User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) Adjustable Bed Controller (ABC-2 Series) User’s Manual Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) LABELLING REQUIREMENTS (FCC Part 15.19 (a)(3)) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations. INFORMATION TO THE USER (Part 15.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) DOCUMENT HISTORY REVISION DATE COMMENTS ST 1.0 2005.07.08 1 revision created 1.1 2005.07.12 UP/DOWN reversed 1.2 2005.08.23 FCC Information is added. Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) CONTENTS DOCUMENT HISTORY...................................................................................... 3 CONTENTS........................................................................................................ 4 1. Introduction .................................................................................................. 5 1.1 Features .......................................................................................
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 1. Introduction 1.1 Features ABC-2 series adjustable bed controller is for adjust the bed to fit any position you like. With wireless hand control, you can raise your head and/or your feet to a position that most comfortable to you. It controls the vibration motors for massage as well as the head and foot actuators. Various massage operation such as single massage, dual massage, and wave massage can be achieved with wireless hand control.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 1.2 Systems Configuration Hand Control ABC-200HC-010 AC120V Max. 10M (30ft) PAIRING STATUS AC INPUT Adjustable Bed Controller Control Box ABC-200CB-010 HEAD Actuator FOOT Actuator BACK Massager LEG Massager Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 2. Hand Control 2.1 Specification Item Model Specification ABC-200HC-010 Massage Mode: Manual / Wave Massage Function Massage Intensity: 5 steps Timer: 30min Radio Frequency Radio Transmission Range Power Supply Dimension Weight Operating Condition 315MHz (FCC Part C 15.231) Max. 10 meters (30 feet) DC 3V, 2 AAA Alkaline Batteries 182.7mm(H) x 64.7mm(W) x 22.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 182.7mm 2.3 Dimension 64.7mm 22.0mm Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 3. Control Box 3.1 Specification Item Model No. of Control Output Specification ABC-200CB-010 2 Actuators: Head, Foot 2 Massage Motors: Back, Leg Massage Mode: Manual / Wave Massage Function Massage Intensity: 5 steps Timer: 30min Radio Frequency AC Power Input Dimension Weight Operating Condition 315MHz (FCC Part C 15.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 3.3 Dimension Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4. Control Box - Details 4.1 Front View Layout 4.2 Rear View Layout 4.3 ACTUATOR Connectors z PCB Header - MOLEX 5569-4pins, Right Angle/Dual Row z Cable Receptacle - MOLEX 5557-4pins, Dual Row z PIN Assignment - Pin 1: UP - Pin 2: GND - Pin 3: NEUTRAL - Pin 4: DOWN Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4.4 MASSAGE MOTOR Connectors z PCB Header - MOLEX 5569-4pins, Right Angle/Dual Row z Cable Receptacle - MOLEX 5557-4pins, Dual Row z PIN Assignment - Pin 1: MASSAGER - Pin 2: GND - Pin 3: NEUTRAL - Pin 4: N/C 4.5 AC INPUT Connector z PCB Header - Hanlim LAB1143-03, Right Angle z Cable Receptacle - Hanlim CHB1143-03 z PIN Assignment - Pin 1: NEUTRAL - Pin 2: GND - Pin 3: HOT(LINE) 4.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 4.7 STATUS LED z GREEN LED - Power Status, Wireless Pairing Status 4.8 PAIRING Button z For pairing between Hand Control and Control Box. 4.9 PCB Layout (Fuse, Header) Safety SWITCH Header - Jumper ON: Switch disabled - Jumper OFF: Switch enabled Fuse: AC250V, 10A Elisync Technologies LLC.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 5. System Setup Method 5.1 Wireless PAIRING Setup 1) In control box, press and release the PAIRING button to go into pairing mode. The GREEN INDICATOR light will begin to flash in 0.2 second interval. The pairing mode continues 10 seconds. After 10 seconds, control box exits from pairing mode automatically. 2) In hand control, press and hold the SET button for 3 seconds to go into pairing mode.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6. Hand Control Operation 6.1 Bed Position z 9 HEAD UP/DOWN Button To raise the head of the bed, press and hold the HEADUP button. Release the button when you achieve the desired bed position. 9 To lower the head of the bed, press and hold the HEAD-DOWN button. Release the button when you achieve the desired bed position. z 9 FOOT UP/DOWN Button To raise the foot of the bed, press and hold the FOOTUP button.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6.2 Bed Position Save & Recall z 9 POS1 & POS2 Button (Position Recall) Press the POS1 button to recall the programmed bed position 1. The bed moves automatically until the head and foot position reached to the programmed Position 1 saved. 9 Press the POS2 button to recall the programmed bed position 2. The bed moves automatically until the head and foot position reached to the programmed Position 2 saved.
User’s Manual: ABC-2 Series (SL) Revision 1.2 (August 23, 2005) 6.3 Massage Mode z 9 WAVE Button Press the WAVE button to activate the ‘Wave Program 1’ with 30 minutes timer. 9 Press the WAVE button 2nd time to activate the ‘Wave Program 2’. 9 Press the WAVE button to toggle between Program 1 and Program 2 repeatedly. 9 Press the WAVE button for 2 seconds to stop both massage motors. At the end of 30 minutes, both massage motors are automatically turned off.