OPERATION MANUAL Wireless Remote Controller Kit MODELS: BRC7E61W English BRC7E65 Español Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference. Le agradecemos la compra de este acondicionador de aire Daikin.
1-1 1 ON OFF 8 1-2 3 H M L DOWN 10 C ON OFF UP 6 TEMP FAN H 4 M L TIME C hr. UP 9 2 11 FAN hr. DOWN 13 RESERVE CANCEL hr. 5 TIMER 12 MODE 15 hr.
PRIOR TO USE This operation manual is exclusively for instructions on how to use the wireless remote controller. Read also the operation manual attached to the indoor unit for safe usage of the system and maintenance. ANTES DE LA UTILIZACIÓN Este manual de instrucciones contiene sólo las instrucciones para el uso del control remoto sin cables. Lea también el manual de instrucciones que viene con la unidad interior para un uso seguro del sistema y para su mantenimiento.
CONTENTS ILLUSTRATION ...............................[1] PRIOR TO USE ...............................[2] 1 SAFETY CONSIDERATIONS ...........1 2 NAMES AND FUNCTIONS OF THE OPERATING SECTION ....................2 3 HANDLING FOR WIRELESS REMOTE CONTROLLER..................3 4 OPERATION RANGE........................4 5 OPERATION PROCEDURE .............5 6 NOT MALFUNCTION OF THE AIR CONDITIONER ........................10 7 HOW TO DIAGNOSE TROUBLE SPOTS ..........................10 1.
Do not place any burning appliance in the air current from the air conditioner, since such appliance may suffer incomplete combustion. Never place nor use any inflammable sprays near the air conditioner, since such sprays could cause a fire. 8 9 10 2. NAMES AND FUNCTIONS OF THE OPERATING SECTION (Fig. 1, 2) DISPLAY “ ” (SIGNAL TRANSMISSION) 1 This lights up when a signal is being transmitted. DISPLAY “ ” “ ” “ ”“ “ ” (OPERATION MODE) ” 2 This display shows the current OPERATION MODE.
20 21 22 23 24 OPERATING INDICATOR LAMP (Red) This lamp stays lit while the air conditioner runs. It flashes when the unit is in trouble. TIMER INDICATOR LAMP (Green) This lamp stays lit while the timer is set. AIR FILTER CLEANING TIME INDICATOR LAMP (Red) Lights up when it is time to clean the air filter. DEFROST LAMP (Orange) Lights up when the defrosting operation has started. (For cooling only type this lamp does not turn on.
Placing the remote controller in the remote controller holder Install the remote controller holder to a wall or a pillar with the attached screw. (Make sure it transmits) Placing the remote controller Removing the remote controller Slide from above Pull it upward • In case the remote controller is not used for a long time take out all batteries in order to prevent liquid leak of the battery.
The setting temperature range of the remote controller is 16°C to 32°C. VRV System See the operation manual provided with the air conditioner. 5. OPERATION PROCEDURE Refer to figure 1 on page [1] • Operating procedure varies with heat pump type and cooling only type. Contact your Daikin dealer to confirm your system type. • To protect the unit, turn on the main power switch 6 hours before operation.
FAN OPERATION ...................... “ ” DRY OPERATION...................... “ ” • See “FOR SYSTEM WITHOUT COOL/ HEAT CHANGEOVER REMOTE CONTROL SWITCH” for details on dry operation. (2) Press OPERATION MODE SELECTOR button several times and select “ ” (This operation is only available during dry operation.) 2 ON OFF ON/OFF • Hot air is circulated to warm the room. It will take some time from when the air conditioner is first started until the entire room becomes warm.
FAN FAN SPEED CONTROL Operation mode • When operating continuously at horizontal air flow direction Press FAN SPEED CONTROL button. High or Low fan speed can be selected. The microchip may sometimes control the fan speed in order to protect the unit. SWING AIR FLOW DIRECTION ADJUST Cooling Operation conditions UP AND DOWN DIRECTION • The movable limit of the flap is changeable. Contact your Daikin dealer for details.
PROGRAMMING TIME 2 UP DOWN Press the PROGRAMMING TIME button and set the time for stopping or starting the system. When this button is pressed, the time advances by 1 hour. UP When this button is pressed, the time goes backward by 1 hour. DOWN TIMER RESERVE RESERVE 3 HOW TO SET MASTER REMOTE CONTROLLER (For VRV system) • When the system is installed as shown below, it is necessary to designate the master remote controller.
When the indoor unit with master remote controller is set to “COOL”, you can switch over operation mode between “FAN”, “DRY” and “COOL”. When the indoor unit with master remote controller is set to “HEAT”, you can switch over operation mode between “FAN” and “HEAT”. When the indoor unit with master remote controller is set to “FAN”, you cannot switch operation mode. When attempting settings than that consented above, a “peep” is emitted as a warning.
NOTES • Cannot have two remote controller control system with only wireless remote controllers. (It will be a two remote controller control system having one wired and one wireless remote controllers.) • Under two remote controller control system, wireless remote controller cannot control timer operation. • Only the operating indicator lamp out of 3 other lamps on the indoor unit display functions. Control is set to the optional controller for centralized control.
3 MODE ON OFF Press OPERATION MODE SELECTOR BUTTON 24 6 TEMP TIME UP CODE FAN “ ” on the left-hand of the malfunction code blinks. UNIT NO. DOWN 24 6 RESERVE CANCEL TIMER MODE 4 DOWN Press PROGRAMMING TIMER BUTTON and change the malfunction code. Press until the indoor unit beeps twice. 5 /TEST 1 MODE Press OPERATION MODE SELECTOR BUTTON “ ” on the right-hand of the malfunction code blinks. 6 35 7 SWING UP UP DOWN II. IN CASE BESIDES EMERGENCY STOP 1. The unit does not operate at all.
2. The system operates but it does not sufficiently cool or heat. • If the set temperature is not proper. • If the FAN SPEED is set to LOW SPEED. • If the air flow angle is not proper. Contact the place of purchase in the following case. WARNING When you detect a burning odor, shut OFF power immediately and contact the place of purchase. Using the equipment in anything but proper working condition can result in equipment damage, electric shock and/or fire.
3P107422-12L EM01A116A (0701) HT FS