Planning Sheet

All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
PLANNING
GUIDE
DTI
xx
Modernist
®
30”, 36” Wide,
Electric Induction Cooktops
WARNING
Follow local codes/ordinances during planning and installation. (Contact
the local building department for details.)
The cooktop must be installed per its installation instructions. Dacor is
not responsible for product damage/failure due to faulty installation.
Doc #: PGH-DTI.01 Revised 19 Sept 2018 Page 1 of 4
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
B
A
D
C
E
F
Cabinet 30” (mm) 36” (mm)
A Frame Depth 21
1
/4” (540) 21
1
/4” (540)
B Frame Width 30” (762) 36” (914)
C Case Depth 19
1
/2” (494.6) 19” (481.6)
D Case Width 28
3
/8” (720) 33
3
/4” (856.6)
E Conduit Case Height 4” (101) 4” (101)
F Case Height 3
1
/8” (80.5) 3
1
/8” (80.5)
IMPORTANT:
If installing a range hood or microwave hood combination
above the cooktop, follow the range hood or microwave
hood combination installation instructions for dimensions
and clearance above the cooktop surface.
G
F
A
C
E
E
D
B
Cooktop
Rear Wall
Countertop
Junction box
Minimum distance to
combustible side wall above
countertop (both sides)
DTI30M***** (30”) DTI36M***** (36”)
A 28
1
/2” - 28
2
/3” (724 mm - 728 mm)
33
6
/7” - 34” (860 mm - 864 mm)
B
19
4
/7” - 19
2
/3” (497.4 mm - 499.4 mm)
19
1
/8” - 19
1
/5” (485.6 mm - 487.6 mm)
C Min 1
1
/7” (28 mm). Between cutout and the wall behind the cooktop
D Min 1
1
/2” (38 mm). From front edge of cutout and front edge of countertop
E
Min 1” (26 mm). Distance nearest left-/right-side combustible surface above cooktop.
F Junction box or outlet 10” (254 mm) maximum from right-hand side of cabinet
G Junction box or outlet 15” (381 mm) minimum from bottom of countertop