Manual

@crown
®
Power Amplifier Quick Reference
Program
Material
Individual Speech
Acoustic/Chamber Music
Full Range Rock Music
Compressed Rock Music
Pink Noise
Current Draw
100VAC
1.5A
1.9A
2.3A
2.7A
3.1A
Waste Heat
BTU/Hr
350
390
430
470
510
CT-210: 8 Ohm Stereo Mode, 16 Ohm Bridged Mono, or 4 Ohm Parallel Mono
Current Draw
120VAC
1.3A
1.6A
1.9A
2.3A
2.6A
Current Draw
220VAC
0.7A
0.9A
1.1A
1.3A
1.5A
Current Draw
240VAC
0.6A
0.8A
1.0A
1.2A
1.3A
Program
Material
Individual Speech
Acoustic/Chamber Music
Full Range Rock Music
Compressed Rock Music
Pink Noise
Current Draw
100VAC
1.7A
2.3A
2.8A
3.4A
4.0A
Waste Heat
BTU/Hr
370
420
480
540
600
CT-210: 4 Ohm Stereo Mode, 8 Ohm Bridged Mono, or 2 Ohm Parallel Mono
Current Draw
120VAC
1.4A
1.9A
2.4A
2.8A
3.3A
Current Draw
220VAC
0.8A
1.0A
1.3A
1.6A
1.8A
Current Draw
240VAC
0.7A
1.0A
1.2A
1.4A
1.7A
Program
Material
Individual Speech
Acoustic/Chamber Music
Full Range Rock Music
Compressed Rock Music
Pink Noise
Current Draw
100VAC
1.5A
1.9A
2.3A
2.7A
3.0A
Waste Heat
BTU/Hr
350
390
430
460
500
CT-210: 70V Mode, Any Configuration
Current Draw
120VAC
1.3A
1.6A
1.9A
2.2A
2.5A
Current Draw
220VAC
0.7A
0.9A
1.0A
1.2A
1.4A
Current Draw
240VAC
0.6A
0.8A
1.0A
1.1A
1.3A
The information provided on this page
is calculated data based on driving
both channels to rated output. Other
parameters used in calculation include
a conservative idle current estimate
of 90 Watts and a conservative esti-
mation of efficiency at 65%. Informa-
tion is provided for the purpose of get-
ting an idea of current draw and heat
produced. Actual performance will
vary depending on environment,
program material, load, signal, and
AC mains voltage and frequency.
Values of calculated current draw
are intended to represent average
draw corresponding to the thermal
breaker requirements that should
be met to handle the amplifier as a
load on the AC mains. Peak current
draw with dynamic program mate-
rial may be significantly higher. Ther-
mal information is provided to assist
with calculating air conditioning
needs. The above data should not
be construed as specifications.
Com-Tech 210 Calculated Data

Summary of content (1 pages)