BS422 installation and setup guideline Ver. 1.11 The information contained in this document is the property of Damm Cellular Systems A/S. This document is subject to copyright and shall not be published or reproduced, in whole or in part, without the written permission of Damm Cellular Systems A/S. © 2010 Damm Cellular Systems A/S. All rights reserved. Møllegade 68, DK-6400 Sønderborg, Denmark Phone: +45 74 42 35 00, Fax: +45 74 42 30 31, E-Mail: dcs@damm.dk, http://www.damm.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline INTRODUCTION This manual is intended for installation and configuration of the BS422 for operational use.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline North America regulations The Base Station Transceivers and products devices mentioned in this User Manual comply to FCC part 90 and Industry Canada (IC) RS119 regulations for such equipment. The equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline Antennas The outside antenna connected to this device must be installed on an outdoor permanent structure. L'antenne extérieure connectée à cet appareil doit être installée sur une structure permanente extérieure.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline REFERENCE DOCUMENTS For detailed information’s regarding the TetraFlex® release and features supported, please consult the documents listed below: No.: 1 2 3 Document Title TetraFlex v7.7 System description.pdf TetraOM_x.x_help.pdf TetraFlex_RN_x.x_201x-xx-xx_01.pdf * 4 TetraFlex update to x.x.pdf 5 TetraFlex x.x BS422 redundant setup.pdf 6 TetraFlex v.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline TABLE OF CONTENTS Introduction ................................................................................................................................................ 2 Reference documents .................................................................................................................................. 5 TetraFlex® Manual breakdown .....................................
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline REVISION Software covered by this manual (for information about other TetraFlex software modules see TetraFlex 8.xx user manual): Covered TetraFlex 8.xx modules Software module Version Node.exe OM.exe TR.exe 8.xx 8.xx 8.xx Record of Manual Versions Numbers SW. 8.xx Ver. 1.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline ABBREVIATIONS / DEFINITIONS Short AIE API Application Date Application Date Limit. Application PC BS BSC BSC.
Doc. No. Damm Cellular Systems A/S, Denmark PD PEI PSTN PTT RAM Release Date. Release number SACCH SCCH SCK SDS SELV Site SLA SNMP Software package SSI Subscriber register TBD TCP TEA1… TEI TETRA TetraOM ToIP TSI UDP User number UTP VoIP WAN Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline Packet Data Peripheral Equipment Interface Public Switched Telephone Network Push to Talk Random Access Memory The date where DAMM releases the software.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.
Doc. No. Damm Cellular Systems A/S, Denmark 1.1 Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline OPERATIONAL DESCRIPTION OF THE BS422 The BS422 has all the RF circuitry required for a completely self-contained base station. Its main RF components are outlined in Chapter “BS422 main components”.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline Hardware The BS422 is a compact single-box unit with build in duplex filter. The concept is based on a decentral architecture, which means that no further components like servers or switches are needed. All features for a functional trunked radio system is build into the BS422. The basestation is designed for direct outdoor mounting.
Doc. No. Damm Cellular Systems A/S, Denmark 1.2 Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline BS422- INSTALLATION 1.2.1 Environmental / climatic requirements The Base Station is designed for outdoor operation, such that it can be placed in the antenna mast close to the antennas. The Base Station is designed to be able to operate at severe environmental conditions. The Base Station is guaranteed to operate under ambient air temperatures from –25°C to +55°C Celsius.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline 1.2.4 BS422 main components Filter cover and filters removed.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline 1.2.5 Attaching RX/TX antennas Before installing the Base Station please read the application note in the TetraFlex user manual about the Antenna Systems.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline 1.2.6 Power connection to BS422 Before starting this task, please read the entire chapter carefully. RX/TX A RXB PS LAN GPS OUT A LAN/WAN or LAN/PPS 0V (+48V) GND - 48V Figure 1-4: Power connection The BS422 is operated at -48V nominal DC SELV (Safety Extra Low Voltage).
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline System Connector There is two type of System Connetors: 1. System Connector with LAN and WAN (30528001) 2. System Connector with LAN and PPS (30528002) Use a LSA tool for the Ethernet connection, a small flat screedriwer for the power connector and torx screwdriver for the fastner clamps.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline Cable connection for LAN, WAN- 30528001: NOTE: Cable used must be 0.4mm2 to 0.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline LAN /WAN connector: 1.2.7 Ethernet Connection The BS422 supports either 2 x 100 Mb/s. Ethernet connection for WAN and LAN or as an option 1 x 100Mb/s Ethernet for LAN and a Ethernet type DC connection for timing (PPS). The purpose of the connections is o To establish connection for control of the base station o To establish connection to other BS422 and for timing and synchronization.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline 1.2.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.
Doc. No. Damm Cellular Systems A/S, Denmark BS422 Installation guide- Rev. Date 1.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.
Doc. No. Damm Cellular Systems A/S, Denmark 2.1 Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline BS422 CONFIGURATION The BS422 software is preinstalled from factory with default setting (see bellow) and before the system can be used in an installation this default settings must be adapted to the actuel need. Please also consult TetraFlex user manual for more details on how to change settings.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline 2.1.2 Setting the frequenzies of the BS422 Some useful TetraOM Commands For detailed OM overview please see OM help files.
Doc. No. Damm Cellular Systems A/S, Denmark Rev. Date 1.11 2020-03-06 BS422 Installation and Setup guideline *) Alarm BS 422 (OM command 03/A) Comment 00: TX PLL unlocked Blocking Alarm (Hardware fault) 01: TX loop unstable Blocking Alarm (Hardware fault) 03: TX temperature high Blocking Alarm (TR421 temperature over 80˚C TX stopped) 06: TX output power Blocking Alarm (Check TX out power) 07: TX ant.