User Manual

CONGRATULATIONS ON YOUR PURCHASE
Thank you for selecting the CyberPower P705G Surge Protector.
This manual explains the features and operation of the P705G.
Please take a few moments to read this manual.
FEATURES
1. Protected LED Indicator
Illuminated when the surge protection feature is working properly.
2. Grounded LED Indicator
Illuminated when the ground protection feature is working properly.
3. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A breaker.
When an overload occurs, it will automatically switch o. To
resume operation, ensure the overload condition is removed
and reset the surge protector by switching the unit ON.
4. Safety Covers
All outlets on this surge protector include safety covers. Slide
the plastic outlet cover over outlets that are not used. This
ensures the safety of children and prevents potential electric
shocks and damage caused by highly dusty environments.
5. Always-On Grounded Outlets (2)
Provides continuous power regardless of whether the Master
and Master controlled outlets are on or o.
6. Energy-Saving Master Controlled Grounded Outlets (4)
Automatically switched on or o by master outlet.
7. Energy-Saving Master Grounded Outlet
Automatically switches four master controlled outlets on or o.
8. Transformer-spaced Grounded Outlet (1)
Easily plug in large chargers without interfering with the
other outlets.
9. Threshold Switch
Adjusts the threshold at which the energy saving outlets adjust
the switch according to the device plugged into the Master outlet.
High mode: For high wattage devices such as a TV or PC.
Low mode: For low wattage devices such as a laptop.
SPECIFICATIONS
• Model Number: P705G
• Outlets: Standard Grounded Outlets (6) and Transformer-spaced
Grounded Outlet (1)
• Surge Protection: 2,100 Joules
• Electrical Rating: 125 V/15 A/1875 W
UL Clamping Voltage: UL 1449 3rd/400 V (L-N, L-G, N-G)
Maximum Peak Current: 105,000A
• 3 AC Lines Protected:
L-N: 45,000 A
L-G: 30,000 A
N-G: 30,000 A
The maximum surge possible on household wiring is 6,000 volts)
• Response Time: Less than 1 nanosecond
• Attenuation: Up to 32 dB
• Circuit Breaker: Resettable 15 Amp
• EMI/RFI Filtration: 150 kHz to 100 MHz
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK - Use only in dry
locations and only indoors. DO NOT plug into another relocatable
power tap. DO NOT “daisy chain” surge protectors. DO NOT use
with any aquarium equipment. DO NOT use if properly grounded
outlets are not available. DO NOT install this device if there is less
than 10 meters (30 feet) or more of wire between the electrical
outlet and electrical service panel. DO NOT use for medical or life
support equipment. This device features an internal protection
that will disconnect the surge protective component at the end
of its useful life, but it will maintain unprotected power to the
load. If this situation is undesirable for the application, follow the
manufacturer’s instructions for replacing the device.
TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may
have tripped. Examine your connected equipment and remove
the device that is overloading the circuit. Then, turn the ON/OFF
switch back to RESET.
If the grounded indicator does not light when you plug in the
surge protector, move the surge protector to a dierent
grounded three-prong AC outlet. If it still does not light, return
the product to the retailer for assistance. If the surge protector
appears to be working properly, your outlets may not be
properly grounded and need to be repaired by a professional
electrician. If the grounded indicator turns o after a period of
use, the surge protection has been depleted. Replace your
surge protector.
If the protected indicator does not light, the surge protector’s
AC lines are no longer protected from surge. The surge protector
may have received a power surge or spike beyond its specified
limits that overloaded the protection circuitry and rendered it
inactive. The surge protector has protected your connected
equipment as designed, but it will not protect against future
surges, and spikes. It should be replaced.
If the Master-controlled outlets don't turn on or o when your
laptop computer or TV is connected to the Master outlet:
1. The power drawn from the Master Outlet must be below the
threshold setting (High/Low) for the Master Controlled
Outlets to turn o. Some computers will continue to consume
power during battery charging or in standby mode. In this
case, please make sure hibernate or sleep mode is enabled on
your computer.
2. The power drawn from the Master Outlet must be above the
threshold setting (High/Low) for the Master Controlled
Outlets to turn on. Some computers and TVs will not draw
enough power to turn on the Master Controlled outlets. In this
case, please try plugging a dierent primary device into the
Master Outlet or make sure the threshold switch is set to Low.
TECHNICAL SUPPORT
Please contact our Tech Support Department with installation,
troubleshooting, or general product questions.
• Phone: 1-877-297-6937
• Email: tech@cpsww.com
• Hours of Operation: Monday – Friday 7:00am – 6:00pm CST
USER MANUAL
7-Outlet Energy Saving
Surge Protector
P705G
7-Outlet Energy Saving
Surge Protector
P705G
1
2
Copyright © 2019 Cyber Power Systems (USA), Inc. All rights reserved.
1
2
3
4
6
5
7
9
8

Summary of content (2 pages)