CubiSensTM TS100 User Manual v1.7 Table of Contents Introduction .................................................................................................................................................. 3 Important Notes before Using the TS100 ..................................................................................................... 3 TS100 Communication Kit ............................................................................................................................. 4 1.
CubiSensTM TS100 User Manual v1.7 Introduction CubiSensTM TS100 Wireless Temperature Sensor (TS100 in short) is a millimeter-scale wireless sensor for accurate, real-time temperature measurement. Measuring only 7.5 x 7.5 x 4.2 mm, the TS100 is capable of transmitting up to 100m in distance and last up to 2 years in sensing operation. The device is packaged in bio-compatible epoxy and coated with parylene, making it ideal for implanting in animal models.
CubiSensTM TS100 User Manual v1.7 TS100 Communication Kit 1. What’s in the Box The TS100 Communication Kit consists of: 1. 2. 3. 4. 5. 6. 7. CSG100-A9 CubiSens™ Gateway Gateway Antenna CubiSensTM Optical Programmer USB to Ethernet adapter Ethernet cable Micro USB cable 5V power adapter 1 4 2 5 3 7 6 Figure 2. TS100 Communication Kit Example Setup © 2020 CubeWorks. All rights reserved.
CubiSensTM TS100 User Manual v1.7 2. User System Requirements For proper operation of the TS100 Communication Kit, user needs access to a Windows computer with 2 available USB ports. Details on minimum system requirements is shown below. Minimum User System Requirements Operating System Memory Windows 7, 8, 10 1GB Processor 1GHz Software Framework Storage Microsoft .NET 4.7.2 500MB available disk space Ports 2 available USB 2.0 (or higher) ports 3. Hardware Assembly Figure 5.
CubiSensTM TS100 User Manual v1.7 4. Ethernet Configuration The USB-to-Ethernet adapter needs to be configured as follows (Windows 10 shown as example): 1. Verify that the USB to Ethernet adapter is connected to the computer using an available USB port. 2. Press the windows key on the keyboard, then start typing “ethernet” until you see the option for “Ethernet settings”. Select that and press enter or click on it. 3. A new window, “Ethernet” will open.
CubiSensTM TS100 User Manual v1.7 4. In the “Network Connections” window look for connections labeled “Ethernet”. If there are multiple ethernet connections find the one with the subtitles “ASIX AX88179…” or “Realtek USB..” Right click on that connection to bring up another menu. 5. In the context menu which appears choose “Properties”. © 2020 CubeWorks. All rights reserved.
CubiSensTM TS100 User Manual v1.7 6. In the new window that opens click on text “Internet Protocol Version 4(TCP/IPv4)” to select that line. Be careful not to click on any checkboxes. With “Internet Protocol Version 4(TCP/IPv4)” selected click on the button “Properties”. 7. Choose “Use the following IP address:” and set the IP address to 192.168.10.1. The subnet mask should automatically set itself to 255.255.255.0, but if not then set it to that value.
CubiSensTM TS100 User Manual v1.7 5. Driver & GUI Software Installation The GUI software is used to communicate with the TS100 through the optical programmer and gateway, providing a user interface for controlling the device and downloading its data. The software and driver need to be installed as follows: 1. Run “CDM21228_Setup.exe” in the installation kit and follow its installation instructions. This will allow the computer to send commands to the TS100 via the optical programmer. 2.
CubiSensTM TS100 User Manual v1.7 5. The green blinking status light next to the IP address of the gateway indicates connection status to the gateway. 6. The opening screen shows the settings. The COM Port of the Optical Programmer must be selected by clicking on the Serial Port selection dropdown menu. Note: If multiple ports are available, disconnect the micro USB cable from the Optical Programmer, select “Rescan Ports” from the selection box, and see which port disappears.
CubiSensTM TS100 User Manual v1.7 Using the TS100 1. Overview TS100 Wireless Temperature Sensor uses optical communication for receiving commands from the user and for RF communication transmitting data and status. The optical communication is intended for shortrange configuration and command, whereas the RF communication can be received from up to 100m lineof-sight. When implanted or operated in an environment with obstructions, RF communication distance can be significantly reduced. 2.
CubiSensTM TS100 User Manual v1.7 3. Starting Measurement To command the TS100 to start measuring temperature with a desired measurement interval: 1. 2. 3. 4. 5. Place the TS100 on the optical programmer. Select the tab “Control” in the TS100 GUI. Set the measurement interval. Click the “Start Measurement” button. After 3-4 seconds, the TS100 will reply with a “Measurement Started” message, the current battery state, and starts measuring at the set interval. 6.
CubiSensTM TS100 User Manual v1.7 5. Viewing Measured Data Real-Time Any measurement data from the TS100 received by the Gateway will be displayed in real-time on the GUI log as part of the “Check-in” message, and also as a datapoint in the “Plot” tab of the GUI, as shown in Figure 9. The plot may be used to examine measurement data. User can click on the plot to control it. After clicking, zooming can be accomplished with the mouse scroll wheel or Page Up and Page Down buttons on the keyboard.
CubiSensTM TS100 User Manual v1.7 Technical Specifications 1. TS100 Technical Specifications Please refer to the “TS100 Technical Datasheet” for full details on the technical specifications. Below are key specifications for TS100. TS100 Device Specifications Dimensions (W x L x H) 7.5 x 7.5 x 4.2 mm Weight 0.5g Thermal Reaction Time τ: 11.
CubiSensTM TS100 User Manual v1.7 2. CSG100-A9 CubiSens™ Gateway Tech Specs The CSG100-A9 CubiSens™ Gateway receives the RF transmissions from the TS100 sensors, interprets them, and provides them to the software. CSG100-A9 CubiSens™ Gateway CSG100-A9 CubiSens™ Gateway Specifications RF Receiving Frequency 915 ±10MHz Size 141 x 81 x 33mm Weight 400g Power Source 5V DC Power Consumption 10W © 2020 CubeWorks. All rights reserved.