTs, replacing an outlet in an existing wallbox 1 Turn off any electricity running to the wallbox. 2 Check that the outlet has sufficient space available inside for mounting the FiberJACK ONT The wallbox should have 3" (70mm) of unimpeded depth to allow for splices and connectors. 3 Partially remove the outlet from the wallbox, disconnect the AC wires attached to it, and label them for identification if necessary.
Providing power to the wallbox Pull the second smaller diameter heat-shrink tubing down over the end of the other molded tubing, then apply appropriate heat to shrink the smaller diameter piece of tubing over the end of the larger diameter piece to present a fully-insulated AC Power pigtail connection. This connection can be pushed into the wallbox and a wallbox cover added if the FiberJACK ONT will be installed at a later time.
Zhone 2800 Series FiberJACK ONT Installation Power connections • For 115/120VAC connections • For 115/120VAC connections with wire nuts • For 220/240VAC connections • For two pin DC connections • For RJ-45 Power over Ethernet WARNING! Installing electrical wires, especially for the AC installations, may be hazardous and could lead to serious injury or possibly death. Disconnect power before conducting the installation.
Power connections 3 wire ONT power for 115/120VAC connections using wire nuts Figure 21: 3 pin ONT power pigtail Table 8: For 115/120VAC connections with wire nuts Wallbox Side FiberJACK Side Name Typical Color Name Color Neutral White AC-N White with blue stripe Ground Green GND Green with yellow stripe Hot or Live Black AC-L Black with brown stripe 3 pin ONT power pigtail for 220/240VAC connections Figure 22: 3 pin ONT power pigtail for 220/240VAC Table 9: For 220/240VAC connections W
Zhone 2800 Series FiberJACK ONT Installation 2 pin DC connection Figure 23: 2 pin DC connection Table 10: For two pin DC connections Wallbox Side Terminal FiberJACK ONT Name Typical Color Name + 48V any 1 +VDC +48V Return any 2 -VDC RJ-45 DC Power over Ethernet connection The Power over Ethernet port on the back of the 2804P base assembly only provides power to the ONT. It is NOT an Ethernet LAN or WAN port.
Power connections Table 11: For RJ-45 Power over Ethernet Pins(1) Name Definition(2) 2-pair Mode A 2-pair Mode B 4-pair 1 and 2 Pair 1 DC in DC in 3 and 6 Pair 2 Return Return 4 and 5 Pair 3 DC in DC in 7 and 8 Pair 4 Return Return (1) RJ-45 pins shown are connected together within the 2804P ONT. (2) The polarity of DC In with respect to Return can be positive or negative.
Zhone 2800 Series FiberJACK ONT Installation Manage the optical cable When making a fiber optic connection, avoid touching the fiber cable ends to the outside of the mating connector. Touching can contaminate the connectors. Fiber handling Before making any connections, be sure that the optical cable fiber tips and components are clean and free of dust and debris. Testing optical power Table 12, Table 13, and Table 14 indicate various optical thresholds for the ONTs.
Connect to network cautions Connect to network cautions When connecting the SC connector from the electronics module to the SC connector in the zNID enclosure, observe the necessary precautions to decrease the risk of exposure to laser radiation. WARNING! Risk of eye damage. At all times when handling optical fibers, follow the safety procedures recommended by your company.
Zhone 2800 Series FiberJACK ONT Installation Figure 26: The zNID-GE-2800 models use fiber with an SC/UPC connector (blue) Note: To function properly the optical strength to the zNID should be between -8dBm and -28 dBm for GPON and between -2dBm and -23dBm for GE units. See page 54 for information.
INDEX Numerics 280x Series FiberJACK ONT controls and switches 29 281x Series FiberJACK ONT controls and switches 30 A AC power, 115/120VAC 50, 51 AC power, 220/240VAC 51 AC, providing power to ONT, existing wallbox 48 AC, providing power to ONT, new wallbox 46 Acronyms 7 APC 7 FiberJACK ONT 15 interfaces 23 model numbers 19 FiberJACK ONT Overview 15 G Gigabit Ethernet models 20 GigE 7 GPON models 19 I interfaces supported 23 IPTV 7 C L coaxial 45 Coaxial interface 23 components 16 Connect coaxial se
Index O Off Mode 31 Optical power, testing 54 SIP 24 specifications 21 Style conventions 5 Switches 29 P T PoE 52 POTS 45 POTS interfaces 23 Power On/Off Switch 30 Power, providing 46 Power, providing, DC, Power over Ethernet 52 Providing power, AC 50, 51 Providing power, DC 52 Tamper Detection Switch 31 TV port 45 Typographical conventions 6 V voice support 24 W R Reset Button 31 RF video overlay 23 RJ11 23 RJ-45 Ethernet ports 44 RJ-45 Jacks 23 S SC/APC connector 55 SC/UPC connector 56 58 Warni